Dataset documentation and final control (tdc-doc, imported mode)
Open this dataset in OpenData
Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Disposal, ventilation system, Schulhaus Albisriederplatz [CH], per 1 p. EF v3.1 climate change 5336 kg CO2 eq (Monte Carlo 95 % interval 4902–6216). Main contributors: Disposal, ventilation unit 13000 m3/h, w. cross plate heat e… 17 %; Disposal, EI 30 fire insulation, 50mm, 120kg/m3, reinforced … 14 %; Disposal, spiral-seam duct, steel, zinc coated, s= 0.6mm 13 %; Disposal, ventilation unit 13000 m3/h, w. circuit connected … 12 %; Disposal, spiral-seam duct, steel, zinc coated, s= 0.5mm 10 %; Disposal, thermal insulation, 30mm, 40kg/m3, reinforced alum… 7 %. Status: final control passed.
| Item | Value |
|---|---|
| Dataset name | Disposal, ventilation system, Schulhaus Albisriederplatz |
| Dataset UUID / graph id | 936b393d-86ea-48d2-946a-cd7d431f580c / activity:disposal_ventilation_system_schulhaus_albisriederplatz__ch |
| Reference product, unit | Disposal, ventilation system, Schulhaus Albisriederplatz, 1 p |
| Location | CH — Specific to the technology mix encountered in sorting plants in Switzerland. |
| Time period | 2014-01/2014-12 |
| Category | waste management / building demolition |
| Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 |
| Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) |
| Background database | BAFU 2026 v1 (graph bafuquery-db) |
| LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) |
| Status | final control passed |
| Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 |
Disposal of a ventilation system for a school with schoolrooms, canteen and multi-purpose hall. The inventory is based on a building with a total heated gross floor area of 5603 m2 and a total nominal air flow of 31620 m3/h, total weight of the components: 8393 kg/Unit, building with a specific air flow rate of 5.6 m3/h per m2 heated gross floor area. Data from call of bid including components for air handling units, ducts including insulation, air valves, roof-hoods, dampers, fire dampers, silencers. The data represent a ductwork mainly made of galvanized steel and includes air handling units mainly with heat recovery. System with central air handling units. Building without ground heat exchanger.; UUID: 936b393d-86ea-48d2-946a-cd7d431f580c
This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.
Reference flow: 1 p of Disposal, ventilation system, Schulhaus Albisriederplatz (CH). All results are given per unit of the reference flow.
Transport to dismantling facilities, machines for handling in sorting plant, electricity demand for sorting plant, final disposal of waste material. Cut-off to recycling for metals.
Disposal to a sorting plant assumed. Metal pieces, copper in cables and electronic devices are recycled, plastic parts are incinerated, inert wastes (e.g. rock wool) are landfilled.
Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).
EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.
Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).
| Exchange | Type | Location / compartment | Amount | Unit | Uncertainty | Pedigree | GWP share (%) | Notes | |
|---|---|---|---|---|---|---|---|---|---|
| Disposal, ventilation unit 13000 m3/h, w. cross plate heat excanger | technosphere | CH | 1 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 16.6 | ███ | |
| Disposal, EI 30 fire insulation, 50mm, 120kg/m3, reinforced alumium foil | technosphere | CH | 2940 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 13.7 | ███ | |
| Disposal, spiral-seam duct, steel, zinc coated, s= 0.6mm | technosphere | CH | 2043.9 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 12.8 | ███ | |
| Disposal, ventilation unit 13000 m3/h, w. circuit connected heat exchanger | technosphere | CH | 0.751 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 11.8 | ██ | |
| Disposal, spiral-seam duct, steel, zinc coated, s= 0.5mm | technosphere | CH | 1677 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 10.4 | ██ | |
| Disposal, thermal insulation, 30mm, 40kg/m3, reinforced alumium foil | technosphere | CH | 2332 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 7.1 | █ | |
| Disposal, ventilation unit 6700 m3/h, w. circuit connected heat exchanger | technosphere | CH | 0.646 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 6.0 | █ | |
| Disposal, ventilation duct, steel, zinc coated, s= 0.62mm | technosphere | CH | 1536.1 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 5.2 | █ | |
| Disposal, ventilation unit 1800 m3/h, w. cross plate heat excanger | technosphere | CH | 0.983 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 3.4 | █ | |
| Disposal, ventilation duct, steel, zinc coated, s= 0.75mm | technosphere | CH | 961.52 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 3.3 | █ | |
| Disposal, ventilation system, Schulhaus Albisriederplatz, various components | technosphere | CH | 1 | p | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 3.3 | █ | |
| Disposal, silencer for ventilator unit 13000 m3/h, modular | technosphere | CH | 3.502 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 1.6 | · | |
| Disposal, ventilation duct, steel, zinc coated, s= 0.87mm | technosphere | CH | 363.04 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 1.3 | · | |
| Disposal, flexible duct, aluminum/PET, DN of 125 | technosphere | CH | 191.25 | m | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 1.0 | · | |
| Disposal, ventilation duct, steel, zinc coated, s= 1.0mm | technosphere | CH | 209.12 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.8 | · | |
| Disposal, silencer for ventilator unit 6700 m3/h, modular, Device | technosphere | CH | 1.292 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 0.4 | · | |
| Disposal, silencer for ventilator unit 1800 m3/h, modular, Device | technosphere | CH | 1.966 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 0.4 | · | |
| Disposal, ventilation duct, steel, zinc coated, s= 1.25mm | technosphere | CH | 79.682 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.3 | · | |
| Disposal, spiral-seam duct, steel, zinc coated, s= 0.8mm | technosphere | CH | 46.496 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.3 | · | |
| Disposal, ventilation duct, stainless steel, s= 1.0mm | technosphere | CH | 80.935 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.3 | · | |
| Disposal, ventilation duct, stainless steel, s= 0.87mm | technosphere | CH | 16.556 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.1 | · | |
| Disposal, ventilation duct, steel, zinc coated, s= 1.5mm | technosphere | CH | 11.839 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.0 | · | |
| Disposal, ventilation system, Schulhaus Albisriederplatz, special components | technosphere | CH | 1 | p | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.0 | · |
23 of 23 direct exchanges carry a declared pedigree, 23 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 2.3 · completeness 4.0 · temporal 1.0 · geographical 1.0 · technological 1.0 · sample size 5.0.
| Field | As declared by the publisher |
|---|---|
| Data generator / entry / validation | data generator: Alex Primas (HSLU); data entry: Alex Primas (HSLU); validation (proof reading): Alex Primas (HSLU) |
| extrapolations | none |
| sampling procedure | Waste-specific calculation based on production input data |
| production volume | na |
| uncertainty adjustments | none |
| time period comment | Amount of material investigated in 2013. Disposal technology mix as used in late 1990ies |
None recorded.
Per 1 p. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.
| Impact category | Indicator | Unit | Result | 2.5 % | 97.5 % | GSD² |
|---|---|---|---|---|---|---|
| Acidification | Accumulated Exceedance (AE) | mol H+ eq | 1.673 | 1.529 | 2.825 | 1.38 |
| Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | 1.17 | 0.9249 | 2.259 | 1.57 |
| Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | 5335 | 4900 | 6214 | 1.13 |
| Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | 0.2187 | 0.188 | 0.3333 | 1.34 |
| Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | 5336 | 4902 | 6216 | 1.13 |
| EF-particulate Matter | Impact on human health | disease incidence | 1.926e-04 | 1.166e-04 | 4.131e-04 | 1.89 |
| Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | 1.733e+04 | 1.394e+04 | 2.81e+04 | 1.43 |
| Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | 101 | 87.39 | 182.6 | 1.48 |
| Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | 1.743e+04 | 1.406e+04 | 2.826e+04 | 1.43 |
| Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | 1.762 | 1.475 | 3.418 | 1.52 |
| Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | 1.544 | 0.192 | 47.35 | 17.9 |
| Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | 13.23 | 10.93 | 26.94 | 1.57 |
| Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | 2.122e-07 | 2.244e-07 | 7.959e-07 | 1.87 |
| Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | 1.558e-07 | 1.282e-07 | 2.409e-07 | 1.4 |
| Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | 3.680e-07 | 3.828e-07 | 9.789e-07 | 1.59 |
| Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | 1.313e-05 | 1.343e-05 | 4.401e-05 | 1.82 |
| Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | 1.359e-06 | 9.999e-07 | 2.247e-06 | 1.5 |
| Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | 1.449e-05 | 1.486e-05 | 4.548e-05 | 1.76 |
| Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | 194.7 | 74.28 | 1115 | 4.16 |
| Land use | Soil quality index | pt (soil quality index) | 9352 | -3166 | 2.557e+04 | — |
| Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | 2.308e-05 | 2.030e-05 | 3.482e-05 | 1.3 |
| Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | 5.341 | 4.525 | 9.825 | 1.47 |
| Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | 1.069e+04 | 9714 | 1.563e+04 | 1.27 |
| Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | 0.001344 | 0.001145 | 0.002639 | 1.53 |
| Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | 570.2 | -8.531e+04 | 4.419e+04 | — |
Climate change 5336 kg CO2 eq per p. Main contributors: Disposal, ventilation unit 13000 m3/h, w. cross plate heat e… 17 %; Disposal, EI 30 fire insulation, 50mm, 120kg/m3, reinforced … 14 %; Disposal, spiral-seam duct, steel, zinc coated, s= 0.6mm 13 %; Disposal, ventilation unit 13000 m3/h, w. circuit connected … 12 %; Disposal, spiral-seam duct, steel, zinc coated, s= 0.5mm 10 %; Disposal, thermal insulation, 30mm, 40kg/m3, reinforced alum… 7 %.
Direct exchanges dominating climate change: Disposal, ventilation unit 13000 m3/h, w. cross plate heat e… 17 %; Disposal, EI 30 fire insulation, 50mm, 120kg/m3, reinforced … 14 %; Disposal, spiral-seam duct, steel, zinc coated, s= 0.6mm 13 %; Disposal, ventilation unit 13000 m3/h, w. circuit connected … 12 %; Disposal, spiral-seam duct, steel, zinc coated, s= 0.5mm 10 %; Disposal, thermal insulation, 30mm, 40kg/m3, reinforced alum… 7 %. Most sensitive exchanges (Section 6.3): Disposal, ventilation unit 13000 m3/h, w. cross plate heat excanger [CH] (-3.4 / +4.2 %); Disposal, EI 30 fire insulation, 50mm, 120kg/m3, reinforced alumium foil [CH] (-2.6 / +3.2 %); Disposal, spiral-seam duct, steel, zinc coated, s= 0.6mm [CH] (-2.4 / +3.0 %).
Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026):
| Category | Graph | Published | Graph / published |
|---|---|---|---|
| Acidification | 1.673 | 3.521 | 0.475 |
| Climate change-Biogenic | 1.17 | 1.17 | 1.000 |
| Climate change-Fossil | 5335 | 5335 | 1.000 |
| Climate change-Land use and land use change | 0.2187 | 0.2187 | 1.000 |
| Climate change | 5336 | 5336 | 1.000 |
| EF-particulate Matter | 1.926e-04 | 1.926e-04 | 1.000 |
| Ecotoxicity, freshwater_inorganics | 1.733e+04 | 1.8e+04 | 0.963 |
| Ecotoxicity, freshwater_organics | 101 | 100.7 | 1.003 |
| Ecotoxicity, freshwater | 1.743e+04 | 1.81e+04 | 0.963 |
| Eutrophication marine | 1.762 | 1.762 | 1.000 |
| Eutrophication, freshwater | 1.544 | 1.544 | 1.000 |
| Eutrophication, terrestrial | 13.23 | 16.73 | 0.791 |
| Human toxicity, cancer_inorganics | 2.122e-07 | 2.113e-07 | 1.004 |
| Human toxicity, cancer_organics | 1.558e-07 | 1.558e-07 | 1.000 |
| Human toxicity, cancer | 3.680e-07 | 3.671e-07 | 1.002 |
| Human toxicity, non-cancer_inorganics | 1.313e-05 | 1.305e-05 | 1.006 |
| Human toxicity, non-cancer_organics | 1.359e-06 | 1.359e-06 | 1.000 |
| Human toxicity, non-cancer | 1.449e-05 | 1.441e-05 | 1.006 |
| Ionising radiation, human health | 194.7 | 194.7 | 1.000 |
| Land use | 9352 | 5295 | 1.766 |
| Ozone depletion | 2.308e-05 | 2.308e-05 | 1.000 |
| Photochemical ozone formation - human health | 5.341 | 5.341 | 1.000 |
| Resource use, fossils | 1.069e+04 | 1.069e+04 | 1.000 |
| Resource use, minerals and metals | 0.001344 | 0.00118 | 1.139 |
| Water use | 570.2 | 577.3 | 0.988 |
| Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | |||
| Also published by BAFU for this dataset: IPCC 2021 GWP100 5336 kg CO2 eq; Ecological Scarcity | |||
| 2021 total 1.279e+07 UBP. |
One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.
| Exchange | Base | Low / high | Range | Δ GWP100 (%) | Δ other categories (max %) |
|---|---|---|---|---|---|
| Disposal, ventilation unit 13000 m3/h, w. cross plate heat excanger [CH] | 1 p | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -3.4 / +4.2 | 8.2 (Water use) |
| Disposal, EI 30 fire insulation, 50mm, 120kg/m3, reinforced alumium foil [CH] | 2940 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -2.6 / +3.2 | 19.3 (Eutrophication, freshwater) |
| Disposal, spiral-seam duct, steel, zinc coated, s= 0.6mm [CH] | 2044 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -2.4 / +3.0 | 3.0 (Climate change-Fossil) |
| Disposal, ventilation unit 13000 m3/h, w. circuit connected heat exchanger [CH] | 0.751 p | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -2.4 / +3.0 | 6.0 (Water use) |
| Disposal, spiral-seam duct, steel, zinc coated, s= 0.5mm [CH] | 1677 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -2.0 / +2.4 | 2.4 (Climate change-Fossil) |
| Disposal, thermal insulation, 30mm, 40kg/m3, reinforced alumium foil [CH] | 2332 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -1.3 / +1.7 | 3.1 (Eutrophication, freshwater) |
| Disposal, ventilation unit 6700 m3/h, w. circuit connected heat exchanger [CH] | 0.646 p | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -1.2 / +1.5 | 2.7 (Water use) |
| Disposal, ventilation duct, steel, zinc coated, s= 0.62mm [CH] | 1536 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -1.0 / +1.2 | 2.3 (Ionising radiation, human health) |
| Disposal, ventilation unit 1800 m3/h, w. cross plate heat excanger [CH] | 0.983 p | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -0.7 / +0.9 | 1.3 (Human toxicity, cancer_inorganics) |
| Disposal, ventilation duct, steel, zinc coated, s= 0.75mm [CH] | 961.5 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.6 / +0.8 | 1.7 (Ionising radiation, human health) |
| Disposal, ventilation system, Schulhaus Albisriederplatz, various components [CH] | 1 p | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.6 / +0.8 | 1.2 (Ionising radiation, human health) |
| Disposal, silencer for ventilator unit 13000 m3/h, modular [CH] | 3.502 p | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -0.3 / +0.4 | 0.9 (Eutrophication marine) |
| Disposal, ventilation duct, steel, zinc coated, s= 0.87mm [CH] | 363 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.2 / +0.3 | 0.8 (Ionising radiation, human health) |
| Disposal, flexible duct, aluminum/PET, DN of 125 [CH] | 191.2 m | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.2 / +0.2 | 0.3 (Human toxicity, non-cancer_inorganics) |
| Disposal, ventilation duct, steel, zinc coated, s= 1.0mm [CH] | 209.1 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.1 / +0.2 | 0.5 (Ionising radiation, human health) |
Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.
No other location of this dataset in the graph.
GWP100 5336 kg CO2 eq per p (95 % interval 4902–6216). Dominant contributors: Disposal, ventilation unit 13000 m3/h, w. cross plate heat e… 17 %; Disposal, EI 30 fire insulation, 50mm, 120kg/m3, reinforced … 14 %; Disposal, spiral-seam duct, steel, zinc coated, s= 0.6mm 13 %; Disposal, ventilation unit 13000 m3/h, w. circuit connected … 12 %; Disposal, spiral-seam duct, steel, zinc coated, s= 0.5mm 10 %; Disposal, thermal insulation, 30mm, 40kg/m3, reinforced alum… 7 %. Most sensitive: Disposal, ventilation unit 13000 m3/h, w. cross plate heat excanger [CH] (-3.4 / +4.2 %); Disposal, EI 30 fire insulation, 50mm, 120kg/m3, reinforced alumium foil [CH] (-2.6 / +3.2 %); Disposal, spiral-seam duct, steel, zinc coated, s= 0.6mm [CH] (-2.4 / +3.0 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.
| Item | Status | Detail |
|---|---|---|
| reference flow | PASS | production amount 1.0 p |
| closure: sum of direct contributions = dataset score (all 25 categories) | PASS | largest relative gap 3.4e-16 |
| independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) | PASS | graph / published = 1; categories within ±5 %: 21/25 |
| every technosphere input of the EcoSpold delivery is in the graph | PASS | all present (bafu_links_check.py) |
| uncertainty declared on the direct exchanges | PASS | 23/23 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values |
| Monte Carlo 95 % interval contains the deterministic score | PASS | 5336 in [4902, 6216] |
| time period declared | PASS | 2014-01/2014-12 |
| geography is a known location code | PASS | CH |
| sources cited | PASS | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them |
BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.