Table of Contents

Disposal, ventilation system, Geschäftshaus C, Esslingen, various components — CH

Dataset documentation and final control (tdc-doc, imported mode)
Open this dataset in OpenData

Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Disposal, ventilation system, Geschäftshaus C, Esslingen, various components [CH], per 1 p. EF v3.1 climate change 21.5 kg CO2 eq (Monte Carlo 95 % interval 18.91–25.08). Main contributors: Disposal, rubber, unspecified, 0% water, to municipal incine… 60 %; Disposal, building, bulk iron (excluding reinforcement), to … 16 %; Disposal, building, mineral wool, to sorting plant 12 %; Disposal, building, polyethylene/polypropylene products, to … 10 %; Disposal, building, polyvinylchloride products, to final dis… 2 %. Status: final control passed.
Item Value
Dataset name Disposal, ventilation system, Geschäftshaus C, Esslingen, various components
Dataset UUID / graph id d8d4decd-e811-4f31-89fa-5ccec8abb9dc / activity:disposal_ventilation_system_geschäftshaus_c_esslingen_various_components__ch
Reference product, unit Disposal, ventilation system, Geschäftshaus C, Esslingen, various components, 1 p
Location CH — Specific to the technology mix encountered in sorting plants in Switzerland.
Time period 2014-01/2014-12
Category waste management / building demolition
Source database BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1
Publisher Swiss Federal Office for the Environment (FOEN/BAFU)
Background database BAFU 2026 v1 (graph bafuquery-db)
LCIA method EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix)
Status final control passed
Documented by tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17

Introduction

Disposal of various components for a ventilation system for an office building with offices only (no kitchen, restaurant or car park). The inventory is based on a building with a total heated gross floor area of 2621 m2 and a total nominal air flow of 4000 m3/h, total weight of the components: 1210 kg/Unit, building with a specific air flow rate of 1.5 m3/h per m2 heated gross floor area. Data from call of bid including components for air valves, air intake, roof-hoods, dampers, fire dampers, silencers and sensors.; UUID: d8d4decd-e811-4f31-89fa-5ccec8abb9dc

This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.

Goal and scope

Function, functional unit and reference flow

Reference flow: 1 p of Disposal, ventilation system, Geschäftshaus C, Esslingen, various components (CH). All results are given per unit of the reference flow.

System boundary

Transport to dismantling facilities, machines for handling in sorting plant, electricity demand for sorting plant, final disposal of waste material. Cut-off to recycling for metals.

Technology

Disposal to a sorting plant assumed. Metal pieces, copper in cables and electronic devices are recycled, plastic parts are incinerated, inert wastes (e.g. rock wool) are landfilled.

Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).

LCIA method

EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.

Life cycle inventory

Inventory table

Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).

Exchange Type Location / compartment Amount Unit Uncertainty Pedigree GWP share (%) Notes
Disposal, rubber, unspecified, 0% water, to municipal incineration technosphere CH 4.0778 kg lognormal, GSD² 1.26 (3,4,1,1,1,5) 59.9 ████████████
Disposal, building, bulk iron (excluding reinforcement), to sorting plant technosphere CH 1052 kg lognormal, GSD² 1.26 (3,4,1,1,1,5) 16.4 ███
Disposal, building, mineral wool, to sorting plant technosphere CH 152.72 kg lognormal, GSD² 1.26 (3,4,1,1,1,5) 11.7 ██
Disposal, building, polyethylene/polypropylene products, to final disposal technosphere CH 0.678 kg lognormal, GSD² 1.26 (3,4,1,1,1,5) 9.6 ██
Disposal, building, polyvinylchloride products, to final disposal technosphere CH 0.222 kg lognormal, GSD² 1.26 (3,4,1,1,1,5) 2.1 ·
Disposal, electronics for control units technosphere RER 0.06 kg lognormal, GSD² 1.34 (3,4,1,1,3,5) 0.3 ·
Disposal, building, paint on metal, to sorting plant technosphere CH 0.016949 kg lognormal, GSD² 1.26 (3,4,1,1,1,5) 0.0 ·

Data quality

7 of 7 direct exchanges carry a declared pedigree, 7 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 3.0 · completeness 4.0 · temporal 1.0 · geographical 1.0 · technological 1.29 · sample size 5.0.

Field As declared by the publisher
Data generator / entry / validation data generator: Alex Primas (HSLU); data entry: Alex Primas (HSLU); validation (proof reading): Alex Primas (HSLU)
extrapolations none
sampling procedure Waste-specific calculation based on production input data
production volume na
uncertainty adjustments none
time period comment Amount of material investigated in 2013. Disposal technology mix as used in late 1990ies

Data gaps, proxies and assumptions

None recorded.

Life cycle impact assessment (EF v3.1)

Per 1 p. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.

Impact category Indicator Unit Result 2.5 % 97.5 % GSD²
Acidification Accumulated Exceedance (AE) mol H+ eq 0.01301 0.01178 0.01737 1.22
Climate change-Biogenic Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.01327 0.009893 0.02338 1.53
Climate change-Fossil Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 21.49 18.9 25.06 1.16
Climate change-Land use and land use change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.002216 0.001806 0.003287 1.37
Climate change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 21.5 18.91 25.08 1.16
EF-particulate Matter Impact on human health disease incidence 1.326e-06 7.900e-07 2.796e-06 1.86
Ecotoxicity, freshwater_inorganics Comparative Toxic Unit for ecosystems (CTUe) CTUe 61.07 49.59 106.4 1.5
Ecotoxicity, freshwater_organics Comparative Toxic Unit for ecosystems (CTUe) CTUe 1.051 0.8563 1.893 1.52
Ecotoxicity, freshwater Comparative Toxic Unit for ecosystems (CTUe) CTUe 62.13 50.84 107.6 1.49
Eutrophication marine Fraction of nutrients reaching marine end compartment (N) kg N eq 0.01043 0.009081 0.01351 1.22
Eutrophication, freshwater Fraction of nutrients reaching freshwater end compartment (P) kg P eq 0.01056 0.001456 0.285 16.4
Eutrophication, terrestrial Accumulated Exceedance (AE) mol N eq 0.08961 0.0781 0.1158 1.22
Human toxicity, cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 7.545e-10 8.556e-10 1.952e-09 1.51
Human toxicity, cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 1.241e-09 1.027e-09 1.847e-09 1.35
Human toxicity, cancer Comparative Toxic Unit for human (CTUh) CTUh 1.995e-09 2.005e-09 3.459e-09 1.32
Human toxicity, non-cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 4.906e-08 5.257e-08 1.077e-07 1.46
Human toxicity, non-cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 1.067e-08 8.053e-09 1.603e-08 1.41
Human toxicity, non-cancer Comparative Toxic Unit for human (CTUh) CTUh 5.973e-08 6.301e-08 1.196e-07 1.4
Ionising radiation, human health Human exposure efficiency relative to U235 kBq U235 eq 2.509 0.9202 14.22 4.18
Land use Soil quality index pt (soil quality index) 90.79 5.352 213 —
Ozone depletion Ozone Depletion Potential (ODP) kg CFC-11 eq 2.242e-07 1.888e-07 3.210e-07 1.31
Photochemical ozone formation - human health Tropospheric ozone concentration increase kg NMVOC eq 0.04003 0.03406 0.05476 1.27
Resource use, fossils Abiotic resource depletion fossil fuels (ADP-fossil) MJ 103.5 90.53 133.4 1.23
Resource use, minerals and metals Abiotic resource depletion (ADP ultimate reserve) kg Sb eq 1.403e-05 1.117e-05 2.724e-05 1.6
Water use User deprivation potential (deprivation-weighted water consumption) m3 world eq deprived 2.016 -985.9 498.8 —

Climate change 21.5 kg CO2 eq per p. Main contributors: Disposal, rubber, unspecified, 0% water, to municipal incine… 60 %; Disposal, building, bulk iron (excluding reinforcement), to … 16 %; Disposal, building, mineral wool, to sorting plant 12 %; Disposal, building, polyethylene/polypropylene products, to … 10 %; Disposal, building, polyvinylchloride products, to final dis… 2 %.

Interpretation

Significant issues

Direct exchanges dominating climate change: Disposal, rubber, unspecified, 0% water, to municipal incine… 60 %; Disposal, building, bulk iron (excluding reinforcement), to … 16 %; Disposal, building, mineral wool, to sorting plant 12 %; Disposal, building, polyethylene/polypropylene products, to … 10 %; Disposal, building, polyvinylchloride products, to final dis… 2 %. Most sensitive exchanges (Section 6.3): Disposal, rubber, unspecified, 0% water, to municipal incineration [CH] (-12.1 / +15.2 %); Disposal, building, bulk iron (excluding reinforcement), to sorting plant [CH] (-3.3 / +4.2 %); Disposal, building, mineral wool, to sorting plant [CH] (-2.4 / +3.0 %).

Independent recalculation

The publisher publishes no LCIA result for this dataset; the closure check of Section 7 is the recalculation test.

Sensitivity check

One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.

Exchange Base Low / high Range Δ GWP100 (%) Δ other categories (max %)
Disposal, rubber, unspecified, 0% water, to municipal incineration [CH] 4.078 kg ×0.797 / ×1.25 lognormal, GSD² 1.26 -12.1 / +15.2 15.2 (Climate change-Fossil)
Disposal, building, bulk iron (excluding reinforcement), to sorting plant [CH] 1052 kg ×0.797 / ×1.25 lognormal, GSD² 1.26 -3.3 / +4.2 20.6 (Ionising radiation, human health)
Disposal, building, mineral wool, to sorting plant [CH] 152.7 kg ×0.797 / ×1.25 lognormal, GSD² 1.26 -2.4 / +3.0 24.1 (Eutrophication, freshwater)
Disposal, building, polyethylene/polypropylene products, to final disposal [CH] 0.678 kg ×0.797 / ×1.25 lognormal, GSD² 1.26 -1.9 / +2.4 2.4 (Climate change-Fossil)
Disposal, building, polyvinylchloride products, to final disposal [CH] 0.222 kg ×0.797 / ×1.25 lognormal, GSD² 1.26 -0.4 / +0.5 11.2 (Water use)
Disposal, electronics for control units [RER] 0.06 kg ×0.751 / ×1.33 lognormal, GSD² 1.34 -0.1 / +0.1 0.9 (Human toxicity, non-cancer_inorganics)
Disposal, building, paint on metal, to sorting plant [CH] 0.01695 kg ×0.797 / ×1.25 lognormal, GSD² 1.26 -0.0 / +0.0 0.0 (Ionising radiation, human health)

Uncertainty analysis

Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.

Comparison with other data

No other location of this dataset in the graph.

Conclusions and limitations

GWP100 21.5 kg CO2 eq per p (95 % interval 18.91–25.08). Dominant contributors: Disposal, rubber, unspecified, 0% water, to municipal incine… 60 %; Disposal, building, bulk iron (excluding reinforcement), to … 16 %; Disposal, building, mineral wool, to sorting plant 12 %; Disposal, building, polyethylene/polypropylene products, to … 10 %; Disposal, building, polyvinylchloride products, to final dis… 2 %. Most sensitive: Disposal, rubber, unspecified, 0% water, to municipal incineration [CH] (-12.1 / +15.2 %); Disposal, building, bulk iron (excluding reinforcement), to sorting plant [CH] (-3.3 / +4.2 %); Disposal, building, mineral wool, to sorting plant [CH] (-2.4 / +3.0 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.

Final control

Item Status Detail
reference flow PASS production amount 1.0 p
closure: sum of direct contributions = dataset score (all 25 categories) PASS largest relative gap 2.2e-16
every technosphere input of the EcoSpold delivery is in the graph PASS all present (bafu_links_check.py)
uncertainty declared on the direct exchanges PASS 7/7 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values
Monte Carlo 95 % interval contains the deterministic score PASS 21.5 in [18.91, 25.08]
time period declared PASS 2014-01/2014-12
geography is a known location code PASS CH
sources cited PASS 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them

References

  1. Klingler M., Kasser U., Savi D., Primas A., Stettler Y., Gujer P. (2014) Ökobilanzdaten für Lüftungs- und Wärmeanlagen. Schlussbericht, BFE. Bundesamt für Energie (BFE). Bern. Type: Separate publication Source: Report First author: Klingler M. Other authors: Kasser U., Savi D., Primas A., Stettler Y., Gujer P. Year: 2014 Title of anthology: Schlussbericht, BFE Place of publication: Bern Publisher:… — published source; as declared by BAFU (not found in OpenAlex/Crossref)
  2. Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — database; dataset citation
  3. International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva.
  4. Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. (tdc-doc method reference; title, version and year to verify against the user's copy)
  5. European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra.
  6. Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236

Annex — licence and terms of use

BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.


To suggest a correction or a dataset that does not exist yet, use Propose a dataset.