Dataset documentation and final control (tdc-doc, imported mode)
Open this dataset in OpenData
Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Electricity, supply mix GO [CH], per 1 kWh. EF v3.1 climate change 0.01814 kg CO2 eq (Monte Carlo 95 % interval 0.01814–0.02438). Main contributors: Electricity, from natural gas 23 %; Electricity, hard coal, at power plant 15 %; Electricity, nuclear, at power plant pressure water reactor 10 %; Electricity, hydropower, net, at reservoir power plant 8 %; Electricity, nuclear, at power plant boiling water reactor 7 %; Electricity, at cogen 300kWth, biomethane, allocation exergy 6 %. Status: final control passed.
| Item | Value |
|---|---|
| Dataset name | Electricity, supply mix GO |
| Dataset UUID / graph id | 7981d0dd-f80c-3508-8ba2-45cd7d99326a / activity:electricity_supply_mix_go__ch |
| Reference product, unit | Electricity, supply mix GO, 1 kWh |
| Location | CH — Data apply to public and self producers in Switzerland and from imports. Wind power plants are European averages. |
| Time period | 2020/2020 |
| Category | electricity / supply mix |
| Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 |
| Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) |
| Background database | BAFU 2026 v1 (graph bafuquery-db) |
| LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) |
| Status | final control passed |
| Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 |
Electricity domestic net production shares are based on annual averages for the year 2019; UUID:7981d0dd-f80c-3508-8ba2-45cd7d99326a
This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.
Reference flow: 1 kWh of Electricity, supply mix GO (CH). All results are given per unit of the reference flow.
Included are the shares of domestic electricity production and imports by technology at the busbar. Not included are transformation, transport or distribution losses
No technology description is provided because the dataset just describes the power plant portfolio of the respective country using current average technology per energy carrier.
Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).
EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.
Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).
| Exchange | Type | Location / compartment | Amount | Unit | Uncertainty | Pedigree | GWP share (%) | Notes | |
|---|---|---|---|---|---|---|---|---|---|
| Electricity, from natural gas | technosphere | ENTSO-E | 0.008488 | kWh | lognormal, GSD² 1.07 | — | 23.5 | █████ | |
| Electricity, hard coal, at power plant | technosphere | DE | 0.0025786 | kWh | lognormal, GSD² 1.07 | — | 14.6 | ███ | |
| Electricity, nuclear, at power plant pressure water reactor | technosphere | CH | 0.12845 | kWh | lognormal, GSD² 1.07 | — | 9.8 | ██ | |
| Electricity, hydropower, net, at reservoir power plant | technosphere | CH | 0.29371 | kWh | lognormal, GSD² 1.07 | — | 8.1 | ██ | |
| Electricity, nuclear, at power plant boiling water reactor | technosphere | CH | 0.083531 | kWh | lognormal, GSD² 1.07 | — | 7.1 | █ | |
| Electricity, at cogen 300kWth, biomethane, allocation exergy | technosphere | CH | 0.0035329 | kWh | lognormal, GSD² 1.07 | — | 6.2 | █ | |
| Electricity, production mix photovoltaic, at plant | technosphere | CH | 0.028698 | kWh | lognormal, GSD² 1.07 | — | 4.7 | █ | |
| Electricity, hydropower, at run-of-river power plant | technosphere | CH | 0.22609 | kWh | lognormal, GSD² 1.07 | — | 4.5 | █ | |
| Electricity, residual mix | technosphere | CH | 0.022026 | kWh | lognormal, GSD² 1.07 | — | 4.2 | █ | |
| Electricity, at cogen 1MWth, natural gas, allocation exergy | technosphere | CH | 0.0011819 | kWh | lognormal, GSD² 1.07 | — | 3.8 | █ | |
| Electricity, hydropower, at run-of-river power plant | technosphere | RER | 0.14341 | kWh | lognormal, GSD² 1.07 | — | 2.9 | █ | |
| Electricity, at cogen with biogas engine, agricultural covered, alloc. exergy | technosphere | CH | 0.0029141 | kWh | lognormal, GSD² 1.07 | — | 2.5 | · | |
| Electricity, hydropower, at reservoir power plant, non alpine regions | technosphere | RER | 0.027316 | kWh | lognormal, GSD² 1.07 | — | 2.4 | · | |
| Electricity, at cogen 1MWth, wood chips, allocation exergy | technosphere | CH | 0.0065412 | kWh | lognormal, GSD² 1.07 | — | 2.3 | · | |
| Electricity, hydropower, at small hydropower plant | technosphere | CH | 0.053953 | kWh | lognormal, GSD² 1.07 | — | 1.4 | · | |
| Electricity, at wind farm | technosphere | RER | 0.014075 | kWh | lognormal, GSD² 1.07 | — | 1.1 | · | |
| Electricity, at cogen 300kWth, diesel, allocation exergy | technosphere | CH | 1.0744e-04 | kWh | lognormal, GSD² 1.07 | — | 0.4 | · | |
| Electricity, at wind farm | technosphere | CH | 0.0028068 | kWh | lognormal, GSD² 1.07 | — | 0.3 | · | |
| Electricity, at cogen 300kWth, biomethane, allocation exergy | technosphere | CH | 4.0040e-05 | kWh | lognormal, GSD² 1.07 | — | 0.1 | · | |
| Electricity, nuclear, at power plant pressure water reactor | technosphere | FR | 0.0017191 | kWh | lognormal, GSD² 1.07 | — | 0.1 | · | |
| Electricity, at cogen with biogas engine, agricultural covered, alloc. exergy | technosphere | CH | 3.3028e-05 | kWh | lognormal, GSD² 1.07 | — | 0.0 | · | |
| Electricity, at cogen 1MWth, wood chips, allocation exergy | technosphere | CH | 7.4136e-05 | kWh | lognormal, GSD² 1.07 | — | 0.0 | · | |
| Electricity, production mix photovoltaic, at plant | technosphere | DE | 1.0744e-04 | kWh | lognormal, GSD² 1.07 | — | 0.0 | · | |
| Electricity from waste, at municipal waste incineration plant | technosphere | CH | 0.015452 | kWh | lognormal, GSD² 1.07 | — | -0.0 | · | |
| Electricity from waste, at municipal waste incineration plant | technosphere | CH | 0.0074136 | kWh | lognormal, GSD² 1.07 | — | -0.0 | · | |
| Electricity from waste, at municipal waste incineration plant | technosphere | CH | 1.7513e-04 | kWh | lognormal, GSD² 1.07 | — | -0.0 | · |
0 of 26 direct exchanges carry a declared pedigree, 26 carry a distribution.
| Field | As declared by the publisher |
|---|---|
| Data generator / entry / validation | data generator: Rolf Frischknecht (TREEZE); data entry: Rolf Frischknecht (TREEZE); validation (proof reading): Rolf Frischknecht (TREEZE) |
| sampling procedure | Statistical data |
| uncertainty adjustments | none |
| validation details | automatic validation in Excel |
| time period comment | Time period of statistics used. |
None recorded.
Per 1 kWh. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.
| Impact category | Indicator | Unit | Result | 2.5 % | 97.5 % | GSD² |
|---|---|---|---|---|---|---|
| Acidification | Accumulated Exceedance (AE) | mol H+ eq | 4.490e-05 | 4.562e-05 | 6.122e-05 | 1.16 |
| Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | 0.001013 | 8.216e-04 | 0.00138 | 1.31 |
| Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | 0.01643 | 0.01637 | 0.02252 | 1.18 |
| Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | 7.036e-04 | 4.838e-04 | 0.001122 | 1.52 |
| Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | 0.01814 | 0.01814 | 0.02438 | 1.17 |
| EF-particulate Matter | Impact on human health | disease incidence | 2.264e-09 | 1.752e-09 | 3.951e-09 | 1.52 |
| Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | 0.05773 | 0.0584 | 0.1334 | 1.52 |
| Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | 0.00118 | 0.001184 | 0.002864 | 1.65 |
| Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | 0.05891 | 0.05979 | 0.1356 | 1.51 |
| Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | 2.074e-05 | 2.069e-05 | 2.802e-05 | 1.17 |
| Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | 5.530e-06 | 4.183e-06 | 2.784e-05 | 2.73 |
| Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | 1.933e-04 | 1.902e-04 | 2.543e-04 | 1.17 |
| Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | 2.762e-12 | 3.294e-12 | 6.702e-12 | 1.46 |
| Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | 1.364e-11 | 9.093e-12 | 2.365e-11 | 1.61 |
| Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | 1.640e-11 | 1.340e-11 | 2.852e-11 | 1.47 |
| Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | 1.742e-10 | 2.024e-10 | 4.432e-10 | 1.49 |
| Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | 1.043e-11 | 9.854e-12 | 1.849e-11 | 1.37 |
| Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | 1.847e-10 | 2.145e-10 | 4.627e-10 | 1.48 |
| Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | 0.3658 | 0.1339 | 2.098 | 4.19 |
| Land use | Soil quality index | pt (soil quality index) | 0.6013 | 0.3687 | 1.047 | 1.7 |
| Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | 1.081e-08 | 9.089e-09 | 1.330e-08 | 1.21 |
| Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | 5.157e-05 | 5.178e-05 | 7.949e-05 | 1.24 |
| Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | 3.341 | 2.933 | 4.282 | 1.21 |
| Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | 1.138e-07 | 1.080e-07 | 2.082e-07 | 1.4 |
| Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | 0.03232 | -411.2 | 202 | — |
Climate change 0.01814 kg CO2 eq per kWh. Main contributors: Electricity, from natural gas 23 %; Electricity, hard coal, at power plant 15 %; Electricity, nuclear, at power plant pressure water reactor 10 %; Electricity, hydropower, net, at reservoir power plant 8 %; Electricity, nuclear, at power plant boiling water reactor 7 %; Electricity, at cogen 300kWth, biomethane, allocation exergy 6 %.
Direct exchanges dominating climate change: Electricity, from natural gas 23 %; Electricity, hard coal, at power plant 15 %; Electricity, nuclear, at power plant pressure water reactor 10 %; Electricity, hydropower, net, at reservoir power plant 8 %; Electricity, nuclear, at power plant boiling water reactor 7 %; Electricity, at cogen 300kWth, biomethane, allocation exergy 6 %. Most sensitive exchanges (Section 6.3): Electricity, from natural gas [ENTSO-E] (-1.5 / +1.6 %); Electricity, hard coal, at power plant [DE] (-1.0 / +1.0 %); Electricity, nuclear, at power plant pressure water reactor [CH] (-0.6 / +0.7 %).
Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh:
| Category | Graph | Published | Graph / published |
|---|---|---|---|
| Acidification | 4.490e-05 | 6.679e-05 | 0.672 |
| Climate change-Biogenic | 0.001013 | 0.001013 | 1.000 |
| Climate change-Fossil | 0.01643 | 0.01641 | 1.001 |
| Climate change-Land use and land use change | 7.036e-04 | 7.036e-04 | 1.000 |
| Climate change | 0.01814 | 0.01813 | 1.001 |
| EF-particulate Matter | 2.264e-09 | 2.263e-09 | 1.000 |
| Ecotoxicity, freshwater_inorganics | 0.05773 | 0.06369 | 0.906 |
| Ecotoxicity, freshwater_organics | 0.00118 | 0.001131 | 1.044 |
| Ecotoxicity, freshwater | 0.05891 | 0.06478 | 0.909 |
| Eutrophication marine | 2.074e-05 | 2.041e-05 | 1.016 |
| Eutrophication, freshwater | 5.530e-06 | 5.529e-06 | 1.000 |
| Eutrophication, terrestrial | 1.933e-04 | 1.962e-04 | 0.985 |
| Human toxicity, cancer_inorganics | 2.762e-12 | 2.559e-12 | 1.079 |
| Human toxicity, cancer_organics | 1.364e-11 | 1.363e-11 | 1.000 |
| Human toxicity, cancer | 1.640e-11 | 1.619e-11 | 1.013 |
| Human toxicity, non-cancer_inorganics | 1.742e-10 | 1.599e-10 | 1.090 |
| Human toxicity, non-cancer_organics | 1.043e-11 | 1.044e-11 | 0.999 |
| Human toxicity, non-cancer | 1.847e-10 | 1.704e-10 | 1.084 |
| Ionising radiation, human health | 0.3658 | 0.3658 | 1.000 |
| Land use | 0.6013 | 0.471 | 1.277 |
| Ozone depletion | 1.081e-08 | 1.080e-08 | 1.000 |
| Photochemical ozone formation - human health | 5.157e-05 | 5.166e-05 | 0.998 |
| Resource use, fossils | 3.341 | 3.341 | 1.000 |
| Resource use, minerals and metals | 1.138e-07 | 1.119e-07 | 1.017 |
| Water use | 0.03232 | 0.03524 | 0.917 |
| Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | |||
| Also published by BAFU for this dataset: IPCC 2021 GWP100 0.01813 kg CO2 eq; Ecological Scarcity | |||
| 2021 total 164.2 UBP. |
One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.
| Exchange | Base | Low / high | Range | Δ GWP100 (%) | Δ other categories (max %) |
|---|---|---|---|---|---|
| Electricity, from natural gas [ENTSO-E] | 0.008488 kWh | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | -1.5 / +1.6 | 1.8 (Ecotoxicity, freshwater_organics) |
| Electricity, hard coal, at power plant [DE] | 0.002579 kWh | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | -1.0 / +1.0 | 1.8 (Eutrophication, freshwater) |
| Electricity, nuclear, at power plant pressure water reactor [CH] | 0.1285 kWh | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | -0.6 / +0.7 | 3.8 (Ozone depletion) |
| Electricity, hydropower, net, at reservoir power plant [CH] | 0.2937 kWh | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | -0.5 / +0.6 | 4.0 (Climate change-Land use and land use change) |
| Electricity, nuclear, at power plant boiling water reactor [CH] | 0.08353 kWh | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | -0.5 / +0.5 | 2.9 (Ozone depletion) |
| Electricity, at cogen 300kWth, biomethane, allocation exergy [CH] | 0.003533 kWh | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | -0.4 / +0.4 | 4.6 (Climate change-Biogenic) |
| Electricity, production mix photovoltaic, at plant [CH] | 0.0287 kWh | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | -0.3 / +0.3 | 4.7 (Resource use, minerals and metals) |
| Electricity, hydropower, at run-of-river power plant [CH] | 0.2261 kWh | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | -0.3 / +0.3 | 0.8 (Human toxicity, non-cancer_organics) |
| Electricity, residual mix [CH] | 0.02203 kWh | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | -0.3 / +0.3 | 0.8 (Land use) |
| Electricity, at cogen 1MWth, natural gas, allocation exergy [CH] | 0.001182 kWh | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | -0.2 / +0.3 | 0.3 (Ecotoxicity, freshwater_organics) |
| Electricity, hydropower, at run-of-river power plant [RER] | 0.1434 kWh | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | -0.2 / +0.2 | 0.5 (Human toxicity, non-cancer_organics) |
| Electricity, at cogen with biogas engine, agricultural covered, alloc. exergy [CH] | 0.002914 kWh | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | -0.2 / +0.2 | 2.1 (Eutrophication, terrestrial) |
| Electricity, hydropower, at reservoir power plant, non alpine regions [RER] | 0.02732 kWh | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | -0.2 / +0.2 | 2.9 (Climate change-Land use and land use change) |
| Electricity, at cogen 1MWth, wood chips, allocation exergy [CH] | 0.006541 kWh | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | -0.1 / +0.2 | 6.0 (Land use) |
| Electricity, hydropower, at small hydropower plant [CH] | 0.05395 kWh | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | -0.1 / +0.1 | 0.4 (Human toxicity, non-cancer_inorganics) |
Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.
No other location of this dataset in the graph.
GWP100 0.01814 kg CO2 eq per kWh (95 % interval 0.01814–0.02438). Dominant contributors: Electricity, from natural gas 23 %; Electricity, hard coal, at power plant 15 %; Electricity, nuclear, at power plant pressure water reactor 10 %; Electricity, hydropower, net, at reservoir power plant 8 %; Electricity, nuclear, at power plant boiling water reactor 7 %; Electricity, at cogen 300kWth, biomethane, allocation exergy 6 %. Most sensitive: Electricity, from natural gas [ENTSO-E] (-1.5 / +1.6 %); Electricity, hard coal, at power plant [DE] (-1.0 / +1.0 %); Electricity, nuclear, at power plant pressure water reactor [CH] (-0.6 / +0.7 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.
| Item | Status | Detail |
|---|---|---|
| reference flow | PASS | production amount 1.0 kWh |
| closure: sum of direct contributions = dataset score (all 25 categories) | PASS | largest relative gap 4.4e-16 |
| independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh (climate change) | PASS | graph / published = 1.001; categories within ±5 %: 17/25 |
| every technosphere input of the EcoSpold delivery is in the graph | PASS | all present (bafu_links_check.py) |
| uncertainty declared on the direct exchanges | PASS | 26/26 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values |
| Monte Carlo 95 % interval contains the deterministic score | PASS | 0.01814 in [0.01814, 0.02438] |
| time period declared | PASS | 2020/2020 |
| geography is a known location code | PASS | CH |
| sources cited | PASS | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them |
BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.