Table of Contents

EKG I, electrical system, office building, construction — CH

Dataset documentation and final control (tdc-doc, imported mode)
Open this dataset in OpenData

Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset EKG I, electrical system, office building, construction [CH], per 1 m2. EF v3.1 climate change 20.63 kg CO2 eq (Monte Carlo 95 % interval 19.91–28.96). Main contributors: Printed wiring board mounting plant 16 %; Steel, low-alloyed, at plant 13 %; Copper, at regional storage 12 %; Polyethylene, HDPE, granulate, at plant 9 %; Connector, computer, peripherical type, at plant 8 %; Aluminium, production mix, at plant 7 %. Status: final control: 0 failed, 1 warning(s) (Section 7).
Item Value
Dataset name EKG I, electrical system, office building, construction
Dataset UUID / graph id ac4fb5f0-36d8-3a44-b51b-9ad8355c9796 / activity:ekg_i_electrical_system_office_building_construction__ch
Reference product, unit EKG I, electrical system, office building, construction, 1 m2
Location CH — Data for Zurich, Switzerland
Time period 2013-01/2013-12
Category construction processes / buildings
Source database BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1
Publisher Swiss Federal Office for the Environment (FOEN/BAFU)
Background database BAFU 2026 v1 (graph bafuquery-db)
LCIA method EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix)
Status final control: 0 failed, 1 warning(s) (Section 7)
Documented by tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17

Introduction

Elektroanlagen, tiefer Installationsgrad; UUID: ac4fb5f0-36d8-3a44-b51b-9ad8355c9796

This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.

Goal and scope

Function, functional unit and reference flow

Reference flow: 1 m2 of EKG I, electrical system, office building, construction (CH). All results are given per unit of the reference flow.

System boundary

This data set includes the material use for the manufacturing of the electronic installations in an office building according to Klingler and Kasser, 2011. The source states that 95 % of the mass volume is accounted for, which covers about 100 individual components. 1 office building was taken into account. The energy reference area is 2062 m2 for the basic construction and 1405 m2 for the tenant equipment (Mieterausbau). Basic and tenant“s equipment were taken into account both relative to each energy reference areas. The neon tubes and lamp fitting, as well as the control gear (EVG and VVG) were modelled with an energy saving light bulb. The electrical system has a life-span of 30 years. Transport is included.

Technology

Average technology

Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).

LCIA method

EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.

Life cycle inventory

Inventory table

Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).

Exchange Type Location / compartment Amount Unit Uncertainty Pedigree GWP share (%) Notes
Printed wiring board mounting plant technosphere GLO 5.2867e-07 p none declared: tdc-doc default ±50 % — 15.8 ███
Steel, low-alloyed, at plant technosphere RER 1.2731 kg none declared: tdc-doc default ±50 % — 13.2 ███
Copper, at regional storage technosphere RER 1.5255 kg none declared: tdc-doc default ±50 % — 11.9 ██
Polyethylene, HDPE, granulate, at plant technosphere RER 0.83345 kg none declared: tdc-doc default ±50 % — 9.2 ██
Connector, computer, peripherical type, at plant technosphere GLO 0.25552 kg none declared: tdc-doc default ±50 % — 8.1 ██
Aluminium, production mix, at plant technosphere RER 0.28397 kg none declared: tdc-doc default ±50 % — 6.6 █
Sawnwood, production mix, softwood, dried (u=10%), planed, at sawmill technosphere RER 0.021922 m3 none declared: tdc-doc default ±50 % — 6.4 █
Polyvinylchloride, at regional storage technosphere RER 0.46405 kg none declared: tdc-doc default ±50 % — 5.3 █
Energy-saving bulb, 11W, incl. integrated adapter, at plant technosphere RER 0.59564 p none declared: tdc-doc default ±50 % — 5.1 █
Wire drawing, copper technosphere RER 1.5255 kg none declared: tdc-doc default ±50 % — 2.8 █
Electricity, medium voltage, production ENTSO-E, at grid technosphere ENTSO-E 2.0686 kWh none declared: tdc-doc default ±50 % — 2.7 █
Chromium steel 18/8, at plant technosphere RER 0.092882 kg none declared: tdc-doc default ±50 % — 2.0 ·
Extrusion, plastic pipes technosphere RER 1.3604 kg none declared: tdc-doc default ±50 % — 1.7 ·
Electronics for control units technosphere RER 0.017523 kg none declared: tdc-doc default ±50 % — 1.6 ·
Extrusion, plastic pipes technosphere RER 1.2731 kg none declared: tdc-doc default ±50 % — 1.6 ·
Zinc coating, pieces technosphere RER 0.046759 m2 none declared: tdc-doc default ±50 % — 1.3 ·
Polycarbonate, at plant technosphere RER 0.021859 kg none declared: tdc-doc default ±50 % — 0.9 ·
Heat, heavy fuel oil, at industrial furnace 1MW technosphere CH 1.5984 MJ none declared: tdc-doc default ±50 % — 0.8 ·
Disposal, plastics, mixture, 15.3% water, to municipal incineration technosphere CH 0.063427 kg none declared: tdc-doc default ±50 % — 0.7 ·
Section bar extrusion, aluminium technosphere RER 0.20985 kg none declared: tdc-doc default ±50 % — 0.7 ·
Acrylonitrile-butadiene-styrene copolymer, ABS, at plant technosphere RER 0.020322 kg none declared: tdc-doc default ±50 % — 0.4 ·
Transport, freight, lorry, fleet average technosphere RER 0.44864 tkm none declared: tdc-doc default ±50 % — 0.4 ·
Polypropylene, granulate, at plant technosphere RER 0.023251 kg none declared: tdc-doc default ±50 % — 0.2 ·
Powder coating, aluminium sheet technosphere RER 0.0096841 m2 none declared: tdc-doc default ±50 % — 0.2 ·
Sheet rolling, aluminium technosphere RER 0.074541 kg none declared: tdc-doc default ±50 % — 0.2 ·
Chromium steel 18/8, at plant technosphere RER 0.0034743 kg none declared: tdc-doc default ±50 % — 0.1 ·
Chromium steel 18/8, at plant technosphere RER 0.0034743 kg none declared: tdc-doc default ±50 % — 0.1 ·
Powder coating, steel technosphere RER 0.0027835 m2 none declared: tdc-doc default ±50 % — 0.1 ·
Transport, freight, rail, electricity with shunting technosphere CH 0.89619 tkm none declared: tdc-doc default ±50 % — 0.0 ·
Tap water, at user technosphere CH 51.267 kg none declared: tdc-doc default ±50 % — 0.0 ·
Propane, butane, at refinery technosphere RER 4.7043e-04 kg none declared: tdc-doc default ±50 % — 0.0 ·

Data quality

0 of 31 direct exchanges carry a declared pedigree, 0 carry a distribution.

Field As declared by the publisher
Data generator / entry / validation data generator: Franziska Wyss (TREEZE); data entry: Franziska Wyss (TREEZE); validation (proof reading): Rolf Frischknecht (TREEZE)
extrapolations none
sampling procedure unknown
production volume na
uncertainty adjustments none
validation details Proof reading validation: 12.11.2013; Other validation: \Server\E\ESU-Docs\Projekte laufend\494 IEA Annex 57\EcoSpold\Haustechnik[494_ecospold_Sanitär_Elektro_v0.4.xlsx]X-Process;
time period comment undefined

Data gaps, proxies and assumptions

Item Class Value used Reason Effect
31 exchange(s) without declared uncertainty uncertainty fixed in the Monte Carlo the publisher declares no distribution ±50 % in the sensitivity check (Section 6.3)

Life cycle impact assessment (EF v3.1)

Per 1 m2. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.

Impact category Indicator Unit Result 2.5 % 97.5 % GSD²
Acidification Accumulated Exceedance (AE) mol H+ eq 0.3504 0.307 0.4819 1.27
Climate change-Biogenic Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.06852 0.04689 0.1573 1.87
Climate change-Fossil Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 20.55 19.82 28.84 1.22
Climate change-Land use and land use change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.009951 0.008661 0.01609 1.36
Climate change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 20.63 19.91 28.96 1.22
EF-particulate Matter Impact on human health disease incidence 1.992e-06 1.913e-06 2.999e-06 1.25
Ecotoxicity, freshwater_inorganics Comparative Toxic Unit for ecosystems (CTUe) CTUe 152.1 147.2 352.3 1.58
Ecotoxicity, freshwater_organics Comparative Toxic Unit for ecosystems (CTUe) CTUe 2.763 2.744 5.337 1.59
Ecotoxicity, freshwater Comparative Toxic Unit for ecosystems (CTUe) CTUe 154.9 150.8 360 1.57
Eutrophication marine Fraction of nutrients reaching marine end compartment (N) kg N eq 0.03379 0.0298 0.05537 1.41
Eutrophication, freshwater Fraction of nutrients reaching freshwater end compartment (P) kg P eq 0.1024 0.06445 0.6312 3.4
Eutrophication, terrestrial Accumulated Exceedance (AE) mol N eq 0.392 0.3319 0.6112 1.38
Human toxicity, cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 4.118e-08 3.733e-08 1.131e-07 1.8
Human toxicity, cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 8.267e-09 7.550e-09 1.863e-08 1.62
Human toxicity, cancer Comparative Toxic Unit for human (CTUh) CTUh 4.944e-08 4.732e-08 1.265e-07 1.68
Human toxicity, non-cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 3.819e-06 3.152e-06 1.058e-05 1.86
Human toxicity, non-cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 2.956e-07 1.915e-07 5.403e-07 1.7
Human toxicity, non-cancer Comparative Toxic Unit for human (CTUh) CTUh 4.115e-06 3.478e-06 1.088e-05 1.8
Ionising radiation, human health Human exposure efficiency relative to U235 kBq U235 eq 5.895 2.254 35.94 4.2
Land use Soil quality index pt (soil quality index) 2387 2039 3065 1.23
Ozone depletion Ozone Depletion Potential (ODP) kg CFC-11 eq 9.165e-07 7.524e-07 1.744e-06 1.53
Photochemical ozone formation - human health Tropospheric ozone concentration increase kg NMVOC eq 0.1206 0.113 0.1699 1.23
Resource use, fossils Abiotic resource depletion fossil fuels (ADP-fossil) MJ 321.4 301.4 478.7 1.27
Resource use, minerals and metals Abiotic resource depletion (ADP ultimate reserve) kg Sb eq 0.002567 0.002212 0.003516 1.27
Water use User deprivation potential (deprivation-weighted water consumption) m3 world eq deprived 2.386 -9822 4942 —

Climate change 20.63 kg CO2 eq per m2. Main contributors: Printed wiring board mounting plant 16 %; Steel, low-alloyed, at plant 13 %; Copper, at regional storage 12 %; Polyethylene, HDPE, granulate, at plant 9 %; Connector, computer, peripherical type, at plant 8 %; Aluminium, production mix, at plant 7 %.

Interpretation

Significant issues

Direct exchanges dominating climate change: Printed wiring board mounting plant 16 %; Steel, low-alloyed, at plant 13 %; Copper, at regional storage 12 %; Polyethylene, HDPE, granulate, at plant 9 %; Connector, computer, peripherical type, at plant 8 %; Aluminium, production mix, at plant 7 %. Most sensitive exchanges (Section 6.3): Printed wiring board mounting plant [GLO] (-7.9 / +7.9 %); Steel, low-alloyed, at plant [RER] (-6.6 / +6.6 %); Copper, at regional storage [RER] (-5.9 / +5.9 %).

Independent recalculation

Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026):

Category Graph Published Graph / published
Acidification 0.3504 0.3541 0.990
Climate change-Biogenic 0.06852 0.06852 1.000
Climate change-Fossil 20.55 20.55 1.000
Climate change-Land use and land use change 0.009951 0.009951 1.000
Climate change 20.63 20.63 1.000
EF-particulate Matter 1.992e-06 1.992e-06 1.000
Ecotoxicity, freshwater_inorganics 152.1 157.4 0.967
Ecotoxicity, freshwater_organics 2.763 2.726 1.014
Ecotoxicity, freshwater 154.9 159.9 0.969
Eutrophication marine 0.03379 0.03379 1.000
Eutrophication, freshwater 0.1024 0.1024 1.000
Eutrophication, terrestrial 0.392 0.4018 0.976
Human toxicity, cancer_inorganics 4.118e-08 4.102e-08 1.004
Human toxicity, cancer_organics 8.267e-09 8.267e-09 1.000
Human toxicity, cancer 4.944e-08 4.929e-08 1.003
Human toxicity, non-cancer_inorganics 3.819e-06 3.812e-06 1.002
Human toxicity, non-cancer_organics 2.956e-07 2.956e-07 1.000
Human toxicity, non-cancer 4.115e-06 4.107e-06 1.002
Ionising radiation, human health 5.895 5.895 1.000
Land use 2387 2210 1.080
Ozone depletion 9.165e-07 9.165e-07 1.000
Photochemical ozone formation - human health 0.1206 0.1206 1.000
Resource use, fossils 321.4 321.5 1.000
Resource use, minerals and metals 0.002567 0.002537 1.012
Water use 2.386 3.121 0.765
Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like.
Also published by BAFU for this dataset: IPCC 2021 GWP100 20.63 kg CO2 eq; Ecological Scarcity
2021 total 8.194e+04 UBP.

Sensitivity check

One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.

Exchange Base Low / high Range Δ GWP100 (%) Δ other categories (max %)
Printed wiring board mounting plant [GLO] 5.287e-07 p ×0.5 / ×1.5 none declared: tdc-doc default ±50 % -7.9 / +7.9 11.0 (Human toxicity, cancer_organics)
Steel, low-alloyed, at plant [RER] 1.273 kg ×0.5 / ×1.5 none declared: tdc-doc default ±50 % -6.6 / +6.6 6.9 (Human toxicity, cancer_organics)
Copper, at regional storage [RER] 1.526 kg ×0.5 / ×1.5 none declared: tdc-doc default ±50 % -5.9 / +5.9 40.7 (Human toxicity, non-cancer_organics)
Polyethylene, HDPE, granulate, at plant [RER] 0.8335 kg ×0.5 / ×1.5 none declared: tdc-doc default ±50 % -4.6 / +4.6 9.4 (Resource use, fossils)
Connector, computer, peripherical type, at plant [GLO] 0.2555 kg ×0.5 / ×1.5 none declared: tdc-doc default ±50 % -4.1 / +4.1 5.5 (Climate change-Land use and land use change)
Aluminium, production mix, at plant [RER] 0.284 kg ×0.5 / ×1.5 none declared: tdc-doc default ±50 % -3.3 / +3.3 9.3 (Climate change-Land use and land use change)
Sawnwood, production mix, softwood, dried (u=10%), planed, at sawmill [RER] 0.02192 m3 ×0.5 / ×1.5 none declared: tdc-doc default ±50 % -3.2 / +3.2 44.2 (Land use)
Polyvinylchloride, at regional storage [RER] 0.4641 kg ×0.5 / ×1.5 none declared: tdc-doc default ±50 % -2.6 / +2.6 23.2 (Ozone depletion)
Energy-saving bulb, 11W, incl. integrated adapter, at plant [RER] 0.5956 p ×0.5 / ×1.5 none declared: tdc-doc default ±50 % -2.6 / +2.6 4.2 (Water use)
Wire drawing, copper [RER] 1.526 kg ×0.5 / ×1.5 none declared: tdc-doc default ±50 % -1.4 / +1.4 2.7 (Climate change-Biogenic)
Electricity, medium voltage, production ENTSO-E, at grid [ENTSO-E] 2.069 kWh ×0.5 / ×1.5 none declared: tdc-doc default ±50 % -1.4 / +1.4 7.0 (Climate change-Biogenic)
Chromium steel 18/8, at plant [RER] 0.09288 kg ×0.5 / ×1.5 none declared: tdc-doc default ±50 % -1.0 / +1.0 1.0 (Climate change-Fossil)
Extrusion, plastic pipes [RER] 1.36 kg ×0.5 / ×1.5 none declared: tdc-doc default ±50 % -0.8 / +0.8 2.4 (Climate change-Biogenic)
Electronics for control units [RER] 0.01752 kg ×0.5 / ×1.5 none declared: tdc-doc default ±50 % -0.8 / +0.8 3.6 (Resource use, minerals and metals)
Extrusion, plastic pipes [RER] 1.273 kg ×0.5 / ×1.5 none declared: tdc-doc default ±50 % -0.8 / +0.8 2.3 (Climate change-Biogenic)

Uncertainty analysis

Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.

Comparison with other data

No other location of this dataset in the graph.

Conclusions and limitations

GWP100 20.63 kg CO2 eq per m2 (95 % interval 19.91–28.96). Dominant contributors: Printed wiring board mounting plant 16 %; Steel, low-alloyed, at plant 13 %; Copper, at regional storage 12 %; Polyethylene, HDPE, granulate, at plant 9 %; Connector, computer, peripherical type, at plant 8 %; Aluminium, production mix, at plant 7 %. Most sensitive: Printed wiring board mounting plant [GLO] (-7.9 / +7.9 %); Steel, low-alloyed, at plant [RER] (-6.6 / +6.6 %); Copper, at regional storage [RER] (-5.9 / +5.9 %). final control: 0 failed, 1 warning(s) (Section 7). The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.

Final control

Item Status Detail
reference flow PASS production amount 1.0 m2
closure: sum of direct contributions = dataset score (all 25 categories) PASS largest relative gap 6.0e-16
independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) PASS graph / published = 1; categories within ±5 %: 23/25
every technosphere input of the EcoSpold delivery is in the graph PASS all present (bafu_links_check.py)
uncertainty declared on the direct exchanges WARN 0/31 exchanges carry a distribution (0 %); the others enter the Monte Carlo as fixed values
Monte Carlo 95 % interval contains the deterministic score PASS 20.63 in [19.91, 28.96]
time period declared PASS 2013-01/2013-12
geography is a known location code PASS CH
sources cited PASS 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them

References

  1. Klingler, Kasser (2011) Graue Energie von Sanitär- und Elektroanlagen. Project report. Page: 100. BfE. BfE. Type: Separate publication Source: Report First author: Klingler Other authors: Kasser Year: 2011 Title of anthology: Project report Place of publication: BfE Publisher: BfE — published source; as declared by BAFU (not found in OpenAlex/Crossref)
  2. Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — database; dataset citation
  3. International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva.
  4. Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. (tdc-doc method reference; title, version and year to verify against the user's copy)
  5. European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra.
  6. Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236

Annex — licence and terms of use

BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.


To suggest a correction or a dataset that does not exist yet, use Propose a dataset.