Table of Contents

Heat pump, air-water, 7kW — RER

Dataset documentation and final control (tdc-doc, imported mode)
Open this dataset in OpenData

Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Heat pump, air-water, 7kW [RER], per 1 p. EF v3.1 climate change 1634 kg CO2 eq (Monte Carlo 95 % interval 1458–2308). Main contributors: Steel, low-alloyed, at plant 19 %; Aluminium, primary, at plant 18 %; Electronic component, unspecified, at plant 17 %; Pentafluoroethane 12 %; Electricity, medium voltage, production ENTSO-E, at grid 9 %; Natural gas, burned in industrial furnace 1MWth 7 %. Status: final control passed.
Item Value
Dataset name Heat pump, air-water, 7kW
Dataset UUID / graph id 8cddf964-9457-3e49-90bc-a607d4f7b4c5 / activity:heat_pump_air_water_7kw__rer
Reference product, unit Heat pump, air-water, 7kW, 1 p
Location RER — Data apply to the supply in Switzerland.
Time period 2019-01/2020-12
Category heat / heat pumps\heating systems
Source database BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1
Publisher Swiss Federal Office for the Environment (FOEN/BAFU)
Background database BAFU 2026 v1 (graph bafuquery-db)
LCIA method EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix)
Status final control passed
Documented by tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17

Introduction

Inventory for the production of an air-water heat pump, 7kW with a life time of 20 years.; Synonyms: Wärmepumpe mit Wärmetauscher Luft/ Wasser 7kW; UUID: 8cddf964-9457-3e49-90bc-a607d4f7b4c5

This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.

Goal and scope

Function, functional unit and reference flow

Reference flow: 1 p of Heat pump, air-water, 7kW (RER). All results are given per unit of the reference flow.

System boundary

Infrastructure of the air-water heat pump including all material inputs (pipes, air heat exchanger, coolant) and also the energy use for the construction of the heat pump components.

Technology

average technology available on market

Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).

LCIA method

EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.

Life cycle inventory

Inventory table

Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).

Exchange Type Location / compartment Amount Unit Uncertainty Pedigree GWP share (%) Notes
Steel, low-alloyed, at plant technosphere RER 146.9 kg lognormal, GSD² 1.4 — 19.2 ████
Aluminium, primary, at plant technosphere RER 32.3 kg lognormal, GSD² 1.4 — 17.6 ████
Electronic component, unspecified, at plant technosphere GLO 1.5 kg lognormal, GSD² 1.4 — 16.6 ███
Electricity, medium voltage, production ENTSO-E, at grid technosphere ENTSO-E 557.2 kWh lognormal, GSD² 1.55 — 9.3 ██
Natural gas, burned in industrial furnace 1MWth technosphere CH 1498.4 MJ lognormal, GSD² 1.22 — 7.0 █
Copper, at regional storage technosphere RER 59.2 kg lognormal, GSD² 1.4 — 5.8 █
Tube insulation, elastomere, at plant technosphere DE 12.1 kg lognormal, GSD² 1.4 — 3.3 █
Disposal, plastics, mixture, 15.3% water, to municipal incineration technosphere CH 13.3 kg lognormal, GSD² 1.4 — 1.9 ·
Heat, biomethane, at industrial furnace 1MW technosphere CH 704.37 MJ lognormal, GSD² 1.55 — 1.7 ·
Trifluoromethane, at plant technosphere GLO 1.75 kg lognormal, GSD² 1.62 — 1.0 ·
1,1-difluoroethane, HFC-152a, at plant technosphere US 1.75 kg lognormal, GSD² 1.62 — 0.5 ·
Light fuel oil, burned in industrial furnace 1MW, non-modulating technosphere RER 47.296 MJ lognormal, GSD² 1.22 — 0.3 ·
Rock wool, at plant technosphere CH 4 kg lognormal, GSD² 1.31 — 0.3 ·
Lubricating oil, at plant technosphere RER 2.2 kg lognormal, GSD² 1.55 — 0.2 ·
Heat, mixed chips from forest, at furnace 1000kW technosphere CH 571 MJ lognormal, GSD² 1.55 — 0.2 ·
Polyvinylchloride, bulk polymerised, at plant technosphere RER 1.2 kg lognormal, GSD² 1.4 — 0.2 ·
Transport, freight, rail technosphere RER 154 tkm lognormal, GSD² 2.34 — 0.2 ·
Transport, freight, lorry, 16t-32t gross weight, fleet average technosphere CH 12.8 tkm lognormal, GSD² 2.34 — 0.1 ·
Pentafluoroethane elementary air/Ground level / Urban (>1000 people/s… 0.0525 kg lognormal, GSD² 1.56 — 12.0 ██
Difluoromethane elementary air/Ground level / Urban (>1000 people/s… 0.0525 kg lognormal, GSD² 1.56 — 2.5 ·
Waste Heat elementary air/Ground level / Urban (>1000 people/s… 2005.9 MJ lognormal, GSD² 1.4 — 0.0 ·
Industrial area elementary natural resource 8.26 m2.a lognormal, GSD² 1.57 — 0.0 ·
Industrial area elementary natural resource 2.28 m2.a lognormal, GSD² 1.57 — 0.0 ·
Water elementary natural resource 0.95 m3 lognormal, GSD² 1.4 — 0.0 ·

Data quality

0 of 24 direct exchanges carry a declared pedigree, 24 carry a distribution.

Field As declared by the publisher
Data generator / entry / validation data generator: Cyrill Kern (CARBOTECH); data entry: Thomas Kaegi (CARBOTECH); validation (proof reading): Andy Spoerri (EBP)
extrapolations
sampling procedure Data provided by manufacturer
production volume na
uncertainty adjustments none
validation details Proof reading validation: 19.02.2021; Other validation: Z:\Schreibtisch\WinShare\BAFU Heizsysteme\A_zum konvertieren\WP[EcoSpold_heat pump, air-water _NEU 7kW.xlsx]X-Process;
time period comment undefined

Data gaps, proxies and assumptions

None recorded.

Life cycle impact assessment (EF v3.1)

Per 1 p. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.

Impact category Indicator Unit Result 2.5 % 97.5 % GSD²
Acidification Accumulated Exceedance (AE) mol H+ eq 13.88 11.1 20.29 1.37
Climate change-Biogenic Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 21.97 13.95 39.89 1.68
Climate change-Fossil Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 1611 1432 2287 1.26
Climate change-Land use and land use change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.8658 0.6674 1.386 1.45
Climate change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 1634 1458 2308 1.26
EF-particulate Matter Impact on human health disease incidence 8.599e-05 7.667e-05 1.339e-04 1.33
Ecotoxicity, freshwater_inorganics Comparative Toxic Unit for ecosystems (CTUe) CTUe 7546 6808 1.905e+04 1.72
Ecotoxicity, freshwater_organics Comparative Toxic Unit for ecosystems (CTUe) CTUe 245.9 211.3 467.8 1.57
Ecotoxicity, freshwater Comparative Toxic Unit for ecosystems (CTUe) CTUe 7792 7063 1.952e+04 1.7
Eutrophication marine Fraction of nutrients reaching marine end compartment (N) kg N eq 1.761 1.439 3.287 1.55
Eutrophication, freshwater Fraction of nutrients reaching freshwater end compartment (P) kg P eq 5.212 3.103 38.64 3.53
Eutrophication, terrestrial Accumulated Exceedance (AE) mol N eq 17.22 13.96 28.98 1.47
Human toxicity, cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 1.885e-06 1.669e-06 5.331e-06 1.87
Human toxicity, cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 6.255e-07 5.258e-07 1.100e-06 1.47
Human toxicity, cancer Comparative Toxic Unit for human (CTUh) CTUh 2.511e-06 2.325e-06 6.133e-06 1.7
Human toxicity, non-cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 1.455e-04 1.167e-04 4.236e-04 1.97
Human toxicity, non-cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 1.015e-05 6.090e-06 2.119e-05 1.84
Human toxicity, non-cancer Comparative Toxic Unit for human (CTUh) CTUh 1.556e-04 1.289e-04 4.367e-04 1.92
Ionising radiation, human health Human exposure efficiency relative to U235 kBq U235 eq 534.1 181.3 3273 4.44
Land use Soil quality index pt (soil quality index) 1.549e+04 1.329e+04 2.451e+04 1.36
Ozone depletion Ozone Depletion Potential (ODP) kg CFC-11 eq 0.002293 0.001016 0.005668 2.36
Photochemical ozone formation - human health Tropospheric ozone concentration increase kg NMVOC eq 5.932 5.177 9.587 1.38
Resource use, fossils Abiotic resource depletion fossil fuels (ADP-fossil) MJ 1.97e+04 1.738e+04 3.13e+04 1.35
Resource use, minerals and metals Abiotic resource depletion (ADP ultimate reserve) kg Sb eq 0.3581 0.1972 0.9267 2.22
Water use User deprivation potential (deprivation-weighted water consumption) m3 world eq deprived 186.2 -5.085e+05 2.699e+05 —

Climate change 1634 kg CO2 eq per p. Main contributors: Steel, low-alloyed, at plant 19 %; Aluminium, primary, at plant 18 %; Electronic component, unspecified, at plant 17 %; Pentafluoroethane 12 %; Electricity, medium voltage, production ENTSO-E, at grid 9 %; Natural gas, burned in industrial furnace 1MWth 7 %.

Interpretation

Significant issues

Direct exchanges dominating climate change: Steel, low-alloyed, at plant 19 %; Aluminium, primary, at plant 18 %; Electronic component, unspecified, at plant 17 %; Pentafluoroethane 12 %; Electricity, medium voltage, production ENTSO-E, at grid 9 %; Natural gas, burned in industrial furnace 1MWth 7 %. Most sensitive exchanges (Section 6.3): Steel, low-alloyed, at plant [RER] (-5.4 / +7.4 %); Aluminium, primary, at plant [RER] (-4.9 / +6.8 %); Electronic component, unspecified, at plant [GLO] (-4.6 / +6.4 %).

Independent recalculation

Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026):

Category Graph Published Graph / published
Acidification 13.88 15.17 0.914
Climate change-Biogenic 21.97 21.97 1.000
Climate change-Fossil 1611 1611 1.000
Climate change-Land use and land use change 0.8658 0.8658 1.000
Climate change 1634 1634 1.000
EF-particulate Matter 8.599e-05 8.599e-05 1.000
Ecotoxicity, freshwater_inorganics 7546 7834 0.963
Ecotoxicity, freshwater_organics 245.9 233.5 1.053
Ecotoxicity, freshwater 7792 7971 0.977
Eutrophication marine 1.761 1.761 1.000
Eutrophication, freshwater 5.212 5.212 1.000
Eutrophication, terrestrial 17.22 18.11 0.951
Human toxicity, cancer_inorganics 1.885e-06 1.874e-06 1.006
Human toxicity, cancer_organics 6.255e-07 6.255e-07 1.000
Human toxicity, cancer 2.511e-06 2.500e-06 1.004
Human toxicity, non-cancer_inorganics 1.455e-04 1.448e-04 1.004
Human toxicity, non-cancer_organics 1.015e-05 1.015e-05 1.000
Human toxicity, non-cancer 1.556e-04 1.550e-04 1.004
Ionising radiation, human health 534.1 534.1 1.000
Land use 1.549e+04 1.088e+04 1.424
Ozone depletion 0.002293 0.002293 1.000
Photochemical ozone formation - human health 5.932 5.932 1.000
Resource use, fossils 1.97e+04 1.971e+04 1.000
Resource use, minerals and metals 0.3581 0.3578 1.001
Water use 186.2 172.5 1.080
Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like.
Also published by BAFU for this dataset: IPCC 2021 GWP100 1634 kg CO2 eq; Ecological Scarcity
2021 total 5.143e+06 UBP.

Sensitivity check

One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.

Exchange Base Low / high Range Δ GWP100 (%) Δ other categories (max %)
Steel, low-alloyed, at plant [RER] 146.9 kg ×0.721 / ×1.39 lognormal, GSD² 1.4 -5.4 / +7.4 9.6 (EF-particulate Matter)
Aluminium, primary, at plant [RER] 32.3 kg ×0.721 / ×1.39 lognormal, GSD² 1.4 -4.9 / +6.8 18.2 (Climate change-Land use and land use change)
Electronic component, unspecified, at plant [GLO] 1.5 kg ×0.721 / ×1.39 lognormal, GSD² 1.4 -4.6 / +6.4 30.9 (Resource use, minerals and metals)
Pentafluoroethane [air/Ground level / Urban (>1000 people/square mile)] 0.0525 kg ×0.647 / ×1.55 lognormal, GSD² 1.56 -4.2 / +6.6 6.7 (Climate change-Fossil)
Electricity, medium voltage, production ENTSO-E, at grid [ENTSO-E] 557.2 kWh ×0.652 / ×1.53 lognormal, GSD² 1.55 -3.2 / +5.0 20.1 (Ionising radiation, human health)
Copper, at regional storage [RER] 59.2 kg ×0.721 / ×1.39 lognormal, GSD² 1.4 -1.6 / +2.3 35.6 (Human toxicity, non-cancer_organics)
Natural gas, burned in industrial furnace 1MWth [CH] 1498 MJ ×0.826 / ×1.21 lognormal, GSD² 1.22 -1.2 / +1.5 2.0 (Resource use, fossils)
Difluoromethane [air/Ground level / Urban (>1000 people/square mile)] 0.0525 kg ×0.647 / ×1.55 lognormal, GSD² 1.56 -0.9 / +1.4 1.4 (Climate change-Fossil)
Tube insulation, elastomere, at plant [DE] 12.1 kg ×0.721 / ×1.39 lognormal, GSD² 1.4 -0.9 / +1.3 3.2 (Climate change-Land use and land use change)
Heat, biomethane, at industrial furnace 1MW [CH] 704.4 MJ ×0.652 / ×1.53 lognormal, GSD² 1.55 -0.6 / +0.9 39.2 (Climate change-Biogenic)
Disposal, plastics, mixture, 15.3% water, to municipal incineration [CH] 13.3 kg ×0.721 / ×1.39 lognormal, GSD² 1.4 -0.5 / +0.7 0.8 (Climate change-Fossil)
Trifluoromethane, at plant [GLO] 1.75 kg ×0.621 / ×1.61 lognormal, GSD² 1.62 -0.4 / +0.6 59.5 (Ozone depletion)
1,1-difluoroethane, HFC-152a, at plant [US] 1.75 kg ×0.621 / ×1.61 lognormal, GSD² 1.62 -0.2 / +0.3 0.4 (Water use)
Transport, freight, rail [RER] 154 tkm ×0.435 / ×2.3 lognormal, GSD² 2.34 -0.1 / +0.2 0.7 (Land use)
Transport, freight, lorry, 16t-32t gross weight, fleet average [CH] 12.8 tkm ×0.435 / ×2.3 lognormal, GSD² 2.34 -0.1 / +0.2 0.3 (Photochemical ozone formation - human health)

Uncertainty analysis

Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.

Comparison with other data

No other location of this dataset in the graph.

Conclusions and limitations

GWP100 1634 kg CO2 eq per p (95 % interval 1458–2308). Dominant contributors: Steel, low-alloyed, at plant 19 %; Aluminium, primary, at plant 18 %; Electronic component, unspecified, at plant 17 %; Pentafluoroethane 12 %; Electricity, medium voltage, production ENTSO-E, at grid 9 %; Natural gas, burned in industrial furnace 1MWth 7 %. Most sensitive: Steel, low-alloyed, at plant [RER] (-5.4 / +7.4 %); Aluminium, primary, at plant [RER] (-4.9 / +6.8 %); Electronic component, unspecified, at plant [GLO] (-4.6 / +6.4 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.

Final control

Item Status Detail
reference flow PASS production amount 1.0 p
closure: sum of direct contributions = dataset score (all 25 categories) PASS largest relative gap 4.7e-16
independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) PASS graph / published = 1; categories within ±5 %: 21/25
every technosphere input of the EcoSpold delivery is in the graph PASS all present (bafu_links_check.py)
uncertainty declared on the direct exchanges PASS 24/24 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values
Monte Carlo 95 % interval contains the deterministic score PASS 1634 in [1458, 2308]
time period declared PASS 2019-01/2020-12
geography is a known location code PASS RER
sources cited PASS 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them

References

  1. Kägi Thomas, Livia Waldburger, Cyril Kern, Gavin Roberts, Mischa Zschokke, Flora Conte, Lea Weber (2020) LCI of heating systems. Carbotech im Auftrag des BAFU. Carbotech AG. Zürich. CH. Type: Separate publication Source: Report First author: Kägi Thomas Other authors: Livia Waldburger, Cyril Kern, Gavin Roberts, Mischa Zschokke, Flora Conte, Lea Weber Year: 2020 Title of anthology: Carbotech im Au… — published source; as declared by BAFU (not found in OpenAlex/Crossref)
  2. Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — database; dataset citation
  3. International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva.
  4. Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. (tdc-doc method reference; title, version and year to verify against the user's copy)
  5. European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra.
  6. Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236

Annex — licence and terms of use

BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.


To suggest a correction or a dataset that does not exist yet, use Propose a dataset.