Ventilation system, central, 1 x 720 m3/h, steel ducts, with GHE — CH

Dataset documentation and final control (tdc-doc, imported mode)
Open this dataset in OpenData

Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Ventilation system, central, 1 x 720 m3/h, steel ducts, with GHE [CH], per 1 p. EF v3.1 climate change 1.132e+04 kg CO2 eq (Monte Carlo 95 % interval 1.084e+04–1.421e+04). Main contributors: Ventilation duct, steel, 100×50 mm, at plant 37 %; Spiral-seam duct, steel, DN 400, at plant 11 %; Ground heat exchanger, PE, DN 200, at plant 10 %; Disposal, building, polyethylene/polypropylene products, to … 10 %; Ventilation equipment, central, 600-1200 m3/h, at plant 6 %; Air distribution housing, steel, 120 m3/h, at plant 4 %. Status: final control passed.
Item Value
Dataset name Ventilation system, central, 1 x 720 m3/h, steel ducts, with GHE
Dataset UUID / graph id d3405832-5079-3417-9494-43e92dcf3c0a / activity:ventilation_system_central_1_x_720_m3_h_steel_ducts_with_ghe__ch
Reference product, unit Ventilation system, central, 1 x 720 m3/h, steel ducts, with GHE, 1 p
Location CH
Time period 2003-01/2003-12
Category construction / ventilation\components\infrastructure
Source database BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1
Publisher Swiss Federal Office for the Environment (FOEN/BAFU)
Background database BAFU 2026 v1 (graph bafuquery-db)
LCIA method EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix)
Status final control passed
Documented by tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17

Introduction

Ventilation system for a multi family house. The house considered in the investigation includes 6 flats with 130 m2 floor area each and a ventilation rate of 120 m3/h. The influence of a smaller concrete demand due to embedment of ventilation tubes in the concrete of the floor (-8.05 kg concrete per m2 floor area) is not included.; UUID: d3405832-5079-3417-9494-43e92dcf3c0a

This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.

Goal and scope

Function, functional unit and reference flow

Reference flow: 1 p of Ventilation system, central, 1 x 720 m3/h, steel ducts, with GHE (CH). All results are given per unit of the reference flow.

System boundary

Materials used for the ventilation system. Transport of the components to the construction site. Disposal of the components included. Influence of ventilation ducts on building construction not included. No materials for renwal of components included. Operation of system not included.

Technology

Central ventilation system including 4 parallel polyethylene ground heat exchanger tubes (200 mm diameter). Air distribution from the central ventilation unit with a galvanised steel tube (400 mm diameter) to the distribution housings in the 6 flats. Distribution of fresh- and exhaust-air within the flat with galvanised steel ducts (100×50 mm). Exhaust air from the air collection housings in the 6 flats with a galvanised steel tube (400 mm diameter) to the central ventilation unit. Exhaust air from the ventilation unit to the outside air with a galvanised steel tube (400 mm diameter).

Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).

LCIA method

EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.

Life cycle inventory

Inventory table

Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).

Exchange Type Location / compartment Amount Unit Uncertainty Pedigree GWP share (%) Notes
Ventilation duct, steel, 100×50 mm, at plant technosphere RER 600 m lognormal, GSD² 1.12 — 37.0 ███████
Spiral-seam duct, steel, DN 400, at plant technosphere RER 45 m lognormal, GSD² 1.12 — 11.2 ██
Ground heat exchanger, PE, DN 200, at plant technosphere RER 120 m lognormal, GSD² 1.12 — 10.1 ██
Disposal, building, polyethylene/polypropylene products, to final disposal technosphere CH 360 kg lognormal, GSD² 1.12 — 9.6 ██
Ventilation equipment, central, 600-1200 m3/h, at plant technosphere RER 1 p lognormal, GSD² 1.12 — 5.7 █
Air distribution housing, steel, 120 m3/h, at plant technosphere CH 12 p lognormal, GSD² 1.12 — 3.8 █
Silencer, steel, DN 125, at plant technosphere CH 12 p lognormal, GSD² 1.12 — 3.0 █
Elbow 90°, steel, 100×50 mm, at plant technosphere RER 228 p lognormal, GSD² 1.12 — 2.6 █
Supply air inlet, steel, SS, DN 75, at plant technosphere RER 30 p lognormal, GSD² 1.12 — 2.5 █
Insulation spiral-seam duct, rockwool, DN 400, 30 mm, at plant technosphere RER 20 m lognormal, GSD² 1.12 — 2.2 ·
Outside air intake, stainless steel, DN 370, at plant technosphere RER 1 p lognormal, GSD² 1.12 — 1.6 ·
Sealing tape, aluminum/PE, 50 mm wide, at plant technosphere RER 700 m lognormal, GSD² 1.12 — 1.3 ·
Connection piece, steel, 100×50 mm, at plant technosphere RER 150 p lognormal, GSD² 1.12 — 1.2 ·
Silencer, steel, DN 315, 50 mm, at plant technosphere CH 2 p lognormal, GSD² 1.12 — 1.1 ·
Transport, freight, lorry, 3.5t gross weight, fleet average technosphere CH 115 tkm lognormal, GSD² 2.06 — 1.1 ·
Spiral-seam duct, steel, DN 125, at plant technosphere RER 12 m lognormal, GSD² 1.12 — 1.0 ·
Transport, freight, lorry, fleet average technosphere RER 532 tkm lognormal, GSD² 2.02 — 0.9 ·
Disposal, sealing tape, aluminum/PE, 50 mm wide technosphere CH 700 m lognormal, GSD² 1.12 — 0.8 ·
Overflow element, steel, approx. 40 m3/h technosphere RER 18 p lognormal, GSD² 1.12 — 0.8 ·
Excavation, hydraulic digger, average technosphere CH 137 m3 lognormal, GSD² 1.24 — 0.5 ·
Exhaust air roof hood, steel, DN 400, at plant technosphere CH 1 p lognormal, GSD² 1.12 — 0.5 ·
Exhaust air valve, in-wall housing, plastic/steel, DN 125, at plant technosphere CH 18 p lognormal, GSD² 1.12 — 0.3 ·
Control and wiring, central unit, at plant technosphere RER 1 p lognormal, GSD² 1.12 — 0.2 ·
Flexible duct, aluminum/PET, DN of 125, at plant technosphere RER 20 m lognormal, GSD² 1.12 — 0.2 ·
Disposal, overflow element, steel, approx. 40 m3/h technosphere CH 18 p lognormal, GSD² 1.12 — 0.1 ·
Disposal, air distribution housing, steel, 120 m3/h technosphere CH 12 p lognormal, GSD² 1.12 — 0.1 ·
Disposal, outside air intake, stainless steel, DN 370 technosphere CH 1 p lognormal, GSD² 1.12 — 0.1 ·
Disposal, flexible duct, aluminum/PET, DN of 125 technosphere CH 20 m lognormal, GSD² 1.12 — 0.0 ·
Air filter, in exhaust air valve, at plant technosphere RER 18 p lognormal, GSD² 1.12 — 0.0 ·
Disposal, building, bulk iron (excluding reinforcement), to sorting plant technosphere CH 1350 kg lognormal, GSD² 1.12 — 0.0 ·
Disposal, control and wiring, central unit technosphere CH 1 p lognormal, GSD² 1.12 — 0.0 ·
Air filter, central unit, 600 m3/h, at plant technosphere RER 2 p lognormal, GSD² 1.12 — 0.0 ·
Disposal, exhaust air valve, in-wall housing, plastic/steel, DN 125 technosphere CH 18 p lognormal, GSD² 1.12 — 0.0 ·
Disposal, ventilation equipment, central, 600-1200 m3/h technosphere CH 1 p lognormal, GSD² 1.12 — 0.0 ·
Transport, freight, lorry, 16t-32t gross weight, fleet average technosphere CH 8.84 tkm lognormal, GSD² 2.02 — 0.0 ·
Disposal, air filter, in exhaust air valve technosphere CH 18 p lognormal, GSD² 1.12 — 0.0 ·
Disposal, insulation spiral-seam duct, rockwool, DN 400, 30 mm technosphere CH 20 m lognormal, GSD² 1.12 — 0.0 ·
Disposal, silencer, steel, DN 125 technosphere CH 12 p lognormal, GSD² 1.12 — 0.0 ·
Disposal, silencer, steel, DN 315, 50 mm technosphere CH 2 p lognormal, GSD² 1.12 — 0.0 ·
Disposal, air filter, central unit, 600 m3/h technosphere CH 2 p lognormal, GSD² 1.12 — 0.0 ·
Disposal, exhaust air roof hood, steel, DN 400 technosphere CH 1 p lognormal, GSD² 1.12 — 0.0 ·

Data quality

0 of 41 direct exchanges carry a declared pedigree, 41 carry a distribution.

Field As declared by the publisher
Data generator / entry / validation data generator: Alex Primas (HSLU); data entry: Alex Primas (HSLU); validation (proof reading): Rolf Frischknecht (TREEZE)
extrapolations none
sampling procedure Questionnaire and assumptions. Data valid for example building used.
production volume na
uncertainty adjustments none
validation details Proof reading validation: passed; Other validation: none;
time period comment Amount of material investigated in 2003

Data gaps, proxies and assumptions

None recorded.

Life cycle impact assessment (EF v3.1)

Per 1 p. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.

Impact category Indicator Unit Result 2.5 % 97.5 % GSD²
Acidification Accumulated Exceedance (AE) mol H+ eq 241.8 140.6 472.4 1.87
Climate change-Biogenic Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 22.03 14.48 54.24 1.97
Climate change-Fossil Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 1.13e+04 1.081e+04 1.418e+04 1.14
Climate change-Land use and land use change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 5.08 4.116 8.738 1.45
Climate change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 1.132e+04 1.084e+04 1.421e+04 1.14
EF-particulate Matter Impact on human health disease incidence 0.002494 0.001677 0.004409 1.61
Ecotoxicity, freshwater_inorganics Comparative Toxic Unit for ecosystems (CTUe) CTUe 5.152e+04 4.591e+04 9.899e+04 1.5
Ecotoxicity, freshwater_organics Comparative Toxic Unit for ecosystems (CTUe) CTUe 943.4 913.9 1718 1.46
Ecotoxicity, freshwater Comparative Toxic Unit for ecosystems (CTUe) CTUe 5.247e+04 4.698e+04 1.003e+05 1.49
Eutrophication marine Fraction of nutrients reaching marine end compartment (N) kg N eq 14.05 11.22 22.99 1.43
Eutrophication, freshwater Fraction of nutrients reaching freshwater end compartment (P) kg P eq 5.131 3.601 25.39 2.71
Eutrophication, terrestrial Accumulated Exceedance (AE) mol N eq 991.5 537.1 2016 1.98
Human toxicity, cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 5.652e-06 4.939e-06 1.670e-05 1.84
Human toxicity, cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 4.288e-06 3.477e-06 1.073e-05 1.76
Human toxicity, cancer Comparative Toxic Unit for human (CTUh) CTUh 9.940e-06 9.182e-06 2.468e-05 1.62
Human toxicity, non-cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 5.785e-04 4.172e-04 0.00187 2.12
Human toxicity, non-cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 2.205e-05 1.272e-05 5.214e-05 2.02
Human toxicity, non-cancer Comparative Toxic Unit for human (CTUh) CTUh 6.005e-04 4.390e-04 0.001893 2.09
Ionising radiation, human health Human exposure efficiency relative to U235 kBq U235 eq 2392 871.5 1.483e+04 4.26
Land use Soil quality index pt (soil quality index) 5.079e+04 4.658e+04 8.895e+04 1.39
Ozone depletion Ozone Depletion Potential (ODP) kg CFC-11 eq 3.757e-04 3.178e-04 6.010e-04 1.38
Photochemical ozone formation - human health Tropospheric ozone concentration increase kg NMVOC eq 33.19 30.9 52.43 1.31
Resource use, fossils Abiotic resource depletion fossil fuels (ADP-fossil) MJ 1.399e+05 1.265e+05 2.048e+05 1.28
Resource use, minerals and metals Abiotic resource depletion (ADP ultimate reserve) kg Sb eq 0.3202 -0.8676 2.431 —
Water use User deprivation potential (deprivation-weighted water consumption) m3 world eq deprived 875.9 -1.517e+06 7.630e+05 —

Climate change 1.132e+04 kg CO2 eq per p. Main contributors: Ventilation duct, steel, 100×50 mm, at plant 37 %; Spiral-seam duct, steel, DN 400, at plant 11 %; Ground heat exchanger, PE, DN 200, at plant 10 %; Disposal, building, polyethylene/polypropylene products, to … 10 %; Ventilation equipment, central, 600-1200 m3/h, at plant 6 %; Air distribution housing, steel, 120 m3/h, at plant 4 %.

Interpretation

Significant issues

Direct exchanges dominating climate change: Ventilation duct, steel, 100×50 mm, at plant 37 %; Spiral-seam duct, steel, DN 400, at plant 11 %; Ground heat exchanger, PE, DN 200, at plant 10 %; Disposal, building, polyethylene/polypropylene products, to … 10 %; Ventilation equipment, central, 600-1200 m3/h, at plant 6 %; Air distribution housing, steel, 120 m3/h, at plant 4 %. Most sensitive exchanges (Section 6.3): Ventilation duct, steel, 100×50 mm, at plant [RER] (-3.9 / +4.4 %); Spiral-seam duct, steel, DN 400, at plant [RER] (-1.2 / +1.3 %); Ground heat exchanger, PE, DN 200, at plant [RER] (-1.1 / +1.2 %).

Independent recalculation

Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026):

Category Graph Published Graph / published
Acidification 241.8 245.6 0.984
Climate change-Biogenic 22.03 22.03 1.000
Climate change-Fossil 1.13e+04 1.13e+04 1.000
Climate change-Land use and land use change 5.08 5.08 1.000
Climate change 1.132e+04 1.132e+04 1.000
EF-particulate Matter 0.002494 0.002494 1.000
Ecotoxicity, freshwater_inorganics 5.152e+04 5.138e+04 1.003
Ecotoxicity, freshwater_organics 943.4 935.1 1.009
Ecotoxicity, freshwater 5.247e+04 5.226e+04 1.004
Eutrophication marine 14.05 14.05 1.000
Eutrophication, freshwater 5.131 5.131 1.000
Eutrophication, terrestrial 991.5 995.7 0.996
Human toxicity, cancer_inorganics 5.652e-06 5.623e-06 1.005
Human toxicity, cancer_organics 4.288e-06 4.288e-06 1.000
Human toxicity, cancer 9.940e-06 9.911e-06 1.003
Human toxicity, non-cancer_inorganics 5.785e-04 5.773e-04 1.002
Human toxicity, non-cancer_organics 2.205e-05 2.205e-05 1.000
Human toxicity, non-cancer 6.005e-04 5.993e-04 1.002
Ionising radiation, human health 2392 2392 1.000
Land use 5.079e+04 3.863e+04 1.315
Ozone depletion 3.757e-04 3.757e-04 1.000
Photochemical ozone formation - human health 33.19 33.19 1.000
Resource use, fossils 1.399e+05 1.400e+05 1.000
Resource use, minerals and metals 0.3202 0.3151 1.016
Water use 875.9 957.1 0.915
Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like.
Also published by BAFU for this dataset: IPCC 2021 GWP100 1.132e+04 kg CO2 eq; Ecological Scarcity
2021 total 3.116e+07 UBP.

Sensitivity check

One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.

Exchange Base Low / high Range Δ GWP100 (%) Δ other categories (max %)
Ventilation duct, steel, 100×50 mm, at plant [RER] 600 m ×0.895 / ×1.12 lognormal, GSD² 1.12 -3.9 / +4.4 6.7 (Eutrophication, terrestrial)
Spiral-seam duct, steel, DN 400, at plant [RER] 45 m ×0.895 / ×1.12 lognormal, GSD² 1.12 -1.2 / +1.3 2.1 (Eutrophication, terrestrial)
Ground heat exchanger, PE, DN 200, at plant [RER] 120 m ×0.895 / ×1.12 lognormal, GSD² 1.12 -1.1 / +1.2 2.6 (Resource use, fossils)
Disposal, building, polyethylene/polypropylene products, to final disposal [CH] 360 kg ×0.895 / ×1.12 lognormal, GSD² 1.12 -1.0 / +1.1 1.1 (Climate change-Fossil)
Transport, freight, lorry, 3.5t gross weight, fleet average [CH] 115 tkm ×0.493 / ×2.03 lognormal, GSD² 2.06 -0.6 / +1.1 5.3 (Ozone depletion)
Transport, freight, lorry, fleet average [RER] 532 tkm ×0.502 / ×1.99 lognormal, GSD² 2.02 -0.4 / +0.9 7.5 (Climate change-Land use and land use change)
Ventilation equipment, central, 600-1200 m3/h, at plant [RER] 1 p ×0.895 / ×1.12 lognormal, GSD² 1.12 -0.6 / +0.7 1.0 (Ionising radiation, human health)
Air distribution housing, steel, 120 m3/h, at plant [CH] 12 p ×0.895 / ×1.12 lognormal, GSD² 1.12 -0.4 / +0.4 0.5 (Ecotoxicity, freshwater_inorganics)
Silencer, steel, DN 125, at plant [CH] 12 p ×0.895 / ×1.12 lognormal, GSD² 1.12 -0.3 / +0.4 0.8 (Human toxicity, cancer_organics)
Elbow 90°, steel, 100×50 mm, at plant [RER] 228 p ×0.895 / ×1.12 lognormal, GSD² 1.12 -0.3 / +0.3 0.5 (Eutrophication, terrestrial)
Supply air inlet, steel, SS, DN 75, at plant [RER] 30 p ×0.895 / ×1.12 lognormal, GSD² 1.12 -0.3 / +0.3 0.4 (Climate change-Biogenic)
Insulation spiral-seam duct, rockwool, DN 400, 30 mm, at plant [RER] 20 m ×0.895 / ×1.12 lognormal, GSD² 1.12 -0.2 / +0.3 0.5 (Ecotoxicity, freshwater_organics)
Outside air intake, stainless steel, DN 370, at plant [RER] 1 p ×0.895 / ×1.12 lognormal, GSD² 1.12 -0.2 / +0.2 0.4 (Human toxicity, cancer_inorganics)
Sealing tape, aluminum/PE, 50 mm wide, at plant [RER] 700 m ×0.895 / ×1.12 lognormal, GSD² 1.12 -0.1 / +0.2 0.5 (Ecotoxicity, freshwater_organics)
Connection piece, steel, 100×50 mm, at plant [RER] 150 p ×0.895 / ×1.12 lognormal, GSD² 1.12 -0.1 / +0.1 0.2 (Eutrophication, terrestrial)

Uncertainty analysis

Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.

Comparison with other data

No other location of this dataset in the graph.

Conclusions and limitations

GWP100 1.132e+04 kg CO2 eq per p (95 % interval 1.084e+04–1.421e+04). Dominant contributors: Ventilation duct, steel, 100×50 mm, at plant 37 %; Spiral-seam duct, steel, DN 400, at plant 11 %; Ground heat exchanger, PE, DN 200, at plant 10 %; Disposal, building, polyethylene/polypropylene products, to … 10 %; Ventilation equipment, central, 600-1200 m3/h, at plant 6 %; Air distribution housing, steel, 120 m3/h, at plant 4 %. Most sensitive: Ventilation duct, steel, 100×50 mm, at plant [RER] (-3.9 / +4.4 %); Spiral-seam duct, steel, DN 400, at plant [RER] (-1.2 / +1.3 %); Ground heat exchanger, PE, DN 200, at plant [RER] (-1.1 / +1.2 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.

Final control

Item Status Detail
reference flow PASS production amount 1.0 p
closure: sum of direct contributions = dataset score (all 25 categories) PASS largest relative gap 8.1e-16
independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) PASS graph / published = 1; categories within ±5 %: 23/25
every technosphere input of the EcoSpold delivery is in the graph PASS all present (bafu_links_check.py)
uncertainty declared on the direct exchanges PASS 41/41 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values
Monte Carlo 95 % interval contains the deterministic score PASS 1.132e+04 in [1.084e+04, 1.421e+04]
time period declared PASS 2003-01/2003-12
geography is a known location code PASS CH
sources cited PASS 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them

References

  1. Hässig, W., Primas, A. (2007) Ökologische Aspekte der Komfortlüftungen im Wohnbereich. Final report ecoinvent Data v2.0. Volume: 25. Swiss Centre for LCI, B+H. Dübendorf and Zürich, CH. Type: Measurement on site Source: CD-ROM First author: Hässig, W. Other authors: Primas, A. Year: 2007 Title of anthology: Final report ecoinvent Data v2.0 Place of publication: Dübendorf and Zürich, CH Publisher: … — published source; as declared by BAFU (not found in OpenAlex/Crossref)
  2. Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — database; dataset citation
  3. International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva.
  4. Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. (tdc-doc method reference; title, version and year to verify against the user's copy)
  5. European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra.
  6. Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236

Annex — licence and terms of use

BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.


To suggest a correction or a dataset that does not exist yet, use Propose a dataset.