Table of Contents

Nitrogen, liquid, at plant — RER

Dataset documentation and final control (tdc-doc, imported mode)
Open this dataset in OpenData

Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Nitrogen, liquid, at plant [RER], per 1 kg. EF v3.1 climate change 0.2237 kg CO2 eq (Monte Carlo 95 % interval 0.1913–0.2965). Main contributors: Electricity, medium voltage, production ENTSO-E, at grid 100 %. Status: final control passed.
Item Value
Dataset name Nitrogen, liquid, at plant
Dataset UUID / graph id a2bbcfbc-5d63-3e86-9bab-8d4c2b6fdbc0 / activity:nitrogen_liquid_at_plant__rer
Reference product, unit Nitrogen, liquid, at plant, 1 kg
Location RER — Data from several producer in europe. Data from U.S. and Russian plant producer.
Time period 2000-01/2000-12
Category chemicals / gases
Source database BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1
Publisher Swiss Federal Office for the Environment (FOEN/BAFU)
Background database BAFU 2026 v1 (graph bafuquery-db)
LCIA method EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix)
Status final control passed
Documented by tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17

Introduction

The liquefaction process of air represent an average cryogenic air separation process. As products only liquid nitrogen, liquid oxygen and liquid crude argon were considered. No gaseous product considered. The allocation factors were calculated from the heat of vaporisation and the specific heat capacity multiplied with the temperature difference from 20°C to the boiling point. Multi output process. The allocated outputs are liquid nitrogen, liquid oxygen and liquid crude argon.; Formula: N2, O2, Ar; UUID: a2bbcfbc-5d63-3e86-9bab-8d4c2b6fdbc0

This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.

Goal and scope

Function, functional unit and reference flow

Reference flow: 1 kg of Nitrogen, liquid, at plant (RER). All results are given per unit of the reference flow.

System boundary

Electricity for process, cooling water and waste heat. Infrastructure for air separation plant.

Technology

Cryogenic air separation. Average energy demand refers to large separation plant under operating conditions or a small plant under optimal conditions.

Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).

LCIA method

EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.

Life cycle inventory

Inventory table

Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).

Exchange Type Location / compartment Amount Unit Uncertainty Pedigree GWP share (%) Notes
Electricity, medium voltage, production ENTSO-E, at grid technosphere ENTSO-E 0.81483 kWh lognormal, GSD² 1.19 (3,4,1,1,1,4) 99.8 ████████████████████
Air separation plant technosphere RER 6.4168e-10 p lognormal, GSD² 3.36 (5,5,1,3,3,5) 0.2 ·
Transport, freight, rail technosphere RER 0.0027501 tkm lognormal, GSD² 1.55 (3,4,1,1,4,4) 0.0 ·
Cooling water elementary natural resource 0.0027501 m3 lognormal, GSD² 1.55 (3,4,1,1,4,4) 0.0 ·
Waste Heat elementary air/Medium stack, <150 meters / Rural (<… 2.9334 MJ lognormal, GSD² 1.19 (3,4,1,1,1,4) 0.0 ·
Water elementary water/Unknown 0.0026126 m3 lognormal, GSD² 2.52 — 0.0 ·

Data quality

5 of 6 direct exchanges carry a declared pedigree, 6 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 3.4 · completeness 4.2 · temporal 1.0 · geographical 1.4 · technological 2.6 · sample size 4.2.

Field As declared by the publisher
Data generator / entry / validation data generator: Alex Primas (HSLU); data entry: Alex Primas (HSLU); validation (proof reading): Roland Hischier (EMPA)
extrapolations Energy data of good representativity. Cooling water demand and Infrastructure extrapolated from technology of lower representativity.
sampling procedure Data on energy demand and water ressources based on several data sources of different plant size. Infrastructure demand estimated from data of small plants.
production volume na
uncertainty adjustments none
validation details Proof reading validation: Passed.; Other validation: none;
time period comment undefined

Data gaps, proxies and assumptions

None recorded.

Life cycle impact assessment (EF v3.1)

Per 1 kg. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.

Impact category Indicator Unit Result 2.5 % 97.5 % GSD²
Acidification Accumulated Exceedance (AE) mol H+ eq 3.355e-04 2.993e-04 4.807e-04 1.27
Climate change-Biogenic Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.003798 0.002174 0.009169 2.07
Climate change-Fossil Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.2198 0.1874 0.2911 1.26
Climate change-Land use and land use change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 1.219e-04 9.875e-05 1.788e-04 1.35
Climate change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.2237 0.1913 0.2965 1.26
EF-particulate Matter Impact on human health disease incidence 4.287e-09 3.748e-09 6.834e-09 1.35
Ecotoxicity, freshwater_inorganics Comparative Toxic Unit for ecosystems (CTUe) CTUe 0.624 0.5111 1.422 1.69
Ecotoxicity, freshwater_organics Comparative Toxic Unit for ecosystems (CTUe) CTUe 0.008091 0.006647 0.02311 1.9
Ecotoxicity, freshwater Comparative Toxic Unit for ecosystems (CTUe) CTUe 0.6321 0.5193 1.433 1.68
Eutrophication marine Fraction of nutrients reaching marine end compartment (N) kg N eq 1.445e-04 1.269e-04 2.054e-04 1.27
Eutrophication, freshwater Fraction of nutrients reaching freshwater end compartment (P) kg P eq 1.988e-04 8.299e-05 7.261e-04 2.94
Eutrophication, terrestrial Accumulated Exceedance (AE) mol N eq 8.510e-04 7.680e-04 0.001286 1.3
Human toxicity, cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 3.184e-11 3.342e-11 8.464e-11 1.58
Human toxicity, cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 1.666e-10 1.196e-10 2.555e-10 1.47
Human toxicity, cancer Comparative Toxic Unit for human (CTUh) CTUh 1.985e-10 1.630e-10 3.207e-10 1.4
Human toxicity, non-cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 1.599e-09 1.665e-09 4.303e-09 1.61
Human toxicity, non-cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 6.196e-11 5.495e-11 1.176e-10 1.46
Human toxicity, non-cancer Comparative Toxic Unit for human (CTUh) CTUh 1.661e-09 1.724e-09 4.389e-09 1.6
Ionising radiation, human health Human exposure efficiency relative to U235 kBq U235 eq 0.2953 0.09594 1.86 4.35
Land use Soil quality index pt (soil quality index) 1.974 1.349 3.379 1.6
Ozone depletion Ozone Depletion Potential (ODP) kg CFC-11 eq 5.492e-09 4.232e-09 1.123e-08 1.63
Photochemical ozone formation - human health Tropospheric ozone concentration increase kg NMVOC eq 4.067e-04 3.624e-04 7.309e-04 1.41
Resource use, fossils Abiotic resource depletion fossil fuels (ADP-fossil) MJ 5.118 4.362 7.768 1.35
Resource use, minerals and metals Abiotic resource depletion (ADP ultimate reserve) kg Sb eq 3.146e-07 2.716e-07 6.666e-07 1.59
Water use User deprivation potential (deprivation-weighted water consumption) m3 world eq deprived 0.04504 -167.5 84.46 —

Climate change 0.2237 kg CO2 eq per kg. Main contributors: Electricity, medium voltage, production ENTSO-E, at grid 100 %.

Interpretation

Significant issues

Direct exchanges dominating climate change: Electricity, medium voltage, production ENTSO-E, at grid 100 %. Most sensitive exchanges (Section 6.3): Electricity, medium voltage, production ENTSO-E, at grid [ENTSO-E] (-15.6 / +18.6 %); Air separation plant [RER] (-0.1 / +0.4 %); Transport, freight, rail [RER] (-0.0 / +0.0 %).

Independent recalculation

Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026):

Category Graph Published Graph / published
Acidification 3.355e-04 7.501e-04 0.447
Climate change-Biogenic 0.003798 0.003798 1.000
Climate change-Fossil 0.2198 0.2198 1.000
Climate change-Land use and land use change 1.219e-04 1.219e-04 1.000
Climate change 0.2237 0.2237 1.000
EF-particulate Matter 4.287e-09 4.287e-09 1.000
Ecotoxicity, freshwater_inorganics 0.624 0.6473 0.964
Ecotoxicity, freshwater_organics 0.008091 0.007959 1.017
Ecotoxicity, freshwater 0.6321 0.6551 0.965
Eutrophication marine 1.445e-04 1.445e-04 1.000
Eutrophication, freshwater 1.988e-04 1.988e-04 1.000
Eutrophication, terrestrial 8.510e-04 0.001148 0.741
Human toxicity, cancer_inorganics 3.184e-11 2.680e-11 1.188
Human toxicity, cancer_organics 1.666e-10 1.666e-10 1.000
Human toxicity, cancer 1.985e-10 1.934e-10 1.026
Human toxicity, non-cancer_inorganics 1.599e-09 1.447e-09 1.105
Human toxicity, non-cancer_organics 6.196e-11 6.195e-11 1.000
Human toxicity, non-cancer 1.661e-09 1.509e-09 1.101
Ionising radiation, human health 0.2953 0.2953 1.000
Land use 1.974 1.635 1.207
Ozone depletion 5.492e-09 5.492e-09 1.000
Photochemical ozone formation - human health 4.067e-04 4.067e-04 1.000
Resource use, fossils 5.118 5.126 0.999
Resource use, minerals and metals 3.146e-07 3.052e-07 1.031
Water use 0.04504 0.05369 0.839
Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like.
Also published by BAFU for this dataset: IPCC 2021 GWP100 0.2236 kg CO2 eq; Ecological Scarcity
2021 total 468.7 UBP.

Sensitivity check

One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.

Exchange Base Low / high Range Δ GWP100 (%) Δ other categories (max %)
Electricity, medium voltage, production ENTSO-E, at grid [ENTSO-E] 0.8148 kWh ×0.843 / ×1.19 lognormal, GSD² 1.19 -15.6 / +18.6 18.6 (Climate change-Biogenic)
Air separation plant [RER] 6.417e-10 p ×0.305 / ×3.28 lognormal, GSD² 3.36 -0.1 / +0.4 22.9 (Resource use, minerals and metals)
Transport, freight, rail [RER] 0.00275 tkm ×0.651 / ×1.54 lognormal, GSD² 1.55 -0.0 / +0.0 0.1 (Human toxicity, non-cancer_organics)
Cooling water [natural resource] 0.00275 m3 ×0.651 / ×1.54 lognormal, GSD² 1.55 -0.0 / +0.0 140.7 (Water use)
Water [water/Unknown] 0.002613 m3 ×0.404 / ×2.47 lognormal, GSD² 2.52 -0.0 / +0.0 367.1 (Water use)

Uncertainty analysis

Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.

Comparison with other data

No other location of this dataset in the graph.

Conclusions and limitations

GWP100 0.2237 kg CO2 eq per kg (95 % interval 0.1913–0.2965). Dominant contributors: Electricity, medium voltage, production ENTSO-E, at grid 100 %. Most sensitive: Electricity, medium voltage, production ENTSO-E, at grid [ENTSO-E] (-15.6 / +18.6 %); Air separation plant [RER] (-0.1 / +0.4 %); Transport, freight, rail [RER] (-0.0 / +0.0 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.

Final control

Item Status Detail
reference flow PASS production amount 1.0 kg
closure: sum of direct contributions = dataset score (all 25 categories) PASS largest relative gap 3.1e-16
independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) PASS graph / published = 1; categories within ±5 %: 18/25
every technosphere input of the EcoSpold delivery is in the graph PASS all present (bafu_links_check.py)
uncertainty declared on the direct exchanges PASS 6/6 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values
Monte Carlo 95 % interval contains the deterministic score PASS 0.2237 in [0.1913, 0.2965]
time period declared PASS 2000-01/2000-12
geography is a known location code PASS RER
sources cited PASS 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them

References

  1. Althaus H.-J., Chudacoff M., Hischier R., Jungbluth N., Osses M., Primas A. (2007) Life Cycle Inventories of Chemicals. Final report ecoinvent data v2.0. Volume: 8. Swiss Centre for LCI, Empa - TSL. Dübendorf, CH. Type: Measurement on site Source: CD-ROM First author: Althaus H.-J. Other authors: Chudacoff M., Hischier R., Jungbluth N., Osses M., Primas A. Year: 2007 Title of anthology: Final repo… — published source; as declared by BAFU (not found in OpenAlex/Crossref)
  2. Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — database; dataset citation
  3. International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva.
  4. Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. (tdc-doc method reference; title, version and year to verify against the user's copy)
  5. European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra.
  6. Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236

Annex — licence and terms of use

BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.


To suggest a correction or a dataset that does not exist yet, use Propose a dataset.