Table of Contents

Transport, district heat, large area network, for hot water — CH

Dataset documentation and final control (tdc-doc, imported mode)
Open this dataset in OpenData

Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Transport, district heat, large area network, for hot water [CH], per 1 MJ. EF v3.1 climate change 5.998e-04 kg CO2 eq (Monte Carlo 95 % interval 5.597e-04–7.620e-04). Main contributors: Electricity, medium voltage, at grid 41 %; Reinforcing steel, at plant 23 %; Concrete, normal, at plant 23 %; Wire drawing, steel 7 %; Glass wool mat, at plant 2 %; Transport, freight, lorry, 16t-32t gross weight, fleet avera… 1 %. Status: final control passed.
Item Value
Dataset name Transport, district heat, large area network, for hot water
Dataset UUID / graph id ad8e6ef1-c36b-3cd8-a3d7-21ae34ecfd20 / activity:transport_district_heat_large_area_network_for_hot_water__ch
Reference product, unit Transport, district heat, large area network, for hot water, 1 MJ
Location CH
Time period 2000-01/2000-12
Category energy supply, kbob recommendation / district heat, delivered
Source database BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1
Publisher Swiss Federal Office for the Environment (FOEN/BAFU)
Background database BAFU 2026 v1 (graph bafuquery-db)
LCIA method EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix)
Status final control passed
Documented by tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17

Introduction

The lifetime of the network is assumed to be 30 years. Typical heat loss is between 5 and 10% (not including heat exchanger at the consumer side).; UUID: ad8e6ef1-c36b-3cd8-a3d7-21ae34ecfd20

This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.

Goal and scope

Function, functional unit and reference flow

Reference flow: 1 MJ of Transport, district heat, large area network, for hot water (CH). All results are given per unit of the reference flow.

System boundary

The construction and operation of the district heating network. It is based on pipes of different diameters with concrete jacket pipes. The production of the heat is not part of this system.

Technology

average technology

Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).

LCIA method

EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.

Life cycle inventory

Inventory table

Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).

Exchange Type Location / compartment Amount Unit Uncertainty Pedigree GWP share (%) Notes
Electricity, medium voltage, at grid technosphere CH 0.0027778 kWh lognormal, GSD² 1.13 (2,1,2,1,1,4) 41.5 ████████
Reinforcing steel, at plant technosphere RER 1.0000e-04 kg lognormal, GSD² 1.13 (2,1,2,1,1,4) 23.4 █████
Concrete, normal, at plant technosphere CH 5.9091e-07 m3 lognormal, GSD² 1.13 (2,1,2,1,1,4) 22.5 █████
Wire drawing, steel technosphere RER 1.0000e-04 kg lognormal, GSD² 1.13 (2,1,2,1,1,4) 6.5 █
Glass wool mat, at plant technosphere CH 7.0000e-06 kg lognormal, GSD² 1.13 (2,1,2,1,1,4) 1.7 ·
Transport, freight, lorry, 16t-32t gross weight, fleet average technosphere CH 5.0000e-05 tkm lognormal, GSD² 2.02 (2,1,2,1,1,4) 1.4 ·
Polyethylene, HDPE, granulate, at plant technosphere RER 3.0000e-06 kg lognormal, GSD² 1.13 (2,1,2,1,1,4) 1.1 ·
Polyurethane, rigid foam, at plant technosphere RER 1.0000e-06 kg lognormal, GSD² 1.13 (2,1,2,1,1,4) 0.7 ·
Excavation, skid-steer loader technosphere RER 4.0000e-06 m3 lognormal, GSD² 1.13 (2,1,2,1,1,4) 0.4 ·
Disposal, polyurethane, 0.2% water, to municipal incineration technosphere CH 6.0000e-07 kg lognormal, GSD² 1.13 (2,1,2,1,1,4) 0.3 ·
Disposal, inert waste, 5% water, to construction waste landfill technosphere CH 0.00133 kg lognormal, GSD² 1.13 (2,1,2,1,1,4) 0.2 ·
Extrusion, plastic pipes technosphere RER 3.0000e-06 kg lognormal, GSD² 1.13 (2,1,2,1,1,4) 0.1 ·
Transport, freight, rail, electricity with shunting technosphere CH 6.0000e-05 tkm lognormal, GSD² 2.02 (2,1,2,1,1,4) 0.1 ·

Data quality

13 of 13 direct exchanges carry a declared pedigree, 13 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 2.0 · completeness 1.0 · temporal 2.0 · geographical 1.0 · technological 1.0 · sample size 4.0.

Field As declared by the publisher
Data generator / entry / validation data generator: Roland Steiner; data entry: Roland Steiner; validation (proof reading): Roland Steiner
extrapolations none
sampling procedure unknown
production volume na
uncertainty adjustments none
validation details Proof reading validation: automatic validation in Excel; Other validation: none;
time period comment undefined

Data gaps, proxies and assumptions

None recorded.

Life cycle impact assessment (EF v3.1)

Per 1 MJ. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.

Impact category Indicator Unit Result 2.5 % 97.5 % GSD²
Acidification Accumulated Exceedance (AE) mol H+ eq 1.025e-06 1.012e-06 1.343e-06 1.16
Climate change-Biogenic Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 7.543e-06 5.560e-06 1.205e-05 1.48
Climate change-Fossil Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 5.912e-04 5.515e-04 7.502e-04 1.17
Climate change-Land use and land use change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 1.069e-06 8.084e-07 1.600e-06 1.43
Climate change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 5.998e-04 5.597e-04 7.620e-04 1.17
EF-particulate Matter Impact on human health disease incidence 2.453e-11 2.158e-11 3.822e-11 1.33
Ecotoxicity, freshwater_inorganics Comparative Toxic Unit for ecosystems (CTUe) CTUe 0.001688 0.001573 0.003316 1.45
Ecotoxicity, freshwater_organics Comparative Toxic Unit for ecosystems (CTUe) CTUe 4.856e-05 4.613e-05 9.768e-05 1.58
Ecotoxicity, freshwater Comparative Toxic Unit for ecosystems (CTUe) CTUe 0.001737 0.001629 0.003379 1.44
Eutrophication marine Fraction of nutrients reaching marine end compartment (N) kg N eq 4.306e-07 4.124e-07 5.689e-07 1.18
Eutrophication, freshwater Fraction of nutrients reaching freshwater end compartment (P) kg P eq 3.198e-07 1.927e-07 1.648e-06 3.07
Eutrophication, terrestrial Accumulated Exceedance (AE) mol N eq 3.748e-06 3.612e-06 4.902e-06 1.17
Human toxicity, cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 1.863e-13 1.865e-13 4.512e-13 1.58
Human toxicity, cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 2.364e-13 2.010e-13 3.490e-13 1.33
Human toxicity, cancer Comparative Toxic Unit for human (CTUh) CTUh 4.228e-13 4.168e-13 7.377e-13 1.34
Human toxicity, non-cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 7.644e-12 7.447e-12 1.896e-11 1.6
Human toxicity, non-cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 2.218e-13 2.122e-13 3.820e-13 1.36
Human toxicity, non-cancer Comparative Toxic Unit for human (CTUh) CTUh 7.865e-12 7.684e-12 1.930e-11 1.58
Ionising radiation, human health Human exposure efficiency relative to U235 kBq U235 eq 0.001962 7.238e-04 0.01085 4.16
Land use Soil quality index pt (soil quality index) 0.00525 0.003758 0.008861 1.56
Ozone depletion Ozone Depletion Potential (ODP) kg CFC-11 eq 3.507e-11 2.893e-11 4.992e-11 1.33
Photochemical ozone formation - human health Tropospheric ozone concentration increase kg NMVOC eq 1.378e-06 1.330e-06 2.032e-06 1.25
Resource use, fossils Abiotic resource depletion fossil fuels (ADP-fossil) MJ 0.02168 0.01807 0.03066 1.3
Resource use, minerals and metals Abiotic resource depletion (ADP ultimate reserve) kg Sb eq 2.407e-09 2.212e-09 3.907e-09 1.35
Water use User deprivation potential (deprivation-weighted water consumption) m3 world eq deprived 2.017e-04 -0.6368 0.3359 —

Climate change 5.998e-04 kg CO2 eq per MJ. Main contributors: Electricity, medium voltage, at grid 41 %; Reinforcing steel, at plant 23 %; Concrete, normal, at plant 23 %; Wire drawing, steel 7 %; Glass wool mat, at plant 2 %; Transport, freight, lorry, 16t-32t gross weight, fleet avera… 1 %.

Interpretation

Significant issues

Direct exchanges dominating climate change: Electricity, medium voltage, at grid 41 %; Reinforcing steel, at plant 23 %; Concrete, normal, at plant 23 %; Wire drawing, steel 7 %; Glass wool mat, at plant 2 %; Transport, freight, lorry, 16t-32t gross weight, fleet avera… 1 %. Most sensitive exchanges (Section 6.3): Electricity, medium voltage, at grid [CH] (-4.6 / +5.2 %); Reinforcing steel, at plant [RER] (-2.6 / +3.0 %); Concrete, normal, at plant [CH] (-2.5 / +2.8 %).

Independent recalculation

Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026):

Category Graph Published Graph / published
Acidification 1.025e-06 1.340e-06 0.765
Climate change-Biogenic 7.543e-06 7.543e-06 1.000
Climate change-Fossil 5.912e-04 5.912e-04 1.000
Climate change-Land use and land use change 1.069e-06 1.069e-06 1.000
Climate change 5.998e-04 5.998e-04 1.000
EF-particulate Matter 2.453e-11 2.453e-11 1.000
Ecotoxicity, freshwater_inorganics 0.001688 0.001776 0.950
Ecotoxicity, freshwater_organics 4.856e-05 4.772e-05 1.018
Ecotoxicity, freshwater 0.001737 0.001822 0.953
Eutrophication marine 4.306e-07 4.298e-07 1.002
Eutrophication, freshwater 3.198e-07 3.198e-07 1.000
Eutrophication, terrestrial 3.748e-06 4.093e-06 0.916
Human toxicity, cancer_inorganics 1.863e-13 1.821e-13 1.023
Human toxicity, cancer_organics 2.364e-13 2.364e-13 1.000
Human toxicity, cancer 4.228e-13 4.185e-13 1.010
Human toxicity, non-cancer_inorganics 7.644e-12 7.446e-12 1.027
Human toxicity, non-cancer_organics 2.218e-13 2.218e-13 1.000
Human toxicity, non-cancer 7.865e-12 7.667e-12 1.026
Ionising radiation, human health 0.001962 0.001962 1.000
Land use 0.00525 0.00401 1.309
Ozone depletion 3.507e-11 3.507e-11 1.000
Photochemical ozone formation - human health 1.378e-06 1.378e-06 1.000
Resource use, fossils 0.02168 0.02168 1.000
Resource use, minerals and metals 2.407e-09 2.082e-09 1.156
Water use 2.017e-04 2.273e-04 0.888
Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like.
Also published by BAFU for this dataset: IPCC 2021 GWP100 5.996e-04 kg CO2 eq; Ecological Scarcity
2021 total 1.888 UBP.

Sensitivity check

One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.

Exchange Base Low / high Range Δ GWP100 (%) Δ other categories (max %)
Electricity, medium voltage, at grid [CH] 0.002778 kWh ×0.888 / ×1.13 lognormal, GSD² 1.13 -4.6 / +5.2 12.1 (Ionising radiation, human health)
Reinforcing steel, at plant [RER] 1.000e-04 kg ×0.888 / ×1.13 lognormal, GSD² 1.13 -2.6 / +3.0 7.5 (Human toxicity, cancer_inorganics)
Concrete, normal, at plant [CH] 5.909e-07 m3 ×0.888 / ×1.13 lognormal, GSD² 1.13 -2.5 / +2.8 2.9 (Climate change-Fossil)
Transport, freight, lorry, 16t-32t gross weight, fleet average [CH] 5.000e-05 tkm ×0.503 / ×1.99 lognormal, GSD² 2.02 -0.7 / +1.4 3.9 (Photochemical ozone formation - human health)
Wire drawing, steel [RER] 1.000e-04 kg ×0.888 / ×1.13 lognormal, GSD² 1.13 -0.7 / +0.8 1.9 (Climate change-Land use and land use change)
Glass wool mat, at plant [CH] 7.000e-06 kg ×0.888 / ×1.13 lognormal, GSD² 1.13 -0.2 / +0.2 2.6 (Human toxicity, cancer_organics)
Polyethylene, HDPE, granulate, at plant [RER] 3.000e-06 kg ×0.888 / ×1.13 lognormal, GSD² 1.13 -0.1 / +0.1 0.4 (Ecotoxicity, freshwater_organics)
Polyurethane, rigid foam, at plant [RER] 1.000e-06 kg ×0.888 / ×1.13 lognormal, GSD² 1.13 -0.1 / +0.1 1.2 (Ecotoxicity, freshwater_inorganics)
Transport, freight, rail, electricity with shunting [CH] 6.000e-05 tkm ×0.503 / ×1.99 lognormal, GSD² 2.02 -0.1 / +0.1 1.0 (Human toxicity, non-cancer_organics)
Excavation, skid-steer loader [RER] 4.000e-06 m3 ×0.888 / ×1.13 lognormal, GSD² 1.13 -0.0 / +0.0 0.4 (Eutrophication, terrestrial)
Disposal, polyurethane, 0.2% water, to municipal incineration [CH] 6.000e-07 kg ×0.888 / ×1.13 lognormal, GSD² 1.13 -0.0 / +0.0 0.0 (Climate change-Fossil)
Disposal, inert waste, 5% water, to construction waste landfill [CH] 0.00133 kg ×0.888 / ×1.13 lognormal, GSD² 1.13 -0.0 / +0.0 1.2 (Eutrophication, freshwater)
Extrusion, plastic pipes [RER] 3.000e-06 kg ×0.888 / ×1.13 lognormal, GSD² 1.13 -0.0 / +0.0 0.0 (Land use)

Uncertainty analysis

Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.

Comparison with other data

No other location of this dataset in the graph.

Conclusions and limitations

GWP100 5.998e-04 kg CO2 eq per MJ (95 % interval 5.597e-04–7.620e-04). Dominant contributors: Electricity, medium voltage, at grid 41 %; Reinforcing steel, at plant 23 %; Concrete, normal, at plant 23 %; Wire drawing, steel 7 %; Glass wool mat, at plant 2 %; Transport, freight, lorry, 16t-32t gross weight, fleet avera… 1 %. Most sensitive: Electricity, medium voltage, at grid [CH] (-4.6 / +5.2 %); Reinforcing steel, at plant [RER] (-2.6 / +3.0 %); Concrete, normal, at plant [CH] (-2.5 / +2.8 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.

Final control

Item Status Detail
reference flow PASS production amount 1.0 MJ
closure: sum of direct contributions = dataset score (all 25 categories) PASS largest relative gap 4.1e-16
independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) PASS graph / published = 1; categories within ±5 %: 20/25
every technosphere input of the EcoSpold delivery is in the graph PASS all present (bafu_links_check.py)
uncertainty declared on the direct exchanges PASS 13/13 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values
Monte Carlo 95 % interval contains the deterministic score PASS 5.998e-04 in [5.597e-04, 7.620e-04]
time period declared PASS 2000-01/2000-12
geography is a known location code PASS CH
sources cited PASS 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them

References

  1. Jungbluth N., Chudacoff M., Dauriat A., Dinkel F., Doka G., Faist Emmenegger M., Gnansounou E., Kljun N., Spielmann M., Stettler C., Sutter J. (2007) Life Cycle Inventories of Bioenergy. Final report ecoinvent data v2.0. Volume: 17. Swiss Centre for LCI, ESU. Duebendorf and Uster, CH. Type: Measurement on site Source: CD-ROM First author: Jungbluth N. Other authors: Chudacoff M., Dauriat A., Dinke… — published source; as declared by BAFU (not found in OpenAlex/Crossref)
  2. Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — database; dataset citation
  3. International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva.
  4. Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. (tdc-doc method reference; title, version and year to verify against the user's copy)
  5. European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra.
  6. Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236

Annex — licence and terms of use

BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.


To suggest a correction or a dataset that does not exist yet, use Propose a dataset.