Table of Contents

Solar system, 81 m2 Cu flat plate collector, multiple dwelling, hot water — CH

Dataset documentation and final control (tdc-doc, imported mode)
Open this dataset in OpenData

Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Solar system, 81 m2 Cu flat plate collector, multiple dwelling, hot water [CH], per 1 p. EF v3.1 climate change 9100 kg CO2 eq (Monte Carlo 95 % interval 5392–3.102e+04). Main contributors: Flat plate collector, copper absorber, at plant 53 %; Transport, freight, lorry, 3.5t gross weight, fleet average 21 %; Heat storage 2000l, at plant 13 %; Expansion vessel 80l, at plant 2 %; Aluminium, production mix, wrought alloy, at plant 2 %; Copper, at regional storage 2 %. Status: final control passed.
Item Value
Dataset name Solar system, 81 m2 Cu flat plate collector, multiple dwelling, hot water
Dataset UUID / graph id ee6e5f3b-86aa-3e09-b5fb-96b6592dc77c / activity:solar_system_81_m2_cu_flat_plate_collector_multiple_dwelling_hot_water__ch
Reference product, unit Solar system, 81 m2 Cu flat plate collector, multiple dwelling, hot water, 1 p
Location CH
Time period 2000-01/2010-12
Category heat / solar\infrastructure
Source database BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1
Publisher Swiss Federal Office for the Environment (FOEN/BAFU)
Background database BAFU 2026 v1 (graph bafuquery-db)
LCIA method EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix)
Status final control passed
Documented by tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17

Introduction

Solar system with a flat plate collector on a multiple family dwelling for hot water. 25 years life time, 141 m pipe length and 4200 l heat storage. ; UUID: ee6e5f3b-86aa-3e09-b5fb-96b6592dc77c

This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.

Goal and scope

Function, functional unit and reference flow

Reference flow: 1 p of Solar system, 81 m2 Cu flat plate collector, multiple dwelling, hot water (CH). All results are given per unit of the reference flow.

System boundary

Production and disposal of a complete solar system (excluding auxiliary heating). Including different components, heat exchange fluid, warm water pipes, transports of parts to CH, and delivery with a van.

Technology

Solar collector system for hot water installed on the roof of a house.

Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).

LCIA method

EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.

Life cycle inventory

Inventory table

Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).

Exchange Type Location / compartment Amount Unit Uncertainty Pedigree GWP share (%) Notes
Flat plate collector, copper absorber, at plant technosphere CH 81 m2 lognormal, GSD² 4.81 — 52.6 ███████████
Transport, freight, lorry, 3.5t gross weight, fleet average technosphere CH 1782 tkm lognormal, GSD² 3.79 (3,5,3,1,1,5) 21.1 ████
Heat storage 2000l, at plant technosphere CH 1.3587 p lognormal, GSD² 4.81 — 13.5 ███
Expansion vessel 80l, at plant technosphere CH 5 p lognormal, GSD² 4.81 — 2.5 ·
Aluminium, production mix, wrought alloy, at plant technosphere RER 41.759 kg lognormal, GSD² 3.07 — 2.3 ·
Copper, at regional storage technosphere RER 127.07 kg lognormal, GSD² 3.07 — 2.2 ·
Propylene glycol, liquid, at plant technosphere RER 47.687 kg lognormal, GSD² 3.07 — 1.5 ·
Treatment, heat carrier liquid, 40% C3H8O2, to wastewater treatment, class 2 technosphere CH 0.12894 m3 lognormal, GSD² 3.07 — 1.3 ·
Pump 40W, at plant technosphere CH 13.611 p lognormal, GSD² 4.81 — 1.1 ·
Rock wool, packed, at plant technosphere CH 77.076 kg lognormal, GSD² 3.07 — 1.0 ·
Drawing of pipes, steel technosphere RER 127.07 kg lognormal, GSD² 3.12 — 0.6 ·
Sheet rolling, aluminium technosphere RER 41.759 kg lognormal, GSD² 3.07 — 0.2 ·
Powder coating, aluminium sheet technosphere RER 2.088 m2 lognormal, GSD² 3.07 — 0.1 ·
Transport, freight, rail technosphere RER 224.91 tkm lognormal, GSD² 3.76 — 0.0 ·
Transport, freight, lorry, 16t-32t gross weight, fleet average technosphere CH 18.742 tkm lognormal, GSD² 3.76 — 0.0 ·
Water, completely softened, at plant technosphere RER 81.25 kg lognormal, GSD² 3.07 — 0.0 ·

Data quality

1 of 16 direct exchanges carry a declared pedigree, 16 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 3.0 · completeness 5.0 · temporal 3.0 · geographical 1.0 · technological 1.0 · sample size 5.0.

Field As declared by the publisher
Data generator / entry / validation data generator: Matthias Stucki (ZHAW); data entry: Matthias Stucki (ZHAW); validation (proof reading): Niels Jungbluth (ESU)
extrapolations none
sampling procedure Own simulation.
production volume 10'433 systems with flat plate collectors were sold in 2008. 27.4% of the area is installed on multiple dwellings for hot water.
uncertainty adjustments none
validation details Proof reading validation: 17.12.2010; Other validation: \Server\E\ESU-Docs\Projekte laufend\352 Sonnenkollektoranlagen\Berechnung[neueingabe-Kollektoren-2.2+V1.0.xlsx]X-Process;
time period comment Time of simulation.

Data gaps, proxies and assumptions

None recorded.

Life cycle impact assessment (EF v3.1)

Per 1 p. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.

Impact category Indicator Unit Result 2.5 % 97.5 % GSD²
Acidification Accumulated Exceedance (AE) mol H+ eq 95.5 46.87 385.1 2.9
Climate change-Biogenic Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 22.2 12 97.31 2.96
Climate change-Fossil Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 9072 5378 3.087e+04 2.43
Climate change-Land use and land use change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 6.126 2.906 26.19 3.05
Climate change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 9100 5392 3.102e+04 2.43
EF-particulate Matter Impact on human health disease incidence 5.458e-04 3.379e-04 0.003589 3.42
Ecotoxicity, freshwater_inorganics Comparative Toxic Unit for ecosystems (CTUe) CTUe 1.165e+05 6.236e+04 4.990e+05 2.93
Ecotoxicity, freshwater_organics Comparative Toxic Unit for ecosystems (CTUe) CTUe 1741 1080 7233 2.65
Ecotoxicity, freshwater Comparative Toxic Unit for ecosystems (CTUe) CTUe 1.182e+05 6.386e+04 5.071e+05 2.91
Eutrophication marine Fraction of nutrients reaching marine end compartment (N) kg N eq 13.16 7.451 49.77 2.56
Eutrophication, freshwater Fraction of nutrients reaching freshwater end compartment (P) kg P eq 21.35 9.487 198.6 4.83
Eutrophication, terrestrial Accumulated Exceedance (AE) mol N eq 136.9 75.72 523.3 2.58
Human toxicity, cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 1.028e-05 6.312e-06 5.926e-05 3.12
Human toxicity, cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 2.916e-06 1.851e-06 1.199e-05 2.55
Human toxicity, cancer Comparative Toxic Unit for human (CTUh) CTUh 1.319e-05 8.231e-06 6.893e-05 2.9
Human toxicity, non-cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 7.926e-04 4.479e-04 0.004645 3.27
Human toxicity, non-cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 6.322e-05 2.756e-05 2.640e-04 3.2
Human toxicity, non-cancer Comparative Toxic Unit for human (CTUh) CTUh 8.558e-04 4.831e-04 0.004866 3.22
Ionising radiation, human health Human exposure efficiency relative to U235 kBq U235 eq 2864 879.6 2.604e+04 5.73
Land use Soil quality index pt (soil quality index) 9.744e+04 5.913e+04 3.432e+05 2.44
Ozone depletion Ozone Depletion Potential (ODP) kg CFC-11 eq 6.405e-04 3.591e-04 0.002162 2.58
Photochemical ozone formation - human health Tropospheric ozone concentration increase kg NMVOC eq 46.21 27.44 167.9 2.51
Resource use, fossils Abiotic resource depletion fossil fuels (ADP-fossil) MJ 1.281e+05 7.57e+04 4.681e+05 2.53
Resource use, minerals and metals Abiotic resource depletion (ADP ultimate reserve) kg Sb eq 0.5413 0.2397 2.05 2.91
Water use User deprivation potential (deprivation-weighted water consumption) m3 world eq deprived 782.9 -4.185e+06 2.429e+06 —

Climate change 9100 kg CO2 eq per p. Main contributors: Flat plate collector, copper absorber, at plant 53 %; Transport, freight, lorry, 3.5t gross weight, fleet average 21 %; Heat storage 2000l, at plant 13 %; Expansion vessel 80l, at plant 2 %; Aluminium, production mix, wrought alloy, at plant 2 %; Copper, at regional storage 2 %.

Interpretation

Significant issues

Direct exchanges dominating climate change: Flat plate collector, copper absorber, at plant 53 %; Transport, freight, lorry, 3.5t gross weight, fleet average 21 %; Heat storage 2000l, at plant 13 %; Expansion vessel 80l, at plant 2 %; Aluminium, production mix, wrought alloy, at plant 2 %; Copper, at regional storage 2 %. Most sensitive exchanges (Section 6.3): Flat plate collector, copper absorber, at plant [CH] (-41.3 / +192.4 %); Transport, freight, lorry, 3.5t gross weight, fleet average [CH] (-15.4 / +56.8 %); Heat storage 2000l, at plant [CH] (-10.6 / +49.4 %).

Independent recalculation

Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026):

Category Graph Published Graph / published
Acidification 95.5 101.5 0.941
Climate change-Biogenic 22.2 22.2 1.000
Climate change-Fossil 9072 9072 1.000
Climate change-Land use and land use change 6.126 6.126 1.000
Climate change 9100 9100 1.000
EF-particulate Matter 5.458e-04 5.458e-04 1.000
Ecotoxicity, freshwater_inorganics 1.165e+05 1.177e+05 0.990
Ecotoxicity, freshwater_organics 1741 1736 1.003
Ecotoxicity, freshwater 1.182e+05 1.194e+05 0.990
Eutrophication marine 13.16 13.16 1.000
Eutrophication, freshwater 21.35 21.35 1.000
Eutrophication, terrestrial 136.9 145.3 0.942
Human toxicity, cancer_inorganics 1.028e-05 1.024e-05 1.004
Human toxicity, cancer_organics 2.916e-06 2.916e-06 1.000
Human toxicity, cancer 1.319e-05 1.315e-05 1.003
Human toxicity, non-cancer_inorganics 7.926e-04 7.907e-04 1.002
Human toxicity, non-cancer_organics 6.322e-05 6.322e-05 1.000
Human toxicity, non-cancer 8.558e-04 8.540e-04 1.002
Ionising radiation, human health 2864 2864 1.000
Land use 9.744e+04 7.242e+04 1.345
Ozone depletion 6.405e-04 6.405e-04 1.000
Photochemical ozone formation - human health 46.21 46.21 1.000
Resource use, fossils 1.281e+05 1.282e+05 1.000
Resource use, minerals and metals 0.5413 0.5334 1.015
Water use 782.9 885.5 0.884
Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like.
Also published by BAFU for this dataset: IPCC 2021 GWP100 9099 kg CO2 eq; Ecological Scarcity
2021 total 2.845e+07 UBP.

Sensitivity check

One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.

Exchange Base Low / high Range Δ GWP100 (%) Δ other categories (max %)
Flat plate collector, copper absorber, at plant [CH] 81 m2 ×0.215 / ×4.66 lognormal, GSD² 4.81 -41.3 / +192.4 269.9 (Climate change-Land use and land use change)
Transport, freight, lorry, 3.5t gross weight, fleet average [CH] 1782 tkm ×0.271 / ×3.69 lognormal, GSD² 3.79 -15.4 / +56.8 124.5 (Ozone depletion)
Heat storage 2000l, at plant [CH] 1.359 p ×0.215 / ×4.66 lognormal, GSD² 4.81 -10.6 / +49.4 87.1 (Human toxicity, cancer_organics)
Expansion vessel 80l, at plant [CH] 5 p ×0.215 / ×4.66 lognormal, GSD² 4.81 -1.9 / +9.0 11.2 (Ionising radiation, human health)
Aluminium, production mix, wrought alloy, at plant [RER] 41.76 kg ×0.333 / ×3.01 lognormal, GSD² 3.07 -1.5 / +4.6 9.4 (Climate change-Land use and land use change)
Copper, at regional storage [RER] 127.1 kg ×0.333 / ×3.01 lognormal, GSD² 3.07 -1.5 / +4.5 63.6 (Human toxicity, non-cancer_organics)
Pump 40W, at plant [CH] 13.61 p ×0.215 / ×4.66 lognormal, GSD² 4.81 -0.8 / +3.9 6.6 (Human toxicity, non-cancer_inorganics)
Propylene glycol, liquid, at plant [RER] 47.69 kg ×0.333 / ×3.01 lognormal, GSD² 3.07 -1.0 / +3.1 51.9 (Ecotoxicity, freshwater_inorganics)
Treatment, heat carrier liquid, 40% C3H8O2, to wastewater treatment, class 2 [CH] 0.1289 m3 ×0.333 / ×3.01 lognormal, GSD² 3.07 -0.8 / +2.5 2.5 (Climate change-Fossil)
Rock wool, packed, at plant [CH] 77.08 kg ×0.333 / ×3.01 lognormal, GSD² 3.07 -0.6 / +1.9 5.2 (Ecotoxicity, freshwater_organics)
Drawing of pipes, steel [RER] 127.1 kg ×0.328 / ×3.05 lognormal, GSD² 3.12 -0.4 / +1.2 7.7 (Climate change-Land use and land use change)
Sheet rolling, aluminium [RER] 41.76 kg ×0.333 / ×3.01 lognormal, GSD² 3.07 -0.1 / +0.4 1.0 (Climate change-Biogenic)
Powder coating, aluminium sheet [RER] 2.088 m2 ×0.333 / ×3.01 lognormal, GSD² 3.07 -0.1 / +0.2 0.2 (Climate change-Biogenic)
Transport, freight, rail [RER] 224.9 tkm ×0.273 / ×3.66 lognormal, GSD² 3.76 -0.0 / +0.1 0.5 (Climate change-Biogenic)
Transport, freight, lorry, 16t-32t gross weight, fleet average [CH] 18.74 tkm ×0.273 / ×3.66 lognormal, GSD² 3.76 -0.0 / +0.1 0.1 (Photochemical ozone formation - human health)

Uncertainty analysis

Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.

Comparison with other data

No other location of this dataset in the graph.

Conclusions and limitations

GWP100 9100 kg CO2 eq per p (95 % interval 5392–3.102e+04). Dominant contributors: Flat plate collector, copper absorber, at plant 53 %; Transport, freight, lorry, 3.5t gross weight, fleet average 21 %; Heat storage 2000l, at plant 13 %; Expansion vessel 80l, at plant 2 %; Aluminium, production mix, wrought alloy, at plant 2 %; Copper, at regional storage 2 %. Most sensitive: Flat plate collector, copper absorber, at plant [CH] (-41.3 / +192.4 %); Transport, freight, lorry, 3.5t gross weight, fleet average [CH] (-15.4 / +56.8 %); Heat storage 2000l, at plant [CH] (-10.6 / +49.4 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.

Final control

Item Status Detail
reference flow PASS production amount 1.0 p
closure: sum of direct contributions = dataset score (all 25 categories) PASS largest relative gap 4.0e-16
independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) PASS graph / published = 1; categories within ±5 %: 21/25
every technosphere input of the EcoSpold delivery is in the graph PASS all present (bafu_links_check.py)
uncertainty declared on the direct exchanges PASS 16/16 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values
Monte Carlo 95 % interval contains the deterministic score PASS 9100 in [5392, 3.102e+04]
time period declared PASS 2000-01/2010-12
geography is a known location code PASS CH
sources cited PASS 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them

References

  1. Stucki M., Jungbluth N. (2010) Update of the Life Cycle Inventories of Solar Collectors. Volume: 352. ESU-services Ltd.. Uster, CH. Type: Separate publication First author: Stucki M. Other authors: Jungbluth N. Year: 2010 Place of publication: Uster, CH Publisher: ESU-services Ltd. Volume No: 352 — published source; as declared by BAFU (not found in OpenAlex/Crossref)
  2. Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — database; dataset citation
  3. International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva.
  4. Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. (tdc-doc method reference; title, version and year to verify against the user's copy)
  5. European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra.
  6. Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236

Annex — licence and terms of use

BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.


To suggest a correction or a dataset that does not exist yet, use Propose a dataset.