Dataset documentation and final control (tdc-doc, imported mode)
Open this dataset in OpenData
Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Disposal, ventilation system for appartment buildings, PE ducts, without GHE [CH], per 1 m2. EF v3.1 climate change 0.723 kg CO2 eq (Monte Carlo 95 % interval 0.6266–0.8718). Main contributors: Disposal, building, polyethylene/polypropylene products, to … 71 %; Disposal, ventilation equipment, decentralized, 180-250 m3 16 %; Disposal, sealing tape, aluminum/PE, 50 mm wide 4 %; Disposal, overflow element, steel, approx. 40 m3/h 3 %; Disposal, air distribution housing, steel, 120 m3/h 1 %; Disposal, control and wiring, decentralized unit 1 %. Status: final control passed.
| Item | Value |
|---|---|
| Dataset name | Disposal, ventilation system for appartment buildings, PE ducts, without GHE |
| Dataset UUID / graph id | 7f3ffa87-0e85-42ed-8d39-adb8b2a5d6ec / activity:disposal_ventilation_system_for_appartment_buildings_pe_ducts_without_ghe__ch |
| Reference product, unit | Disposal, ventilation system for appartment buildings, PE ducts, without GHE, 1 m2 |
| Location | CH — Specific to the technology mix encountered in sorting plants in Switzerland. |
| Time period | 1994-01/2008-12 |
| Category | waste management / building demolition |
| Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 |
| Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) |
| Background database | BAFU 2026 v1 (graph bafuquery-db) |
| LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) |
| Status | final control passed |
| Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 |
Disposal of a ventilation system for an appartment building with a specific air flow rate of 0.92 m3/h per m2 heated gross floor area. The reference value of the inventory is 1 m2 heated gross floor area. The inventory is based on a study of an appartment building with 6 flats, a heated gross floor area of 780 m2 and a total nominal air flow of 720 m3/h. The inventory includes an average of decentral and central systems. It includes average components for air handling units, ducts (including 30mm thermal insulation where needed), air valves, roof-hoods, dampers and silencers. No insuation for fire protection or fire dampers included. The data represents horizontal ductwork mainly made of polyethylene and vertical ductwork mainly made of galvanized steel. It includes compact air handling units with cross plate heat excangers as heat recovery and a nominal air flow rate of 200-1200 m3/h per unit. No ground heat exchanger, ventilation of side rooms, cellars or car parks are included.; UUID: 7f3ffa87-0e85-42ed-8d39-adb8b2a5d6ec
This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.
Reference flow: 1 m2 of Disposal, ventilation system for appartment buildings, PE ducts, without GHE (CH). All results are given per unit of the reference flow.
Transport to dismantling facilities, machines for handling in sorting plant, electricity demand for sorting plant, final disposal of waste material. Cut-off to recycling for metals.
Disposal to a sorting plant assumed. Metal pieces, copper in cables and electronic devices are recycled, plastic parts are incinerated, inert wastes (e.g. rock wool) are landfilled.
Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).
EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.
Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).
| Exchange | Type | Location / compartment | Amount | Unit | Uncertainty | Pedigree | GWP share (%) | Notes | |
|---|---|---|---|---|---|---|---|---|---|
| Disposal, building, polyethylene/polypropylene products, to final disposal | technosphere | CH | 0.16923 | kg | lognormal, GSD² 1.24 | (2,4,2,1,1,5) | 71.0 | ██████████████ | |
| Disposal, ventilation equipment, decentralized, 180-250 m3 | technosphere | CH | 0.0038462 | p | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 16.2 | ███ | |
| Disposal, sealing tape, aluminum/PE, 50 mm wide | technosphere | CH | 0.25641 | m | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 4.4 | █ | |
| Disposal, overflow element, steel, approx. 40 m3/h | technosphere | CH | 0.023077 | p | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 2.5 | █ | |
| Disposal, air distribution housing, steel, 120 m3/h | technosphere | CH | 0.015385 | p | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 1.2 | · | |
| Disposal, control and wiring, decentralized unit | technosphere | CH | 0.0038462 | p | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 1.1 | · | |
| Disposal, outside air intake, stainless steel, DN 370 | technosphere | CH | 9.6154e-04 | p | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.8 | · | |
| Disposal, exhaust air valve, in-wall housing, plastic/steel, DN 125 | technosphere | CH | 0.023077 | p | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.6 | · | |
| Disposal, flexible duct, aluminum/PET, DN of 125 | technosphere | CH | 0.012821 | m | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.5 | · | |
| Disposal, control and wiring, central unit | technosphere | CH | 6.4103e-04 | p | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.4 | · | |
| Disposal, ventilation equipment, central, 600-1200 m3/h | technosphere | CH | 6.4103e-04 | p | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.3 | · | |
| Disposal, air filter, decentralized unit, 180-250 m3/h | technosphere | CH | 0.0076923 | p | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.3 | · | |
| Disposal, air filter, in exhaust air valve | technosphere | CH | 0.023077 | p | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.3 | · | |
| Disposal, building, bulk iron (excluding reinforcement), to sorting plant | technosphere | CH | 0.37372 | kg | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.2 | · | |
| Disposal, silencer, steel, DN 125 | technosphere | CH | 0.023077 | p | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.2 | · | |
| Disposal, insulation spiral-seam duct, rockwool, DN 400, 30 mm | technosphere | CH | 0.025641 | m | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.1 | · | |
| Disposal, silencer, steel, DN 315, 50 mm | technosphere | CH | 0.0012821 | p | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.0 | · | |
| Disposal, air filter, central unit, 600 m3/h | technosphere | CH | 0.0012821 | p | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.0 | · | |
| Disposal, exhaust air roof hood, steel, DN 400 | technosphere | CH | 9.6154e-04 | p | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.0 | · |
19 of 19 direct exchanges carry a declared pedigree, 19 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 2.0 · completeness 4.0 · temporal 1.05 · geographical 1.0 · technological 1.0 · sample size 5.0.
| Field | As declared by the publisher |
|---|---|
| Data generator / entry / validation | data generator: Alex Primas (HSLU); data entry: Alex Primas (HSLU); validation (proof reading): Alex Primas (HSLU) |
| extrapolations | none |
| sampling procedure | Waste-specific calculation based on production input data |
| production volume | na |
| uncertainty adjustments | none |
| time period comment | Amount of material investigated in 2003. Process information partly from 2008. Disposal technology mix as used in late 1990ies |
None recorded.
Per 1 m2. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.
| Impact category | Indicator | Unit | Result | 2.5 % | 97.5 % | GSD² |
|---|---|---|---|---|---|---|
| Acidification | Accumulated Exceedance (AE) | mol H+ eq | 5.032e-05 | 4.164e-05 | 8.840e-05 | 1.47 |
| Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | 2.307e-05 | 1.817e-05 | 5.193e-05 | 1.69 |
| Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | 0.723 | 0.6265 | 0.8717 | 1.18 |
| Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | 4.075e-06 | 3.582e-06 | 6.859e-06 | 1.39 |
| Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | 0.723 | 0.6266 | 0.8718 | 1.18 |
| EF-particulate Matter | Impact on human health | disease incidence | 1.320e-09 | 1.043e-09 | 2.462e-09 | 1.51 |
| Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | 0.9411 | 0.8121 | 1.398 | 1.32 |
| Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | 0.001736 | 0.001535 | 0.003354 | 1.52 |
| Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | 0.9428 | 0.8143 | 1.4 | 1.31 |
| Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | 6.107e-05 | 4.454e-05 | 1.148e-04 | 1.63 |
| Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | 8.132e-06 | 2.774e-06 | 2.128e-04 | 9.71 |
| Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | 4.730e-04 | 3.360e-04 | 9.118e-04 | 1.67 |
| Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | 6.296e-11 | 3.746e-11 | 3.077e-10 | 2.92 |
| Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | 2.046e-12 | 1.975e-12 | 3.352e-12 | 1.31 |
| Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | 6.501e-11 | 3.998e-11 | 3.109e-10 | 2.84 |
| Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | 1.327e-09 | 1.096e-09 | 6.870e-09 | 2.56 |
| Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | 1.136e-11 | 1.016e-11 | 1.695e-11 | 1.31 |
| Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | 1.338e-09 | 1.111e-09 | 6.883e-09 | 2.55 |
| Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | 0.003282 | 0.001285 | 0.01999 | 4.15 |
| Land use | Soil quality index | pt (soil quality index) | 0.1181 | 0.0717 | 0.2091 | — |
| Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | 5.397e-10 | 4.716e-10 | 9.602e-10 | 1.43 |
| Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | 1.634e-04 | 1.217e-04 | 3.006e-04 | 1.6 |
| Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | 0.2127 | 0.1867 | 0.3639 | 1.41 |
| Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | 3.008e-08 | 2.735e-08 | 6.422e-08 | 1.55 |
| Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | 0.026 | -1.621 | 0.8767 | — |
Climate change 0.723 kg CO2 eq per m2. Main contributors: Disposal, building, polyethylene/polypropylene products, to … 71 %; Disposal, ventilation equipment, decentralized, 180-250 m3 16 %; Disposal, sealing tape, aluminum/PE, 50 mm wide 4 %; Disposal, overflow element, steel, approx. 40 m3/h 3 %; Disposal, air distribution housing, steel, 120 m3/h 1 %; Disposal, control and wiring, decentralized unit 1 %.
Direct exchanges dominating climate change: Disposal, building, polyethylene/polypropylene products, to … 71 %; Disposal, ventilation equipment, decentralized, 180-250 m3 16 %; Disposal, sealing tape, aluminum/PE, 50 mm wide 4 %; Disposal, overflow element, steel, approx. 40 m3/h 3 %; Disposal, air distribution housing, steel, 120 m3/h 1 %; Disposal, control and wiring, decentralized unit 1 %. Most sensitive exchanges (Section 6.3): Disposal, building, polyethylene/polypropylene products, to final disposal [CH] (-13.5 / +16.7 %); Disposal, ventilation equipment, decentralized, 180-250 m3 [CH] (-3.1 / +3.8 %); Disposal, sealing tape, aluminum/PE, 50 mm wide [CH] (-0.8 / +1.0 %).
Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026):
| Category | Graph | Published | Graph / published |
|---|---|---|---|
| Acidification | 5.032e-05 | 1.194e-04 | 0.421 |
| Climate change-Biogenic | 2.307e-05 | 2.307e-05 | 1.000 |
| Climate change-Fossil | 0.723 | 0.723 | 1.000 |
| Climate change-Land use and land use change | 4.075e-06 | 4.075e-06 | 1.000 |
| Climate change | 0.723 | 0.723 | 1.000 |
| EF-particulate Matter | 1.320e-09 | 1.320e-09 | 1.000 |
| Ecotoxicity, freshwater_inorganics | 0.9411 | 0.9803 | 0.960 |
| Ecotoxicity, freshwater_organics | 0.001736 | 0.00173 | 1.004 |
| Ecotoxicity, freshwater | 0.9428 | 0.9819 | 0.960 |
| Eutrophication marine | 6.107e-05 | 6.107e-05 | 1.000 |
| Eutrophication, freshwater | 8.132e-06 | 8.132e-06 | 1.000 |
| Eutrophication, terrestrial | 4.730e-04 | 6.058e-04 | 0.781 |
| Human toxicity, cancer_inorganics | 6.296e-11 | 6.294e-11 | 1.000 |
| Human toxicity, cancer_organics | 2.046e-12 | 2.046e-12 | 1.000 |
| Human toxicity, cancer | 6.501e-11 | 6.498e-11 | 1.000 |
| Human toxicity, non-cancer_inorganics | 1.327e-09 | 1.315e-09 | 1.009 |
| Human toxicity, non-cancer_organics | 1.136e-11 | 1.136e-11 | 1.000 |
| Human toxicity, non-cancer | 1.338e-09 | 1.326e-09 | 1.009 |
| Ionising radiation, human health | 0.003282 | 0.003282 | 1.000 |
| Land use | 0.1181 | 0.07471 | 1.581 |
| Ozone depletion | 5.397e-10 | 5.397e-10 | 1.000 |
| Photochemical ozone formation - human health | 1.634e-04 | 1.634e-04 | 1.000 |
| Resource use, fossils | 0.2127 | 0.2127 | 1.000 |
| Resource use, minerals and metals | 3.008e-08 | 2.322e-08 | 1.295 |
| Water use | 0.026 | 0.02609 | 0.996 |
| Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | |||
| Also published by BAFU for this dataset: IPCC 2021 GWP100 0.723 kg CO2 eq; Ecological Scarcity | |||
| 2021 total 781 UBP. |
One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.
| Exchange | Base | Low / high | Range | Δ GWP100 (%) | Δ other categories (max %) |
|---|---|---|---|---|---|
| Disposal, building, polyethylene/polypropylene products, to final disposal [CH] | 0.1692 kg | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -13.5 / +16.7 | 16.7 (Climate change-Fossil) |
| Disposal, ventilation equipment, decentralized, 180-250 m3 [CH] | 0.003846 p | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -3.1 / +3.8 | 6.1 (Ecotoxicity, freshwater_inorganics) |
| Disposal, sealing tape, aluminum/PE, 50 mm wide [CH] | 0.2564 m | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.8 / +1.0 | 14.2 (Human toxicity, cancer_inorganics) |
| Disposal, overflow element, steel, approx. 40 m3/h [CH] | 0.02308 p | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.5 / +0.6 | 1.0 (Water use) |
| Disposal, air distribution housing, steel, 120 m3/h [CH] | 0.01538 p | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.2 / +0.3 | 2.4 (Eutrophication marine) |
| Disposal, control and wiring, decentralized unit [CH] | 0.003846 p | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.2 / +0.3 | 5.7 (Water use) |
| Disposal, outside air intake, stainless steel, DN 370 [CH] | 9.615e-04 p | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.2 / +0.2 | 0.4 (Ionising radiation, human health) |
| Disposal, exhaust air valve, in-wall housing, plastic/steel, DN 125 [CH] | 0.02308 p | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.1 / +0.1 | 7.5 (Water use) |
| Disposal, flexible duct, aluminum/PET, DN of 125 [CH] | 0.01282 m | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.1 / +0.1 | 0.2 (Human toxicity, non-cancer_inorganics) |
| Disposal, control and wiring, central unit [CH] | 6.410e-04 p | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.1 / +0.1 | 2.5 (Water use) |
| Disposal, ventilation equipment, central, 600-1200 m3/h [CH] | 6.410e-04 p | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.1 / +0.1 | 1.7 (Eutrophication, freshwater) |
| Disposal, air filter, decentralized unit, 180-250 m3/h [CH] | 0.007692 p | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.1 / +0.1 | 0.1 (Human toxicity, non-cancer_inorganics) |
| Disposal, air filter, in exhaust air valve [CH] | 0.02308 p | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.1 / +0.1 | 0.1 (Human toxicity, non-cancer_inorganics) |
| Disposal, building, bulk iron (excluding reinforcement), to sorting plant [CH] | 0.3737 kg | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.0 / +0.0 | 5.2 (Ionising radiation, human health) |
| Disposal, silencer, steel, DN 125 [CH] | 0.02308 p | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.0 / +0.0 | 7.2 (Eutrophication, freshwater) |
Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.
No other location of this dataset in the graph.
GWP100 0.723 kg CO2 eq per m2 (95 % interval 0.6266–0.8718). Dominant contributors: Disposal, building, polyethylene/polypropylene products, to … 71 %; Disposal, ventilation equipment, decentralized, 180-250 m3 16 %; Disposal, sealing tape, aluminum/PE, 50 mm wide 4 %; Disposal, overflow element, steel, approx. 40 m3/h 3 %; Disposal, air distribution housing, steel, 120 m3/h 1 %; Disposal, control and wiring, decentralized unit 1 %. Most sensitive: Disposal, building, polyethylene/polypropylene products, to final disposal [CH] (-13.5 / +16.7 %); Disposal, ventilation equipment, decentralized, 180-250 m3 [CH] (-3.1 / +3.8 %); Disposal, sealing tape, aluminum/PE, 50 mm wide [CH] (-0.8 / +1.0 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.
| Item | Status | Detail |
|---|---|---|
| reference flow | PASS | production amount 1.0 m2 |
| closure: sum of direct contributions = dataset score (all 25 categories) | PASS | largest relative gap 4.6e-16 |
| independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) | PASS | graph / published = 1; categories within ±5 %: 21/25 |
| every technosphere input of the EcoSpold delivery is in the graph | PASS | all present (bafu_links_check.py) |
| uncertainty declared on the direct exchanges | PASS | 19/19 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values |
| Monte Carlo 95 % interval contains the deterministic score | PASS | 0.723 in [0.6266, 0.8718] |
| time period declared | PASS | 1994-01/2008-12 |
| geography is a known location code | PASS | CH |
| sources cited | PASS | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them |
BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.
To suggest a correction or a dataset that does not exist yet, use Propose a dataset.