Table of Contents

Radioactive waste, in interim storage conditioning — CH

Dataset documentation and final control (tdc-doc, imported mode)
Open this dataset in OpenData

Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Radioactive waste, in interim storage conditioning [CH], per 1 m3. EF v3.1 climate change 6.345e+04 kg CO2 eq (Monte Carlo 95 % interval 4.089e+04–1.187e+05). Main contributors: Electricity, medium voltage, at grid 73 %; Carbon Dioxide (fossil) 18 %; Light fuel oil, at regional storage 5 %; Radioactive waste, in final repository for nuclear waste LLW 3 %. Status: final control passed.
Item Value
Dataset name Radioactive waste, in interim storage conditioning
Dataset UUID / graph id 89bbba3a-3936-4dce-9d7d-c2c29d555202 / activity:radioactive_waste_in_interim_storage_conditioning__ch
Reference product, unit Radioactive waste, in interim storage conditioning, 1 m3
Location CH
Time period 2000-01/2000-12
Category nuclear waste / unspecified
Source database BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1
Publisher Swiss Federal Office for the Environment (FOEN/BAFU)
Background database BAFU 2026 v1 (graph bafuquery-db)
LCIA method EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix)
Status final control passed
Documented by tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17

Introduction

The module describes the plasma torch incineration of low radioactive level waste, operating at very high temperature. Five cubic meter of waste per year are assumed to be produced by incineration. The emissions from the design have been included. Therefore the oil consumption has been modeled with oil from regional storage and not with oil burned in furnace, to prevent double counting. Emissions to air expected by the designer are used, and the uncertainty estimated on the basis of the range with the maximum considered in desing. Particles are assumed to be below 2.5 micrometer due to the use of several HEPA filters. In 2003 the torch is not yet operating. Maximum designed emissions to water are given.; UUID: 89bbba3a-3936-4dce-9d7d-c2c29d555202

This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.

Goal and scope

Function, functional unit and reference flow

Reference flow: 1 m3 of Radioactive waste, in interim storage conditioning (CH). All results are given per unit of the reference flow.

System boundary

The module requires input of service from the final repository for low active level waste, i.e. the take over of the conditioned waste. The module describes the plasma torch incineration of low radioactive level waste, operating at very high temperature. The radioactive and non radioactive emissions to air and water expected from the design have been included. The electricity use, light oil consumption, material consumption, and related transport requirements are added. The values are normalized by the incinerated waste volume.

Technology

Information regards design in mid 1990s.

Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).

LCIA method

EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.

Life cycle inventory

Inventory table

Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).

Exchange Type Location / compartment Amount Unit Uncertainty Pedigree GWP share (%) Notes
Electricity, medium voltage, at grid technosphere CH 5.2000e+05 kWh lognormal, GSD² 2 — 73.4 ███████████████
Light fuel oil, at regional storage technosphere CH 3600 kg lognormal, GSD² 2 — 5.1 █
Radioactive waste, in final repository for nuclear waste LLW technosphere CH 1 m3 none declared: tdc-doc default ±50 % — 2.5 █
Ammonia, liquid, at regional storehouse technosphere RER 180 kg lognormal, GSD² 1.3 — 0.6 ·
Transport, freight, lorry, 16t-32t gross weight, fleet average technosphere CH 1530 tkm lognormal, GSD² 2.1 — 0.4 ·
Sulphuric acid, liquid, at plant technosphere RER 18 kg lognormal, GSD² 1.3 — 0.0 ·
Transport, freight, rail technosphere RER 119 tkm lognormal, GSD² 2.1 — 0.0 ·
Carbon Dioxide (fossil) elementary air/Medium stack, <150 meters / Rural (<… 11400 kg lognormal, GSD² 1.2 — 18.0 ████
Radioactive Species, Nuclides, Unspecified elementary water/Surface water 600 kBq lognormal, GSD² 5 — 0.0 ·
Carbon-14 elementary air/Medium stack, <150 meters / Rural (<… 1.6600e+06 kBq lognormal, GSD² 2 — 0.0 ·
Mercury elementary water/River 2.4000e-04 kg lognormal, GSD² 5 — 0.0 ·
Nitrogen Oxides, CH elementary air/Medium stack, <150 meters / Rural (<… 21.6 kg lognormal, GSD² 1.3 — 0.0 ·
Waste Heat elementary air/Medium stack, <150 meters / Rural (<… 2.5000e+06 MJ lognormal, GSD² 2 — 0.0 ·
Hydrocarbons (unspecified) elementary water/River 0.24 kg lognormal, GSD² 5 — 0.0 ·
Hydrogen Chloride elementary air/Medium stack, <150 meters / Rural (<… 0.81 kg lognormal, GSD² 4 — 0.0 ·
Cadmium(2+) elementary water/River 0.0024 kg lognormal, GSD² 5 — 0.0 ·
Hydrogen-3 elementary air/Medium stack, <150 meters / Rural (<… 3.0400e+06 kBq lognormal, GSD² 2 — 0.0 ·
Iron, ion elementary water/River 0.048 kg lognormal, GSD² 5 — 0.0 ·
Cobalt elementary water/River 0.012 kg lognormal, GSD² 5 — 0.0 ·
Zinc(2+) elementary water/River 0.048 kg lognormal, GSD² 5 — 0.0 ·
Particles (PM2.5) elementary air/Medium stack, <150 meters / Rural (<… 0.0018 kg lognormal, GSD² 5 — 0.0 ·
Non-methane Volatile Organic Compounds elementary air/Medium stack, <150 meters / Rural (<… 0.0036 kg lognormal, GSD² 5 — 0.0 ·
Cadmium elementary air/Medium stack, <150 meters / Rural (<… 5.4000e-06 kg lognormal, GSD² 20 — 0.0 ·
2,3,7,8-tetrachlorodibenzo-p-dioxin elementary air/Medium stack, <150 meters / Rural (<… 3.6000e-11 kg lognormal, GSD² 5 — 0.0 ·
Chromium(3+) elementary water/River 0.048 kg lognormal, GSD² 5 — 0.0 ·
Ammonia, CH elementary air/Medium stack, <150 meters / Rural (<… 1.44 kg lognormal, GSD² 1.2 — 0.0 ·
Aluminium elementary water/River 0.24 kg lognormal, GSD² 5 — 0.0 ·
Nickel(2+) elementary water/River 0.048 kg lognormal, GSD² 5 — 0.0 ·
Chromium(6+) elementary water/River 0.0024 kg lognormal, GSD² 5 — 0.0 ·
Sulfur Dioxide, CH elementary air/Medium stack, <150 meters / Rural (<… 5.04 kg lognormal, GSD² 2 — 0.0 ·
Lead elementary air/Medium stack, <150 meters / Rural (<… 2.2000e-04 kg lognormal, GSD² 20 — 0.0 ·
Chlorinated Solvents, Unspecified elementary water/Surface water 0.0024 kg lognormal, GSD² 5 — 0.0 ·
Copper, ion elementary water/River 0.012 kg lognormal, GSD² 5 — 0.0 ·
Lead elementary water/River 0.012 kg lognormal, GSD² 5 — 0.0 ·

Data quality

0 of 34 direct exchanges carry a declared pedigree, 33 carry a distribution.

Field As declared by the publisher
Data generator / entry / validation data generator: Roberto Dones; data entry: Roberto Dones; validation (proof reading): Roberto Dones
extrapolations none
sampling procedure Literature
production volume na
uncertainty adjustments none
validation details Proof reading validation: passed; Other validation: for final run August 2003;
time period comment undefined

Data gaps, proxies and assumptions

Item Class Value used Reason Effect
1 exchange(s) without declared uncertainty uncertainty fixed in the Monte Carlo the publisher declares no distribution ±50 % in the sensitivity check (Section 6.3)

Life cycle impact assessment (EF v3.1)

Per 1 m3. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.

Impact category Indicator Unit Result 2.5 % 97.5 % GSD²
Acidification Accumulated Exceedance (AE) mol H+ eq 103.1 68.17 206.7 1.78
Climate change-Biogenic Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 1286 573.6 2881 2.27
Climate change-Fossil Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 6.201e+04 4.028e+04 1.156e+05 1.73
Climate change-Land use and land use change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 154.7 68.1 328.7 2.25
Climate change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 6.345e+04 4.089e+04 1.187e+05 1.73
EF-particulate Matter Impact on human health disease incidence 0.002323 0.001257 0.005843 2.17
Ecotoxicity, freshwater_inorganics Comparative Toxic Unit for ecosystems (CTUe) CTUe 1.713e+05 1.146e+05 5.345e+05 2.21
Ecotoxicity, freshwater_organics Comparative Toxic Unit for ecosystems (CTUe) CTUe 3583 2542 1.014e+04 2.05
Ecotoxicity, freshwater Comparative Toxic Unit for ecosystems (CTUe) CTUe 1.749e+05 1.167e+05 5.406e+05 2.2
Eutrophication marine Fraction of nutrients reaching marine end compartment (N) kg N eq 50.18 32.99 95.83 1.75
Eutrophication, freshwater Fraction of nutrients reaching freshwater end compartment (P) kg P eq 37.83 15.12 163.7 3.36
Eutrophication, terrestrial Accumulated Exceedance (AE) mol N eq 374.4 270.2 693.3 1.63
Human toxicity, cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 9.405e-06 6.806e-06 3.054e-05 2.15
Human toxicity, cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 2.092e-05 1.014e-05 4.784e-05 2.26
Human toxicity, cancer Comparative Toxic Unit for human (CTUh) CTUh 3.033e-05 1.779e-05 7.320e-05 2.11
Human toxicity, non-cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 3.946e-04 2.974e-04 0.00137 2.19
Human toxicity, non-cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 2.669e-05 1.813e-05 6.333e-05 1.92
Human toxicity, non-cancer Comparative Toxic Unit for human (CTUh) CTUh 4.213e-04 3.145e-04 0.001429 2.16
Ionising radiation, human health Human exposure efficiency relative to U235 kBq U235 eq 1.696e+07 8.842e+06 3.432e+07 1.98
Land use Soil quality index pt (soil quality index) 7.403e+05 3.470e+05 1.829e+06 2.33
Ozone depletion Ozone Depletion Potential (ODP) kg CFC-11 eq 0.005827 0.003089 0.0125 2.06
Photochemical ozone formation - human health Tropospheric ozone concentration increase kg NMVOC eq 148.6 107.9 306.2 1.7
Resource use, fossils Abiotic resource depletion fossil fuels (ADP-fossil) MJ 3.713e+06 1.898e+06 7.634e+06 2.04
Resource use, minerals and metals Abiotic resource depletion (ADP ultimate reserve) kg Sb eq 0.1583 0.09854 0.4069 2.11
Water use User deprivation potential (deprivation-weighted water consumption) m3 world eq deprived 3.083e+04 -1.138e+08 6.861e+07 —

Climate change 6.345e+04 kg CO2 eq per m3. Main contributors: Electricity, medium voltage, at grid 73 %; Carbon Dioxide (fossil) 18 %; Light fuel oil, at regional storage 5 %; Radioactive waste, in final repository for nuclear waste LLW 3 %.

Interpretation

Significant issues

Direct exchanges dominating climate change: Electricity, medium voltage, at grid 73 %; Carbon Dioxide (fossil) 18 %; Light fuel oil, at regional storage 5 %; Radioactive waste, in final repository for nuclear waste LLW 3 %. Most sensitive exchanges (Section 6.3): Electricity, medium voltage, at grid [CH] (-36.2 / +71.3 %); Light fuel oil, at regional storage [CH] (-2.5 / +5.0 %); Carbon Dioxide (fossil) [air/Medium stack, <150 meters / Rural (<1000 people/square mile)] (-2.9 / +3.5 %).

Independent recalculation

Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026):

Category Graph Published Graph / published
Acidification 103.1 135.7 0.760
Climate change-Biogenic 1286 1286 1.000
Climate change-Fossil 6.201e+04 6.201e+04 1.000
Climate change-Land use and land use change 154.7 154.7 1.000
Climate change 6.345e+04 6.345e+04 1.000
EF-particulate Matter 0.002323 0.002323 1.000
Ecotoxicity, freshwater_inorganics 1.713e+05 1.820e+05 0.941
Ecotoxicity, freshwater_organics 3583 3319 1.079
Ecotoxicity, freshwater 1.749e+05 1.851e+05 0.945
Eutrophication marine 50.18 50.02 1.003
Eutrophication, freshwater 37.83 37.83 1.000
Eutrophication, terrestrial 374.4 426.3 0.878
Human toxicity, cancer_inorganics 9.405e-06 8.788e-06 1.070
Human toxicity, cancer_organics 2.092e-05 2.092e-05 1.000
Human toxicity, cancer 3.033e-05 2.971e-05 1.021
Human toxicity, non-cancer_inorganics 3.946e-04 3.635e-04 1.086
Human toxicity, non-cancer_organics 2.669e-05 2.668e-05 1.001
Human toxicity, non-cancer 4.213e-04 3.902e-04 1.080
Ionising radiation, human health 1.696e+07 1.696e+07 1.000
Land use 7.403e+05 5.975e+05 1.239
Ozone depletion 0.005827 0.005827 1.000
Photochemical ozone formation - human health 148.6 148.6 1.000
Resource use, fossils 3.713e+06 3.713e+06 1.000
Resource use, minerals and metals 0.1583 0.155 1.021
Water use 3.083e+04 3.423e+04 0.901
Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like.
Also published by BAFU for this dataset: IPCC 2021 GWP100 6.342e+04 kg CO2 eq; Ecological Scarcity
2021 total 2.515e+08 UBP.

Sensitivity check

One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.

Exchange Base Low / high Range Δ GWP100 (%) Δ other categories (max %)
Electricity, medium voltage, at grid [CH] 5.200e+05 kWh ×0.507 / ×1.97 lognormal, GSD² 2 -36.2 / +71.3 96.6 (Climate change-Biogenic)
Light fuel oil, at regional storage [CH] 3600 kg ×0.507 / ×1.97 lognormal, GSD² 2 -2.5 / +5.0 28.8 (Ecotoxicity, freshwater_organics)
Carbon Dioxide (fossil) [air/Medium stack, <150 meters / Rural (<1000 people/square mile)] 1.14e+04 kg ×0.836 / ×1.2 lognormal, GSD² 1.2 -2.9 / +3.5 3.6 (Climate change-Fossil)
Radioactive waste, in final repository for nuclear waste LLW [CH] 1 m3 ×0.5 / ×1.5 none declared: tdc-doc default ±50 % -1.3 / +1.3 5.6 (Human toxicity, non-cancer_organics)
Transport, freight, lorry, 16t-32t gross weight, fleet average [CH] 1530 tkm ×0.483 / ×2.07 lognormal, GSD² 2.1 -0.2 / +0.4 1.6 (Ecotoxicity, freshwater_organics)
Ammonia, liquid, at regional storehouse [RER] 180 kg ×0.773 / ×1.29 lognormal, GSD² 1.3 -0.1 / +0.2 0.3 (EF-particulate Matter)
Transport, freight, rail [RER] 119 tkm ×0.483 / ×2.07 lognormal, GSD² 2.1 -0.0 / +0.0 0.0 (Human toxicity, non-cancer_organics)
Sulphuric acid, liquid, at plant [RER] 18 kg ×0.773 / ×1.29 lognormal, GSD² 1.3 -0.0 / +0.0 0.0 (Acidification)
Carbon-14 [air/Medium stack, <150 meters / Rural (<1000 people/square mile)] 1.660e+06 kBq ×0.507 / ×1.97 lognormal, GSD² 2 -0.0 / +0.0 95.2 (Ionising radiation, human health)
Mercury [water/River] 2.400e-04 kg ×0.207 / ×4.84 lognormal, GSD² 5 -0.0 / +0.0 0.4 (Human toxicity, non-cancer_inorganics)
Nitrogen Oxides, CH [air/Medium stack, <150 meters / Rural (<1000 people/square mile) [CH]… 21.6 kg ×0.773 / ×1.29 lognormal, GSD² 1.3 -0.0 / +0.0 5.5 (Eutrophication, terrestrial)
Hydrocarbons (unspecified) [water/River] 0.24 kg ×0.207 / ×4.84 lognormal, GSD² 5 -0.0 / +0.0 20.6 (Ecotoxicity, freshwater_organics)
Hydrogen Chloride [air/Medium stack, <150 meters / Rural (<1000 people/square mile)] 0.81 kg ×0.257 / ×3.89 lognormal, GSD² 4 -0.0 / +0.0 0.0 (Ecotoxicity, freshwater_inorganics)
Cadmium(2+) [water/River] 0.0024 kg ×0.207 / ×4.84 lognormal, GSD² 5 -0.0 / +0.0 3.6 (Ecotoxicity, freshwater_inorganics)
Hydrogen-3 [air/Medium stack, <150 meters / Rural (<1000 people/square mile)] 3.040e+06 kBq ×0.507 / ×1.97 lognormal, GSD² 2 -0.0 / +0.0 0.0 (Ionising radiation, human health)

Uncertainty analysis

Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.

Comparison with other data

No other location of this dataset in the graph.

Conclusions and limitations

GWP100 6.345e+04 kg CO2 eq per m3 (95 % interval 4.089e+04–1.187e+05). Dominant contributors: Electricity, medium voltage, at grid 73 %; Carbon Dioxide (fossil) 18 %; Light fuel oil, at regional storage 5 %; Radioactive waste, in final repository for nuclear waste LLW 3 %. Most sensitive: Electricity, medium voltage, at grid [CH] (-36.2 / +71.3 %); Light fuel oil, at regional storage [CH] (-2.5 / +5.0 %); Carbon Dioxide (fossil) [air/Medium stack, <150 meters / Rural (<1000 people/square mile)] (-2.9 / +3.5 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.

Final control

Item Status Detail
reference flow PASS production amount 1.0 m3
closure: sum of direct contributions = dataset score (all 25 categories) PASS largest relative gap 3.8e-16
independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) PASS graph / published = 1; categories within ±5 %: 15/25
every technosphere input of the EcoSpold delivery is in the graph PASS all present (bafu_links_check.py)
uncertainty declared on the direct exchanges PASS 33/34 exchanges carry a distribution (97 %); the others enter the Monte Carlo as fixed values
Monte Carlo 95 % interval contains the deterministic score PASS 6.345e+04 in [4.089e+04, 1.187e+05]
time period declared PASS 2000-01/2000-12
geography is a known location code PASS CH
sources cited PASS 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them

References

  1. Dones, R., Doka G. (2009) Kernenergie. Sachbilanzen von Energiesystemen. Final report No. 6 ecoinvent v2.1. Editors: Bauer C.. Volume: 6. Swiss Centre for LCI, PSI. Dübendorf and Villigen, CH. Type: Measurement on site Source: CD-ROM First author: Dones, R. Other authors: Doka G. Year: 2009 Name of editors: Bauer C. Title of anthology: Sachbilanzen von Energiesystemen. Final report No. 6 ecoinvent… — published source; as declared by BAFU (not found in OpenAlex/Crossref)
  2. Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — database; dataset citation
  3. International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva.
  4. Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. (tdc-doc method reference; title, version and year to verify against the user's copy)
  5. European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra.
  6. Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236

Annex — licence and terms of use

BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.


To suggest a correction or a dataset that does not exist yet, use Propose a dataset.