Table of Contents

Carbon dioxide, captured from atmosphere, with adsorbent-based direct air capture system, operated with HP, 100kt CO2 — CH

Dataset documentation and final control (tdc-doc, imported mode)
Open this dataset in OpenData

Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Carbon dioxide, captured from atmosphere, with adsorbent-based direct air capture system, operated with HP, 100kt CO2 [CH], per 1 kg. EF v3.1 climate change 0.171 kg CO2 eq (Monte Carlo 95 % interval 0.1502–0.2488). Main contributors: Heat, at heat pump, air-water, 50kW, CH electricity, in old … 42 %; Electricity, low voltage, at grid 28 %; Amine-based silica production, for sorbent-based direct air … 16 %; Carbon dioxide compression, transport and storage 7 %; Treatment of direct air capture system, sorbent-based, 100kt… 4 %; Direct air capture system, sorbent-based, 100ktCO2 3 %. Status: final control passed.
Item Value
Dataset name Carbon dioxide, captured from atmosphere, with adsorbent-based direct air capture system, operated with HP, 100kt CO2
Dataset UUID / graph id bf3edfd6-d2bc-3885-8acb-5c718d43ae2d / activity:carbon_dioxide_captured_from_atmosphere_with_adsorbent_based_direct_air_capture_system_operated_with_hp_100kt_co2__ch
Reference product, unit Carbon dioxide, captured from atmosphere, with adsorbent-based direct air capture system, operated with HP, 100kt CO2, 1 kg
Location CH
Time period 2024-01/2024-01
Category chemicals / gases\transformation
Source database BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1
Publisher Swiss Federal Office for the Environment (FOEN/BAFU)
Background database BAFU 2026 v1 (graph bafuquery-db)
LCIA method EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix)
Status final control passed
Documented by tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17

Introduction

Direct Air Capture (DAC) of CO2 through temperature-vacuum swing adsorption. This DAC process uses adsorbents to capture CO2 from the air and separates it through vacuum and low-temperature heating. Climeworks provides data from its commercial DAC plants, which consist of multiple CO2 collectors and heat exchangers, capturing and releasing CO2 in cyclic operations. The solid sorbent used here is Amine on Silica. It can be regenerated at low temperatures (80-120C). For the sorbent system, the LCI data are collected from the work of Deutz and Bardow based on the Climeworks system. The LCI data represent a plant with an annual capacity of 100 kt CO2/year and a lifetime of 20 years. Source: Deutz, S., Bardow, A. Life-cycle assessment of an industrial direct air capture process based on temperature-vacuum swing adsorption. Nat Energy 6, (2021). https://doi.org/10.1038/s41560-020-00771-9. Assumes “future” electricity consumption of 0.5 kWh/kg CO2 captured as per Deutz and Bardow, 2021. Current electricity consumption is closer to 0.7 kWh/kg CO2 captured. Future heat demand is 5.4 MJ/kg CO2 captured, as per Deutz and Bardow, 2021. The current demand is closer to 11.9. Future MEA consumption is 3 kg/t CO2 captured. Current consumption is closer to 7 kg/t CO2 captured, as per Deutz and Bardow, 2021. UUID: bf3edfd6-d2bc-3885-8acb-5c718d43ae2d

This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.

Goal and scope

Function, functional unit and reference flow

Reference flow: 1 kg of Carbon dioxide, captured from atmosphere, with adsorbent-based direct air capture system, operated with HP, 100kt CO2 (CH). All results are given per unit of the reference flow.

System boundary

—

Technology

—

Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).

LCIA method

EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.

Life cycle inventory

Inventory table

Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).

Exchange Type Location / compartment Amount Unit Uncertainty Pedigree GWP share (%) Notes
Heat, at heat pump, air-water, 50kW, CH electricity, in old building technosphere CH 5.4 MJ lognormal, GSD² 1.38 — 42.1 ████████
Electricity, low voltage, at grid technosphere CH 0.5 kWh lognormal, GSD² 1.38 — 28.4 ██████
Amine-based silica production, for sorbent-based direct air capture system technosphere RER 0.003 kg lognormal, GSD² 1.38 — 16.2 ███
Carbon dioxide compression, transport and storage technosphere CH 1 kg none declared: tdc-doc default ±50 % — 6.6 █
Treatment of direct air capture system, sorbent-based, 100ktCO2 technosphere RER 5.0000e-10 p lognormal, GSD² 3.14 — 3.7 █
Direct air capture system, sorbent-based, 100ktCO2 technosphere RER 5.0000e-10 p lognormal, GSD² 3.14 — 3.0 █ placed: containing (wanted CH)
Transport, freight, lorry, 16t-32t gross weight, fleet average technosphere CH 1.5000e-04 tkm lognormal, GSD² 2.21 — 0.0 ·
Transport, freight, rail, electricity with shunting technosphere CH 0.0018 tkm lognormal, GSD² 2.21 — 0.0 ·
Carbon Dioxide (biogenic) elementary natural resource 1 kg lognormal, GSD² 1.38 — 0.0 ·
Carbon Dioxide (biogenic) elementary air/Ground level / Urban (>1000 people/s… 0.021 kg lognormal, GSD² 1.38 — 0.0 ·

Data quality

0 of 10 direct exchanges carry a declared pedigree, 9 carry a distribution.

Field As declared by the publisher
Data generator / entry / validation data generator: Romain Sacchi (PSI); data entry: Romain Sacchi (PSI); validation (proof reading): Pierryves Padey (FOEN)
sampling procedure Sampling procedure: Literature data
validation details Proof reading validation: Passed, Other validation: none, Validator: Pierryves Padey, Telephone: +41 58 462 93 11, E-mail: pierryves.padey@bafu.admin.ch, Company: Federal Office for the Environment, Country: CH

Data gaps, proxies and assumptions

Item Class Value used Reason Effect
1 exchange(s) without declared uncertainty uncertainty fixed in the Monte Carlo the publisher declares no distribution ±50 % in the sensitivity check (Section 6.3)

Life cycle impact assessment (EF v3.1)

Per 1 kg. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.

Impact category Indicator Unit Result 2.5 % 97.5 % GSD²
Acidification Accumulated Exceedance (AE) mol H+ eq 4.282e-04 3.720e-04 7.183e-04 1.39
Climate change-Biogenic Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.003195 0.002282 0.005381 1.55
Climate change-Fossil Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.1674 0.1477 0.2451 1.31
Climate change-Land use and land use change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 3.636e-04 2.452e-04 5.889e-04 1.56
Climate change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.171 0.1502 0.2488 1.31
EF-particulate Matter Impact on human health disease incidence 7.232e-09 6.079e-09 1.273e-08 1.44
Ecotoxicity, freshwater_inorganics Comparative Toxic Unit for ecosystems (CTUe) CTUe 0.6162 0.5697 1.311 1.52
Ecotoxicity, freshwater_organics Comparative Toxic Unit for ecosystems (CTUe) CTUe 0.009895 0.009242 0.02544 1.7
Ecotoxicity, freshwater Comparative Toxic Unit for ecosystems (CTUe) CTUe 0.6261 0.5807 1.331 1.52
Eutrophication marine Fraction of nutrients reaching marine end compartment (N) kg N eq 1.389e-04 1.271e-04 2.094e-04 1.3
Eutrophication, freshwater Fraction of nutrients reaching freshwater end compartment (P) kg P eq 1.280e-04 7.787e-05 5.547e-04 2.75
Eutrophication, terrestrial Accumulated Exceedance (AE) mol N eq 0.00137 0.001193 0.002129 1.33
Human toxicity, cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 3.856e-11 3.769e-11 1.117e-10 1.72
Human toxicity, cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 6.316e-11 4.932e-11 1.048e-10 1.46
Human toxicity, cancer Comparative Toxic Unit for human (CTUh) CTUh 1.017e-10 9.577e-11 1.997e-10 1.46
Human toxicity, non-cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 2.410e-09 2.212e-09 8.106e-09 1.93
Human toxicity, non-cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 1.585e-10 1.105e-10 4.409e-10 1.97
Human toxicity, non-cancer Comparative Toxic Unit for human (CTUh) CTUh 2.569e-09 2.364e-09 8.357e-09 1.9
Ionising radiation, human health Human exposure efficiency relative to U235 kBq U235 eq 0.8071 0.2831 4.419 4.22
Land use Soil quality index pt (soil quality index) 2.144 1.491 3.625 1.58
Ozone depletion Ozone Depletion Potential (ODP) kg CFC-11 eq 2.619e-08 1.714e-08 6.049e-08 1.89
Photochemical ozone formation - human health Tropospheric ozone concentration increase kg NMVOC eq 3.317e-04 3.041e-04 5.929e-04 1.4
Resource use, fossils Abiotic resource depletion fossil fuels (ADP-fossil) MJ 8.507 6.721 12.8 1.4
Resource use, minerals and metals Abiotic resource depletion (ADP ultimate reserve) kg Sb eq 2.183e-06 1.447e-06 5.820e-06 2.1
Water use User deprivation potential (deprivation-weighted water consumption) m3 world eq deprived 0.07305 -270.4 138.1 —

Climate change 0.171 kg CO2 eq per kg. Main contributors: Heat, at heat pump, air-water, 50kW, CH electricity, in old … 42 %; Electricity, low voltage, at grid 28 %; Amine-based silica production, for sorbent-based direct air … 16 %; Carbon dioxide compression, transport and storage 7 %; Treatment of direct air capture system, sorbent-based, 100kt… 4 %; Direct air capture system, sorbent-based, 100ktCO2 3 %.

Interpretation

Significant issues

Direct exchanges dominating climate change: Heat, at heat pump, air-water, 50kW, CH electricity, in old … 42 %; Electricity, low voltage, at grid 28 %; Amine-based silica production, for sorbent-based direct air … 16 %; Carbon dioxide compression, transport and storage 7 %; Treatment of direct air capture system, sorbent-based, 100kt… 4 %; Direct air capture system, sorbent-based, 100ktCO2 3 %. Most sensitive exchanges (Section 6.3): Heat, at heat pump, air-water, 50kW, CH electricity, in old building [CH] (-11.3 / +15.5 %); Electricity, low voltage, at grid [CH] (-7.6 / +10.4 %); Amine-based silica production, for sorbent-based direct air capture system [RER] (-4.4 / +6.0 %).

Independent recalculation

Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026):

Category Graph Published Graph / published
Acidification 4.282e-04 5.240e-04 0.817
Climate change-Biogenic 0.003195 0.003195 1.000
Climate change-Fossil 0.1674 0.1674 1.000
Climate change-Land use and land use change 3.636e-04 3.636e-04 1.000
Climate change 0.171 0.171 1.000
EF-particulate Matter 7.232e-09 7.232e-09 1.000
Ecotoxicity, freshwater_inorganics 0.6162 0.6434 0.958
Ecotoxicity, freshwater_organics 0.009895 0.01013 0.976
Ecotoxicity, freshwater 0.6261 0.6531 0.959
Eutrophication marine 1.389e-04 1.386e-04 1.003
Eutrophication, freshwater 1.280e-04 1.280e-04 1.000
Eutrophication, terrestrial 0.00137 0.001313 1.044
Human toxicity, cancer_inorganics 3.856e-11 3.704e-11 1.041
Human toxicity, cancer_organics 6.316e-11 6.316e-11 1.000
Human toxicity, cancer 1.017e-10 1.002e-10 1.015
Human toxicity, non-cancer_inorganics 2.410e-09 2.335e-09 1.032
Human toxicity, non-cancer_organics 1.585e-10 1.586e-10 1.000
Human toxicity, non-cancer 2.569e-09 2.494e-09 1.030
Ionising radiation, human health 0.8071 0.8071 1.000
Land use 2.144 1.702 1.260
Ozone depletion 2.619e-08 2.619e-08 1.000
Photochemical ozone formation - human health 3.317e-04 3.317e-04 1.000
Resource use, fossils 8.507 8.507 1.000
Resource use, minerals and metals 2.183e-06 2.105e-06 1.037
Water use 0.07305 0.08101 0.902
Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like.
Also published by BAFU for this dataset: IPCC 2021 GWP100 0.1709 kg CO2 eq; Ecological Scarcity
2021 total 641.9 UBP.

Sensitivity check

One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.

Exchange Base Low / high Range Δ GWP100 (%) Δ other categories (max %)
Heat, at heat pump, air-water, 50kW, CH electricity, in old building [CH] 5.4 MJ ×0.731 / ×1.37 lognormal, GSD² 1.38 -11.3 / +15.5 26.1 (Ozone depletion)
Electricity, low voltage, at grid [CH] 0.5 kWh ×0.731 / ×1.37 lognormal, GSD² 1.38 -7.6 / +10.4 16.4 (Ionising radiation, human health)
Amine-based silica production, for sorbent-based direct air capture system [RER] 0.003 kg ×0.731 / ×1.37 lognormal, GSD² 1.38 -4.4 / +6.0 18.0 (Eutrophication, terrestrial)
Treatment of direct air capture system, sorbent-based, 100ktCO2 [RER] 5.000e-10 p ×0.326 / ×3.07 lognormal, GSD² 3.14 -2.5 / +7.6 15.3 (Ecotoxicity, freshwater_inorganics)
Direct air capture system, sorbent-based, 100ktCO2 [RER] 5.000e-10 p ×0.326 / ×3.07 lognormal, GSD² 3.14 -2.0 / +6.2 21.6 (Human toxicity, cancer_inorganics)
Carbon dioxide compression, transport and storage [CH] 1 kg ×0.5 / ×1.5 none declared: tdc-doc default ±50 % -3.3 / +3.3 5.0 (Climate change-Land use and land use change)
Transport, freight, lorry, 16t-32t gross weight, fleet average [CH] 1.500e-04 tkm ×0.46 / ×2.17 lognormal, GSD² 2.21 -0.0 / +0.0 0.1 (Ecotoxicity, freshwater_organics)
Transport, freight, rail, electricity with shunting [CH] 0.0018 tkm ×0.46 / ×2.17 lognormal, GSD² 2.21 -0.0 / +0.0 0.0 (Land use)

Uncertainty analysis

Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.

Comparison with other data

No other location of this dataset in the graph.

Conclusions and limitations

GWP100 0.171 kg CO2 eq per kg (95 % interval 0.1502–0.2488). Dominant contributors: Heat, at heat pump, air-water, 50kW, CH electricity, in old … 42 %; Electricity, low voltage, at grid 28 %; Amine-based silica production, for sorbent-based direct air … 16 %; Carbon dioxide compression, transport and storage 7 %; Treatment of direct air capture system, sorbent-based, 100kt… 4 %; Direct air capture system, sorbent-based, 100ktCO2 3 %. Most sensitive: Heat, at heat pump, air-water, 50kW, CH electricity, in old building [CH] (-11.3 / +15.5 %); Electricity, low voltage, at grid [CH] (-7.6 / +10.4 %); Amine-based silica production, for sorbent-based direct air capture system [RER] (-4.4 / +6.0 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.

Final control

Item Status Detail
reference flow PASS production amount 1.0 kg
closure: sum of direct contributions = dataset score (all 25 categories) PASS largest relative gap 4.1e-16
independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) PASS graph / published = 1; categories within ±5 %: 22/25
every technosphere input of the EcoSpold delivery is in the graph PASS all present (bafu_links_check.py)
uncertainty declared on the direct exchanges PASS 9/10 exchanges carry a distribution (90 %); the others enter the Monte Carlo as fixed values
Monte Carlo 95 % interval contains the deterministic score PASS 0.171 in [0.1502, 0.2488]
time period declared PASS 2024-01/2024-01
geography is a known location code PASS CH
sources cited PASS 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them

References

  1. Report — source; as declared by BAFU (not found in OpenAlex/Crossref)
  2. Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — database; dataset citation
  3. International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva.
  4. Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. (tdc-doc method reference; title, version and year to verify against the user's copy)
  5. European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra.
  6. Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236

Annex — licence and terms of use

BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.


To suggest a correction or a dataset that does not exist yet, use Propose a dataset.