Table of Contents

Solar system, 30 m2 Cu flat plate collector, on flat roof, hot water — CH

Dataset documentation and final control (tdc-doc, imported mode)
Open this dataset in OpenData

Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Solar system, 30 m2 Cu flat plate collector, on flat roof, hot water [CH], per 1 p. EF v3.1 climate change 4223 kg CO2 eq (Monte Carlo 95 % interval 2611–1.295e+04). Main contributors: Flat plate collector, copper absorber, at plant 42 %; Heat storage 2000l, at plant 20 %; Transport, freight, lorry, 3.5t gross weight, fleet average 17 %; Steel, low-alloyed, at plant 6 %; Concrete, normal, at plant 3 %; Propylene glycol, liquid, at plant 2 %. Status: final control passed.
Item Value
Dataset name Solar system, 30 m2 Cu flat plate collector, on flat roof, hot water
Dataset UUID / graph id bf87aba3-fff4-364f-97f1-d80c66747ef2 / activity:solar_system_30_m2_cu_flat_plate_collector_on_flat_roof_hot_water__ch
Reference product, unit Solar system, 30 m2 Cu flat plate collector, on flat roof, hot water, 1 p
Location CH
Time period 2000-01/2010-12
Category heat / solar\infrastructure
Source database BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1
Publisher Swiss Federal Office for the Environment (FOEN/BAFU)
Background database BAFU 2026 v1 (graph bafuquery-db)
LCIA method EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix)
Status final control passed
Documented by tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17

Introduction

Solar system with a flat plate collector on a multiple family dwelling for hot water. 25 years life time, 65 m pipe length and 1500 l heat storage. ; UUID: bf87aba3-fff4-364f-97f1-d80c66747ef2

This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.

Goal and scope

Function, functional unit and reference flow

Reference flow: 1 p of Solar system, 30 m2 Cu flat plate collector, on flat roof, hot water (CH). All results are given per unit of the reference flow.

System boundary

Production and disposal of a complete solar system (excluding auxiliary heating). Including different components, heat exchange fluid, warm water pipes, transports of parts to CH, and delivery with a van.

Technology

Solar collector system for hot water installed on the roof of a house.

Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).

LCIA method

EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.

Life cycle inventory

Inventory table

Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).

Exchange Type Location / compartment Amount Unit Uncertainty Pedigree GWP share (%) Notes
Flat plate collector, copper absorber, at plant technosphere CH 30 m2 lognormal, GSD² 4.81 — 42.0 ████████
Heat storage 2000l, at plant technosphere CH 0.91848 p lognormal, GSD² 4.81 — 19.7 ████
Transport, freight, lorry, 3.5t gross weight, fleet average technosphere CH 660 tkm lognormal, GSD² 3.79 (3,5,3,1,1,5) 16.9 ███
Steel, low-alloyed, at plant technosphere RER 120 kg lognormal, GSD² 3.07 — 6.1 █
Concrete, normal, at plant technosphere CH 0.63025 m3 lognormal, GSD² 3.07 — 3.4 █
Propylene glycol, liquid, at plant technosphere RER 33.381 kg lognormal, GSD² 3.07 — 2.3 ·
Chromium steel 18/8, at plant technosphere RER 18.92 kg lognormal, GSD² 3.07 — 2.0 ·
Treatment, heat carrier liquid, 40% C3H8O2, to wastewater treatment, class 2 technosphere CH 0.090256 m3 lognormal, GSD² 3.07 — 1.9 ·
Expansion vessel 80l, at plant technosphere CH 1.75 p lognormal, GSD² 4.81 — 1.9 ·
Tube insulation, elastomere, at plant technosphere DE 14.703 kg lognormal, GSD² 3.07 — 1.6 ·
Disposal, plastics, mixture, 15.3% water, to municipal incineration technosphere CH 16.091 kg lognormal, GSD² 3.07 — 0.9 ·
Zinc coating, coils technosphere RER 7.68 m2 lognormal, GSD² 3.07 — 0.7 ·
Pump 40W, at plant technosphere CH 1.9444 p lognormal, GSD² 4.81 — 0.3 ·
Drawing of pipes, steel technosphere RER 18.92 kg lognormal, GSD² 3.12 — 0.2 ·
Packaging film, LDPE, at plant technosphere RER 1.3886 kg lognormal, GSD² 3.07 — 0.1 ·
Transport, freight, rail technosphere RER 147.16 tkm lognormal, GSD² 3.76 — 0.1 ·
Transport, freight, lorry, 16t-32t gross weight, fleet average technosphere CH 12.263 tkm lognormal, GSD² 3.76 — 0.1 ·
Water, completely softened, at plant technosphere RER 56.875 kg lognormal, GSD² 3.07 — 0.0 ·

Data quality

1 of 18 direct exchanges carry a declared pedigree, 18 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 3.0 · completeness 5.0 · temporal 3.0 · geographical 1.0 · technological 1.0 · sample size 5.0.

Field As declared by the publisher
Data generator / entry / validation data generator: Matthias Stucki (ZHAW); data entry: Matthias Stucki (ZHAW); validation (proof reading): Niels Jungbluth (ESU)
extrapolations none
sampling procedure Own simulation.
production volume 10'433 systems with flat plate collectors were sold in 2008. 27.4% of the area is installed on multiple dwellings for hot water.
uncertainty adjustments none
validation details Proof reading validation: 17.12.2010; Other validation: \Server\E\ESU-Docs\Projekte laufend\352 Sonnenkollektoranlagen\Berechnung[neueingabe-Kollektoren-2.2+V1.0.xlsx]X-Process;
time period comment Time of simulation.

Data gaps, proxies and assumptions

None recorded.

Life cycle impact assessment (EF v3.1)

Per 1 p. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.

Impact category Indicator Unit Result 2.5 % 97.5 % GSD²
Acidification Accumulated Exceedance (AE) mol H+ eq 32.93 15.23 141.3 3
Climate change-Biogenic Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 10.26 5.807 44.32 2.79
Climate change-Fossil Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 4210 2603 1.29e+04 2.25
Climate change-Land use and land use change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 2.39 1.137 9.908 3
Climate change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 4223 2611 1.295e+04 2.25
EF-particulate Matter Impact on human health disease incidence 2.608e-04 1.718e-04 0.001329 2.95
Ecotoxicity, freshwater_inorganics Comparative Toxic Unit for ecosystems (CTUe) CTUe 5.31e+04 2.829e+04 2.108e+05 2.79
Ecotoxicity, freshwater_organics Comparative Toxic Unit for ecosystems (CTUe) CTUe 724.8 476 2605 2.55
Ecotoxicity, freshwater Comparative Toxic Unit for ecosystems (CTUe) CTUe 5.383e+04 2.882e+04 2.164e+05 2.77
Eutrophication marine Fraction of nutrients reaching marine end compartment (N) kg N eq 5.061 2.897 17.86 2.53
Eutrophication, freshwater Fraction of nutrients reaching freshwater end compartment (P) kg P eq 5.73 1.965 51.65 5.43
Eutrophication, terrestrial Accumulated Exceedance (AE) mol N eq 62.46 37.92 208.2 2.35
Human toxicity, cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 3.463e-06 1.984e-06 1.970e-05 3.24
Human toxicity, cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 1.486e-06 1.016e-06 5.221e-06 2.42
Human toxicity, cancer Comparative Toxic Unit for human (CTUh) CTUh 4.949e-06 3.169e-06 2.419e-05 2.9
Human toxicity, non-cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 2.331e-04 1.204e-04 0.001385 3.59
Human toxicity, non-cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 1.645e-05 5.090e-06 7.930e-05 4.01
Human toxicity, non-cancer Comparative Toxic Unit for human (CTUh) CTUh 2.495e-04 1.260e-04 0.001495 3.58
Ionising radiation, human health Human exposure efficiency relative to U235 kBq U235 eq 1208 368.5 1.004e+04 5.46
Land use Soil quality index pt (soil quality index) 4.285e+04 2.449e+04 1.462e+05 2.51
Ozone depletion Ozone Depletion Potential (ODP) kg CFC-11 eq 2.753e-04 1.685e-04 8.636e-04 2.38
Photochemical ozone formation - human health Tropospheric ozone concentration increase kg NMVOC eq 18.21 10.62 61.5 2.44
Resource use, fossils Abiotic resource depletion fossil fuels (ADP-fossil) MJ 5.542e+04 3.379e+04 1.875e+05 2.36
Resource use, minerals and metals Abiotic resource depletion (ADP ultimate reserve) kg Sb eq 0.1591 0.05212 0.7436 —
Water use User deprivation potential (deprivation-weighted water consumption) m3 world eq deprived 336.2 -1.871e+06 1.086e+06 —

Climate change 4223 kg CO2 eq per p. Main contributors: Flat plate collector, copper absorber, at plant 42 %; Heat storage 2000l, at plant 20 %; Transport, freight, lorry, 3.5t gross weight, fleet average 17 %; Steel, low-alloyed, at plant 6 %; Concrete, normal, at plant 3 %; Propylene glycol, liquid, at plant 2 %.

Interpretation

Significant issues

Direct exchanges dominating climate change: Flat plate collector, copper absorber, at plant 42 %; Heat storage 2000l, at plant 20 %; Transport, freight, lorry, 3.5t gross weight, fleet average 17 %; Steel, low-alloyed, at plant 6 %; Concrete, normal, at plant 3 %; Propylene glycol, liquid, at plant 2 %. Most sensitive exchanges (Section 6.3): Flat plate collector, copper absorber, at plant [CH] (-33.0 / +153.6 %); Heat storage 2000l, at plant [CH] (-15.4 / +72.0 %); Transport, freight, lorry, 3.5t gross weight, fleet average [CH] (-12.3 / +45.3 %).

Independent recalculation

Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026):

Category Graph Published Graph / published
Acidification 32.93 35.46 0.928
Climate change-Biogenic 10.26 10.26 1.000
Climate change-Fossil 4210 4210 1.000
Climate change-Land use and land use change 2.39 2.39 1.000
Climate change 4223 4223 1.000
EF-particulate Matter 2.608e-04 2.608e-04 1.000
Ecotoxicity, freshwater_inorganics 5.31e+04 5.357e+04 0.991
Ecotoxicity, freshwater_organics 724.8 722.2 1.004
Ecotoxicity, freshwater 5.383e+04 5.429e+04 0.992
Eutrophication marine 5.061 5.061 1.000
Eutrophication, freshwater 5.73 5.73 1.000
Eutrophication, terrestrial 62.46 65.89 0.948
Human toxicity, cancer_inorganics 3.463e-06 3.448e-06 1.004
Human toxicity, cancer_organics 1.486e-06 1.486e-06 1.000
Human toxicity, cancer 4.949e-06 4.934e-06 1.003
Human toxicity, non-cancer_inorganics 2.331e-04 2.324e-04 1.003
Human toxicity, non-cancer_organics 1.645e-05 1.645e-05 1.000
Human toxicity, non-cancer 2.495e-04 2.489e-04 1.003
Ionising radiation, human health 1208 1208 1.000
Land use 4.285e+04 3.022e+04 1.418
Ozone depletion 2.753e-04 2.753e-04 1.000
Photochemical ozone formation - human health 18.21 18.21 1.000
Resource use, fossils 5.542e+04 5.543e+04 1.000
Resource use, minerals and metals 0.1591 0.1553 1.024
Water use 336.2 382.3 0.879
Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like.
Also published by BAFU for this dataset: IPCC 2021 GWP100 4222 kg CO2 eq; Ecological Scarcity
2021 total 1.146e+07 UBP.

Sensitivity check

One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.

Exchange Base Low / high Range Δ GWP100 (%) Δ other categories (max %)
Flat plate collector, copper absorber, at plant [CH] 30 m2 ×0.215 / ×4.66 lognormal, GSD² 4.81 -33.0 / +153.6 328.6 (Human toxicity, non-cancer_organics)
Heat storage 2000l, at plant [CH] 0.9185 p ×0.215 / ×4.66 lognormal, GSD² 4.81 -15.4 / +72.0 123.2 (Land use)
Transport, freight, lorry, 3.5t gross weight, fleet average [CH] 660 tkm ×0.271 / ×3.69 lognormal, GSD² 3.79 -12.3 / +45.3 107.3 (Ozone depletion)
Steel, low-alloyed, at plant [RER] 120 kg ×0.333 / ×3.01 lognormal, GSD² 3.07 -4.1 / +12.2 14.5 (Human toxicity, cancer_organics)
Concrete, normal, at plant [CH] 0.6302 m3 ×0.333 / ×3.01 lognormal, GSD² 3.07 -2.3 / +6.8 6.9 (Climate change-Fossil)
Expansion vessel 80l, at plant [CH] 1.75 p ×0.215 / ×4.66 lognormal, GSD² 4.81 -1.5 / +6.8 9.3 (Ionising radiation, human health)
Propylene glycol, liquid, at plant [RER] 33.38 kg ×0.333 / ×3.01 lognormal, GSD² 3.07 -1.6 / +4.7 79.7 (Ecotoxicity, freshwater_inorganics)
Chromium steel 18/8, at plant [RER] 18.92 kg ×0.333 / ×3.01 lognormal, GSD² 3.07 -1.3 / +4.0 6.2 (Human toxicity, cancer_inorganics)
Treatment, heat carrier liquid, 40% C3H8O2, to wastewater treatment, class 2 [CH] 0.09026 m3 ×0.333 / ×3.01 lognormal, GSD² 3.07 -1.3 / +3.8 3.8 (Climate change-Fossil)
Tube insulation, elastomere, at plant [DE] 14.7 kg ×0.333 / ×3.01 lognormal, GSD² 3.07 -1.0 / +3.1 7.4 (Climate change-Land use and land use change)
Disposal, plastics, mixture, 15.3% water, to municipal incineration [CH] 16.09 kg ×0.333 / ×3.01 lognormal, GSD² 3.07 -0.6 / +1.8 1.8 (Climate change-Fossil)
Zinc coating, coils [RER] 7.68 m2 ×0.333 / ×3.01 lognormal, GSD² 3.07 -0.5 / +1.5 37.6 (Eutrophication, terrestrial)
Pump 40W, at plant [CH] 1.944 p ×0.215 / ×4.66 lognormal, GSD² 4.81 -0.3 / +1.2 3.2 (Human toxicity, non-cancer_inorganics)
Drawing of pipes, steel [RER] 18.92 kg ×0.328 / ×3.05 lognormal, GSD² 3.12 -0.1 / +0.4 2.9 (Climate change-Land use and land use change)
Packaging film, LDPE, at plant [RER] 1.389 kg ×0.333 / ×3.01 lognormal, GSD² 3.07 -0.1 / +0.2 8.7 (Human toxicity, cancer_organics)

Uncertainty analysis

Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.

Comparison with other data

No other location of this dataset in the graph.

Conclusions and limitations

GWP100 4223 kg CO2 eq per p (95 % interval 2611–1.295e+04). Dominant contributors: Flat plate collector, copper absorber, at plant 42 %; Heat storage 2000l, at plant 20 %; Transport, freight, lorry, 3.5t gross weight, fleet average 17 %; Steel, low-alloyed, at plant 6 %; Concrete, normal, at plant 3 %; Propylene glycol, liquid, at plant 2 %. Most sensitive: Flat plate collector, copper absorber, at plant [CH] (-33.0 / +153.6 %); Heat storage 2000l, at plant [CH] (-15.4 / +72.0 %); Transport, freight, lorry, 3.5t gross weight, fleet average [CH] (-12.3 / +45.3 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.

Final control

Item Status Detail
reference flow PASS production amount 1.0 p
closure: sum of direct contributions = dataset score (all 25 categories) PASS largest relative gap 3.7e-16
independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) PASS graph / published = 1; categories within ±5 %: 21/25
every technosphere input of the EcoSpold delivery is in the graph PASS all present (bafu_links_check.py)
uncertainty declared on the direct exchanges PASS 18/18 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values
Monte Carlo 95 % interval contains the deterministic score PASS 4223 in [2611, 1.295e+04]
time period declared PASS 2000-01/2010-12
geography is a known location code PASS CH
sources cited PASS 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them

References

  1. Stucki M., Jungbluth N. (2010) Update of the Life Cycle Inventories of Solar Collectors. Volume: 352. ESU-services Ltd.. Uster, CH. Type: Separate publication First author: Stucki M. Other authors: Jungbluth N. Year: 2010 Place of publication: Uster, CH Publisher: ESU-services Ltd. Volume No: 352 — published source; as declared by BAFU (not found in OpenAlex/Crossref)
  2. Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — database; dataset citation
  3. International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva.
  4. Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. (tdc-doc method reference; title, version and year to verify against the user's copy)
  5. European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra.
  6. Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236

Annex — licence and terms of use

BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.


To suggest a correction or a dataset that does not exist yet, use Propose a dataset.