Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Hydrogen production, gaseous, 1 bar, from SOEC electrolysis, with steam input, from grid electricity [CH], per 1 kg. EF v3.1 climate change 5.908 kg CO2 eq (Monte Carlo 95 % interval 4.932–9.087). Main contributors: Electricity, low voltage, at grid 64 %; Steam, for chemical processes, at plant 25 %; Electrolyzer production, 1MWe, SOEC, Stack 10 %. Status: final control passed.
Item Value
Dataset name Hydrogen production, gaseous, 1 bar, from SOEC electrolysis, with steam input, from grid electricity
Dataset UUID / graph id 798136ae-86e2-3b0f-9db5-e9bc1ef165b3 / activity:hydrogen_production_gaseous_1_bar_from_soec_electrolysis_with_steam_input_from_grid_electricity__ch
Reference product, unit Hydrogen production, gaseous, 1 bar, from SOEC electrolysis, with steam input, from grid electricity, 1 kg
Location CH
Time period 2024-01/2024-01
Category fuels / synthetic\transformation
Source database BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1
Publisher Swiss Federal Office for the Environment (FOEN/BAFU)
Background database BAFU 2026 v1 (graph bafuquery-db)
LCIA method EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix)
Status final control passed
Documented by tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17

Introduction

1 kg H2 produced using a SOEC electrolyzer, with steam input, powered by Swiss grid electricity. Source: Niklas Gerloff, Comparative Life-Cycle-Assessment analysis of three major water electrolysis technologies while applying various energy scenarios for a greener hydrogen production, Journal of Energy Storage, Volume 43, 2021, https://doi.org/10.1/j.est0.20.1. Stack lifetime of 20'000 hours over 2.5 years. Further refined (with respect to stack and system lifetime and water use, notably) from data from manufacturer's specifications and IndWEDe project report (https://www.now-gmbh.de/wp-content/uploads/2020/09/181127_bro_a4_indwede-studie_kurzfassung_de_v03.pdf). For further secifications (e.g., efficiency, lifetime, etc.), refer to Sacchi, R. and Bauer, C. LCA of Power-to-X processes and applications in the residential sector. Paul Scherrer Institut, 2023. Stack lifetime [hours] 20'000: IndWEDe Stack lifetime [years] 2.5: IndWEDe, based on the lower estimate of 8,000 hours per year, from manufacturers' data. Balance of Plant lifetime [years]: Same as system. System lifetime [years] 20: IndWEDe Stack replacement over system's lifetime, excluding initial unit [unit]: 7 Calculated. Water demand [kg water/kg H2]: 8.9, corrected to 14 to represent “real world� operation.: (Simoes et al. 2021) Electricity demand [kWh/kg H2] 39: IndWEDe. Electrical Efficiency [%, based on H2 LHV]: 85%: : From row above. Productivity [kg H2/hour]: 23.6: From row above. Operating temperature [°C]: 650-1000: Manufacturers' data. Operating pressure [bar] ~1: IndWEDe Produced amount over system's lifetime years [kg H2] 3,776,000: Calculated based on the system's lifetime (fourth row), and 8,000 hours stack operation per year (from manufacturers' data) and hourly productivity. UUID: 798136ae-86e2-3b0f-9db5-e9bc1ef165b3

This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.

Goal and scope

Function, functional unit and reference flow

Reference flow: 1 kg of Hydrogen production, gaseous, 1 bar, from SOEC electrolysis, with steam input, from grid electricity (CH). All results are given per unit of the reference flow.

System boundary

—

Technology

—

Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).

LCIA method

EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.

Life cycle inventory

Inventory table

Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).

Exchange Type Location / compartment Amount Unit Uncertainty Pedigree GWP share (%) Notes
Electricity, low voltage, at grid technosphere CH 39 kWh lognormal, GSD² 1.33 — 64.0 █████████████
Steam, for chemical processes, at plant technosphere RER 5.76 kg lognormal, GSD² 1.33 — 25.3 █████
Electrolyzer production, 1MWe, SOEC, Stack technosphere RER 2.1190e-06 p lognormal, GSD² 3.11 — 9.8 ██
Electrolyzer production, 1MWe, SOEC, Balance of Plant technosphere RER 2.6480e-07 p lognormal, GSD² 3.11 — 0.8 ·
Water, deionised, at plant technosphere CH 14 kg lognormal, GSD² 1.33 — 0.1 ·
Treatment of fuel cell balance of plant, 1MWe, SOEC technosphere RER 2.6480e-07 p lognormal, GSD² 3.11 — 0.0 ·
Treatment of fuel cell stack, 1MWe, SOEC technosphere RER 2.1190e-06 p lognormal, GSD² 3.11 — 0.0 ·
From industrial area elementary natural resource 1.3240e-05 m2 lognormal, GSD² 1.64 — 0.0 ·
Industrial area, CH elementary natural resource [CH] 2.6480e-04 m2.a lognormal, GSD² 1.64 — 0.0 ·
To industrial area elementary natural resource 1.3240e-05 m2 lognormal, GSD² 1.64 — 0.0 ·
Hydrogen elementary air/Unknown 0.0024 kg lognormal, GSD² 1.33 — 0.0 ·

Data quality

0 of 11 direct exchanges carry a declared pedigree, 11 carry a distribution.

Field As declared by the publisher
Data generator / entry / validation data generator: Romain Sacchi (PSI); data entry: Romain Sacchi (PSI); validation (proof reading): Romain Sacchi (PSI)
sampling procedure Sampling procedure: Literature data
validation details Proof reading validation: Passed, Other validation: none, Validator: Rolf Frischknecht, Telephone: 0041 44 940 61 91, E-mail: frischknecht@treeze.ch, Company: treeze, Country: CH

Data gaps, proxies and assumptions

None recorded.

Life cycle impact assessment (EF v3.1)

Per 1 kg. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.

Impact category Indicator Unit Result 2.5 % 97.5 % GSD²
Acidification Accumulated Exceedance (AE) mol H+ eq 0.014 0.01143 0.02617 1.5
Climate change-Biogenic Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.1051 0.07049 0.1871 1.64
Climate change-Fossil Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 5.79 4.834 8.958 1.36
Climate change-Land use and land use change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.01279 0.008374 0.02108 1.6
Climate change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 5.908 4.932 9.087 1.36
EF-particulate Matter Impact on human health disease incidence 2.239e-07 1.720e-07 4.253e-07 1.56
Ecotoxicity, freshwater_inorganics Comparative Toxic Unit for ecosystems (CTUe) CTUe 19.53 16.6 46.4 1.72
Ecotoxicity, freshwater_organics Comparative Toxic Unit for ecosystems (CTUe) CTUe 0.3187 0.2613 0.9562 1.98
Ecotoxicity, freshwater Comparative Toxic Unit for ecosystems (CTUe) CTUe 19.85 16.92 47.31 1.72
Eutrophication marine Fraction of nutrients reaching marine end compartment (N) kg N eq 0.003949 0.003355 0.006459 1.41
Eutrophication, freshwater Fraction of nutrients reaching freshwater end compartment (P) kg P eq 0.004061 0.002269 0.01786 2.85
Eutrophication, terrestrial Accumulated Exceedance (AE) mol N eq 0.02796 0.02417 0.04915 1.43
Human toxicity, cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 1.250e-09 1.140e-09 3.718e-09 1.82
Human toxicity, cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 1.977e-09 1.409e-09 3.570e-09 1.59
Human toxicity, cancer Comparative Toxic Unit for human (CTUh) CTUh 3.227e-09 2.832e-09 6.865e-09 1.57
Human toxicity, non-cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 7.561e-08 6.411e-08 2.646e-07 2.06
Human toxicity, non-cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 4.786e-09 3.087e-09 1.432e-08 2.19
Human toxicity, non-cancer Comparative Toxic Unit for human (CTUh) CTUh 8.040e-08 6.842e-08 2.724e-07 2.05
Ionising radiation, human health Human exposure efficiency relative to U235 kBq U235 eq 28.24 9.658 165.9 4.28
Land use Soil quality index pt (soil quality index) 61.8 40.2 124.6 1.75
Ozone depletion Ozone Depletion Potential (ODP) kg CFC-11 eq 4.919e-07 3.651e-07 7.927e-07 1.48
Photochemical ozone formation - human health Tropospheric ozone concentration increase kg NMVOC eq 0.0115 0.01 0.02148 1.5
Resource use, fossils Abiotic resource depletion fossil fuels (ADP-fossil) MJ 309.5 236.4 481.9 1.44
Resource use, minerals and metals Abiotic resource depletion (ADP ultimate reserve) kg Sb eq 4.653e-05 2.657e-05 1.382e-04 2.32
Water use User deprivation potential (deprivation-weighted water consumption) m3 world eq deprived 2.791 -9264 4983 —

Climate change 5.908 kg CO2 eq per kg. Main contributors: Electricity, low voltage, at grid 64 %; Steam, for chemical processes, at plant 25 %; Electrolyzer production, 1MWe, SOEC, Stack 10 %.

Interpretation

Significant issues

Direct exchanges dominating climate change: Electricity, low voltage, at grid 64 %; Steam, for chemical processes, at plant 25 %; Electrolyzer production, 1MWe, SOEC, Stack 10 %. Most sensitive exchanges (Section 6.3): Electricity, low voltage, at grid [CH] (-15.6 / +20.6 %); Electrolyzer production, 1MWe, SOEC, Stack [RER] (-6.6 / +19.9 %); Steam, for chemical processes, at plant [RER] (-6.2 / +8.1 %).

Independent recalculation

Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026):

Category Graph Published Graph / published
Acidification 0.014 0.01549 0.904
Climate change-Biogenic 0.1051 0.1051 1.000
Climate change-Fossil 5.79 5.79 1.000
Climate change-Land use and land use change 0.01279 0.01279 1.000
Climate change 5.908 5.908 1.000
EF-particulate Matter 2.239e-07 2.239e-07 1.000
Ecotoxicity, freshwater_inorganics 19.53 20.45 0.955
Ecotoxicity, freshwater_organics 0.3187 0.3122 1.021
Ecotoxicity, freshwater 19.85 20.76 0.956
Eutrophication marine 0.003949 0.003936 1.003
Eutrophication, freshwater 0.004061 0.004061 1.000
Eutrophication, terrestrial 0.02796 0.03174 0.881
Human toxicity, cancer_inorganics 1.250e-09 1.197e-09 1.044
Human toxicity, cancer_organics 1.977e-09 1.977e-09 1.000
Human toxicity, cancer 3.227e-09 3.175e-09 1.017
Human toxicity, non-cancer_inorganics 7.561e-08 7.302e-08 1.035
Human toxicity, non-cancer_organics 4.786e-09 4.786e-09 1.000
Human toxicity, non-cancer 8.040e-08 7.781e-08 1.033
Ionising radiation, human health 28.24 28.24 1.000
Land use 61.8 50.23 1.230
Ozone depletion 4.919e-07 4.919e-07 1.000
Photochemical ozone formation - human health 0.0115 0.0115 1.000
Resource use, fossils 309.5 309.5 1.000
Resource use, minerals and metals 4.653e-05 4.597e-05 1.012
Water use 2.791 3.065 0.911
Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like.
Also published by BAFU for this dataset: IPCC 2021 GWP100 5.905 kg CO2 eq; Ecological Scarcity
2021 total 2.153e+04 UBP.

Sensitivity check

One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.

Exchange Base Low / high Range Δ GWP100 (%) Δ other categories (max %)
Electricity, low voltage, at grid [CH] 39 kWh ×0.757 / ×1.32 lognormal, GSD² 1.33 -15.6 / +20.6 31.9 (Ionising radiation, human health)
Electrolyzer production, 1MWe, SOEC, Stack [RER] 2.119e-06 p ×0.329 / ×3.04 lognormal, GSD² 3.11 -6.6 / +19.9 35.4 (Human toxicity, cancer_inorganics)
Steam, for chemical processes, at plant [RER] 5.76 kg ×0.757 / ×1.32 lognormal, GSD² 1.33 -6.2 / +8.1 11.1 (Ecotoxicity, freshwater_organics)
Electrolyzer production, 1MWe, SOEC, Balance of Plant [RER] 2.648e-07 p ×0.329 / ×3.04 lognormal, GSD² 3.11 -0.5 / +1.6 7.9 (Human toxicity, cancer_inorganics)
Water, deionised, at plant [CH] 14 kg ×0.757 / ×1.32 lognormal, GSD² 1.33 -0.0 / +0.0 2.1 (Water use)
Treatment of fuel cell balance of plant, 1MWe, SOEC [RER] 2.648e-07 p ×0.329 / ×3.04 lognormal, GSD² 3.11 -0.0 / +0.0 0.0 (Human toxicity, non-cancer_organics)
Treatment of fuel cell stack, 1MWe, SOEC [RER] 2.119e-06 p ×0.329 / ×3.04 lognormal, GSD² 3.11 -0.0 / +0.0 0.0 (Land use)
From industrial area [natural resource] 1.324e-05 m2 ×0.617 / ×1.62 lognormal, GSD² 1.64 -0.0 / +0.0 0.1 (Land use)
Industrial area, CH [natural resource [CH]] 2.648e-04 m2.a ×0.617 / ×1.62 lognormal, GSD² 1.64 -0.0 / +0.0 0.1 (Land use)
To industrial area [natural resource] 1.324e-05 m2 ×0.617 / ×1.62 lognormal, GSD² 1.64 -0.0 / +0.0 0.1 (Land use)

Uncertainty analysis

Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.

Comparison with other data

No other location of this dataset in the graph.

Conclusions and limitations

GWP100 5.908 kg CO2 eq per kg (95 % interval 4.932–9.087). Dominant contributors: Electricity, low voltage, at grid 64 %; Steam, for chemical processes, at plant 25 %; Electrolyzer production, 1MWe, SOEC, Stack 10 %. Most sensitive: Electricity, low voltage, at grid [CH] (-15.6 / +20.6 %); Electrolyzer production, 1MWe, SOEC, Stack [RER] (-6.6 / +19.9 %); Steam, for chemical processes, at plant [RER] (-6.2 / +8.1 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.

Final control

Item Status Detail
reference flow PASS production amount 1.0 kg
closure: sum of direct contributions = dataset score (all 25 categories) PASS largest relative gap 2.6e-16
independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) PASS graph / published = 1; categories within ±5 %: 21/25
every technosphere input of the EcoSpold delivery is in the graph PASS all present (bafu_links_check.py)
uncertainty declared on the direct exchanges PASS 11/11 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values
Monte Carlo 95 % interval contains the deterministic score PASS 5.908 in [4.932, 9.087]
time period declared PASS 2024-01/2024-01
geography is a known location code PASS CH
sources cited PASS 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them

References

  1. Report — source; as declared by BAFU (not found in OpenAlex/Crossref)
  2. Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — database; dataset citation
  3. International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva.
  4. Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. (tdc-doc method reference; title, version and year to verify against the user's copy)
  5. European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra.
  6. Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236

Annex — licence and terms of use

BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.


To suggest a correction or a dataset that does not exist yet, use Propose a dataset.