Table of Contents

Electric storage heater, 5kW — CH

Dataset documentation and final control (tdc-doc, imported mode)
Open this dataset in OpenData

Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Electric storage heater, 5kW [CH], per 1 p. EF v3.1 climate change 378.8 kg CO2 eq (Monte Carlo 95 % interval 358.2–535.1). Main contributors: Electronic component, passive, unspecified, at plant 24 %; Refractory, high aluminium oxide, packed, at plant 22 %; Steel, low-alloyed, at plant 16 %; Steel, electric, chromium steel 18/8, at plant 12 %; Chromium steel product manufacturing, average metal working 7 %; Electronic component, passive, unspecified, at plant 5 %. Status: final control passed.
Item Value
Dataset name Electric storage heater, 5kW
Dataset UUID / graph id f0049a79-7a30-32fa-afab-864243056ec1 / activity:electric_storage_heater_5kw__ch
Reference product, unit Electric storage heater, 5kW, 1 p
Location CH — Data apply to the supply in Switzerland. Production occurs at AEG Haustechnik / STIEBEL ELTRON GmbH & Co. KG (DE).
Time period 2009-01/2020-12
Category heat / heat pumps\heating systems
Source database BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1
Publisher Swiss Federal Office for the Environment (FOEN/BAFU)
Background database BAFU 2026 v1 (graph bafuquery-db)
LCIA method EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix)
Status final control passed
Documented by tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17

Introduction

Inventory for the production of an electric storage heater, 5kW, usage at home, with a life time of 20 years and 2'100 hours of heating within one year. Efficiency of 100% is assumed.; Synonyms: Elektrospeicherheizung; UUID: f0049a79-7a30-32fa-afab-864243056ec1

This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.

Goal and scope

Function, functional unit and reference flow

Reference flow: 1 p of Electric storage heater, 5kW (CH). All results are given per unit of the reference flow.

System boundary

Infrastructure of the electric storage heater, including all material input. Basic transportations of materials for the production included. No transportation to user, no end of life waste treatment included.

Technology

Industry data.

Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).

LCIA method

EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.

Life cycle inventory

Inventory table

Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).

Exchange Type Location / compartment Amount Unit Uncertainty Pedigree GWP share (%) Notes
Electronic component, passive, unspecified, at plant technosphere GLO 2 kg lognormal, GSD² 1.35 — 23.6 █████
Refractory, high aluminium oxide, packed, at plant technosphere DE 95.04 kg lognormal, GSD² 1.3 — 22.0 ████
Steel, low-alloyed, at plant technosphere RER 28.27 kg lognormal, GSD² 1.3 — 16.0 ███
Steel, electric, chromium steel 18/8, at plant technosphere RER 13.4 kg lognormal, GSD² 1.3 — 12.3 ██
Chromium steel product manufacturing, average metal working technosphere RER 13.4 kg lognormal, GSD² 1.3 — 7.3 █
Electronic component, passive, unspecified, at plant technosphere GLO 0.4 kg lognormal, GSD² 1.35 — 4.7 █
Sheet rolling, steel technosphere RER 28.27 kg lognormal, GSD² 1.3 — 2.8 █
Rock wool, packed, at plant technosphere CH 8.35 kg lognormal, GSD² 1.32 — 2.5 ·
Enamelling technosphere RER 1.7669 m2 lognormal, GSD² 1.31 — 2.3 ·
Expanded perlite, at plant technosphere CH 4.17 kg lognormal, GSD² 1.62 — 1.1 ·
Natural gas, burned in industrial furnace 1MW technosphere CH 45.002 MJ lognormal, GSD² 1.84 — 0.9 ·
Polyester resin, unsaturated, at plant technosphere RER 0.5 kg lognormal, GSD² 1.35 — 0.9 ·
Polyester resin, unsaturated, at plant technosphere RER 0.5 kg lognormal, GSD² 1.62 — 0.9 ·
Steel, low-alloyed, at plant technosphere RER 0.84 kg lognormal, GSD² 1.62 — 0.5 ·
Transport, freight, rail technosphere RER 96 tkm lognormal, GSD² 3.04 — 0.4 ·
Transport, freight, lorry, 16t-32t gross weight, fleet average technosphere CH 8 tkm lognormal, GSD² 3.04 — 0.4 ·
Steel product manufacturing, average metal working technosphere RER 0.84 kg lognormal, GSD² 1.62 — 0.3 ·
Steel, low-alloyed, at plant technosphere RER 0.5 kg lognormal, GSD² 1.31 — 0.3 ·
Light clay brick, at plant technosphere DE 4.17 kg lognormal, GSD² 1.62 — 0.2 ·
Rock wool, packed, at plant technosphere CH 0.565 kg lognormal, GSD² 1.3 — 0.2 ·
Sheet rolling, steel technosphere RER 1 kg lognormal, GSD² 1.31 — 0.1 ·
Zinc, from combined metal production, at refinery technosphere SE 0.5 kg lognormal, GSD² 1.31 — 0.1 ·
Sheet rolling, steel technosphere RER 0.84 kg lognormal, GSD² 1.62 — 0.1 ·
Expanded perlite, at plant technosphere CH 0.282 kg lognormal, GSD² 1.3 — 0.1 ·
Sheet rolling, aluminium technosphere RER 0.5 kg lognormal, GSD² 1.31 — 0.1 ·
Electricity, medium voltage, production CH, at grid technosphere CH 5.52 kWh lognormal, GSD² 1.84 — 0.0 ·
Light clay brick, at plant technosphere DE 0.282 kg lognormal, GSD² 1.3 — 0.0 ·

Data quality

0 of 27 direct exchanges carry a declared pedigree, 27 carry a distribution.

Field As declared by the publisher
Data generator / entry / validation data generator: Livia Waldburger (CARBOTECH); data entry: Thomas Kaegi (CARBOTECH); validation (proof reading): Andy Spoerri (EBP)
extrapolations Data for Germany used with assumptions for Swiss energy supply.
sampling procedure Data provided by manufacturer
production volume na
uncertainty adjustments none
validation details Proof reading validation: 17.08.2020; Other validation: Z:\Schreibtisch\WinShare\BAFU Heizsysteme[EcoSpold_electric storage heater_v0.1_lwa.xlsx]X-Process;
time period comment Materials and energy use based on AEG Nachtspeicherofen/ electric storage heater published in 2016.

Data gaps, proxies and assumptions

None recorded.

Life cycle impact assessment (EF v3.1)

Per 1 p. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.

Impact category Indicator Unit Result 2.5 % 97.5 % GSD²
Acidification Accumulated Exceedance (AE) mol H+ eq 1.674 1.524 2.603 1.32
Climate change-Biogenic Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 1.382 0.9314 3.522 1.95
Climate change-Fossil Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 377.3 356.3 533 1.22
Climate change-Land use and land use change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.1383 0.1191 0.2503 1.46
Climate change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 378.8 358.2 535.1 1.22
EF-particulate Matter Impact on human health disease incidence 2.022e-05 1.913e-05 3.195e-05 1.3
Ecotoxicity, freshwater_inorganics Comparative Toxic Unit for ecosystems (CTUe) CTUe 1699 1586 3653 1.54
Ecotoxicity, freshwater_organics Comparative Toxic Unit for ecosystems (CTUe) CTUe 58.39 53.09 156.7 2
Ecotoxicity, freshwater Comparative Toxic Unit for ecosystems (CTUe) CTUe 1757 1664 3812 1.54
Eutrophication marine Fraction of nutrients reaching marine end compartment (N) kg N eq 0.4201 0.3812 0.6944 1.36
Eutrophication, freshwater Fraction of nutrients reaching freshwater end compartment (P) kg P eq 0.5662 0.3487 3.474 3.44
Eutrophication, terrestrial Accumulated Exceedance (AE) mol N eq 4.125 3.768 6.626 1.34
Human toxicity, cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 2.690e-07 2.596e-07 6.420e-07 1.63
Human toxicity, cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 1.232e-07 1.149e-07 2.031e-07 1.33
Human toxicity, cancer Comparative Toxic Unit for human (CTUh) CTUh 3.922e-07 3.942e-07 7.982e-07 1.48
Human toxicity, non-cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 1.541e-05 1.408e-05 4.848e-05 1.96
Human toxicity, non-cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 5.194e-07 4.356e-07 1.014e-06 1.51
Human toxicity, non-cancer Comparative Toxic Unit for human (CTUh) CTUh 1.593e-05 1.468e-05 4.919e-05 1.94
Ionising radiation, human health Human exposure efficiency relative to U235 kBq U235 eq 84.82 30.37 582.6 4.49
Land use Soil quality index pt (soil quality index) 2589 2245 5137 1.5
Ozone depletion Ozone Depletion Potential (ODP) kg CFC-11 eq 9.576e-06 8.307e-06 1.621e-05 1.4
Photochemical ozone formation - human health Tropospheric ozone concentration increase kg NMVOC eq 1.831 1.651 2.995 1.34
Resource use, fossils Abiotic resource depletion fossil fuels (ADP-fossil) MJ 5063 4681 7919 1.31
Resource use, minerals and metals Abiotic resource depletion (ADP ultimate reserve) kg Sb eq 0.0993 0.06598 0.21 1.79
Water use User deprivation potential (deprivation-weighted water consumption) m3 world eq deprived 30.77 -1.902e+05 9.895e+04 —

Climate change 378.8 kg CO2 eq per p. Main contributors: Electronic component, passive, unspecified, at plant 24 %; Refractory, high aluminium oxide, packed, at plant 22 %; Steel, low-alloyed, at plant 16 %; Steel, electric, chromium steel 18/8, at plant 12 %; Chromium steel product manufacturing, average metal working 7 %; Electronic component, passive, unspecified, at plant 5 %.

Interpretation

Significant issues

Direct exchanges dominating climate change: Electronic component, passive, unspecified, at plant 24 %; Refractory, high aluminium oxide, packed, at plant 22 %; Steel, low-alloyed, at plant 16 %; Steel, electric, chromium steel 18/8, at plant 12 %; Chromium steel product manufacturing, average metal working 7 %; Electronic component, passive, unspecified, at plant 5 %. Most sensitive exchanges (Section 6.3): Electronic component, passive, unspecified, at plant [GLO] (-6.0 / +8.0 %); Refractory, high aluminium oxide, packed, at plant [DE] (-5.0 / +6.5 %); Steel, low-alloyed, at plant [RER] (-3.6 / +4.7 %).

Independent recalculation

Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026):

Category Graph Published Graph / published
Acidification 1.674 4.155 0.403
Climate change-Biogenic 1.382 1.382 1.000
Climate change-Fossil 377.3 377.3 1.000
Climate change-Land use and land use change 0.1383 0.1383 1.000
Climate change 378.8 378.8 1.000
EF-particulate Matter 2.022e-05 2.022e-05 1.000
Ecotoxicity, freshwater_inorganics 1699 1741 0.976
Ecotoxicity, freshwater_organics 58.39 56.45 1.035
Ecotoxicity, freshwater 1757 1771 0.992
Eutrophication marine 0.4201 0.4201 1.000
Eutrophication, freshwater 0.5662 0.5662 1.000
Eutrophication, terrestrial 4.125 4.386 0.940
Human toxicity, cancer_inorganics 2.690e-07 2.672e-07 1.007
Human toxicity, cancer_organics 1.232e-07 1.232e-07 1.000
Human toxicity, cancer 3.922e-07 3.904e-07 1.005
Human toxicity, non-cancer_inorganics 1.541e-05 1.530e-05 1.007
Human toxicity, non-cancer_organics 5.194e-07 5.193e-07 1.000
Human toxicity, non-cancer 1.593e-05 1.582e-05 1.007
Ionising radiation, human health 84.82 84.82 1.000
Land use 2589 2153 1.203
Ozone depletion 9.576e-06 9.576e-06 1.000
Photochemical ozone formation - human health 1.831 1.831 1.000
Resource use, fossils 5063 5065 1.000
Resource use, minerals and metals 0.0993 0.09902 1.003
Water use 30.77 35.12 0.876
Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like.
Also published by BAFU for this dataset: IPCC 2021 GWP100 378.7 kg CO2 eq; Ecological Scarcity
2021 total 1.127e+06 UBP.

Sensitivity check

One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.

Exchange Base Low / high Range Δ GWP100 (%) Δ other categories (max %)
Electronic component, passive, unspecified, at plant [GLO] 2 kg ×0.748 / ×1.34 lognormal, GSD² 1.35 -6.0 / +8.0 27.2 (Resource use, minerals and metals)
Refractory, high aluminium oxide, packed, at plant [DE] 95.04 kg ×0.772 / ×1.3 lognormal, GSD² 1.3 -5.0 / +6.5 8.3 (Eutrophication marine)
Steel, low-alloyed, at plant [RER] 28.27 kg ×0.772 / ×1.3 lognormal, GSD² 1.3 -3.6 / +4.7 6.1 (Human toxicity, cancer_organics)
Steel, electric, chromium steel 18/8, at plant [RER] 13.4 kg ×0.772 / ×1.3 lognormal, GSD² 1.3 -2.8 / +3.6 11.7 (Human toxicity, cancer_inorganics)
Chromium steel product manufacturing, average metal working [RER] 13.4 kg ×0.772 / ×1.3 lognormal, GSD² 1.3 -1.7 / +2.2 3.8 (Climate change-Biogenic)
Electronic component, passive, unspecified, at plant [GLO] 0.4 kg ×0.748 / ×1.34 lognormal, GSD² 1.35 -1.2 / +1.6 5.4 (Resource use, minerals and metals)
Sheet rolling, steel [RER] 28.27 kg ×0.772 / ×1.3 lognormal, GSD² 1.3 -0.6 / +0.8 2.2 (Water use)
Rock wool, packed, at plant [CH] 8.35 kg ×0.759 / ×1.32 lognormal, GSD² 1.32 -0.6 / +0.8 2.7 (Ecotoxicity, freshwater_organics)
Enamelling [RER] 1.767 m2 ×0.767 / ×1.3 lognormal, GSD² 1.31 -0.5 / +0.7 3.4 (Ionising radiation, human health)
Natural gas, burned in industrial furnace 1MW [CH] 45 MJ ×0.549 / ×1.82 lognormal, GSD² 1.84 -0.4 / +0.7 0.9 (Resource use, fossils)
Expanded perlite, at plant [CH] 4.17 kg ×0.622 / ×1.61 lognormal, GSD² 1.62 -0.4 / +0.7 2.8 (Ozone depletion)
Transport, freight, rail [RER] 96 tkm ×0.337 / ×2.97 lognormal, GSD² 3.04 -0.3 / +0.8 4.0 (Land use)
Transport, freight, lorry, 16t-32t gross weight, fleet average [CH] 8 tkm ×0.337 / ×2.97 lognormal, GSD² 3.04 -0.2 / +0.7 1.0 (Ozone depletion)
Polyester resin, unsaturated, at plant [RER] 0.5 kg ×0.622 / ×1.61 lognormal, GSD² 1.62 -0.3 / +0.5 3.8 (Ecotoxicity, freshwater_organics)
Polyester resin, unsaturated, at plant [RER] 0.5 kg ×0.748 / ×1.34 lognormal, GSD² 1.35 -0.2 / +0.3 2.1 (Ecotoxicity, freshwater_organics)

Uncertainty analysis

Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.

Comparison with other data

No other location of this dataset in the graph.

Conclusions and limitations

GWP100 378.8 kg CO2 eq per p (95 % interval 358.2–535.1). Dominant contributors: Electronic component, passive, unspecified, at plant 24 %; Refractory, high aluminium oxide, packed, at plant 22 %; Steel, low-alloyed, at plant 16 %; Steel, electric, chromium steel 18/8, at plant 12 %; Chromium steel product manufacturing, average metal working 7 %; Electronic component, passive, unspecified, at plant 5 %. Most sensitive: Electronic component, passive, unspecified, at plant [GLO] (-6.0 / +8.0 %); Refractory, high aluminium oxide, packed, at plant [DE] (-5.0 / +6.5 %); Steel, low-alloyed, at plant [RER] (-3.6 / +4.7 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.

Final control

Item Status Detail
reference flow PASS production amount 1.0 p
closure: sum of direct contributions = dataset score (all 25 categories) PASS largest relative gap 4.0e-16
independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) PASS graph / published = 1; categories within ±5 %: 21/25
every technosphere input of the EcoSpold delivery is in the graph PASS all present (bafu_links_check.py)
uncertainty declared on the direct exchanges PASS 27/27 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values
Monte Carlo 95 % interval contains the deterministic score PASS 378.8 in [358.2, 535.1]
time period declared PASS 2009-01/2020-12
geography is a known location code PASS CH
sources cited PASS 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them

References

  1. Kägi Thomas, Livia Waldburger, Cyril Kern, Gavin Roberts, Mischa Zschokke, Flora Conte, Lea Weber (2020) LCI of heating systems. Carbotech im Auftrag des BAFU. Carbotech AG. Zürich. CH. Type: Separate publication Source: Report First author: Kägi Thomas Other authors: Livia Waldburger, Cyril Kern, Gavin Roberts, Mischa Zschokke, Flora Conte, Lea Weber Year: 2020 Title of anthology: Carbotech im Au… — published source; as declared by BAFU (not found in OpenAlex/Crossref)
  2. Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — database; dataset citation
  3. International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva.
  4. Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. (tdc-doc method reference; title, version and year to verify against the user's copy)
  5. European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra.
  6. Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236

Annex — licence and terms of use

BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.


To suggest a correction or a dataset that does not exist yet, use Propose a dataset.