Dataset documentation and final control (tdc-doc, imported mode)
Open this dataset in OpenData
Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Disposal, ventilation system, Schulhaus Fallätsche [CH], per 1 p. EF v3.1 climate change 1.202e+04 kg CO2 eq (Monte Carlo 95 % interval 1.059e+04–1.446e+04). Main contributors: Disposal, building, polyethylene/polypropylene products, to … 65 %; Disposal, ventilation unit 13000 m3/h, w. rotary heat exchan… 11 %; Disposal, ventilation unit 6700 m3/h, w. rotary heat exchang… 6 %; Disposal, ventilation unit 6700 m3/h, w. cross plate heat ex… 3 %; Disposal, EI 60 fire insulation, 70mm, 120kg/m3, reinforced … 2 %; Disposal, ventilation duct, steel, zinc coated, s= 0.62mm 2 %. Status: final control passed.
| Item | Value |
|---|---|
| Dataset name | Disposal, ventilation system, Schulhaus Fallätsche |
| Dataset UUID / graph id | ea2047f4-5331-4555-b115-4b343401bb2c / activity:disposal_ventilation_system_schulhaus_fallätsche__ch |
| Reference product, unit | Disposal, ventilation system, Schulhaus Fallätsche, 1 p |
| Location | CH — Specific to the technology mix encountered in sorting plants in Switzerland. |
| Time period | 2014-01/2014-12 |
| Category | waste management / building demolition |
| Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 |
| Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) |
| Background database | BAFU 2026 v1 (graph bafuquery-db) |
| LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) |
| Status | final control passed |
| Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 |
Disposal of a ventilation system for a school with schoolrooms, gym, public library and multi-purpose hall. The inventory is based on a building with a total heated gross floor area of 5607 m2 and a total nominal air flow of 35300 m3/h, total weight of the components: 12842 kg/Unit, building with a specific air flow rate of 6.3 m3/h per m2 heated gross floor area. Data from call of bid including components for air handling units, ducts including insulation, air valves, roof-hoods, dampers, fire dampers, silencers. The data represent a ductwork made of galvanized steel and polyethylene tubes. It includes air handling units mainly with heat recovery. System with central air handling units. Building without ground heat exchanger.; UUID: ea2047f4-5331-4555-b115-4b343401bb2c
This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.
Reference flow: 1 p of Disposal, ventilation system, Schulhaus Fallätsche (CH). All results are given per unit of the reference flow.
Transport to dismantling facilities, machines for handling in sorting plant, electricity demand for sorting plant, final disposal of waste material. Cut-off to recycling for metals.
Disposal to a sorting plant assumed. Metal pieces, copper in cables and electronic devices are recycled, plastic parts are incinerated, inert wastes (e.g. rock wool) are landfilled.
Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).
EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.
Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).
| Exchange | Type | Location / compartment | Amount | Unit | Uncertainty | Pedigree | GWP share (%) | Notes | |
|---|---|---|---|---|---|---|---|---|---|
| Disposal, building, polyethylene/polypropylene products, to final disposal | technosphere | CH | 2571.5 | kg | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 64.9 | █████████████ | |
| Disposal, ventilation unit 13000 m3/h, w. rotary heat exchanger | technosphere | CH | 1.577 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 10.9 | ██ | |
| Disposal, ventilation unit 6700 m3/h, w. rotary heat exchanger | technosphere | CH | 1.567 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 6.4 | █ | |
| Disposal, ventilation unit 6700 m3/h, w. cross plate heat excanger | technosphere | CH | 0.642 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 2.8 | █ | |
| Disposal, EI 60 fire insulation, 70mm, 120kg/m3, reinforced alumium foil | technosphere | CH | 885 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 2.2 | · | |
| Disposal, ventilation duct, steel, zinc coated, s= 0.62mm | technosphere | CH | 1257.8 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 1.9 | · | |
| Disposal, ventilation system, Schulhaus Fallätsche, various components | technosphere | CH | 1 | p | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 1.7 | · | |
| Disposal, ventilation duct, steel, zinc coated, s= 0.75mm | technosphere | CH | 1132.7 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 1.7 | · | |
| Disposal, silencer for ventilator unit 6700 m3/h, modular, Device | technosphere | CH | 8.836 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 1.3 | · | |
| Disposal, silencer for ventilator unit 13000 m3/h, modular | technosphere | CH | 6.308 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 1.3 | · | |
| Disposal, ventilation duct, steel, zinc coated, s= 1.0mm | technosphere | CH | 715.12 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 1.1 | · | |
| Disposal, thermal insulation, 60mm, 40kg/m3, reinforced alumium foil | technosphere | CH | 733 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 1.1 | · | |
| Disposal, ventilation duct, steel, zinc coated, s= 0.87mm | technosphere | CH | 481.45 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.8 | · | |
| Disposal, ventilation duct, steel, zinc coated, s= 1.25mm | technosphere | CH | 327.77 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.5 | · | |
| Disposal, spiral-seam duct, steel, zinc coated, s= 0.5mm | technosphere | CH | 169.76 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.5 | · | |
| Disposal, ventilation duct, steel, zinc coated, s= 1.5mm | technosphere | CH | 158.76 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.3 | · | |
| Disposal, spiral-seam duct, steel, zinc coated, s= 0.6mm | technosphere | CH | 99.436 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.3 | · | |
| Disposal, flexible duct, aluminum/PET, DN of 125 | technosphere | CH | 59.767 | m | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.1 | · | |
| Disposal, thermal insulation, 30mm, 40kg/m3, reinforced alumium foil | technosphere | CH | 98 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.1 | · |
19 of 19 direct exchanges carry a declared pedigree, 19 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 2.26 · completeness 4.0 · temporal 1.0 · geographical 1.0 · technological 1.0 · sample size 5.0.
| Field | As declared by the publisher |
|---|---|
| Data generator / entry / validation | data generator: Alex Primas (HSLU); data entry: Alex Primas (HSLU); validation (proof reading): Alex Primas (HSLU) |
| extrapolations | none |
| sampling procedure | Waste-specific calculation based on production input data |
| production volume | na |
| uncertainty adjustments | none |
| time period comment | Amount of material investigated in 2013. Disposal technology mix as used in late 1990ies |
None recorded.
Per 1 p. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.
| Impact category | Indicator | Unit | Result | 2.5 % | 97.5 % | GSD² |
|---|---|---|---|---|---|---|
| Acidification | Accumulated Exceedance (AE) | mol H+ eq | 1.68 | 1.501 | 3.245 | 1.5 |
| Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | 0.9844 | 0.7878 | 1.997 | 1.61 |
| Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | 1.202e+04 | 1.059e+04 | 1.446e+04 | 1.17 |
| Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | 0.1698 | 0.1498 | 0.2597 | 1.33 |
| Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | 1.202e+04 | 1.059e+04 | 1.446e+04 | 1.17 |
| EF-particulate Matter | Impact on human health | disease incidence | 1.068e-04 | 7.126e-05 | 2.155e-04 | 1.75 |
| Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | 1.925e+04 | 1.545e+04 | 3.143e+04 | 1.44 |
| Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | 79.23 | 69.75 | 150.8 | 1.51 |
| Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | 1.932e+04 | 1.553e+04 | 3.154e+04 | 1.44 |
| Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | 2.05 | 1.659 | 4.459 | 1.64 |
| Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | 0.797 | 0.144 | 24.18 | 14.5 |
| Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | 14.77 | 11.4 | 33.73 | 1.73 |
| Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | 4.353e-07 | 3.528e-07 | 1.975e-06 | 2.43 |
| Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | 1.050e-07 | 9.474e-08 | 1.628e-07 | 1.33 |
| Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | 5.403e-07 | 4.808e-07 | 2.110e-06 | 2.16 |
| Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | 2.350e-05 | 1.987e-05 | 1.117e-04 | 2.4 |
| Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | 8.006e-07 | 6.521e-07 | 1.235e-06 | 1.4 |
| Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | 2.430e-05 | 2.077e-05 | 1.123e-04 | 2.36 |
| Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | 159 | 61.33 | 975.6 | 4.16 |
| Land use | Soil quality index | pt (soil quality index) | 6447 | 415 | 1.499e+04 | — |
| Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | 2.040e-05 | 1.850e-05 | 3.371e-05 | 1.36 |
| Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | 5.457 | 4.403 | 11.41 | 1.62 |
| Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | 8894 | 8040 | 1.513e+04 | 1.37 |
| Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | 0.00116 | 0.00101 | 0.002359 | 1.53 |
| Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | 653.4 | -6.847e+04 | 3.792e+04 | — |
Climate change 1.202e+04 kg CO2 eq per p. Main contributors: Disposal, building, polyethylene/polypropylene products, to … 65 %; Disposal, ventilation unit 13000 m3/h, w. rotary heat exchan… 11 %; Disposal, ventilation unit 6700 m3/h, w. rotary heat exchang… 6 %; Disposal, ventilation unit 6700 m3/h, w. cross plate heat ex… 3 %; Disposal, EI 60 fire insulation, 70mm, 120kg/m3, reinforced … 2 %; Disposal, ventilation duct, steel, zinc coated, s= 0.62mm 2 %.
Direct exchanges dominating climate change: Disposal, building, polyethylene/polypropylene products, to … 65 %; Disposal, ventilation unit 13000 m3/h, w. rotary heat exchan… 11 %; Disposal, ventilation unit 6700 m3/h, w. rotary heat exchang… 6 %; Disposal, ventilation unit 6700 m3/h, w. cross plate heat ex… 3 %; Disposal, EI 60 fire insulation, 70mm, 120kg/m3, reinforced … 2 %; Disposal, ventilation duct, steel, zinc coated, s= 0.62mm 2 %. Most sensitive exchanges (Section 6.3): Disposal, building, polyethylene/polypropylene products, to final disposal [CH] (-12.3 / +15.2 %); Disposal, ventilation unit 13000 m3/h, w. rotary heat exchanger [CH] (-2.2 / +2.8 %); Disposal, ventilation unit 6700 m3/h, w. rotary heat exchanger [CH] (-1.3 / +1.6 %).
The publisher publishes no LCIA result for this dataset; the closure check of Section 7 is the recalculation test.
One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.
| Exchange | Base | Low / high | Range | Δ GWP100 (%) | Δ other categories (max %) |
|---|---|---|---|---|---|
| Disposal, building, polyethylene/polypropylene products, to final disposal [CH] | 2572 kg | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -12.3 / +15.2 | 15.2 (Climate change-Fossil) |
| Disposal, ventilation unit 13000 m3/h, w. rotary heat exchanger [CH] | 1.577 p | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -2.2 / +2.8 | 11.1 (Ecotoxicity, freshwater_inorganics) |
| Disposal, ventilation unit 6700 m3/h, w. rotary heat exchanger [CH] | 1.567 p | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -1.3 / +1.6 | 5.9 (Ecotoxicity, freshwater_inorganics) |
| Disposal, ventilation unit 6700 m3/h, w. cross plate heat excanger [CH] | 0.642 p | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -0.6 / +0.7 | 2.5 (Ecotoxicity, freshwater_inorganics) |
| Disposal, EI 60 fire insulation, 70mm, 120kg/m3, reinforced alumium foil [CH] | 885 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.4 / +0.5 | 15.8 (Eutrophication, freshwater) |
| Disposal, ventilation duct, steel, zinc coated, s= 0.62mm [CH] | 1258 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.4 / +0.4 | 2.3 (Ionising radiation, human health) |
| Disposal, ventilation system, Schulhaus Fallätsche, various components [CH] | 1 p | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.3 / +0.4 | 1.9 (Ionising radiation, human health) |
| Disposal, ventilation duct, steel, zinc coated, s= 0.75mm [CH] | 1133 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.3 / +0.4 | 2.5 (Ionising radiation, human health) |
| Disposal, silencer for ventilator unit 6700 m3/h, modular, Device [CH] | 8.836 p | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -0.3 / +0.3 | 1.4 (Eutrophication marine) |
| Disposal, silencer for ventilator unit 13000 m3/h, modular [CH] | 6.308 p | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -0.3 / +0.3 | 1.4 (Eutrophication marine) |
| Disposal, ventilation duct, steel, zinc coated, s= 1.0mm [CH] | 715.1 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.2 / +0.3 | 2.1 (Ionising radiation, human health) |
| Disposal, thermal insulation, 60mm, 40kg/m3, reinforced alumium foil [CH] | 733 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.2 / +0.3 | 3.7 (Eutrophication, freshwater) |
| Disposal, ventilation duct, steel, zinc coated, s= 0.87mm [CH] | 481.4 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.1 / +0.2 | 1.2 (Ionising radiation, human health) |
| Disposal, ventilation duct, steel, zinc coated, s= 1.25mm [CH] | 327.8 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.1 / +0.1 | 1.2 (Ionising radiation, human health) |
| Disposal, spiral-seam duct, steel, zinc coated, s= 0.5mm [CH] | 169.8 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.1 / +0.1 | 0.2 (Ionising radiation, human health) |
Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.
No other location of this dataset in the graph.
GWP100 1.202e+04 kg CO2 eq per p (95 % interval 1.059e+04–1.446e+04). Dominant contributors: Disposal, building, polyethylene/polypropylene products, to … 65 %; Disposal, ventilation unit 13000 m3/h, w. rotary heat exchan… 11 %; Disposal, ventilation unit 6700 m3/h, w. rotary heat exchang… 6 %; Disposal, ventilation unit 6700 m3/h, w. cross plate heat ex… 3 %; Disposal, EI 60 fire insulation, 70mm, 120kg/m3, reinforced … 2 %; Disposal, ventilation duct, steel, zinc coated, s= 0.62mm 2 %. Most sensitive: Disposal, building, polyethylene/polypropylene products, to final disposal [CH] (-12.3 / +15.2 %); Disposal, ventilation unit 13000 m3/h, w. rotary heat exchanger [CH] (-2.2 / +2.8 %); Disposal, ventilation unit 6700 m3/h, w. rotary heat exchanger [CH] (-1.3 / +1.6 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.
| Item | Status | Detail |
|---|---|---|
| reference flow | PASS | production amount 1.0 p |
| closure: sum of direct contributions = dataset score (all 25 categories) | PASS | largest relative gap 3.9e-16 |
| every technosphere input of the EcoSpold delivery is in the graph | PASS | all present (bafu_links_check.py) |
| uncertainty declared on the direct exchanges | PASS | 19/19 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values |
| Monte Carlo 95 % interval contains the deterministic score | PASS | 1.202e+04 in [1.059e+04, 1.446e+04] |
| time period declared | PASS | 2014-01/2014-12 |
| geography is a known location code | PASS | CH |
| sources cited | PASS | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them |
BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.
To suggest a correction or a dataset that does not exist yet, use Propose a dataset.