Dataset documentation and final control (tdc-doc, imported mode)
Open this dataset in OpenData
Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Control and wiring, central unit, at plant [RER], per 1 p. EF v3.1 climate change 23.81 kg CO2 eq (Monte Carlo 95 % interval 19.78–38.13). Main contributors: Electronics for control units 47 %; Polyvinylchloride, at regional storage 27 %; Copper, at regional storage 12 %; Extrusion, plastic pipes 3 %; Light fuel oil, burned in industrial furnace 1MW, non-modula… 3 %; Wire drawing, copper 3 %. Status: final control passed.
| Item | Value |
|---|---|
| Dataset name | Control and wiring, central unit, at plant |
| Dataset UUID / graph id | 8ddb0c1e-7574-3688-a48d-fb89fdecd806 / activity:control_and_wiring_central_unit_at_plant__rer |
| Reference product, unit | Control and wiring, central unit, at plant, 1 p |
| Location | RER — Data for production in Germany used. |
| Time period | 2003-01/2003-12 |
| Category | construction / ventilation\components |
| Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 |
| Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) |
| Background database | BAFU 2026 v1 (graph bafuquery-db) |
| LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) |
| Status | final control passed |
| Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 |
Production of a typical component used for a ventilation system in a multi family house. The house considered in the investigation includes 6 flats with 130 m2 floor area each and a ventilation rate of 120 m3/h.; UUID: 8ddb0c1e-7574-3688-a48d-fb89fdecd806
This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.
Reference flow: 1 p of Control and wiring, central unit, at plant (RER). All results are given per unit of the reference flow.
Materials used for the production. Estimation of electricity use for the different production steps. Energy use for heating of the production building. Transport of raw materials to the plant. Estimation for the Infrastructure of the Production site included.
Basic control unit for central ventilation equipment with 720 m3/h nominal air flow. Electrical wiring for connection of unit and grid connection. Weight of control unit 0.6 kg, weight of wiring 4.2 kg. Electrical wiring for connection of unit
Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).
EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.
Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).
| Exchange | Type | Location / compartment | Amount | Unit | Uncertainty | Pedigree | GWP share (%) | Notes | |
|---|---|---|---|---|---|---|---|---|---|
| Electronics for control units | technosphere | RER | 0.6 | kg | lognormal, GSD² 1.34 | (3,4,1,1,3,5) | 46.6 | █████████ | |
| Polyvinylchloride, at regional storage | technosphere | RER | 2.73 | kg | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 27.0 | █████ | |
| Copper, at regional storage | technosphere | RER | 1.76 | kg | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 11.9 | ██ | |
| Extrusion, plastic pipes | technosphere | RER | 2.73 | kg | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 2.9 | █ | |
| Light fuel oil, burned in industrial furnace 1MW, non-modulating | technosphere | RER | 6.96 | MJ | lognormal, GSD² 1.38 | — | 2.8 | █ | |
| Wire drawing, copper | technosphere | RER | 1.76 | kg | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 2.8 | █ | |
| Natural gas, burned in industrial furnace 1MWth | technosphere | CH | 6.96 | MJ | lognormal, GSD² 1.38 | (4,5,1,1,1,5) | 2.2 | · | |
| Plastics processing factory | technosphere | RER | 3.5600e-09 | p | lognormal, GSD² 3.18 | (4,5,1,1,3,5) | 1.6 | · | |
| Disposal, polyvinylchloride, 0.2% water, to municipal incineration | technosphere | CH | 0.13 | kg | lognormal, GSD² 1.32 | (4,4,1,1,1,5) | 1.1 | · | |
| Electricity, medium voltage, production ENTSO-E, at grid | technosphere | ENTSO-E | 0.528 | kWh | lognormal, GSD² 1.69 | (3,5,5,1,3,5) | 0.6 | · | |
| Transport, freight, lorry, fleet average | technosphere | RER | 0.51 | tkm | lognormal, GSD² 2.09 | — | 0.4 | · | |
| Transport, freight, rail | technosphere | RER | 1.02 | tkm | lognormal, GSD² 2.09 | — | 0.1 | · | |
| Waste Heat | elementary | air/Ground level / Urban (>1000 people/s… | 1.9 | MJ | lognormal, GSD² 1.69 | (3,5,5,1,3,5) | 0.0 | · |
10 of 13 direct exchanges carry a declared pedigree, 13 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 3.1 · completeness 4.4 · temporal 1.8 · geographical 1.0 · technological 1.8 · sample size 5.0.
| Field | As declared by the publisher |
|---|---|
| Data generator / entry / validation | data generator: Alex Primas (HSLU); data entry: Alex Primas (HSLU); validation (proof reading): Rolf Frischknecht (TREEZE) |
| extrapolations | none |
| sampling procedure | Questionnaire, technical information of producer and estimations. For control electronic proxy process used. |
| production volume | na |
| uncertainty adjustments | none |
| validation details | Proof reading validation: passed; Other validation: none; |
| time period comment | Materials investigated in 2003 |
None recorded.
Per 1 p. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.
| Impact category | Indicator | Unit | Result | 2.5 % | 97.5 % | GSD² |
|---|---|---|---|---|---|---|
| Acidification | Accumulated Exceedance (AE) | mol H+ eq | 0.3898 | 0.3174 | 0.5591 | 1.34 |
| Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | 0.1016 | 0.06374 | 0.2449 | 1.99 |
| Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | 23.7 | 19.7 | 37.99 | 1.41 |
| Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | 0.008009 | 0.006028 | 0.01555 | 1.6 |
| Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | 23.81 | 19.78 | 38.13 | 1.41 |
| EF-particulate Matter | Impact on human health | disease incidence | 1.359e-06 | 1.235e-06 | 2.279e-06 | 1.39 |
| Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | 251.1 | 221.8 | 581.3 | 1.68 |
| Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | 3.532 | 3.031 | 6.915 | 1.59 |
| Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | 254.6 | 225.8 | 585.8 | 1.67 |
| Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | 0.03847 | 0.03019 | 0.07185 | 1.6 |
| Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | 0.1464 | 0.08614 | 0.9699 | 3.58 |
| Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | 0.422 | 0.3215 | 0.6796 | 1.47 |
| Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | 4.796e-08 | 4.183e-08 | 1.300e-07 | 1.85 |
| Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | 8.356e-09 | 6.966e-09 | 1.933e-08 | 1.73 |
| Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | 5.632e-08 | 4.989e-08 | 1.462e-07 | 1.76 |
| Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | 4.531e-06 | 3.622e-06 | 1.284e-05 | 1.87 |
| Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | 3.307e-07 | 2.104e-07 | 6.114e-07 | 1.72 |
| Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | 4.862e-06 | 3.955e-06 | 1.316e-05 | 1.82 |
| Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | 4.819 | 1.941 | 30.47 | 4.1 |
| Land use | Soil quality index | pt (soil quality index) | 224 | 179.4 | 474.8 | 1.65 |
| Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | 3.580e-06 | 2.339e-06 | 7.430e-06 | 1.82 |
| Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | 0.1308 | 0.1089 | 0.204 | 1.38 |
| Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | 375.9 | 317.4 | 627.7 | 1.42 |
| Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | 0.008559 | 0.005203 | 0.01591 | 1.77 |
| Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | 5.217 | -9697 | 4842 | — |
Climate change 23.81 kg CO2 eq per p. Main contributors: Electronics for control units 47 %; Polyvinylchloride, at regional storage 27 %; Copper, at regional storage 12 %; Extrusion, plastic pipes 3 %; Light fuel oil, burned in industrial furnace 1MW, non-modula… 3 %; Wire drawing, copper 3 %.
Direct exchanges dominating climate change: Electronics for control units 47 %; Polyvinylchloride, at regional storage 27 %; Copper, at regional storage 12 %; Extrusion, plastic pipes 3 %; Light fuel oil, burned in industrial furnace 1MW, non-modula… 3 %; Wire drawing, copper 3 %. Most sensitive exchanges (Section 6.3): Electronics for control units [RER] (-11.6 / +15.5 %); Polyvinylchloride, at regional storage [RER] (-5.1 / +6.3 %); Copper, at regional storage [RER] (-2.4 / +3.0 %).
Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026):
| Category | Graph | Published | Graph / published |
|---|---|---|---|
| Acidification | 0.3898 | 0.4193 | 0.930 |
| Climate change-Biogenic | 0.1016 | 0.1016 | 1.000 |
| Climate change-Fossil | 23.7 | 23.7 | 1.000 |
| Climate change-Land use and land use change | 0.008009 | 0.008009 | 1.000 |
| Climate change | 23.81 | 23.81 | 1.000 |
| EF-particulate Matter | 1.359e-06 | 1.359e-06 | 1.000 |
| Ecotoxicity, freshwater_inorganics | 251.1 | 257.3 | 0.976 |
| Ecotoxicity, freshwater_organics | 3.532 | 3.293 | 1.073 |
| Ecotoxicity, freshwater | 254.6 | 258.5 | 0.985 |
| Eutrophication marine | 0.03847 | 0.03847 | 1.000 |
| Eutrophication, freshwater | 0.1464 | 0.1464 | 1.000 |
| Eutrophication, terrestrial | 0.422 | 0.432 | 0.977 |
| Human toxicity, cancer_inorganics | 4.796e-08 | 4.778e-08 | 1.004 |
| Human toxicity, cancer_organics | 8.356e-09 | 8.356e-09 | 1.000 |
| Human toxicity, cancer | 5.632e-08 | 5.613e-08 | 1.003 |
| Human toxicity, non-cancer_inorganics | 4.531e-06 | 4.518e-06 | 1.003 |
| Human toxicity, non-cancer_organics | 3.307e-07 | 3.306e-07 | 1.000 |
| Human toxicity, non-cancer | 4.862e-06 | 4.848e-06 | 1.003 |
| Ionising radiation, human health | 4.819 | 4.819 | 1.000 |
| Land use | 224 | 180.8 | 1.239 |
| Ozone depletion | 3.580e-06 | 3.580e-06 | 1.000 |
| Photochemical ozone formation - human health | 0.1308 | 0.1308 | 1.000 |
| Resource use, fossils | 375.9 | 376 | 1.000 |
| Resource use, minerals and metals | 0.008559 | 0.008511 | 1.006 |
| Water use | 5.217 | 5.531 | 0.943 |
| Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | |||
| Also published by BAFU for this dataset: IPCC 2021 GWP100 23.8 kg CO2 eq; Ecological Scarcity | |||
| 2021 total 1.100e+05 UBP. |
One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.
| Exchange | Base | Low / high | Range | Δ GWP100 (%) | Δ other categories (max %) |
|---|---|---|---|---|---|
| Electronics for control units [RER] | 0.6 kg | ×0.751 / ×1.33 | lognormal, GSD² 1.34 | -11.6 / +15.5 | 24.9 (Resource use, minerals and metals) |
| Polyvinylchloride, at regional storage [RER] | 2.73 kg | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -5.1 / +6.3 | 16.4 (Ozone depletion) |
| Copper, at regional storage [RER] | 1.76 kg | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -2.4 / +3.0 | 21.4 (Human toxicity, non-cancer_organics) |
| Plastics processing factory [RER] | 3.560e-09 p | ×0.322 / ×3.11 | lognormal, GSD² 3.18 | -1.1 / +3.4 | 22.9 (Land use) |
| Light fuel oil, burned in industrial furnace 1MW, non-modulating [RER] | 6.96 MJ | ×0.729 / ×1.37 | lognormal, GSD² 1.38 | -0.8 / +1.0 | 1.0 (Climate change-Fossil) |
| Natural gas, burned in industrial furnace 1MWth [CH] | 6.96 MJ | ×0.729 / ×1.37 | lognormal, GSD² 1.38 | -0.6 / +0.8 | 0.8 (Resource use, fossils) |
| Wire drawing, copper [RER] | 1.76 kg | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -0.6 / +0.7 | 1.8 (Ionising radiation, human health) |
| Extrusion, plastic pipes [RER] | 2.73 kg | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.6 / +0.7 | 2.5 (Ionising radiation, human health) |
| Electricity, medium voltage, production ENTSO-E, at grid [ENTSO-E] | 0.528 kWh | ×0.598 / ×1.67 | lognormal, GSD² 1.69 | -0.2 / +0.4 | 2.7 (Ionising radiation, human health) |
| Transport, freight, lorry, fleet average [RER] | 0.51 tkm | ×0.486 / ×2.06 | lognormal, GSD² 2.09 | -0.2 / +0.4 | 4.9 (Climate change-Land use and land use change) |
| Disposal, polyvinylchloride, 0.2% water, to municipal incineration [CH] | 0.13 kg | ×0.762 / ×1.31 | lognormal, GSD² 1.32 | -0.3 / +0.4 | 3.1 (Water use) |
| Transport, freight, rail [RER] | 1.02 tkm | ×0.486 / ×2.06 | lognormal, GSD² 2.09 | -0.0 / +0.1 | 0.4 (Ionising radiation, human health) |
Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.
No other location of this dataset in the graph.
GWP100 23.81 kg CO2 eq per p (95 % interval 19.78–38.13). Dominant contributors: Electronics for control units 47 %; Polyvinylchloride, at regional storage 27 %; Copper, at regional storage 12 %; Extrusion, plastic pipes 3 %; Light fuel oil, burned in industrial furnace 1MW, non-modula… 3 %; Wire drawing, copper 3 %. Most sensitive: Electronics for control units [RER] (-11.6 / +15.5 %); Polyvinylchloride, at regional storage [RER] (-5.1 / +6.3 %); Copper, at regional storage [RER] (-2.4 / +3.0 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.
| Item | Status | Detail |
|---|---|---|
| reference flow | PASS | production amount 1.0 p |
| closure: sum of direct contributions = dataset score (all 25 categories) | PASS | largest relative gap 2.8e-16 |
| independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) | PASS | graph / published = 1; categories within ±5 %: 21/25 |
| every technosphere input of the EcoSpold delivery is in the graph | PASS | all present (bafu_links_check.py) |
| uncertainty declared on the direct exchanges | PASS | 13/13 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values |
| Monte Carlo 95 % interval contains the deterministic score | PASS | 23.81 in [19.78, 38.13] |
| time period declared | PASS | 2003-01/2003-12 |
| geography is a known location code | PASS | RER |
| sources cited | PASS | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them |
BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.
To suggest a correction or a dataset that does not exist yet, use Propose a dataset.