Table of Contents

Electricity, hydropower, at pumped storage power plant — FI

Dataset documentation and final control (tdc-doc, imported mode)
Open this dataset in OpenData

Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Electricity, hydropower, at pumped storage power plant [FI], per 1 kWh. EF v3.1 climate change 0.1643 kg CO2 eq (Monte Carlo 95 % interval 0.1505–0.2083). Main contributors: Electricity, high voltage, at grid 96 %; Carbon Dioxide (land Use Change) 4 %. Status: final control passed.
Item Value
Dataset name Electricity, hydropower, at pumped storage power plant
Dataset UUID / graph id ea665bb9-38d7-3895-a65a-f32f262b68dc / activity:electricity_hydropower_at_pumped_storage_power_plant__fi
Reference product, unit Electricity, hydropower, at pumped storage power plant, 1 kWh
Location FI — Data were extrapolated from the average Swiss pumped storage hydropower plant.
Time period 1945-01/2000-12
Category electricity by fuel / hydro\pumping storage
Source database BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1
Publisher Swiss Federal Office for the Environment (FOEN/BAFU)
Background database BAFU 2026 v1 (graph bafuquery-db)
LCIA method EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix)
Status final control passed
Documented by tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17

Introduction

This study adresses Swiss dams only. The data have been applied for an extrapolation to preliminary describe dam-mixes in non-alpine countries. Considering the difficulty to clearly seperate within the Swiss dams system for some of the dams function for normal electricity generation from pumping storage, the same basic information has been used for the modules describing the two functions. A representative sample of Swiss dams with a height of more than 30 metres is taken into account for calculating the numbers. Lifetime is assumed to be 150 years. The efficiency of the pumps is assumed to be 70%. The results of this module cannot be applied to describe a single unit.; UUID: ea665bb9-38d7-3895-a65a-f32f262b68dc

This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.

Goal and scope

Function, functional unit and reference flow

Reference flow: 1 kWh of Electricity, hydropower, at pumped storage power plant (FI). All results are given per unit of the reference flow.

System boundary

Includes the conversion of electricity from domestic high voltage grid to potential energy by pumping water up to the reservoir and generation of peak-load power when water flows back down to the turbine (reverse mode). The module has the same structure as the module for operation for reservoir plants.

Technology

The module describes average installed technology with an efficiency of 70% (best technology has 74%).

Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).

LCIA method

EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.

Life cycle inventory

Inventory table

Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).

Exchange Type Location / compartment Amount Unit Uncertainty Pedigree GWP share (%) Notes
Electricity, high voltage, at grid technosphere FI 1.43 kWh lognormal, GSD² 1.05 — 96.3 ███████████████████
Reservoir hydropower plant, non alpine regions technosphere RER 3.9000e-13 p lognormal, GSD² 1.5 — 0.0 ·
Disposal, used mineral oil, 10% water, to hazardous waste incineration technosphere CH 7.0000e-06 kg none declared: tdc-doc default ±50 % — 0.0 ·
Lubricating oil, at plant technosphere RER 7.0000e-06 kg lognormal, GSD² 1.8 — 0.0 ·
Carbon Dioxide (land Use Change) elementary air/Medium stack, <150 meters / Rural (<… 0.006 kg lognormal, GSD² 2 — 3.7 █
Turbine water, FI elementary natural resource [FI] 8.1 m3 lognormal, GSD² 1.05 — 0.0 ·
To industrial area elementary natural resource 2.3000e-06 m2 lognormal, GSD² 3 — 0.0 ·
To lake, artificial elementary natural resource 2.2800e-04 m2 lognormal, GSD² 3 — 0.0 ·
Volume Occupied, Reservoir elementary natural resource 0.15 m3.a lognormal, GSD² 3 — 0.0 ·
Lake, artificial elementary natural resource 0.035 m2.a lognormal, GSD² 3 — 0.0 ·
From unspecified elementary natural resource 2.3000e-04 m2 lognormal, GSD² 3 — 0.0 ·
Waste Heat elementary water/River 1.55 MJ lognormal, GSD² 1.05 — 0.0 ·
Water, FI elementary water/Unknown [FI] 8.1 m3 lognormal, GSD² 2.52 — 0.0 ·

Data quality

0 of 13 direct exchanges carry a declared pedigree, 12 carry a distribution.

Field As declared by the publisher
Data generator / entry / validation data generator: Christian Bauer (PSI); data entry: Christian Bauer (PSI); validation (proof reading): Christian Bauer (PSI)
extrapolations see Geography/Text
sampling procedure literature
production volume na
uncertainty adjustments Data may not be representative for specific national conditions. The uncertainities calculated for the Swiss conditions have been somewhat increased.
validation details Proof reading validation: passed; Other validation: none;

Data gaps, proxies and assumptions

Item Class Value used Reason Effect
1 exchange(s) without declared uncertainty uncertainty fixed in the Monte Carlo the publisher declares no distribution ±50 % in the sensitivity check (Section 6.3)

Life cycle impact assessment (EF v3.1)

Per 1 kWh. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.

Impact category Indicator Unit Result 2.5 % 97.5 % GSD²
Acidification Accumulated Exceedance (AE) mol H+ eq 4.137e-04 3.848e-04 5.834e-04 1.23
Climate change-Biogenic Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.01016 0.003908 0.02926 2.84
Climate change-Fossil Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.1481 0.1366 0.1846 1.17
Climate change-Land use and land use change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.00602 0.002989 0.01197 2.04
Climate change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.1643 0.1505 0.2083 1.18
EF-particulate Matter Impact on human health disease incidence 9.642e-09 7.266e-09 1.774e-08 1.57
Ecotoxicity, freshwater_inorganics Comparative Toxic Unit for ecosystems (CTUe) CTUe 0.4916 0.3974 1.215 1.76
Ecotoxicity, freshwater_organics Comparative Toxic Unit for ecosystems (CTUe) CTUe 0.008888 0.007002 0.02636 1.97
Ecotoxicity, freshwater Comparative Toxic Unit for ecosystems (CTUe) CTUe 0.5005 0.4073 1.24 1.75
Eutrophication marine Fraction of nutrients reaching marine end compartment (N) kg N eq 1.705e-04 1.486e-04 2.610e-04 1.32
Eutrophication, freshwater Fraction of nutrients reaching freshwater end compartment (P) kg P eq 3.856e-05 2.508e-05 1.376e-04 2.4
Eutrophication, terrestrial Accumulated Exceedance (AE) mol N eq 0.001421 0.001235 0.002347 1.36
Human toxicity, cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 2.550e-11 2.433e-11 8.056e-11 1.86
Human toxicity, cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 2.909e-10 1.854e-10 5.100e-10 1.64
Human toxicity, cancer Comparative Toxic Unit for human (CTUh) CTUh 3.164e-10 2.254e-10 5.520e-10 1.57
Human toxicity, non-cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 1.882e-09 1.625e-09 5.975e-09 1.91
Human toxicity, non-cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 6.528e-11 5.530e-11 1.168e-10 1.45
Human toxicity, non-cancer Comparative Toxic Unit for human (CTUh) CTUh 1.947e-09 1.702e-09 6.075e-09 1.88
Ionising radiation, human health Human exposure efficiency relative to U235 kBq U235 eq 0.7206 0.1924 4.535 5.17
Land use Soil quality index pt (soil quality index) 11.89 6.701 21.13 1.8
Ozone depletion Ozone Depletion Potential (ODP) kg CFC-11 eq 1.714e-08 9.186e-09 3.579e-08 1.98
Photochemical ozone formation - human health Tropospheric ozone concentration increase kg NMVOC eq 4.769e-04 4.234e-04 7.447e-04 1.33
Resource use, fossils Abiotic resource depletion fossil fuels (ADP-fossil) MJ 8.488 7.105 11.39 1.27
Resource use, minerals and metals Abiotic resource depletion (ADP ultimate reserve) kg Sb eq 2.409e-07 2.060e-07 4.733e-07 1.55
Water use User deprivation potential (deprivation-weighted water consumption) m3 world eq deprived 0.09046 -194.4 96.35 —

Climate change 0.1643 kg CO2 eq per kWh. Main contributors: Electricity, high voltage, at grid 96 %; Carbon Dioxide (land Use Change) 4 %.

Interpretation

Significant issues

Direct exchanges dominating climate change: Electricity, high voltage, at grid 96 %; Carbon Dioxide (land Use Change) 4 %. Most sensitive exchanges (Section 6.3): Electricity, high voltage, at grid [FI] (-4.5 / +4.7 %); Carbon Dioxide (land Use Change) [air/Medium stack, <150 meters / Rural (<1000 people/squa… (-1.8 / +3.6 %); Reservoir hydropower plant, non alpine regions [RER] (-0.0 / +0.0 %).

Independent recalculation

Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh:

Category Graph Published Graph / published
Acidification 4.137e-04 5.749e-04 0.720
Climate change-Biogenic 0.01016 0.01016 1.000
Climate change-Fossil 0.1481 0.1481 1.000
Climate change-Land use and land use change 0.00602 0.00602 1.000
Climate change 0.1643 0.1643 1.000
EF-particulate Matter 9.642e-09 9.642e-09 1.000
Ecotoxicity, freshwater_inorganics 0.4916 0.5237 0.939
Ecotoxicity, freshwater_organics 0.008888 0.008744 1.016
Ecotoxicity, freshwater 0.5005 0.5324 0.940
Eutrophication marine 1.705e-04 1.704e-04 1.001
Eutrophication, freshwater 3.856e-05 3.856e-05 1.000
Eutrophication, terrestrial 0.001421 0.001653 0.860
Human toxicity, cancer_inorganics 2.550e-11 2.322e-11 1.098
Human toxicity, cancer_organics 2.909e-10 2.909e-10 1.000
Human toxicity, cancer 3.164e-10 3.142e-10 1.007
Human toxicity, non-cancer_inorganics 1.882e-09 1.783e-09 1.055
Human toxicity, non-cancer_organics 6.528e-11 6.526e-11 1.000
Human toxicity, non-cancer 1.947e-09 1.849e-09 1.053
Ionising radiation, human health 0.7206 0.7206 1.000
Land use 11.89 9.36 1.271
Ozone depletion 1.714e-08 1.713e-08 1.000
Photochemical ozone formation - human health 4.769e-04 4.769e-04 1.000
Resource use, fossils 8.488 8.851 0.959
Resource use, minerals and metals 2.409e-07 2.295e-07 1.050
Water use 0.09046 0.1007 0.899
Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like.
Also published by BAFU for this dataset: IPCC 2021 GWP100 0.1643 kg CO2 eq; Ecological Scarcity
2021 total 543.9 UBP.

Sensitivity check

One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.

Exchange Base Low / high Range Δ GWP100 (%) Δ other categories (max %)
Electricity, high voltage, at grid [FI] 1.43 kWh ×0.953 / ×1.05 lognormal, GSD² 1.05 -4.5 / +4.7 5.2 (Land use)
Carbon Dioxide (land Use Change) [air/Medium stack, <150 meters / Rural (<1000 people/squa… 0.006 kg ×0.507 / ×1.97 lognormal, GSD² 2 -1.8 / +3.6 96.9 (Climate change-Land use and land use change)
Reservoir hydropower plant, non alpine regions [RER] 3.900e-13 p ×0.672 / ×1.49 lognormal, GSD² 1.5 -0.0 / +0.0 0.1 (Resource use, minerals and metals)
Disposal, used mineral oil, 10% water, to hazardous waste incineration [CH] 7.000e-06 kg ×0.5 / ×1.5 none declared: tdc-doc default ±50 % -0.0 / +0.0 0.0 (Climate change-Fossil)
Lubricating oil, at plant [RER] 7.000e-06 kg ×0.562 / ×1.78 lognormal, GSD² 1.8 -0.0 / +0.0 0.1 (Ecotoxicity, freshwater_organics)
Turbine water, FI [natural resource [FI]] 8.1 m3 ×0.953 / ×1.05 lognormal, GSD² 1.05 -0.0 / +0.0 850.8 (Water use)
To industrial area [natural resource] 2.300e-06 m2 ×0.341 / ×2.93 lognormal, GSD² 3 -0.0 / +0.0 0.2 (Land use)
From unspecified [natural resource] 2.300e-04 m2 ×0.341 / ×2.93 lognormal, GSD² 3 -0.0 / +0.0 11.0 (Land use)
Water, FI [water/Unknown [FI]] 8.1 m3 ×0.404 / ×2.47 lognormal, GSD² 2.52 -0.0 / +0.0 25596.4 (Water use)

Uncertainty analysis

Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.

Comparison with other data

Source Scope Value This dataset Ratio Note
bafu Electricity, hydropower, at pumped storage power plant [SE] 0.06587 kg CO2 eq 0.1643 2.49 same dataset name, other location
bafu Electricity, hydropower, at pumped storage power plant [NO] 0.08292 kg CO2 eq 0.1643 1.98 same dataset name, other location
bafu Electricity, hydropower, at pumped storage power plant [FR] 0.09259 kg CO2 eq 0.1643 1.77 same dataset name, other location
bafu Electricity, hydropower, at pumped storage power plant [CH] 0.1213 kg CO2 eq 0.1643 1.35 same dataset name, other location
bafu Electricity, hydropower, at pumped storage power plant [NZ] 0.1672 kg CO2 eq 0.1643 0.98 same dataset name, other location
bafu Electricity, hydropower, at pumped storage power plant [RS] 1.107 kg CO2 eq 0.1643 0.15 same dataset name, other location
bafu Electricity, hydropower, at pumped storage power plant [CS] 1.112 kg CO2 eq 0.1643 0.15 same dataset name, other location
bafu Electricity, hydropower, at pumped storage power plant [IN] 1.204 kg CO2 eq 0.1643 0.14 same dataset name, other location
bafu Electricity, hydropower, at pumped storage power plant [BA] 1.284 kg CO2 eq 0.1643 0.13 same dataset name, other location
bafu Electricity, hydropower, at pumped storage power plant [ZA] 1.307 kg CO2 eq 0.1643 0.13 same dataset name, other location

Conclusions and limitations

GWP100 0.1643 kg CO2 eq per kWh (95 % interval 0.1505–0.2083). Dominant contributors: Electricity, high voltage, at grid 96 %; Carbon Dioxide (land Use Change) 4 %. Most sensitive: Electricity, high voltage, at grid [FI] (-4.5 / +4.7 %); Carbon Dioxide (land Use Change) [air/Medium stack, <150 meters / Rural (<1000 people/squa… (-1.8 / +3.6 %); Reservoir hydropower plant, non alpine regions [RER] (-0.0 / +0.0 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.

Final control

Item Status Detail
reference flow PASS production amount 1.0 kWh
closure: sum of direct contributions = dataset score (all 25 categories) PASS largest relative gap 2.3e-16
independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh (climate change) PASS graph / published = 1; categories within ±5 %: 16/25
every technosphere input of the EcoSpold delivery is in the graph PASS all present (bafu_links_check.py)
uncertainty declared on the direct exchanges PASS 12/13 exchanges carry a distribution (92 %); the others enter the Monte Carlo as fixed values
Monte Carlo 95 % interval contains the deterministic score PASS 0.1643 in [0.1505, 0.2083]
time period declared PASS 1945-01/2000-12
geography is a known location code PASS FI
sources cited PASS 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them

References

  1. Bolliger, R., Bauer, Ch. (2007) Wasserkraft. Sachbilanzen von Energiesystemen. Final report No. 6 ecoinvent data v2.0. Editors: Dones R.. Volume: 6. Swiss Centre for LCI, PSI. Dübendorf and Villigen, CH. Type: Measurement on site Source: CD-ROM First author: Bolliger, R. Other authors: Bauer, Ch. Year: 2007 Name of editors: Dones R. Title of anthology: Sachbilanzen von Energiesystemen. Final repor… — published source; as declared by BAFU (not found in OpenAlex/Crossref)
  2. Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — database; dataset citation
  3. International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva.
  4. Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. (tdc-doc method reference; title, version and year to verify against the user's copy)
  5. European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra.
  6. Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236

Annex — licence and terms of use

BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.


To suggest a correction or a dataset that does not exist yet, use Propose a dataset.