Table of Contents

Photovoltaic laminate, single-Si, at plant — RER

Dataset documentation and final control (tdc-doc, imported mode)
Open this dataset in OpenData

Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Photovoltaic laminate, single-Si, at plant [RER], per 1 m2. EF v3.1 climate change 86.48 kg CO2 eq (Monte Carlo 95 % interval 47.47–303.1). Main contributors: Photovoltaic cell, single-Si, at regional storage 67 %; Solar glass, low-iron, at regional storage 11 %; Electricity, medium voltage, production ENTSO-E, at grid 4 %; Glass fibre reinforced plastic, polyamide, injection mouldin… 3 %; Ethylvinylacetate, foil, at plant 3 %; Polyvinylfluoride film, at plant 3 %. Status: final control passed.
Item Value
Dataset name Photovoltaic laminate, single-Si, at plant
Dataset UUID / graph id b8211571-cfa9-3f53-bc7c-4ecd67fbf8de / activity:photovoltaic_laminate_single_si_at_plant__rer
Reference product, unit Photovoltaic laminate, single-Si, at plant, 1 m2
Location RER
Time period 1992-01/2020-12
Category photovoltaic / production of components
Source database BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1
Publisher Swiss Federal Office for the Environment (FOEN/BAFU)
Background database BAFU 2026 v1 (graph bafuquery-db)
LCIA method EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix)
Status final control passed
Documented by tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17

Introduction

Unit process raw data for 1 m2 of PV laminate. Investigated for the production of solar laminates with 60 solar cells and an area of 1.6m2.; Synonyms: monocrystalline, single crystalline, silicon; UUID: b8211571-cfa9-3f53-bc7c-4ecd67fbf8de

This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.

Goal and scope

Function, functional unit and reference flow

Reference flow: 1 m2 of Photovoltaic laminate, single-Si, at plant (RER). All results are given per unit of the reference flow.

System boundary

Production of the cell matrix, cutting of foils and washing of glass, production of laminate and isolation. Data for direct air emissions (except NVMOC) and water emissions were not available.

Technology

Average production technology.

Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).

LCIA method

EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.

Life cycle inventory

Inventory table

Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).

Exchange Type Location / compartment Amount Unit Uncertainty Pedigree GWP share (%) Notes
Photovoltaic cell, single-Si, at regional storage technosphere RER 0.93541 m2 lognormal, GSD² 3.06 (1,4,4,3,1,3) 67.2 █████████████
Solar glass, low-iron, at regional storage technosphere RER 8.8125 kg lognormal, GSD² 1.33 (1,4,4,3,3,3) 11.3 ██
Electricity, medium voltage, production ENTSO-E, at grid technosphere ENTSO-E 13.975 kWh lognormal, GSD² 1.09 (2,2,1,1,1,3) 4.4 █
Glass fibre reinforced plastic, polyamide, injection moulding, at plant technosphere RER 0.295 kg lognormal, GSD² 1.24 (1,4,4,3,1,3) 2.9 █
Ethylvinylacetate, foil, at plant technosphere RER 0.875 kg lognormal, GSD² 1.24 (1,4,4,3,1,3) 2.9 █
Polyvinylfluoride film, at plant technosphere US 0.11187 kg lognormal, GSD² 1.24 (1,4,4,3,1,3) 2.7 █
Tempering, flat glass technosphere RER 8.8125 kg lognormal, GSD² 1.24 (1,4,4,3,1,3) 2.5 █
Polyethylene terephthalate, granulate, amorphous, at plant technosphere RER 0.34562 kg lognormal, GSD² 1.24 (1,4,4,3,1,3) 1.1 ·
Photovoltaic panel factory technosphere GLO 4.0000e-06 p lognormal, GSD² 3.06 (1,4,4,3,1,3) 1.1 ·
Corrugated board, mixed fibre, single wall, at plant technosphere RER 0.7625 kg lognormal, GSD² 1.24 (1,4,4,3,1,3) 0.8 ·
Diode, unspecified, at plant technosphere GLO 0.0028125 kg lognormal, GSD² 1.34 (3,4,4,3,1,5) 0.6 ·
Transport, freight, lorry, fleet average technosphere RER 2.5614 tkm lognormal, GSD² 2.1 — 0.6 ·
Silicone product, at plant technosphere RER 0.12187 kg lognormal, GSD² 1.24 (1,4,4,3,1,3) 0.4 ·
Transport, freight, rail technosphere RER 15.363 tkm lognormal, GSD² 2.1 — 0.3 ·
EUR-flat pallet technosphere RER 0.05 p lognormal, GSD² 1.34 (3,4,4,3,1,5) 0.3 ·
Copper, at regional storage technosphere RER 0.1025 kg lognormal, GSD² 1.24 (1,4,4,3,1,3) 0.2 ·
Tin, at regional storage technosphere RER 0.012875 kg lognormal, GSD² 1.34 (3,4,4,3,1,5) 0.2 ·
Hydrogen fluoride, at plant technosphere GLO 0.062375 kg lognormal, GSD² 1.34 (3,4,4,3,1,5) 0.2 ·
Potassium hydroxide, at regional storage technosphere RER 0.051438 kg lognormal, GSD² 1.34 (3,4,4,3,1,5) 0.1 ·
Disposal, plastics, mixture, 15.3% water, to municipal incineration technosphere CH 0.028063 kg lognormal, GSD² 1.24 (1,4,4,3,1,3) 0.1 ·
1-propanol, at plant technosphere RER 0.015875 kg lognormal, GSD² 1.24 (1,4,4,3,1,3) 0.1 ·
Polyethylene, HDPE, granulate, at plant technosphere RER 0.02375 kg lognormal, GSD² 1.34 (3,4,4,3,1,5) 0.1 ·
Wire drawing, copper technosphere RER 0.1025 kg lognormal, GSD² 1.24 (1,4,4,3,1,3) 0.0 ·
Soap, at plant technosphere RER 0.011562 kg lognormal, GSD² 1.34 (3,4,4,3,1,5) 0.0 ·
Disposal, municipal solid waste, 22.9% water, to municipal incineration technosphere CH 0.03 kg lognormal, GSD² 1.24 (1,4,4,3,1,3) 0.0 ·
Disposal, polyvinylfluoride, 0.2% water, to municipal incineration technosphere CH 0.0042938 kg lognormal, GSD² 1.24 (1,4,4,3,1,3) 0.0 ·
Disposal, used mineral oil, 10% water, to hazardous waste incineration technosphere CH 0.0016062 kg lognormal, GSD² 1.24 (1,4,4,3,1,3) 0.0 ·
Treatment, sewage, from residence, to wastewater treatment, class 2 technosphere CH 0.0045281 m3 lognormal, GSD² 1.24 (1,4,4,3,1,3) 0.0 ·
Tap water, water balance according to MoeK 2013, at user technosphere RER 5.0312 kg lognormal, GSD² 1.24 (1,4,4,3,1,3) 0.0 ·
Diesel, burned in building machine, average technosphere CH 0.00875 MJ lognormal, GSD² 2.12 (3,4,4,3,1,5) 0.0 ·
Lead, at regional storage technosphere RER 7.2500e-04 kg lognormal, GSD² 1.34 (3,4,4,3,1,5) 0.0 ·
Isopropanol, at plant technosphere RER 1.4687e-04 kg lognormal, GSD² 1.34 (3,4,4,3,1,5) 0.0 ·
Carbon Dioxide (fossil) elementary air/Ground level / Urban (>1000 people/s… 0.021812 kg lognormal, GSD² 1.6 (3,4,5,3,1,5) 0.0 ·
Waste Heat elementary air/Ground level / Urban (>1000 people/s… 50.312 MJ lognormal, GSD² 1.6 (3,4,5,3,1,5) 0.0 ·
Non-methane Volatile Organic Compounds elementary air/Ground level / Urban (>1000 people/s… 0.0080625 kg lognormal, GSD² 1.85 (3,4,5,3,1,5) 0.0 ·
Water vapour elementary air/Unknown 5.0312e-04 m3 lognormal, GSD² 1.85 — 0.0 ·

Data quality

33 of 36 direct exchanges carry a declared pedigree, 36 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 1.82 · completeness 3.94 · temporal 4.0 · geographical 2.94 · technological 1.06 · sample size 3.79.

Field As declared by the publisher
Data generator / entry / validation data generator: Philippe Stolz (TREEZE); data entry: Philippe Stolz (TREEZE); validation (proof reading): Rolf Frischknecht (TREEZE)
extrapolations Assumption for laminate production with data for panels. Materials for frames neglected.
sampling procedure Environmental reports, direct contacts with factory representatives and publication of plant data.
production volume Approximately 99000 MW for total c-Si in 2018
uncertainty adjustments
validation details Proof reading validation: 30.09.2020; Other validation: G:\Projekte laufend\174 Photovoltaic, IEA Task 12\2017 Global supply chain\EcoSpold[174-photovoltaics-global-supply-chain-v2.5.xlsx]X-Process;
time period comment Date of data investigation. Some older data from 2001. Demand of electricity updated for 2018.

Data gaps, proxies and assumptions

None recorded.

Life cycle impact assessment (EF v3.1)

Per 1 m2. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.

Impact category Indicator Unit Result 2.5 % 97.5 % GSD²
Acidification Accumulated Exceedance (AE) mol H+ eq 0.2994 0.2095 0.8245 2.01
Climate change-Biogenic Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.5574 0.2223 2.62 3.52
Climate change-Fossil Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 85.89 47.23 300.8 2.67
Climate change-Land use and land use change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.03308 0.0244 0.08914 1.95
Climate change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 86.48 47.47 303.1 2.67
EF-particulate Matter Impact on human health disease incidence 2.821e-06 1.895e-06 2.300e-05 3.54
Ecotoxicity, freshwater_inorganics Comparative Toxic Unit for ecosystems (CTUe) CTUe 729.5 344.7 3721 3.35
Ecotoxicity, freshwater_organics Comparative Toxic Unit for ecosystems (CTUe) CTUe 9.008 6.681 29.39 2.14
Ecotoxicity, freshwater Comparative Toxic Unit for ecosystems (CTUe) CTUe 738.5 356.4 3754 3.32
Eutrophication marine Fraction of nutrients reaching marine end compartment (N) kg N eq 0.1577 0.07581 0.6261 3.03
Eutrophication, freshwater Fraction of nutrients reaching freshwater end compartment (P) kg P eq 0.03516 0.02017 0.1789 3.23
Eutrophication, terrestrial Accumulated Exceedance (AE) mol N eq 0.7653 0.5021 2.53 2.31
Human toxicity, cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 1.844e-08 1.243e-08 1.172e-07 3.16
Human toxicity, cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 2.905e-08 1.569e-08 1.097e-07 2.84
Human toxicity, cancer Comparative Toxic Unit for human (CTUh) CTUh 4.749e-08 2.939e-08 2.099e-07 2.9
Human toxicity, non-cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 1.283e-06 8.330e-07 7.689e-06 3.09
Human toxicity, non-cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 5.347e-08 3.940e-08 1.540e-07 2
Human toxicity, non-cancer Comparative Toxic Unit for human (CTUh) CTUh 1.336e-06 8.760e-07 7.799e-06 3.04
Ionising radiation, human health Human exposure efficiency relative to U235 kBq U235 eq 28.01 7.024 249.8 6.42
Land use Soil quality index pt (soil quality index) 759.4 510.2 2499 2.21
Ozone depletion Ozone Depletion Potential (ODP) kg CFC-11 eq 3.172e-06 1.719e-06 1.289e-05 2.9
Photochemical ozone formation - human health Tropospheric ozone concentration increase kg NMVOC eq 0.2581 0.1754 0.8065 2.26
Resource use, fossils Abiotic resource depletion fossil fuels (ADP-fossil) MJ 1313 779.4 4597 2.57
Resource use, minerals and metals Abiotic resource depletion (ADP ultimate reserve) kg Sb eq 0.004456 0.001759 0.0146 2.86
Water use User deprivation potential (deprivation-weighted water consumption) m3 world eq deprived 121.3 -2.602e+04 1.669e+04 —

Climate change 86.48 kg CO2 eq per m2. Main contributors: Photovoltaic cell, single-Si, at regional storage 67 %; Solar glass, low-iron, at regional storage 11 %; Electricity, medium voltage, production ENTSO-E, at grid 4 %; Glass fibre reinforced plastic, polyamide, injection mouldin… 3 %; Ethylvinylacetate, foil, at plant 3 %; Polyvinylfluoride film, at plant 3 %.

Interpretation

Significant issues

Direct exchanges dominating climate change: Photovoltaic cell, single-Si, at regional storage 67 %; Solar glass, low-iron, at regional storage 11 %; Electricity, medium voltage, production ENTSO-E, at grid 4 %; Glass fibre reinforced plastic, polyamide, injection mouldin… 3 %; Ethylvinylacetate, foil, at plant 3 %; Polyvinylfluoride film, at plant 3 %. Most sensitive exchanges (Section 6.3): Photovoltaic cell, single-Si, at regional storage [RER] (-44.7 / +133.9 %); Solar glass, low-iron, at regional storage [RER] (-2.7 / +3.6 %); Photovoltaic panel factory [GLO] (-0.7 / +2.2 %).

Independent recalculation

Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026):

Category Graph Published Graph / published
Acidification 0.2994 0.3241 0.924
Climate change-Biogenic 0.5574 0.5574 1.000
Climate change-Fossil 85.89 85.89 1.000
Climate change-Land use and land use change 0.03308 0.03308 1.000
Climate change 86.48 86.48 1.000
EF-particulate Matter 2.821e-06 2.821e-06 1.000
Ecotoxicity, freshwater_inorganics 729.5 733.9 0.994
Ecotoxicity, freshwater_organics 9.008 6.486 1.389
Ecotoxicity, freshwater 738.5 739.8 0.998
Eutrophication marine 0.1577 0.1577 1.000
Eutrophication, freshwater 0.03516 0.03516 1.000
Eutrophication, terrestrial 0.7653 0.7888 0.970
Human toxicity, cancer_inorganics 1.844e-08 1.818e-08 1.014
Human toxicity, cancer_organics 2.905e-08 2.905e-08 1.000
Human toxicity, cancer 4.749e-08 4.723e-08 1.006
Human toxicity, non-cancer_inorganics 1.283e-06 1.272e-06 1.008
Human toxicity, non-cancer_organics 5.347e-08 5.335e-08 1.002
Human toxicity, non-cancer 1.336e-06 1.326e-06 1.008
Ionising radiation, human health 28.01 28.01 1.000
Land use 759.4 619.1 1.227
Ozone depletion 3.172e-06 3.172e-06 1.000
Photochemical ozone formation - human health 0.2581 0.2581 1.000
Resource use, fossils 1313 1313 1.000
Resource use, minerals and metals 0.004456 0.004392 1.015
Water use 121.3 108.2 1.121
Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like.
Also published by BAFU for this dataset: IPCC 2021 GWP100 86.46 kg CO2 eq; Ecological Scarcity
2021 total 1.725e+05 UBP.

Sensitivity check

One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.

Exchange Base Low / high Range Δ GWP100 (%) Δ other categories (max %)
Photovoltaic cell, single-Si, at regional storage [RER] 0.9354 m2 ×0.334 / ×2.99 lognormal, GSD² 3.06 -44.7 / +133.9 195.3 (Water use)
Solar glass, low-iron, at regional storage [RER] 8.812 kg ×0.757 / ×1.32 lognormal, GSD² 1.33 -2.7 / +3.6 10.4 (Acidification)
Photovoltaic panel factory [GLO] 4.000e-06 p ×0.334 / ×2.99 lognormal, GSD² 3.06 -0.7 / +2.2 18.1 (Land use)
Glass fibre reinforced plastic, polyamide, injection moulding, at plant [RER] 0.295 kg ×0.808 / ×1.24 lognormal, GSD² 1.24 -0.6 / +0.7 1.2 (EF-particulate Matter)
Ethylvinylacetate, foil, at plant [RER] 0.875 kg ×0.808 / ×1.24 lognormal, GSD² 1.24 -0.6 / +0.7 7.8 (Ecotoxicity, freshwater_organics)
Polyvinylfluoride film, at plant [US] 0.1119 kg ×0.808 / ×1.24 lognormal, GSD² 1.24 -0.5 / +0.6 0.9 (Climate change-Land use and land use change)
Tempering, flat glass [RER] 8.812 kg ×0.808 / ×1.24 lognormal, GSD² 1.24 -0.5 / +0.6 1.0 (EF-particulate Matter)
Transport, freight, lorry, fleet average [RER] 2.561 tkm ×0.484 / ×2.06 lognormal, GSD² 2.1 -0.3 / +0.6 6.0 (Climate change-Land use and land use change)
Electricity, medium voltage, production ENTSO-E, at grid [ENTSO-E] 13.97 kWh ×0.918 / ×1.09 lognormal, GSD² 1.09 -0.4 / +0.4 1.6 (Ionising radiation, human health)
Polyethylene terephthalate, granulate, amorphous, at plant [RER] 0.3456 kg ×0.808 / ×1.24 lognormal, GSD² 1.24 -0.2 / +0.3 0.9 (Ecotoxicity, freshwater_organics)
Transport, freight, rail [RER] 15.36 tkm ×0.484 / ×2.06 lognormal, GSD² 2.1 -0.2 / +0.3 1.8 (Human toxicity, non-cancer_organics)
Diode, unspecified, at plant [GLO] 0.002812 kg ×0.748 / ×1.34 lognormal, GSD² 1.34 -0.2 / +0.2 0.5 (Human toxicity, non-cancer_organics)
Corrugated board, mixed fibre, single wall, at plant [RER] 0.7625 kg ×0.808 / ×1.24 lognormal, GSD² 1.24 -0.2 / +0.2 1.2 (Land use)
Silicone product, at plant [RER] 0.1219 kg ×0.808 / ×1.24 lognormal, GSD² 1.24 -0.1 / +0.1 1.5 (Ozone depletion)
EUR-flat pallet [RER] 0.05 p ×0.748 / ×1.34 lognormal, GSD² 1.34 -0.1 / +0.1 7.4 (Land use)

Uncertainty analysis

Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.

Comparison with other data

Source Scope Value This dataset Ratio Note
bafu Photovoltaic laminate, single-Si, at plant [US] 91.62 kg CO2 eq 86.48 0.94 same dataset name, other location
bafu Photovoltaic laminate, single-Si, at plant [APAC] 93.58 kg CO2 eq 86.48 0.92 same dataset name, other location
bafu Photovoltaic laminate, single-Si, at plant [CN] 99.07 kg CO2 eq 86.48 0.87 same dataset name, other location

Conclusions and limitations

GWP100 86.48 kg CO2 eq per m2 (95 % interval 47.47–303.1). Dominant contributors: Photovoltaic cell, single-Si, at regional storage 67 %; Solar glass, low-iron, at regional storage 11 %; Electricity, medium voltage, production ENTSO-E, at grid 4 %; Glass fibre reinforced plastic, polyamide, injection mouldin… 3 %; Ethylvinylacetate, foil, at plant 3 %; Polyvinylfluoride film, at plant 3 %. Most sensitive: Photovoltaic cell, single-Si, at regional storage [RER] (-44.7 / +133.9 %); Solar glass, low-iron, at regional storage [RER] (-2.7 / +3.6 %); Photovoltaic panel factory [GLO] (-0.7 / +2.2 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.

Final control

Item Status Detail
reference flow PASS production amount 1.0 m2
closure: sum of direct contributions = dataset score (all 25 categories) PASS largest relative gap 4.5e-16
independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) PASS graph / published = 1; categories within ±5 %: 21/25
every technosphere input of the EcoSpold delivery is in the graph PASS all present (bafu_links_check.py)
uncertainty declared on the direct exchanges PASS 36/36 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values
Monte Carlo 95 % interval contains the deterministic score PASS 86.48 in [47.47, 303.1]
time period declared PASS 1992-01/2020-12
geography is a known location code PASS RER
sources cited PASS 2 reference(s), of which 1 dataset source(s); 1 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them

References

  1. Frischknecht Rolf Stolz Philippe Krebs Luana de Wild-Scholten Mariska Sinha Parikhit (2020). Task 12 PV Sustainability - Life Cycle Inventories and Life Cycle Assessments of Photovoltaic Systems. Office of Scientific and Technical Information (OSTI). https://doi.org/10.2172/2308831 — published source; matched in Crossref (author, year ±1, title overlap)
  2. Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — database; dataset citation
  3. International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva.
  4. Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. (tdc-doc method reference; title, version and year to verify against the user's copy)
  5. European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra.
  6. Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236

Annex — licence and terms of use

BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.


To suggest a correction or a dataset that does not exist yet, use Propose a dataset.