Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Photovoltaic panel for PVT, single-Si, without flat glass, at plant [RER], per 1 m2. EF v3.1 climate change 85.68 kg CO2 eq (Monte Carlo 95 % interval 66.36–174.1). Main contributors: Photovoltaic cell, single-Si, at plant 49 %; Aluminium alloy, AlMg3, at plant 17 %; Solar glass, low-iron, at regional storage 11 %; Disposal, plastics, mixture, 15.3% water, to municipal incin… 5 %; Glass fibre reinforced plastic, polyamide, injection mouldin… 3 %; Ethylvinylacetate, foil, at plant 3 %. Status: final control passed.
Item Value
Dataset name Photovoltaic panel for PVT, single-Si, without flat glass, at plant
Dataset UUID / graph id e2e252d5-a5ca-3a11-b3f9-d51937a97c6f / activity:photovoltaic_panel_for_pvt_single_si_without_flat_glass_at_plant__rer
Reference product, unit Photovoltaic panel for PVT, single-Si, without flat glass, at plant, 1 m2
Location RER
Time period 2015-01/2020-12
Category heat / pvt\heating systems
Source database BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1
Publisher Swiss Federal Office for the Environment (FOEN/BAFU)
Background database BAFU 2026 v1 (graph bafuquery-db)
LCIA method EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix)
Status final control passed
Documented by tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17

Introduction

Unit process raw data for 1 m2 of PV panel ONLY FOR PVT-SYSTEM! (without flat glass!). Investigated for the production of solar panels and laminates with 60 solar cells a 156*156mm2 (=1.6m2 panel) with a capacity of 224 Wp and a panel efficiency of 14.0%. Cell size and amount and capacity might differ between different producers; Synonyms: Solarmodul nur für PVT-Systeme, PV-module for PVT systems only, monocrystalline, silicon, WITHOUT FLAT GLASS,; UUID: e2e252d5-a5ca-3a11-b3f9-d51937a97c6f

This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.

Goal and scope

Function, functional unit and reference flow

Reference flow: 1 m2 of Photovoltaic panel for PVT, single-Si, without flat glass, at plant (RER). All results are given per unit of the reference flow.

System boundary

Production of the cell matrix, cutting of foils and washing of glass, production of laminate, isolation. Aluminium frame of the panel. Disposal after end of life. Data for direct air and water emissions were not available. It can be expected that small amount of NMVOC will be emitted from the lamination process. WITHOUT flat glass.

Technology

Modern production plant.

Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).

LCIA method

EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.

Life cycle inventory

Inventory table

Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).

Exchange Type Location / compartment Amount Unit Uncertainty Pedigree GWP share (%) Notes
Photovoltaic cell, single-Si, at plant technosphere RER 0.93541 m2 lognormal, GSD² 1.13 — 48.7 ██████████
Aluminium alloy, AlMg3, at plant technosphere RER 2.125 kg lognormal, GSD² 1.13 — 17.4 ███
Solar glass, low-iron, at regional storage technosphere RER 8.8125 kg lognormal, GSD² 1.24 — 11.4 ██
Disposal, plastics, mixture, 15.3% water, to municipal incineration technosphere CH 1.6375 kg lognormal, GSD² 1.13 — 4.6 █
Glass fibre reinforced plastic, polyamide, injection moulding, at plant technosphere RER 0.295 kg lognormal, GSD² 1.13 — 3.0 █
Ethylvinylacetate, foil, at plant technosphere RER 0.875 kg lognormal, GSD² 1.13 — 2.9 █
Polyvinylfluoride film, at plant technosphere US 0.11187 kg lognormal, GSD² 1.13 — 2.7 █
Transport, freight, lorry, fleet average technosphere RER 7.2435 tkm lognormal, GSD² 3.04 — 1.6 ·
Electricity, medium voltage, production ENTSO-E, at grid technosphere ENTSO-E 3.7312 kWh lognormal, GSD² 1.14 — 1.2 ·
Polyethylene terephthalate, granulate, amorphous, at plant technosphere RER 0.34562 kg lognormal, GSD² 1.13 — 1.1 ·
Photovoltaic panel factory technosphere GLO 4.0000e-06 p lognormal, GSD² 3.02 — 1.1 ·
Transport, freight, rail technosphere RER 54.668 tkm lognormal, GSD² 3.04 — 1.1 ·
Corrugated board, mixed fibre, single wall, at plant technosphere RER 0.7625 kg lognormal, GSD² 1.13 — 0.8 ·
Diode, unspecified, at plant technosphere GLO 0.0028125 kg lognormal, GSD² 1.29 — 0.6 ·
Silicone product, at plant technosphere RER 0.12187 kg lognormal, GSD² 1.13 — 0.4 ·
Disposal, polyvinylfluoride, 0.2% water, to municipal incineration technosphere CH 0.11187 kg lognormal, GSD² 1.13 — 0.3 ·
EUR-flat pallet technosphere RER 0.05 p lognormal, GSD² 1.29 — 0.3 ·
Copper, at regional storage technosphere RER 0.1025 kg lognormal, GSD² 1.13 — 0.2 ·
Tin, at regional storage technosphere RER 0.012875 kg lognormal, GSD² 1.29 — 0.2 ·
Hydrogen fluoride, at plant technosphere GLO 0.062375 kg lognormal, GSD² 1.29 — 0.2 ·
Potassium hydroxide, at regional storage technosphere RER 0.051437 kg lognormal, GSD² 1.29 — 0.1 ·
1-propanol, at plant technosphere RER 0.015875 kg lognormal, GSD² 1.13 — 0.1 ·
Polyethylene, HDPE, granulate, at plant technosphere RER 0.02375 kg lognormal, GSD² 1.29 — 0.1 ·
Wire drawing, copper technosphere RER 0.1025 kg lognormal, GSD² 1.13 — 0.0 ·
Soap, at plant technosphere RER 0.011562 kg lognormal, GSD² 1.29 — 0.0 ·
Disposal, municipal solid waste, 22.9% water, to municipal incineration technosphere CH 0.03 kg lognormal, GSD² 1.13 — 0.0 ·
Disposal, used mineral oil, 10% water, to hazardous waste incineration technosphere CH 0.0016062 kg lognormal, GSD² 1.13 — 0.0 ·
Isopropanol, at plant technosphere RER 0.001469 kg lognormal, GSD² 1.29 — 0.0 ·
Treatment, sewage, from residence, to wastewater treatment, class 2 technosphere CH 0.0050313 m3 lognormal, GSD² 1.13 — 0.0 ·
Tap water, at user technosphere RER 5.0312 kg lognormal, GSD² 1.13 — 0.0 ·
Diesel, burned in building machine, average technosphere CH 0.00875 MJ lognormal, GSD² 2.09 — 0.0 ·
Lead, at regional storage technosphere RER 7.2500e-04 kg lognormal, GSD² 1.29 — 0.0 ·
Carbon Dioxide (fossil) elementary air/Ground level / Urban (>1000 people/s… 0.021812 kg lognormal, GSD² 1.29 — 0.0 ·
Waste Heat elementary air/Ground level / Urban (>1000 people/s… 13.432 MJ lognormal, GSD² 1.29 — 0.0 ·
Non-methane Volatile Organic Compounds elementary air/Ground level / Urban (>1000 people/s… 0.0080625 kg lognormal, GSD² 1.61 — 0.0 ·

Data quality

0 of 35 direct exchanges carry a declared pedigree, 35 carry a distribution.

Field As declared by the publisher
Data generator / entry / validation data generator: Livia Waldburger (CARBOTECH); data entry: Thomas Kaegi (CARBOTECH); validation (proof reading): Andy Spoerri (EBP)
extrapolations
sampling procedure Data provided by manufacturer, environmental reports, direct contacts with factory representatives and publication of plant data.
production volume na
uncertainty adjustments none
validation details Proof reading validation: 14.09.2020; Other validation: Z:\Schreibtisch\WinShare\BAFU Heizsysteme_A-Konvertieren\PVT[EcoSpold_photovoltaic panel for PVT, single-Si, without tempering flat glass, at plant_v0.1_lwa.xlsx]X-Process;
time period comment undefined

Data gaps, proxies and assumptions

None recorded.

Life cycle impact assessment (EF v3.1)

Per 1 m2. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.

Impact category Indicator Unit Result 2.5 % 97.5 % GSD²
Acidification Accumulated Exceedance (AE) mol H+ eq 0.3395 0.2684 0.6572 1.57
Climate change-Biogenic Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.8736 0.3619 3.115 2.96
Climate change-Fossil Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 84.76 65.82 171 1.63
Climate change-Land use and land use change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.05068 0.04079 0.08956 1.48
Climate change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 85.68 66.36 174.1 1.64
EF-particulate Matter Impact on human health disease incidence 3.028e-06 2.449e-06 2.082e-05 2.91
Ecotoxicity, freshwater_inorganics Comparative Toxic Unit for ecosystems (CTUe) CTUe 681.3 416.1 2053 2.28
Ecotoxicity, freshwater_organics Comparative Toxic Unit for ecosystems (CTUe) CTUe 9.901 8.716 21.37 1.61
Ecotoxicity, freshwater Comparative Toxic Unit for ecosystems (CTUe) CTUe 691.2 427 2071 2.26
Eutrophication marine Fraction of nutrients reaching marine end compartment (N) kg N eq 0.1631 0.1035 0.4081 2.03
Eutrophication, freshwater Fraction of nutrients reaching freshwater end compartment (P) kg P eq 0.04069 0.02837 0.1702 2.51
Eutrophication, terrestrial Accumulated Exceedance (AE) mol N eq 0.7618 0.5943 1.657 1.67
Human toxicity, cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 2.393e-08 2.192e-08 7.544e-08 1.94
Human toxicity, cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 2.637e-08 1.825e-08 6.464e-08 1.92
Human toxicity, cancer Comparative Toxic Unit for human (CTUh) CTUh 5.030e-08 4.216e-08 1.331e-07 1.81
Human toxicity, non-cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 1.260e-06 1.243e-06 3.985e-06 1.84
Human toxicity, non-cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 5.712e-08 4.918e-08 1.104e-07 1.52
Human toxicity, non-cancer Comparative Toxic Unit for human (CTUh) CTUh 1.318e-06 1.299e-06 4.066e-06 1.82
Ionising radiation, human health Human exposure efficiency relative to U235 kBq U235 eq 30.18 10.47 212.4 4.74
Land use Soil quality index pt (soil quality index) 744.3 621 1487 1.58
Ozone depletion Ozone Depletion Potential (ODP) kg CFC-11 eq 3.420e-06 2.291e-06 9.492e-06 2.08
Photochemical ozone formation - human health Tropospheric ozone concentration increase kg NMVOC eq 0.2727 0.224 0.5741 1.6
Resource use, fossils Abiotic resource depletion fossil fuels (ADP-fossil) MJ 1215 953.4 2724 1.71
Resource use, minerals and metals Abiotic resource depletion (ADP ultimate reserve) kg Sb eq 0.004472 0.003928 0.005346 1.17
Water use User deprivation potential (deprivation-weighted water consumption) m3 world eq deprived 39.34 -3.025e+04 1.661e+04 —

Climate change 85.68 kg CO2 eq per m2. Main contributors: Photovoltaic cell, single-Si, at plant 49 %; Aluminium alloy, AlMg3, at plant 17 %; Solar glass, low-iron, at regional storage 11 %; Disposal, plastics, mixture, 15.3% water, to municipal incin… 5 %; Glass fibre reinforced plastic, polyamide, injection mouldin… 3 %; Ethylvinylacetate, foil, at plant 3 %.

Interpretation

Significant issues

Direct exchanges dominating climate change: Photovoltaic cell, single-Si, at plant 49 %; Aluminium alloy, AlMg3, at plant 17 %; Solar glass, low-iron, at regional storage 11 %; Disposal, plastics, mixture, 15.3% water, to municipal incin… 5 %; Glass fibre reinforced plastic, polyamide, injection mouldin… 3 %; Ethylvinylacetate, foil, at plant 3 %. Most sensitive exchanges (Section 6.3): Photovoltaic cell, single-Si, at plant [RER] (-5.4 / +6.0 %); Solar glass, low-iron, at regional storage [RER] (-2.2 / +2.7 %); Transport, freight, lorry, fleet average [RER] (-1.1 / +3.1 %).

Independent recalculation

Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026):

Category Graph Published Graph / published
Acidification 0.3395 0.357 0.951
Climate change-Biogenic 0.8736 0.8736 1.000
Climate change-Fossil 84.76 84.76 1.000
Climate change-Land use and land use change 0.05068 0.05068 1.000
Climate change 85.68 85.68 1.000
EF-particulate Matter 3.028e-06 3.028e-06 1.000
Ecotoxicity, freshwater_inorganics 681.3 685.3 0.994
Ecotoxicity, freshwater_organics 9.901 7.381 1.341
Ecotoxicity, freshwater 691.2 692.1 0.999
Eutrophication marine 0.1631 0.1631 1.000
Eutrophication, freshwater 0.04069 0.04069 1.000
Eutrophication, terrestrial 0.7618 0.8152 0.934
Human toxicity, cancer_inorganics 2.393e-08 2.350e-08 1.018
Human toxicity, cancer_organics 2.637e-08 2.637e-08 1.000
Human toxicity, cancer 5.030e-08 4.987e-08 1.009
Human toxicity, non-cancer_inorganics 1.260e-06 1.245e-06 1.012
Human toxicity, non-cancer_organics 5.712e-08 5.699e-08 1.002
Human toxicity, non-cancer 1.318e-06 1.302e-06 1.012
Ionising radiation, human health 30.18 30.18 1.000
Land use 744.3 602.9 1.235
Ozone depletion 3.420e-06 3.420e-06 1.000
Photochemical ozone formation - human health 0.2727 0.2727 1.000
Resource use, fossils 1215 1216 1.000
Resource use, minerals and metals 0.004472 0.004407 1.015
Water use 39.34 39.22 1.003
Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like.
Also published by BAFU for this dataset: IPCC 2021 GWP100 85.5 kg CO2 eq; Ecological Scarcity
2021 total 1.824e+05 UBP.

Sensitivity check

One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.

Exchange Base Low / high Range Δ GWP100 (%) Δ other categories (max %)
Photovoltaic cell, single-Si, at plant [RER] 0.9354 m2 ×0.89 / ×1.12 lognormal, GSD² 1.13 -5.4 / +6.0 11.2 (Water use)
Solar glass, low-iron, at regional storage [RER] 8.812 kg ×0.808 / ×1.24 lognormal, GSD² 1.24 -2.2 / +2.7 6.9 (EF-particulate Matter)
Transport, freight, lorry, fleet average [RER] 7.244 tkm ×0.337 / ×2.97 lognormal, GSD² 3.04 -1.1 / +3.1 20.5 (Climate change-Land use and land use change)
Aluminium alloy, AlMg3, at plant [RER] 2.125 kg ×0.89 / ×1.12 lognormal, GSD² 1.13 -1.9 / +2.2 4.4 (Human toxicity, cancer_inorganics)
Photovoltaic panel factory [GLO] 4.000e-06 p ×0.339 / ×2.95 lognormal, GSD² 3.02 -0.7 / +2.1 18.0 (Land use)
Transport, freight, rail [RER] 54.67 tkm ×0.337 / ×2.97 lognormal, GSD² 3.04 -0.7 / +2.1 11.0 (Human toxicity, non-cancer_organics)
Disposal, plastics, mixture, 15.3% water, to municipal incineration [CH] 1.637 kg ×0.89 / ×1.12 lognormal, GSD² 1.13 -0.5 / +0.6 0.6 (Climate change-Fossil)
Glass fibre reinforced plastic, polyamide, injection moulding, at plant [RER] 0.295 kg ×0.89 / ×1.12 lognormal, GSD² 1.13 -0.3 / +0.4 0.6 (EF-particulate Matter)
Ethylvinylacetate, foil, at plant [RER] 0.875 kg ×0.89 / ×1.12 lognormal, GSD² 1.13 -0.3 / +0.4 3.7 (Ecotoxicity, freshwater_organics)
Polyvinylfluoride film, at plant [US] 0.1119 kg ×0.89 / ×1.12 lognormal, GSD² 1.13 -0.3 / +0.3 0.3 (Climate change-Fossil)
Diode, unspecified, at plant [GLO] 0.002812 kg ×0.782 / ×1.28 lognormal, GSD² 1.29 -0.1 / +0.2 0.4 (Human toxicity, non-cancer_organics)
Electricity, medium voltage, production ENTSO-E, at grid [ENTSO-E] 3.731 kWh ×0.883 / ×1.13 lognormal, GSD² 1.14 -0.1 / +0.2 0.6 (Ionising radiation, human health)
Polyethylene terephthalate, granulate, amorphous, at plant [RER] 0.3456 kg ×0.89 / ×1.12 lognormal, GSD² 1.13 -0.1 / +0.1 0.4 (Ecotoxicity, freshwater_organics)
Corrugated board, mixed fibre, single wall, at plant [RER] 0.7625 kg ×0.89 / ×1.12 lognormal, GSD² 1.13 -0.1 / +0.1 0.6 (Land use)
EUR-flat pallet [RER] 0.05 p ×0.782 / ×1.28 lognormal, GSD² 1.29 -0.1 / +0.1 6.3 (Land use)

Uncertainty analysis

Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.

Comparison with other data

Source Scope Value This dataset Ratio Note
bafu Photovoltaic panel for PVT, single-Si, without flat glass, at plant [APAC] 106.2 kg CO2 eq 85.68 0.81 same dataset name, other location
bafu Photovoltaic panel for PVT, single-Si, without flat glass, at plant [CN] 110.1 kg CO2 eq 85.68 0.78 same dataset name, other location

Conclusions and limitations

GWP100 85.68 kg CO2 eq per m2 (95 % interval 66.36–174.1). Dominant contributors: Photovoltaic cell, single-Si, at plant 49 %; Aluminium alloy, AlMg3, at plant 17 %; Solar glass, low-iron, at regional storage 11 %; Disposal, plastics, mixture, 15.3% water, to municipal incin… 5 %; Glass fibre reinforced plastic, polyamide, injection mouldin… 3 %; Ethylvinylacetate, foil, at plant 3 %. Most sensitive: Photovoltaic cell, single-Si, at plant [RER] (-5.4 / +6.0 %); Solar glass, low-iron, at regional storage [RER] (-2.2 / +2.7 %); Transport, freight, lorry, fleet average [RER] (-1.1 / +3.1 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.

Final control

Item Status Detail
reference flow PASS production amount 1.0 m2
closure: sum of direct contributions = dataset score (all 25 categories) PASS largest relative gap 3.9e-16
independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) PASS graph / published = 1; categories within ±5 %: 22/25
every technosphere input of the EcoSpold delivery is in the graph PASS all present (bafu_links_check.py)
uncertainty declared on the direct exchanges PASS 35/35 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values
Monte Carlo 95 % interval contains the deterministic score PASS 85.68 in [66.36, 174.1]
time period declared PASS 2015-01/2020-12
geography is a known location code PASS RER
sources cited PASS 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them

References

  1. Kägi Thomas, Livia Waldburger, Cyril Kern, Gavin Roberts, Mischa Zschokke, Flora Conte, Lea Weber (2020) LCI of heating systems. Carbotech im Auftrag des BAFU. Carbotech AG. Zürich. CH. Type: Separate publication Source: Report First author: Kägi Thomas Other authors: Livia Waldburger, Cyril Kern, Gavin Roberts, Mischa Zschokke, Flora Conte, Lea Weber Year: 2020 Title of anthology: Carbotech im Au… — published source; as declared by BAFU (not found in OpenAlex/Crossref)
  2. Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — database; dataset citation
  3. International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva.
  4. Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. (tdc-doc method reference; title, version and year to verify against the user's copy)
  5. European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra.
  6. Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236

Annex — licence and terms of use

BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.


To suggest a correction or a dataset that does not exist yet, use Propose a dataset.