Table of Contents

Process specific emissions and resources, from uranium milling, underground mine — GLO

Dataset documentation and final control (tdc-doc, imported mode)
Open this dataset in OpenData

Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Process specific emissions and resources, from uranium milling, underground mine [GLO], per 1 kg. EF v3.1 climate change 0.6301 kg CO2 eq (Monte Carlo 95 % interval 0.2392–2.434). Main contributors: Blasting 90 %; Transport, freight, lorry, fleet average 7 %; Transport, freight, rail 4 %. Status: final control passed.
Item Value
Dataset name Process specific emissions and resources, from uranium milling, underground mine
Dataset UUID / graph id 7b410767-5f22-3588-ad2d-d8db86bc2b4a / activity:process_specific_emissions_and_resources_from_uranium_milling_underground_mine__glo
Reference product, unit Process specific emissions and resources, from uranium milling, underground mine, 1 kg
Location GLO
Time period 2011-01/2011-12
Category minerals / new uranium ds
Source database BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1
Publisher Swiss Federal Office for the Environment (FOEN/BAFU)
Background database BAFU 2026 v1 (graph bafuquery-db)
LCIA method EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix)
Status final control passed
Documented by tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17

Introduction

PSI data (BFE project 407, Christian Bauer, April 2012).; UUID: 7b410767-5f22-3588-ad2d-d8db86bc2b4a

This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.

Goal and scope

Function, functional unit and reference flow

Reference flow: 1 kg of Process specific emissions and resources, from uranium milling, underground mine (GLO). All results are given per unit of the reference flow.

System boundary

The module includes: diesel used in generators for all mining uses; transport of the diesel fuel; radioactive and non-radioactive emissions to air and water; water use (mining water).

Technology

Average conditions in early 1980s.

Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).

LCIA method

EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.

Life cycle inventory

Inventory table

Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).

Exchange Type Location / compartment Amount Unit Uncertainty Pedigree GWP share (%) Notes
Blasting technosphere RER 0.26 kg lognormal, GSD² 3 — 89.5 ██████████████████
Transport, freight, lorry, fleet average technosphere RER 0.23 tkm lognormal, GSD² 2.5 — 6.9 █
Transport, freight, rail technosphere RER 1.37 tkm lognormal, GSD² 2.5 — 3.6 █
Nitrate elementary water/River 0.041 kg lognormal, GSD² 3 — 0.0 ·
From mineral extraction site elementary natural resource 0.005 m2 lognormal, GSD² 2 — 0.0 ·
Uranium Alpha elementary water/River 310 kBq lognormal, GSD² 10 — 0.0 ·
Water elementary natural resource 0.1 m3 lognormal, GSD² 3 — 0.0 ·
Particles (> PM10) elementary air/Medium stack, <150 meters / Rural (<… 0.033 kg lognormal, GSD² 5 — 0.0 ·
Selenium elementary water/River 4.1000e-04 kg lognormal, GSD² 3 — 0.0 ·
Zinc(2+) elementary water/River 8.9000e-04 kg lognormal, GSD² 3 — 0.0 ·
Thorium-230 elementary water/River 300 kBq lognormal, GSD² 10 — 0.0 ·
Beryllium elementary air/Medium stack, <150 meters / Rural (<… 9.8000e-07 kg lognormal, GSD² 5 — 0.0 ·
Chloride(1-) elementary water/River 0.6 kg lognormal, GSD² 10 — 0.0 ·
Uranium Alpha elementary air/Medium stack, <150 meters / Rural (<… 23 kBq lognormal, GSD² 10 — 0.0 ·
To mineral extraction site elementary natural resource 0.005 m2 lognormal, GSD² 2 — 0.0 ·
Cadmium elementary air/Medium stack, <150 meters / Rural (<… 2.0000e-06 kg lognormal, GSD² 5 — 0.0 ·
Vanadium(5+) elementary water/River 0.0048 kg lognormal, GSD² 3 — 0.0 ·
Aluminium elementary water/River 0.0023 kg lognormal, GSD² 3 — 0.0 ·
Radon-222 elementary air/Medium stack, <150 meters / Rural (<… 1.0000e+06 kBq lognormal, GSD² 10 — 0.0 ·
Suspended Solids, Unspecified elementary water/River 0.15 kg lognormal, GSD² 3 — 0.0 ·
Magnesium elementary water/River 0.082 kg lognormal, GSD² 3 — 0.0 ·
To unspecified elementary natural resource 0.005 m2 lognormal, GSD² 2 — 0.0 ·
Sulfate elementary water/River 3.4 kg lognormal, GSD² 3 — 0.0 ·
Cadmium(2+) elementary water/River 6.8000e-05 kg lognormal, GSD² 3 — 0.0 ·
Mineral extraction site elementary natural resource 0.1 m2.a lognormal, GSD² 2.5 — 0.0 ·
Zinc elementary air/Medium stack, <150 meters / Rural (<… 2.0000e-05 kg lognormal, GSD² 5 — 0.0 ·
Sodium(1+) elementary water/River 4.7 kg lognormal, GSD² 3 — 0.0 ·
Molybdenum elementary water/River 0.018 kg lognormal, GSD² 3 — 0.0 ·
Manganese elementary water/River 7.5000e-04 kg lognormal, GSD² 3 — 0.0 ·
Radium-226 elementary water/River 1600 kBq lognormal, GSD² 10 — 0.0 ·
Arsenic, ion elementary water/River 6.8000e-05 kg lognormal, GSD² 3 — 0.0 ·
Barium elementary water/River 0.0014 kg lognormal, GSD² 3 — 0.0 ·
Benzo[a]pyrene elementary air/Medium stack, <150 meters / Rural (<… 6.7000e-08 kg lognormal, GSD² 5 — 0.0 ·
Radium-226 elementary air/Medium stack, <150 meters / Rural (<… 13 kBq lognormal, GSD² 5 — 0.0 ·
From unspecified elementary natural resource 0.005 m2 lognormal, GSD² 2 — 0.0 ·
Lead elementary water/River 0.013 kg lognormal, GSD² 3 — 0.0 ·
Lead elementary air/Medium stack, <150 meters / Rural (<… 2.0000e-05 kg lognormal, GSD² 5 — 0.0 ·
Iron, ion elementary water/River 0.11 kg lognormal, GSD² 10 — 0.0 ·
Ammonium elementary water/River 0.065 kg lognormal, GSD² 3 — 0.0 ·
Water elementary water/Unknown 0.095 m3 lognormal, GSD² 2.52 — 0.0 ·

Data quality

0 of 40 direct exchanges carry a declared pedigree, 40 carry a distribution.

Field As declared by the publisher
Data generator / entry / validation data generator: Roberto Dones; data entry: Roberto Dones; validation (proof reading): Roberto Dones
extrapolations none
sampling procedure Literature
production volume na
uncertainty adjustments none

Data gaps, proxies and assumptions

None recorded.

Life cycle impact assessment (EF v3.1)

Per 1 kg. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.

Impact category Indicator Unit Result 2.5 % 97.5 % GSD²
Acidification Accumulated Exceedance (AE) mol H+ eq 0.1125 0.0338 0.3362 3.19
Climate change-Biogenic Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 8.819e-04 4.212e-04 0.003944 3.16
Climate change-Fossil Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.6289 0.2384 2.432 3.34
Climate change-Land use and land use change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 4.074e-04 2.252e-04 0.00119 2.33
Climate change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.6301 0.2392 2.434 3.33
EF-particulate Matter Impact on human health disease incidence 8.353e-07 2.701e-07 2.939e-06 3.39
Ecotoxicity, freshwater_inorganics Comparative Toxic Unit for ecosystems (CTUe) CTUe 744.2 406.8 4311 3.09
Ecotoxicity, freshwater_organics Comparative Toxic Unit for ecosystems (CTUe) CTUe 0.1982 0.0769 0.7299 3.15
Ecotoxicity, freshwater Comparative Toxic Unit for ecosystems (CTUe) CTUe 744.4 407 4311 3.09
Eutrophication marine Fraction of nutrients reaching marine end compartment (N) kg N eq 0.09542 0.05049 0.2308 2.18
Eutrophication, freshwater Fraction of nutrients reaching freshwater end compartment (P) kg P eq 9.659e-05 4.817e-05 8.503e-04 4.4
Eutrophication, terrestrial Accumulated Exceedance (AE) mol N eq 0.5823 0.1766 1.746 3.2
Human toxicity, cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 2.918e-09 1.537e-09 8.027e-09 2.31
Human toxicity, cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 3.280e-10 1.446e-10 1.421e-09 3.13
Human toxicity, cancer Comparative Toxic Unit for human (CTUh) CTUh 3.246e-09 1.812e-09 8.488e-09 2.14
Human toxicity, non-cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 4.540e-07 3.303e-07 9.140e-07 1.69
Human toxicity, non-cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 1.295e-09 4.950e-10 4.605e-09 3.15
Human toxicity, non-cancer Comparative Toxic Unit for human (CTUh) CTUh 4.553e-07 3.315e-07 9.155e-07 1.69
Ionising radiation, human health Human exposure efficiency relative to U235 kBq U235 eq 1150 122.9 1.088e+04 9.95
Land use Soil quality index pt (soil quality index) 14.88 -12.97 53.42 —
Ozone depletion Ozone Depletion Potential (ODP) kg CFC-11 eq 1.173e-08 5.535e-09 4.685e-08 3.05
Photochemical ozone formation - human health Tropospheric ozone concentration increase kg NMVOC eq 0.1045 0.03395 0.3503 3.24
Resource use, fossils Abiotic resource depletion fossil fuels (ADP-fossil) MJ 6.669 2.885 24.88 3.08
Resource use, minerals and metals Abiotic resource depletion (ADP ultimate reserve) kg Sb eq 1.844e-06 6.565e-07 1.281e-05 4.68
Water use User deprivation potential (deprivation-weighted water consumption) m3 world eq deprived 0.2578 -74.83 40.24 —

Climate change 0.6301 kg CO2 eq per kg. Main contributors: Blasting 90 %; Transport, freight, lorry, fleet average 7 %; Transport, freight, rail 4 %.

Interpretation

Significant issues

Direct exchanges dominating climate change: Blasting 90 %; Transport, freight, lorry, fleet average 7 %; Transport, freight, rail 4 %. Most sensitive exchanges (Section 6.3): Blasting [RER] (-59.0 / +173.2 %); Transport, freight, lorry, fleet average [RER] (-4.1 / +10.0 %); Transport, freight, rail [RER] (-2.1 / +5.3 %).

Independent recalculation

Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026):

Category Graph Published Graph / published
Acidification 0.1125 0.1127 0.998
Climate change-Biogenic 8.819e-04 8.819e-04 1.000
Climate change-Fossil 0.6289 0.6289 1.000
Climate change-Land use and land use change 4.074e-04 4.074e-04 1.000
Climate change 0.6301 0.6301 1.000
EF-particulate Matter 8.353e-07 8.353e-07 1.000
Ecotoxicity, freshwater_inorganics 744.2 744.2 1.000
Ecotoxicity, freshwater_organics 0.1982 0.1979 1.001
Ecotoxicity, freshwater 744.4 742.9 1.002
Eutrophication marine 0.09542 0.09542 1.000
Eutrophication, freshwater 9.659e-05 9.659e-05 1.000
Eutrophication, terrestrial 0.5823 0.5826 1.000
Human toxicity, cancer_inorganics 2.918e-09 2.917e-09 1.000
Human toxicity, cancer_organics 3.280e-10 3.280e-10 1.000
Human toxicity, cancer 3.246e-09 3.245e-09 1.000
Human toxicity, non-cancer_inorganics 4.540e-07 3.648e-07 1.244
Human toxicity, non-cancer_organics 1.295e-09 1.294e-09 1.000
Human toxicity, non-cancer 4.553e-07 3.661e-07 1.244
Ionising radiation, human health 1150 1150 1.000
Land use 14.88 13.75 1.082
Ozone depletion 1.173e-08 1.173e-08 1.000
Photochemical ozone formation - human health 0.1045 0.1045 1.000
Resource use, fossils 6.669 6.671 1.000
Resource use, minerals and metals 1.844e-06 1.770e-06 1.041
Water use 0.2578 0.2615 0.986
Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like.
Also published by BAFU for this dataset: IPCC 2021 GWP100 0.6301 kg CO2 eq; Ecological Scarcity
2021 total 1.038e+04 UBP.

Sensitivity check

One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.

Exchange Base Low / high Range Δ GWP100 (%) Δ other categories (max %)
Blasting [RER] 0.26 kg ×0.341 / ×2.93 lognormal, GSD² 3 -59.0 / +173.2 193.1 (Eutrophication, terrestrial)
Transport, freight, lorry, fleet average [RER] 0.23 tkm ×0.407 / ×2.45 lognormal, GSD² 2.5 -4.1 / +10.0 59.7 (Climate change-Land use and land use change)
Transport, freight, rail [RER] 1.37 tkm ×0.407 / ×2.45 lognormal, GSD² 2.5 -2.1 / +5.3 40.4 (Climate change-Biogenic)
Nitrate [water/River] 0.041 kg ×0.341 / ×2.93 lognormal, GSD² 3 -0.0 / +0.0 18.8 (Eutrophication marine)
From mineral extraction site [natural resource] 0.005 m2 ×0.507 / ×1.97 lognormal, GSD² 2 -0.0 / +0.0 153.9 (Land use)
Water [natural resource] 0.1 m3 ×0.341 / ×2.93 lognormal, GSD² 3 -0.0 / +0.0 3223.5 (Water use)
Selenium [water/River] 4.100e-04 kg ×0.341 / ×2.93 lognormal, GSD² 3 -0.0 / +0.0 0.0 (Human toxicity, non-cancer_inorganics)
Zinc(2+) [water/River] 8.900e-04 kg ×0.341 / ×2.93 lognormal, GSD² 3 -0.0 / +0.0 1.0 (Human toxicity, non-cancer_inorganics)
Beryllium [air/Medium stack, <150 meters / Rural (<1000 people/square mile)] 9.800e-07 kg ×0.207 / ×4.84 lognormal, GSD² 5 -0.0 / +0.0 0.6 (Human toxicity, non-cancer_inorganics)
Chloride(1-) [water/River] 0.6 kg ×0.105 / ×9.55 lognormal, GSD² 10 -0.0 / +0.0 207.8 (Ecotoxicity, freshwater_inorganics)
To mineral extraction site [natural resource] 0.005 m2 ×0.507 / ×1.97 lognormal, GSD² 2 -0.0 / +0.0 153.9 (Land use)
Cadmium [air/Medium stack, <150 meters / Rural (<1000 people/square mile)] 2.000e-06 kg ×0.207 / ×4.84 lognormal, GSD² 5 -0.0 / +0.0 12.6 (Human toxicity, non-cancer_inorganics)
Vanadium(5+) [water/River] 0.0048 kg ×0.341 / ×2.93 lognormal, GSD² 3 -0.0 / +0.0 36.8 (Human toxicity, non-cancer_inorganics)
Aluminium [water/River] 0.0023 kg ×0.341 / ×2.93 lognormal, GSD² 3 -0.0 / +0.0 2.6 (Ecotoxicity, freshwater_inorganics)
Radon-222 [air/Medium stack, <150 meters / Rural (<1000 people/square mile)] 1.000e+06 kBq ×0.105 / ×9.55 lognormal, GSD² 10 -0.0 / +0.0 847.3 (Ionising radiation, human health)

Uncertainty analysis

Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.

Comparison with other data

No other location of this dataset in the graph.

Conclusions and limitations

GWP100 0.6301 kg CO2 eq per kg (95 % interval 0.2392–2.434). Dominant contributors: Blasting 90 %; Transport, freight, lorry, fleet average 7 %; Transport, freight, rail 4 %. Most sensitive: Blasting [RER] (-59.0 / +173.2 %); Transport, freight, lorry, fleet average [RER] (-4.1 / +10.0 %); Transport, freight, rail [RER] (-2.1 / +5.3 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.

Final control

Item Status Detail
reference flow PASS production amount 1.0 kg
closure: sum of direct contributions = dataset score (all 25 categories) PASS largest relative gap 2.8e-16
independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) PASS graph / published = 1; categories within ±5 %: 22/25
every technosphere input of the EcoSpold delivery is in the graph PASS all present (bafu_links_check.py)
uncertainty declared on the direct exchanges PASS 40/40 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values
Monte Carlo 95 % interval contains the deterministic score PASS 0.6301 in [0.2392, 2.434]
time period declared PASS 2011-01/2011-12
geography is a known location code PASS GLO
sources cited PASS 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them

References

  1. Ch. Bauer, Frischknecht (2012) Umweltauswirkungen Strom. Volume: 407. PSI. Uster und Villigen, CH. Type: Separate publication Source: CD-ROM First author: Ch. Bauer Other authors: Frischknecht Year: 2012 Place of publication: Uster und Villigen, CH Publisher: PSI Volume No: 407 — published source; as declared by BAFU (not found in OpenAlex/Crossref)
  2. Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — database; dataset citation
  3. International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva.
  4. Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. (tdc-doc method reference; title, version and year to verify against the user's copy)
  5. European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra.
  6. Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236

Annex — licence and terms of use

BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.


To suggest a correction or a dataset that does not exist yet, use Propose a dataset.