Dataset documentation and final control (tdc-doc, imported mode)
Open this dataset in OpenData
Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset xxx Electricity mix, GO cancellations [CZ], per 1 kWh. EF v3.1 climate change 0.03114 kg CO2 eq (Monte Carlo 95 % interval 0.02421–0.06062). Main contributors: Electricity, at cogen 1MWth, wood chips, allocation exergy 85 %; Electricity, hydropower, at reservoir power plant, non alpin… 7 %; Electricity, hydropower, at run-of-river power plant 3 %; Electricity, hydropower, at reservoir power plant, alpine re… 2 %; Electricity, at wind farm 1 %; Electricity, production mix photovoltaic, at plant 1 %. Status: final control passed.
| Item | Value |
|---|---|
| Dataset name | xxx Electricity mix, GO cancellations |
| Dataset UUID / graph id | cfe36b54-f286-36a3-9117-a6c83d70ec5d / activity:xxx_electricity_mix_go_cancellations__cz |
| Reference product, unit | xxx Electricity mix, GO cancellations, 1 kWh |
| Location | CZ — undefined |
| Time period | 2018-01/2018-12 |
| Category | electricity / notMaintained |
| Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 |
| Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) |
| Background database | BAFU 2026 v1 (graph bafuquery-db) |
| LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) |
| Status | final control passed |
| Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 |
The location and technology of the production of the residual attributes have been for some technologies (biomass, solar, hydropower) adapted by the ENTSO-mix based on technologies, which is a rough estimation. Time period: Time of publications. Version: 1 Energy values: Undefined Local category: Elektrizität Local subcategory: Erzeugungsmix UVEK 2022 source file:726-Strommixe-EU_v0.8._X-GO cancellations 2018.xml UUID: cfe36b54-f286-36a3-9117-a6c83d70ec5d
This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.
Reference flow: 1 kWh of xxx Electricity mix, GO cancellations (CZ). All results are given per unit of the reference flow.
Included are the shares of cancelled GOs by technology in 2018. Not included are transformation, transport or distribution losses.
undefined
Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).
EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.
Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).
| Exchange | Type | Location / compartment | Amount | Unit | Uncertainty | Pedigree | GWP share (%) | Notes | |
|---|---|---|---|---|---|---|---|---|---|
| Electricity, at cogen 1MWth, wood chips, allocation exergy | technosphere | CH | 0.42235 | kWh | lognormal, GSD² 1.05 | — | 84.8 | █████████████████ | |
| Electricity, hydropower, at reservoir power plant, non alpine regions | technosphere | RER | 0.13503 | kWh | lognormal, GSD² 1.05 | — | 7.0 | █ | |
| Electricity, hydropower, at run-of-river power plant | technosphere | RER | 0.26212 | kWh | lognormal, GSD² 1.05 | — | 3.1 | █ | |
| Electricity, hydropower, at reservoir power plant, alpine region | technosphere | RER | 0.13503 | kWh | lognormal, GSD² 1.05 | — | 2.3 | · | |
| Electricity, at wind farm | technosphere | RER | 0.032127 | kWh | lognormal, GSD² 1.05 | — | 1.5 | · | |
| Electricity, production mix photovoltaic, at plant | technosphere | DE | 0.01333 | kWh | lognormal, GSD² 1.05 | — | 1.3 | · |
0 of 6 direct exchanges carry a declared pedigree, 6 carry a distribution.
| Field | As declared by the publisher |
|---|---|
| Data generator / entry / validation | data generator: Luana Krebs (TREEZE); data entry: Luana Krebs (TREEZE); validation (proof reading): Rolf Frischknecht (TREEZE) |
| extrapolations | |
| sampling procedure | |
| production volume | na |
| uncertainty adjustments | none |
| validation details | Proof reading validation: 10.02.2021; Other validation: G:\Projekte laufend\726 Umweltbilanz Strommix Schweiz 2018\EcoSpold[726-Strommixe-EU_v0.8.xlsx]X-Process; |
| time period comment | Time of publications. |
None recorded.
Per 1 kWh. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.
| Impact category | Indicator | Unit | Result | 2.5 % | 97.5 % | GSD² |
|---|---|---|---|---|---|---|
| Acidification | Accumulated Exceedance (AE) | mol H+ eq | 2.035e-04 | 1.624e-04 | 3.030e-04 | 1.39 |
| Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | 7.020e-04 | 5.179e-04 | 0.001063 | 1.44 |
| Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | 0.02878 | 0.02168 | 0.05772 | 1.67 |
| Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | 0.00166 | 8.602e-04 | 0.003489 | 2.02 |
| Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | 0.03114 | 0.02421 | 0.06062 | 1.61 |
| EF-particulate Matter | Impact on human health | disease incidence | 1.033e-08 | 4.826e-09 | 2.838e-08 | 2.47 |
| Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | 0.08136 | 0.06172 | 0.2531 | 2.05 |
| Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | 0.01014 | 0.007702 | 0.01747 | 1.52 |
| Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | 0.09149 | 0.07196 | 0.2632 | 1.96 |
| Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | 1.909e-04 | 1.346e-04 | 2.924e-04 | 1.5 |
| Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | 6.604e-06 | 4.496e-06 | 7.593e-05 | 3.94 |
| Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | 0.001986 | 0.00146 | 0.002871 | 1.42 |
| Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | 9.088e-12 | 7.963e-12 | 2.723e-11 | 1.88 |
| Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | 6.084e-10 | 3.333e-10 | 1.120e-09 | 1.84 |
| Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | 6.175e-10 | 3.455e-10 | 1.139e-09 | 1.82 |
| Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | 1.123e-09 | 8.194e-10 | 3.543e-09 | 2.15 |
| Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | 3.536e-11 | 2.564e-11 | 7.710e-11 | 1.74 |
| Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | 1.159e-09 | 8.592e-10 | 3.599e-09 | 2.12 |
| Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | 0.00322 | 0.001271 | 0.02237 | 4.56 |
| Land use | Soil quality index | pt (soil quality index) | 33.43 | 19.72 | 57.4 | 1.71 |
| Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | 7.074e-10 | 4.998e-10 | 1.605e-09 | 1.79 |
| Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | 6.182e-04 | 4.597e-04 | 9.286e-04 | 1.43 |
| Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | 0.3601 | 0.2592 | 0.7992 | 1.78 |
| Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | 1.587e-07 | 1.169e-07 | 4.115e-07 | 1.97 |
| Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | 0.001239 | -775.4 | 380.8 | — |
Climate change 0.03114 kg CO2 eq per kWh. Main contributors: Electricity, at cogen 1MWth, wood chips, allocation exergy 85 %; Electricity, hydropower, at reservoir power plant, non alpin… 7 %; Electricity, hydropower, at run-of-river power plant 3 %; Electricity, hydropower, at reservoir power plant, alpine re… 2 %; Electricity, at wind farm 1 %; Electricity, production mix photovoltaic, at plant 1 %.
Direct exchanges dominating climate change: Electricity, at cogen 1MWth, wood chips, allocation exergy 85 %; Electricity, hydropower, at reservoir power plant, non alpin… 7 %; Electricity, hydropower, at run-of-river power plant 3 %; Electricity, hydropower, at reservoir power plant, alpine re… 2 %; Electricity, at wind farm 1 %; Electricity, production mix photovoltaic, at plant 1 %. Most sensitive exchanges (Section 6.3): Electricity, at cogen 1MWth, wood chips, allocation exergy [CH] (-4.0 / +4.2 %); Electricity, hydropower, at reservoir power plant, non alpine regions [RER] (-0.3 / +0.3 %); Electricity, hydropower, at run-of-river power plant [RER] (-0.1 / +0.2 %).
Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh:
| Category | Graph | Published | Graph / published |
|---|---|---|---|
| Acidification | 2.035e-04 | 4.924e-04 | 0.413 |
| Climate change-Biogenic | 7.020e-04 | 7.020e-04 | 1.000 |
| Climate change-Fossil | 0.02878 | 0.02878 | 1.000 |
| Climate change-Land use and land use change | 0.00166 | 0.00166 | 1.000 |
| Climate change | 0.03114 | 0.03114 | 1.000 |
| EF-particulate Matter | 1.033e-08 | 1.033e-08 | 1.000 |
| Ecotoxicity, freshwater_inorganics | 0.08136 | 0.08207 | 0.991 |
| Ecotoxicity, freshwater_organics | 0.01014 | 0.01012 | 1.002 |
| Ecotoxicity, freshwater | 0.09149 | 0.09211 | 0.993 |
| Eutrophication marine | 1.909e-04 | 1.909e-04 | 1.000 |
| Eutrophication, freshwater | 6.604e-06 | 6.604e-06 | 1.000 |
| Eutrophication, terrestrial | 0.001986 | 0.002295 | 0.865 |
| Human toxicity, cancer_inorganics | 9.088e-12 | 9.044e-12 | 1.005 |
| Human toxicity, cancer_organics | 6.084e-10 | 6.084e-10 | 1.000 |
| Human toxicity, cancer | 6.175e-10 | 6.175e-10 | 1.000 |
| Human toxicity, non-cancer_inorganics | 1.123e-09 | 1.122e-09 | 1.001 |
| Human toxicity, non-cancer_organics | 3.536e-11 | 3.536e-11 | 1.000 |
| Human toxicity, non-cancer | 1.159e-09 | 1.157e-09 | 1.001 |
| Ionising radiation, human health | 0.00322 | 0.00322 | 1.000 |
| Land use | 33.43 | 26.73 | 1.251 |
| Ozone depletion | 7.074e-10 | 7.074e-10 | 1.000 |
| Photochemical ozone formation - human health | 6.182e-04 | 6.182e-04 | 1.000 |
| Resource use, fossils | 0.3601 | 0.3602 | 1.000 |
| Resource use, minerals and metals | 1.587e-07 | 1.557e-07 | 1.019 |
| Water use | 0.001239 | 0.001437 | 0.862 |
| Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | |||
| Also published by BAFU for this dataset: IPCC 2021 GWP100 0.03114 kg CO2 eq; Ecological Scarcity | |||
| 2021 total 120 UBP. |
One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.
| Exchange | Base | Low / high | Range | Δ GWP100 (%) | Δ other categories (max %) |
|---|---|---|---|---|---|
| Electricity, at cogen 1MWth, wood chips, allocation exergy [CH] | 0.4224 kWh | ×0.953 / ×1.05 | lognormal, GSD² 1.05 | -4.0 / +4.2 | 4.9 (Land use) |
| Electricity, hydropower, at reservoir power plant, non alpine regions [RER] | 0.135 kWh | ×0.953 / ×1.05 | lognormal, GSD² 1.05 | -0.3 / +0.3 | 4.3 (Climate change-Land use and land use change) |
| Electricity, hydropower, at run-of-river power plant [RER] | 0.2621 kWh | ×0.953 / ×1.05 | lognormal, GSD² 1.05 | -0.1 / +0.2 | 0.7 (Climate change-Biogenic) |
| Electricity, hydropower, at reservoir power plant, alpine region [RER] | 0.135 kWh | ×0.953 / ×1.05 | lognormal, GSD² 1.05 | -0.1 / +0.1 | 0.5 (Climate change-Land use and land use change) |
| Electricity, at wind farm [RER] | 0.03213 kWh | ×0.953 / ×1.05 | lognormal, GSD² 1.05 | -0.1 / +0.1 | 0.3 (Resource use, minerals and metals) |
| Electricity, production mix photovoltaic, at plant [DE] | 0.01333 kWh | ×0.953 / ×1.05 | lognormal, GSD² 1.05 | -0.1 / +0.1 | 1.0 (Resource use, minerals and metals) |
Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.
| Source | Scope | Value | This dataset | Ratio | Note |
|---|---|---|---|---|---|
| bafu | xxx Electricity mix, GO cancellations [CY] | 0.007271 kg CO2 eq | 0.03114 | 4.28 | same dataset name, other location |
| bafu | xxx Electricity mix, GO cancellations [MT] | 0.007271 kg CO2 eq | 0.03114 | 4.28 | same dataset name, other location |
| bafu | xxx Electricity mix, GO cancellations [PT] | 0.007289 kg CO2 eq | 0.03114 | 4.27 | same dataset name, other location |
| bafu | xxx Electricity mix, GO cancellations [GR] | 0.008748 kg CO2 eq | 0.03114 | 3.56 | same dataset name, other location |
| bafu | xxx Electricity mix, GO cancellations [NO] | 0.008867 kg CO2 eq | 0.03114 | 3.51 | same dataset name, other location |
| bafu | xxx Electricity mix, GO cancellations [BE] | 0.08314 kg CO2 eq | 0.03114 | 0.37 | same dataset name, other location |
| bafu | xxx Electricity mix, GO cancellations [ES] | 0.08837 kg CO2 eq | 0.03114 | 0.35 | same dataset name, other location |
| bafu | xxx Electricity mix, GO cancellations [AT] | 0.14 kg CO2 eq | 0.03114 | 0.22 | same dataset name, other location |
| bafu | xxx Electricity mix, GO cancellations [LU] | 0.1593 kg CO2 eq | 0.03114 | 0.20 | same dataset name, other location |
| bafu | xxx Electricity mix, GO cancellations [IE] | 0.2115 kg CO2 eq | 0.03114 | 0.15 | same dataset name, other location |
GWP100 0.03114 kg CO2 eq per kWh (95 % interval 0.02421–0.06062). Dominant contributors: Electricity, at cogen 1MWth, wood chips, allocation exergy 85 %; Electricity, hydropower, at reservoir power plant, non alpin… 7 %; Electricity, hydropower, at run-of-river power plant 3 %; Electricity, hydropower, at reservoir power plant, alpine re… 2 %; Electricity, at wind farm 1 %; Electricity, production mix photovoltaic, at plant 1 %. Most sensitive: Electricity, at cogen 1MWth, wood chips, allocation exergy [CH] (-4.0 / +4.2 %); Electricity, hydropower, at reservoir power plant, non alpine regions [RER] (-0.3 / +0.3 %); Electricity, hydropower, at run-of-river power plant [RER] (-0.1 / +0.2 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.
| Item | Status | Detail |
|---|---|---|
| reference flow | PASS | production amount 1.0 kWh |
| closure: sum of direct contributions = dataset score (all 25 categories) | PASS | largest relative gap 2.2e-16 |
| independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh (climate change) | PASS | graph / published = 1; categories within ±5 %: 21/25 |
| every technosphere input of the EcoSpold delivery is in the graph | PASS | all present (bafu_links_check.py) |
| uncertainty declared on the direct exchanges | PASS | 6/6 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values |
| Monte Carlo 95 % interval contains the deterministic score | PASS | 0.03114 in [0.02421, 0.06062] |
| time period declared | PASS | 2018-01/2018-12 |
| geography is a known location code | PASS | CZ |
| sources cited | PASS | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them |
BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.
To suggest a correction or a dataset that does not exist yet, use Propose a dataset.