Dataset documentation and final control (tdc-doc, imported mode)
Open this dataset in OpenData
Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Ventilation system, Geschäftshaus C, Esslingen, special components [CH], per 1 p. EF v3.1 climate change 300.9 kg CO2 eq (Monte Carlo 95 % interval 258.1–511.7). Main contributors: Cable, connector for computer, without plugs, at plant 38 %; Fan, at plant 31 %; Medium density fibreboard, uncoated, at plant 17 %; Acrylonitrile-butadiene-styrene copolymer, ABS, at plant 7 %; Transformer, low voltage use, at plant 4 %; Steel, converter, unalloyed, at plant 2 %. Status: final control passed.
| Item | Value |
|---|---|
| Dataset name | Ventilation system, Geschäftshaus C, Esslingen, special components |
| Dataset UUID / graph id | ee4e6217-09f5-3e62-b94a-1d169c650f69 / activity:ventilation_system_geschäftshaus_c_esslingen_special_components__ch |
| Reference product, unit | Ventilation system, Geschäftshaus C, Esslingen, special components, 1 p |
| Location | CH |
| Time period | 2014-01/2014-12 |
| Category | ventilation / production of components |
| Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 |
| Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) |
| Background database | BAFU 2026 v1 (graph bafuquery-db) |
| LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) |
| Status | final control passed |
| Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 |
Production of special components of a ventilation system for an office building with offices only (no kitchen, restaurant or car park). The inventory is based on a building with a total heated gross floor area of 2621 m2 and a total nominal air flow of 4000 m3/h, total weight of the components: 121 kg/Unit, building with a specific air flow rate of 1.5 m3/h per m2 heated gross floor area. Data from call of bid including decental ventilation units between circulation area and offices. Components including fans, wiring and transformer but without surrounding light-weight wall.; UUID: ee4e6217-09f5-3e62-b94a-1d169c650f69
This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.
Reference flow: 1 p of Ventilation system, Geschäftshaus C, Esslingen, special components (CH). All results are given per unit of the reference flow.
Materials used for the production. Energy use for the different production steps and for heating the production building. Transport of raw materials to the plant. Estimation for infrastructure of the production site included.
Technology, materials and components used for ventilation systems in commercial and public buildings
Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).
EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.
Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).
| Exchange | Type | Location / compartment | Amount | Unit | Uncertainty | Pedigree | GWP share (%) | Notes | |
|---|---|---|---|---|---|---|---|---|---|
| Cable, connector for computer, without plugs, at plant | technosphere | GLO | 338.36 | m | lognormal, GSD² 1.34 | (3,4,1,1,3,5) | 38.4 | ████████ | |
| Fan, at plant | technosphere | GLO | 10 | kg | lognormal, GSD² 1.34 | (3,4,1,1,3,5) | 30.8 | ██████ | |
| Medium density fibreboard, uncoated, at plant | technosphere | RER | 0.098077 | m3 | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 16.9 | ███ | |
| Acrylonitrile-butadiene-styrene copolymer, ABS, at plant | technosphere | RER | 4.5 | kg | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 6.8 | █ | |
| Transformer, low voltage use, at plant | technosphere | GLO | 3.6 | kg | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 3.6 | █ | |
| Steel, converter, unalloyed, at plant | technosphere | RER | 2.52 | kg | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 2.0 | · | |
| Sheet rolling, steel | technosphere | RER | 4 | kg | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 0.5 | · | |
| Zinc coating, coils | technosphere | RER | 0.34 | m2 | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 0.5 | · | |
| Steel, electric, un- and low-alloyed, at plant | technosphere | RER | 1.48 | kg | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 0.3 | · | |
| Transport, freight, lorry, 16t-32t gross weight, fleet average | technosphere | CH | 4.25 | tkm | lognormal, GSD² 2.14 | (4,5,1,1,1,5) | 0.2 | · | |
| Transport, freight, rail | technosphere | RER | 18.6 | tkm | lognormal, GSD² 2.14 | (4,5,1,1,1,5) | 0.1 | · |
11 of 11 direct exchanges carry a declared pedigree, 11 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 3.18 · completeness 4.18 · temporal 1.0 · geographical 1.0 · technological 1.36 · sample size 5.0.
| Field | As declared by the publisher |
|---|---|
| Data generator / entry / validation | data generator: Alex Primas (HSLU); data entry: Alex Primas (HSLU); validation (proof reading): Alex Primas (HSLU) |
| extrapolations | none |
| sampling procedure | Data from call of bids for a ventilation system of a specific building used. Data completed with information from literature and from manufacturers |
| production volume | na |
| uncertainty adjustments | none |
| time period comment | Amount of material investigated in 2013. Process information partly from 2003 to 2012 |
None recorded.
Per 1 p. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.
| Impact category | Indicator | Unit | Result | 2.5 % | 97.5 % | GSD² |
|---|---|---|---|---|---|---|
| Acidification | Accumulated Exceedance (AE) | mol H+ eq | 5.687 | 4.113 | 9.453 | 1.54 |
| Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | 1.004 | 0.6696 | 2.531 | 1.98 |
| Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | 299.7 | 257.2 | 509.9 | 1.41 |
| Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | 0.1381 | 0.1089 | 0.273 | 1.61 |
| Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | 300.9 | 258.1 | 511.7 | 1.41 |
| EF-particulate Matter | Impact on human health | disease incidence | 2.226e-05 | 1.979e-05 | 3.978e-05 | 1.42 |
| Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | 2772 | 2360 | 7481 | 1.75 |
| Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | 72.47 | 61.47 | 152.1 | 1.58 |
| Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | 2844 | 2431 | 7603 | 1.74 |
| Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | 0.4466 | 0.3741 | 0.8626 | 1.57 |
| Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | 1.514 | 0.8613 | 10.16 | 3.58 |
| Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | 5.651 | 4.69 | 10.09 | 1.47 |
| Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | 7.274e-07 | 4.638e-07 | 2.514e-06 | 2.31 |
| Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | 6.511e-07 | 4.274e-07 | 1.481e-06 | 1.87 |
| Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | 1.378e-06 | 1.077e-06 | 3.393e-06 | 1.78 |
| Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | 6.966e-05 | 4.254e-05 | 2.378e-04 | 2.49 |
| Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | 3.648e-06 | 1.872e-06 | 7.924e-06 | 2.08 |
| Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | 7.331e-05 | 4.616e-05 | 2.421e-04 | 2.42 |
| Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | 62.95 | 23.98 | 434.8 | 4.38 |
| Land use | Soil quality index | pt (soil quality index) | 1.071e+04 | 8828 | 1.733e+04 | 1.38 |
| Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | 2.190e-05 | 1.620e-05 | 4.298e-05 | 1.64 |
| Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | 1.789 | 1.536 | 3.045 | 1.42 |
| Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | 5180 | 4523 | 8758 | 1.39 |
| Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | 0.04979 | 0.03175 | 0.1064 | 1.84 |
| Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | 44.55 | -1.290e+05 | 6.081e+04 | — |
Climate change 300.9 kg CO2 eq per p. Main contributors: Cable, connector for computer, without plugs, at plant 38 %; Fan, at plant 31 %; Medium density fibreboard, uncoated, at plant 17 %; Acrylonitrile-butadiene-styrene copolymer, ABS, at plant 7 %; Transformer, low voltage use, at plant 4 %; Steel, converter, unalloyed, at plant 2 %.
Direct exchanges dominating climate change: Cable, connector for computer, without plugs, at plant 38 %; Fan, at plant 31 %; Medium density fibreboard, uncoated, at plant 17 %; Acrylonitrile-butadiene-styrene copolymer, ABS, at plant 7 %; Transformer, low voltage use, at plant 4 %; Steel, converter, unalloyed, at plant 2 %. Most sensitive exchanges (Section 6.3): Cable, connector for computer, without plugs, at plant [GLO] (-9.6 / +12.7 %); Fan, at plant [GLO] (-7.7 / +10.2 %); Medium density fibreboard, uncoated, at plant [RER] (-3.4 / +4.3 %).
The publisher publishes no LCIA result for this dataset; the closure check of Section 7 is the recalculation test.
One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.
| Exchange | Base | Low / high | Range | Δ GWP100 (%) | Δ other categories (max %) |
|---|---|---|---|---|---|
| Cable, connector for computer, without plugs, at plant [GLO] | 338.4 m | ×0.751 / ×1.33 | lognormal, GSD² 1.34 | -9.6 / +12.7 | 29.8 (Human toxicity, non-cancer_inorganics) |
| Fan, at plant [GLO] | 10 kg | ×0.751 / ×1.33 | lognormal, GSD² 1.34 | -7.7 / +10.2 | 20.4 (Resource use, minerals and metals) |
| Medium density fibreboard, uncoated, at plant [RER] | 0.09808 m3 | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -3.4 / +4.3 | 22.5 (Human toxicity, cancer_organics) |
| Acrylonitrile-butadiene-styrene copolymer, ABS, at plant [RER] | 4.5 kg | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -1.4 / +1.7 | 2.1 (Resource use, fossils) |
| Transformer, low voltage use, at plant [GLO] | 3.6 kg | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -0.7 / +0.9 | 5.3 (Ecotoxicity, freshwater_organics) |
| Steel, converter, unalloyed, at plant [RER] | 2.52 kg | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -0.4 / +0.5 | 0.5 (Climate change-Fossil) |
| Transport, freight, lorry, 16t-32t gross weight, fleet average [CH] | 4.25 tkm | ×0.474 / ×2.11 | lognormal, GSD² 2.14 | -0.1 / +0.3 | 0.3 (Photochemical ozone formation - human health) |
| Sheet rolling, steel [RER] | 4 kg | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -0.1 / +0.1 | 0.2 (Water use) |
| Zinc coating, coils [RER] | 0.34 m2 | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -0.1 / +0.1 | 2.3 (Eutrophication, terrestrial) |
| Transport, freight, rail [RER] | 18.6 tkm | ×0.474 / ×2.11 | lognormal, GSD² 2.14 | -0.1 / +0.1 | 0.5 (Ionising radiation, human health) |
| Steel, electric, un- and low-alloyed, at plant [RER] | 1.48 kg | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -0.1 / +0.1 | 0.2 (Ionising radiation, human health) |
Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.
No other location of this dataset in the graph.
GWP100 300.9 kg CO2 eq per p (95 % interval 258.1–511.7). Dominant contributors: Cable, connector for computer, without plugs, at plant 38 %; Fan, at plant 31 %; Medium density fibreboard, uncoated, at plant 17 %; Acrylonitrile-butadiene-styrene copolymer, ABS, at plant 7 %; Transformer, low voltage use, at plant 4 %; Steel, converter, unalloyed, at plant 2 %. Most sensitive: Cable, connector for computer, without plugs, at plant [GLO] (-9.6 / +12.7 %); Fan, at plant [GLO] (-7.7 / +10.2 %); Medium density fibreboard, uncoated, at plant [RER] (-3.4 / +4.3 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.
| Item | Status | Detail |
|---|---|---|
| reference flow | PASS | production amount 1.0 p |
| closure: sum of direct contributions = dataset score (all 25 categories) | PASS | largest relative gap 3.1e-16 |
| every technosphere input of the EcoSpold delivery is in the graph | PASS | all present (bafu_links_check.py) |
| uncertainty declared on the direct exchanges | PASS | 11/11 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values |
| Monte Carlo 95 % interval contains the deterministic score | PASS | 300.9 in [258.1, 511.7] |
| time period declared | PASS | 2014-01/2014-12 |
| geography is a known location code | PASS | CH |
| sources cited | PASS | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them |
BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.
To suggest a correction or a dataset that does not exist yet, use Propose a dataset.