Table of Contents

Electricity mix, winter 2018 — CH

Dataset documentation and final control (tdc-doc, imported mode)
Open this dataset in OpenData

Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Electricity mix, winter 2018 [CH], per 1 kWh. EF v3.1 climate change 0.1275 kg CO2 eq (Monte Carlo 95 % interval 0.1184–0.1616). Main contributors: Electricity, lignite, at power plant 26 %; Electricity, hard coal, at power plant 17 %; Electricity, natural gas, at power plant 8 %; Electricity, natural gas, at power plant 8 %; Electricity, industrial gas, at power plant 5 %; Electricity, natural gas, at power plant 4 %. Status: final control passed.
Item Value
Dataset name Electricity mix, winter 2018
Dataset UUID / graph id fdc628a0-bb09-3da8-b2e0-a46e584af7ab / activity:electricity_mix_winter_2018__ch
Reference product, unit Electricity mix, winter 2018, 1 kWh
Location CH — Switzerland
Time period 2018-01/2018-12
Category electricity / supply mix
Source database BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1
Publisher Swiss Federal Office for the Environment (FOEN/BAFU)
Background database BAFU 2026 v1 (graph bafuquery-db)
LCIA method EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix)
Status final control passed
Documented by tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17

Introduction

The operational electricity consumption (heating, hot water, ventilation, lighting, and auxiliaries) is modelled by a specific electricity mix used for the electricity consumption of Switzerland in winter 2018.; UUID: fdc628a0-bb09-3da8-b2e0-a46e584af7ab

This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.

Goal and scope

Function, functional unit and reference flow

Reference flow: 1 kWh of Electricity mix, winter 2018 (CH). All results are given per unit of the reference flow.

System boundary

This dataset includes the shares of different technologies of the electricity mix used for the electricity consumption in Switzerland.

Technology

Average technology

Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).

LCIA method

EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.

Life cycle inventory

Inventory table

Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).

Exchange Type Location / compartment Amount Unit Uncertainty Pedigree GWP share (%) Notes
Electricity, lignite, at power plant technosphere DE 0.031818 kWh lognormal, GSD² 1.31 — 26.4 █████
Electricity, hard coal, at power plant technosphere DE 0.021784 kWh lognormal, GSD² 1.31 — 17.5 ███
Electricity, natural gas, at power plant technosphere FR 0.021721 kWh lognormal, GSD² 1.31 — 8.1 ██
Electricity, natural gas, at power plant technosphere AT 0.020998 kWh lognormal, GSD² 1.31 — 8.1 ██
Electricity, industrial gas, at power plant technosphere IT 0.0048446 kWh lognormal, GSD² 1.31 — 5.5 █
Electricity, natural gas, at power plant technosphere DE 0.010611 kWh lognormal, GSD² 1.31 — 4.4 █
Electricity, hard coal, at power plant technosphere FR 0.0036595 kWh lognormal, GSD² 1.31 — 3.5 █
Electricity, hard coal, at power plant technosphere AT 0.0041606 kWh lognormal, GSD² 1.31 — 2.8 █
Electricity, hydropower, at pumped storage plant, ENTSO, winter 2018 technosphere CH 0.017657 kWh lognormal, GSD² 1.31 — 2.5 ·
Electricity, natural gas, at power plant technosphere IT 0.005957 kWh lognormal, GSD² 1.31 — 2.3 ·
Electricity, at cogen 300kWth, natural gas, allocation exergy technosphere CH 0.0044804 kWh lognormal, GSD² 1.31 — 2.2 ·
Electricity, hard coal, at power plant technosphere IT 0.0021487 kWh lognormal, GSD² 1.31 — 1.9 ·
Electricity, hydropower, at pumped storage plant, ENTSO, winter 2018 technosphere AT 0.0068805 kWh lognormal, GSD² 1.31 — 1.3 ·
Electricity, hydropower, at pumped storage plant, ENTSO, winter 2018 technosphere DE 0.0023759 kWh lognormal, GSD² 1.31 — 1.2 ·
Electricity, at cogen 300kWth, biomethane, allocation exergy technosphere CH 0.0046059 kWh lognormal, GSD² 1.31 — 1.1 ·
Electricity, nuclear, at power plant pressure water reactor technosphere FR 0.21801 kWh lognormal, GSD² 1.31 — 1.1 ·
Electricity, nuclear, at power plant boiling water reactor technosphere CH 0.085603 kWh lognormal, GSD² 1.31 — 1.0 ·
Electricity, nuclear, at power plant pressure water reactor technosphere CH 0.095199 kWh lognormal, GSD² 1.31 — 1.0 ·
Electricity, industrial gas, at power plant technosphere DE 9.2107e-04 kWh lognormal, GSD² 1.31 — 0.9 ·
Electricity, industrial gas, at power plant technosphere DE 8.4796e-04 kWh lognormal, GSD² 1.31 — 0.8 ·
Electricity, at cogen with biogas engine, allocation exergy technosphere CH 0.0054975 kWh lognormal, GSD² 1.31 — 0.7 ·
Electricity, oil, at power plant technosphere DE 6.8043e-04 kWh lognormal, GSD² 1.31 — 0.7 ·
Electricity, oil, at power plant technosphere FR 0.0010017 kWh lognormal, GSD² 1.31 — 0.7 ·
Electricity, hydropower, net, at reservoir power plant technosphere CH 0.12806 kWh lognormal, GSD² 1.31 — 0.5 ·
Electricity, at cogen 1MWth, wood chips, allocation exergy technosphere CH 0.0064826 kWh lognormal, GSD² 1.31 — 0.3 ·
Electricity, at 100MW wind farm, onshore, 2.3MW turbines technosphere RER 0.023355 kWh lognormal, GSD² 1.31 — 0.3 ·
Electricity, at cogen with biogas engine, agricultural covered, alloc. exergy technosphere CH 0.0020105 kWh lognormal, GSD² 1.31 — 0.2 ·
Electricity, industrial gas, at power plant technosphere AT 3.2632e-04 kWh lognormal, GSD² 1.31 — 0.2 ·
Electricity, at cogen 1MWth, wood chips, allocation exergy technosphere CH 0.0045229 kWh lognormal, GSD² 1.31 — 0.2 ·
Electricity, hydropower, at run-of-river power plant technosphere CH 0.073153 kWh lognormal, GSD² 1.31 — 0.2 ·
Electricity, at wind farm technosphere RER 0.018552 kWh lognormal, GSD² 1.31 — 0.2 ·
Electricity, hydropower, at pumped storage plant, ENTSO, winter 2018 technosphere FR 0.0027534 kWh lognormal, GSD² 1.31 — 0.2 ·
Electricity, at cogen 1MWth, wood chips, allocation exergy technosphere CH 0.0034366 kWh lognormal, GSD² 1.31 — 0.2 ·
Electricity, industrial gas, at power plant technosphere IT 1.3580e-04 kWh lognormal, GSD² 1.31 — 0.2 ·
Electricity, production mix photovoltaic, at plant technosphere CH 0.0063177 kWh lognormal, GSD² 1.31 — 0.1 ·
Electricity, at cogen with biogas engine, allocation exergy technosphere CH 0.0010598 kWh lognormal, GSD² 1.31 — 0.1 ·
Electricity, at wind farm technosphere RER 0.012132 kWh lognormal, GSD² 1.31 — 0.1 ·
Electricity, production mix photovoltaic, at plant technosphere DE 0.0051747 kWh lognormal, GSD² 1.31 — 0.1 ·
Electricity, nuclear, at power plant pressure water reactor technosphere DE 0.014506 kWh lognormal, GSD² 1.31 — 0.1 ·
Electricity, hydropower, at pumped storage plant, ENTSO, winter 2018 technosphere IT 1.4705e-04 kWh lognormal, GSD² 1.31 — 0.1 ·
Electricity, hydropower, at run-of-river power plant technosphere RER 0.034331 kWh lognormal, GSD² 1.31 — 0.1 ·
Electricity, at cogen 300kWth, diesel, allocation exergy technosphere CH 1.4266e-04 kWh lognormal, GSD² 1.31 — 0.1 ·
Electricity, production mix photovoltaic, at plant technosphere FR 0.0031404 kWh lognormal, GSD² 1.31 — 0.1 ·
Electricity, at cogen with biogas engine, allocation exergy technosphere CH 5.5272e-04 kWh lognormal, GSD² 1.31 — 0.1 ·
Electricity, oil, at power plant technosphere IT 9.0506e-05 kWh lognormal, GSD² 1.31 — 0.1 ·
Electricity, hydropower, at small hydropower plant technosphere CH 0.017968 kWh lognormal, GSD² 1.31 — 0.1 ·
Electricity, hydropower, at run-of-river power plant technosphere RER 0.021042 kWh lognormal, GSD² 1.31 — 0.1 ·
Electricity, at 100MW wind farm, onshore, 2.3MW turbines technosphere RER 0.0050926 kWh lognormal, GSD² 1.31 — 0.1 ·
Electricity, at cogen 1MWth, wood chips, allocation exergy technosphere CH 0.0011597 kWh lognormal, GSD² 1.31 — 0.1 ·
Electricity, at cogen 300kWth, diesel, allocation exergy technosphere CH 7.5250e-05 kWh lognormal, GSD² 1.31 — 0.0 ·
Electricity, hydropower, at reservoir power plant, alpine region technosphere RER 0.0091844 kWh lognormal, GSD² 1.31 — 0.0 ·
Electricity, at cogen 300kWth, diesel, allocation exergy technosphere CH 5.9470e-05 kWh lognormal, GSD² 1.31 — 0.0 ·
Electricity, nuclear, at power plant boiling water reactor technosphere DE 0.0039288 kWh lognormal, GSD² 1.31 — 0.0 ·
Electricity, production mix photovoltaic, at plant technosphere AT 0.0012411 kWh lognormal, GSD² 1.31 — 0.0 ·
Electricity, at wind farm technosphere RER 0.0020121 kWh lognormal, GSD² 1.31 — 0.0 ·
Electricity, hydropower, at reservoir power plant, alpine region technosphere RER 0.0051501 kWh lognormal, GSD² 1.31 — 0.0 ·
Electricity, production mix photovoltaic, at plant technosphere IT 9.6991e-04 kWh lognormal, GSD² 1.31 — 0.0 ·
Electricity, at cogen with biogas engine, allocation exergy technosphere CH 1.0482e-04 kWh lognormal, GSD² 1.31 — 0.0 ·
Electricity, at wind farm technosphere CH 9.9313e-04 kWh lognormal, GSD² 1.31 — 0.0 ·
Electricity, hydropower, at run-of-river power plant technosphere RER 0.0031136 kWh lognormal, GSD² 1.31 — 0.0 ·
Electricity, at cogen 1MWth, wood chips, allocation exergy technosphere CH 1.7308e-04 kWh lognormal, GSD² 1.31 — 0.0 ·
Electricity, hydropower, at run-of-river power plant technosphere RER 0.0020034 kWh lognormal, GSD² 1.31 — 0.0 ·
Electricity, at wind farm technosphere RER 4.5372e-04 kWh lognormal, GSD² 1.31 — 0.0 ·
Electricity, at 100MW wind farm, onshore, 2.3MW turbines technosphere RER 3.5070e-04 kWh lognormal, GSD² 1.31 — 0.0 ·
Electricity, hydropower, at reservoir power plant, non alpine regions technosphere RER 1.7104e-04 kWh lognormal, GSD² 1.31 — 0.0 ·
Electricity, hydropower, at reservoir power plant, alpine region technosphere RER 4.5028e-04 kWh lognormal, GSD² 1.31 — 0.0 ·
Electricity, at cogen 300kWth, diesel, allocation exergy technosphere CH 2.0236e-06 kWh lognormal, GSD² 1.31 — 0.0 ·
Electricity, at wind farm technosphere RER 7.5022e-06 kWh lognormal, GSD² 1.31 — 0.0 ·
Electricity from waste, at municipal waste incineration plant technosphere CH 0.008415 kWh lognormal, GSD² 1.31 — -0.0 ·
Electricity from waste, at municipal waste incineration plant technosphere CH 0.0014833 kWh lognormal, GSD² 1.31 — -0.0 ·
Electricity from waste, at municipal waste incineration plant technosphere CH 0.0014726 kWh lognormal, GSD² 1.31 — -0.0 ·
Electricity from waste, at municipal waste incineration plant technosphere CH 0.0010506 kWh lognormal, GSD² 1.31 — -0.0 ·
Electricity from waste, at municipal waste incineration plant technosphere CH 2.5732e-05 kWh lognormal, GSD² 1.31 — -0.0 ·

Data quality

0 of 73 direct exchanges carry a declared pedigree, 73 carry a distribution.

Field As declared by the publisher
Data generator / entry / validation data generator: Philippe Stolz (TREEZE); data entry: Philippe Stolz (TREEZE); validation (proof reading): Rolf Frischknecht (TREEZE)
extrapolations Some generic datasets from ecoinvent have been used.
sampling procedure Statistics
production volume na
uncertainty adjustments
validation details Proof reading validation: 20.07.2020; Other validation: G:\Projekte laufend\651 Strommixe LCA Gebäude BFE\EcoSpold[651-Electricity-Mixes-Attributional-CH-v0.19.xlsx]X-Process;
time period comment Time of publications

Data gaps, proxies and assumptions

None recorded.

Life cycle impact assessment (EF v3.1)

Per 1 kWh. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.

Impact category Indicator Unit Result 2.5 % 97.5 % GSD²
Acidification Accumulated Exceedance (AE) mol H+ eq 1.973e-04 1.897e-04 2.563e-04 1.17
Climate change-Biogenic Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.001857 0.001392 0.002706 1.38
Climate change-Fossil Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.1254 0.1163 0.1592 1.18
Climate change-Land use and land use change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 2.537e-04 1.899e-04 3.785e-04 1.41
Climate change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.1275 0.1184 0.1616 1.18
EF-particulate Matter Impact on human health disease incidence 4.470e-09 3.512e-09 7.651e-09 1.49
Ecotoxicity, freshwater_inorganics Comparative Toxic Unit for ecosystems (CTUe) CTUe 0.3595 0.3047 0.7755 1.62
Ecotoxicity, freshwater_organics Comparative Toxic Unit for ecosystems (CTUe) CTUe 0.004216 0.003373 0.01371 2.06
Ecotoxicity, freshwater Comparative Toxic Unit for ecosystems (CTUe) CTUe 0.3637 0.3085 0.7837 1.62
Eutrophication marine Fraction of nutrients reaching marine end compartment (N) kg N eq 9.453e-05 8.923e-05 1.238e-04 1.19
Eutrophication, freshwater Fraction of nutrients reaching freshwater end compartment (P) kg P eq 1.130e-04 5.057e-05 4.030e-04 2.85
Eutrophication, terrestrial Accumulated Exceedance (AE) mol N eq 5.812e-04 5.589e-04 7.993e-04 1.2
Human toxicity, cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 9.846e-12 1.022e-11 3.089e-11 1.79
Human toxicity, cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 5.050e-11 3.913e-11 7.714e-11 1.43
Human toxicity, cancer Comparative Toxic Unit for human (CTUh) CTUh 6.034e-11 5.245e-11 9.728e-11 1.38
Human toxicity, non-cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 6.515e-10 6.297e-10 1.925e-09 1.79
Human toxicity, non-cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 3.052e-11 2.858e-11 5.543e-11 1.4
Human toxicity, non-cancer Comparative Toxic Unit for human (CTUh) CTUh 6.820e-10 6.635e-10 1.962e-09 1.76
Ionising radiation, human health Human exposure efficiency relative to U235 kBq U235 eq 0.717 0.2637 4.197 4.12
Land use Soil quality index pt (soil quality index) 1.469 0.9683 2.526 1.64
Ozone depletion Ozone Depletion Potential (ODP) kg CFC-11 eq 1.120e-08 9.497e-09 1.532e-08 1.28
Photochemical ozone formation - human health Tropospheric ozone concentration increase kg NMVOC eq 2.091e-04 1.983e-04 3.545e-04 1.36
Resource use, fossils Abiotic resource depletion fossil fuels (ADP-fossil) MJ 7.409 6.538 9.576 1.23
Resource use, minerals and metals Abiotic resource depletion (ADP ultimate reserve) kg Sb eq 1.036e-07 1.044e-07 1.849e-07 1.35
Water use User deprivation potential (deprivation-weighted water consumption) m3 world eq deprived 0.06449 -185.9 96.49 —

Climate change 0.1275 kg CO2 eq per kWh. Main contributors: Electricity, lignite, at power plant 26 %; Electricity, hard coal, at power plant 17 %; Electricity, natural gas, at power plant 8 %; Electricity, natural gas, at power plant 8 %; Electricity, industrial gas, at power plant 5 %; Electricity, natural gas, at power plant 4 %.

Interpretation

Significant issues

Direct exchanges dominating climate change: Electricity, lignite, at power plant 26 %; Electricity, hard coal, at power plant 17 %; Electricity, natural gas, at power plant 8 %; Electricity, natural gas, at power plant 8 %; Electricity, industrial gas, at power plant 5 %; Electricity, natural gas, at power plant 4 %. Most sensitive exchanges (Section 6.3): Electricity, lignite, at power plant [DE] (-6.1 / +7.9 %); Electricity, hard coal, at power plant [DE] (-4.0 / +5.2 %); Electricity, natural gas, at power plant [FR] (-1.9 / +2.4 %).

Independent recalculation

Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh:

Category Graph Published Graph / published
Acidification 1.973e-04 2.227e-04 0.886
Climate change-Biogenic 0.001857 0.001857 1.000
Climate change-Fossil 0.1254 0.1254 1.000
Climate change-Land use and land use change 2.537e-04 2.537e-04 1.000
Climate change 0.1275 0.1275 1.000
EF-particulate Matter 4.470e-09 4.470e-09 1.000
Ecotoxicity, freshwater_inorganics 0.3595 0.384 0.936
Ecotoxicity, freshwater_organics 0.004216 0.004124 1.022
Ecotoxicity, freshwater 0.3637 0.388 0.937
Eutrophication marine 9.453e-05 9.422e-05 1.003
Eutrophication, freshwater 1.130e-04 1.130e-04 1.000
Eutrophication, terrestrial 5.812e-04 6.816e-04 0.853
Human toxicity, cancer_inorganics 9.846e-12 8.215e-12 1.198
Human toxicity, cancer_organics 5.050e-11 5.050e-11 1.000
Human toxicity, cancer 6.034e-11 5.871e-11 1.028
Human toxicity, non-cancer_inorganics 6.515e-10 5.746e-10 1.134
Human toxicity, non-cancer_organics 3.052e-11 3.051e-11 1.000
Human toxicity, non-cancer 6.820e-10 6.051e-10 1.127
Ionising radiation, human health 0.717 0.717 1.000
Land use 1.469 1.187 1.238
Ozone depletion 1.120e-08 1.120e-08 1.000
Photochemical ozone formation - human health 2.091e-04 2.091e-04 1.000
Resource use, fossils 7.409 7.409 1.000
Resource use, minerals and metals 1.036e-07 9.907e-08 1.045
Water use 0.06449 0.07353 0.877
Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like.
Also published by BAFU for this dataset: IPCC 2021 GWP100 0.1275 kg CO2 eq; Ecological Scarcity
2021 total 464 UBP.

Sensitivity check

One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.

Exchange Base Low / high Range Δ GWP100 (%) Δ other categories (max %)
Electricity, lignite, at power plant [DE] 0.03182 kWh ×0.769 / ×1.3 lognormal, GSD² 1.31 -6.1 / +7.9 22.4 (Eutrophication, freshwater)
Electricity, hard coal, at power plant [DE] 0.02178 kWh ×0.769 / ×1.3 lognormal, GSD² 1.31 -4.0 / +5.2 6.1 (Acidification)
Electricity, natural gas, at power plant [FR] 0.02172 kWh ×0.769 / ×1.3 lognormal, GSD² 1.31 -1.9 / +2.4 5.7 (Ecotoxicity, freshwater_organics)
Electricity, natural gas, at power plant [AT] 0.021 kWh ×0.769 / ×1.3 lognormal, GSD² 1.31 -1.9 / +2.4 6.1 (Ecotoxicity, freshwater_organics)
Electricity, industrial gas, at power plant [IT] 0.004845 kWh ×0.769 / ×1.3 lognormal, GSD² 1.31 -1.3 / +1.6 3.0 (Human toxicity, cancer_organics)
Electricity, natural gas, at power plant [DE] 0.01061 kWh ×0.769 / ×1.3 lognormal, GSD² 1.31 -1.0 / +1.3 2.0 (Ecotoxicity, freshwater_organics)
Electricity, hard coal, at power plant [FR] 0.003659 kWh ×0.769 / ×1.3 lognormal, GSD² 1.31 -0.8 / +1.1 1.8 (Acidification)
Electricity, hard coal, at power plant [AT] 0.004161 kWh ×0.769 / ×1.3 lognormal, GSD² 1.31 -0.6 / +0.8 0.9 (Human toxicity, non-cancer_organics)
Electricity, hydropower, at pumped storage plant, ENTSO, winter 2018 [CH] 0.01766 kWh ×0.769 / ×1.3 lognormal, GSD² 1.31 -0.6 / +0.7 3.5 (Climate change-Land use and land use change)
Electricity, natural gas, at power plant [IT] 0.005957 kWh ×0.769 / ×1.3 lognormal, GSD² 1.31 -0.5 / +0.7 1.7 (Ecotoxicity, freshwater_organics)
Electricity, at cogen 300kWth, natural gas, allocation exergy [CH] 0.00448 kWh ×0.769 / ×1.3 lognormal, GSD² 1.31 -0.5 / +0.7 1.4 (Ecotoxicity, freshwater_organics)
Electricity, hard coal, at power plant [IT] 0.002149 kWh ×0.769 / ×1.3 lognormal, GSD² 1.31 -0.4 / +0.6 0.6 (Climate change-Fossil)
Electricity, hydropower, at pumped storage plant, ENTSO, winter 2018 [AT] 0.006881 kWh ×0.769 / ×1.3 lognormal, GSD² 1.31 -0.3 / +0.4 1.2 (Climate change-Land use and land use change)
Electricity, hydropower, at pumped storage plant, ENTSO, winter 2018 [DE] 0.002376 kWh ×0.769 / ×1.3 lognormal, GSD² 1.31 -0.3 / +0.4 0.6 (Eutrophication, freshwater)
Electricity, at cogen 300kWth, biomethane, allocation exergy [CH] 0.004606 kWh ×0.769 / ×1.3 lognormal, GSD² 1.31 -0.3 / +0.3 13.9 (Climate change-Biogenic)

Uncertainty analysis

Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.

Comparison with other data

No other location of this dataset in the graph.

Conclusions and limitations

GWP100 0.1275 kg CO2 eq per kWh (95 % interval 0.1184–0.1616). Dominant contributors: Electricity, lignite, at power plant 26 %; Electricity, hard coal, at power plant 17 %; Electricity, natural gas, at power plant 8 %; Electricity, natural gas, at power plant 8 %; Electricity, industrial gas, at power plant 5 %; Electricity, natural gas, at power plant 4 %. Most sensitive: Electricity, lignite, at power plant [DE] (-6.1 / +7.9 %); Electricity, hard coal, at power plant [DE] (-4.0 / +5.2 %); Electricity, natural gas, at power plant [FR] (-1.9 / +2.4 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.

Final control

Item Status Detail
reference flow PASS production amount 1.0 kWh
closure: sum of direct contributions = dataset score (all 25 categories) PASS largest relative gap 6.2e-16
independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh (climate change) PASS graph / published = 1; categories within ±5 %: 16/25
every technosphere input of the EcoSpold delivery is in the graph PASS all present (bafu_links_check.py)
uncertainty declared on the direct exchanges PASS 73/73 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values
Monte Carlo 95 % interval contains the deterministic score PASS 0.1275 in [0.1184, 0.1616]
time period declared PASS 2018-01/2018-12
geography is a known location code PASS CH
sources cited PASS 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them

References

  1. Stolz P., Frischknecht R. (2020) Electricity Mixes in Life Cycle Assessments of Buildings. Project report. Volume: 651. treeze Ltd.. Uster, CH. Type: Separate publication Source: Report First author: Stolz P. Other authors: Frischknecht R. Year: 2020 Title of anthology: Project report Place of publication: Uster, CH Publisher: treeze Ltd. Volume No: 651 — published source; as declared by BAFU (not found in OpenAlex/Crossref)
  2. Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — database; dataset citation
  3. International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva.
  4. Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. (tdc-doc method reference; title, version and year to verify against the user's copy)
  5. European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra.
  6. Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236

Annex — licence and terms of use

BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.