Table of Contents

Electricity mix, water utility Zug, at plant — CH

Dataset documentation and final control (tdc-doc, imported mode)
Open this dataset in OpenData

Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Electricity mix, water utility Zug, at plant [CH], per 1 kWh. EF v3.1 climate change 0.005876 kg CO2 eq (Monte Carlo 95 % interval 0.004432–0.01102). Main contributors: Electricity, hydropower, net, at reservoir power plant 47 %; Electricity, hydropower, at run-of-river power plant 23 %; Electricity, hydropower, at small hydropower plant 8 %; Electricity, at cogen 300kWth, biomethane, allocation exergy 8 %; Electricity, at cogen 1MWth, wood chips, allocation exergy 8 %; Electricity, at cogen with biogas engine, agricultural cover… 5 %. Status: final control passed.
Item Value
Dataset name Electricity mix, water utility Zug, at plant
Dataset UUID / graph id fe4c2b06-51af-3d53-8d12-5ce9bd0e0b5d / activity:electricity_mix_water_utility_zug_at_plant__ch
Reference product, unit Electricity mix, water utility Zug, at plant, 1 kWh
Location CH — Data apply to the supply area of the electric utility Obwalden.
Time period 2009-01/2013-12
Category electricity / supply mix
Source database BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1
Publisher Swiss Federal Office for the Environment (FOEN/BAFU)
Background database BAFU 2026 v1 (graph bafuquery-db)
LCIA method EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix)
Status final control passed
Documented by tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17

Introduction

The technology shares in the production mix are based on the electricity declaration of the water utility Zug in 2013. Electricity production from hydropower, biomass and nuclear power plants is further divided into specific technologies based on the Swiss electricity consumption mix in the year 2009.; UUID: fe4c2b06-51af-3d53-8d12-5ce9bd0e0b5d

This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.

Goal and scope

Function, functional unit and reference flow

Reference flow: 1 kWh of Electricity mix, water utility Zug, at plant (CH). All results are given per unit of the reference flow.

System boundary

Included are the technology shares of the electricity production at the water utility Zug at the busbar. Not included are transformation, transport or distribution losses.

Technology

Average technology per energy carrier.

Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).

LCIA method

EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.

Life cycle inventory

Inventory table

Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).

Exchange Type Location / compartment Amount Unit Uncertainty Pedigree GWP share (%) Notes
Electricity, hydropower, net, at reservoir power plant technosphere CH 0.54898 kWh lognormal, GSD² 1.07 — 47.0 █████████
Electricity, hydropower, at run-of-river power plant technosphere CH 0.3771 kWh lognormal, GSD² 1.07 — 23.3 █████
Electricity, hydropower, at small hydropower plant technosphere CH 0.10088 kWh lognormal, GSD² 1.07 — 8.1 ██
Electricity, at cogen 300kWth, biomethane, allocation exergy technosphere CH 0.0014303 kWh lognormal, GSD² 1.07 — 7.7 ██
Electricity, at cogen 1MWth, wood chips, allocation exergy technosphere CH 0.007252 kWh lognormal, GSD² 1.07 — 7.7 ██
Electricity, at cogen with biogas engine, agricultural covered, alloc. exergy technosphere CH 0.0017592 kWh lognormal, GSD² 1.07 — 4.6 █
Electricity, production mix photovoltaic, at plant technosphere CH 0.002498 kWh lognormal, GSD² 1.07 — 1.3 ·
Electricity, at wind farm technosphere CH 9.2425e-04 kWh lognormal, GSD² 1.07 — 0.3 ·

Data quality

0 of 8 direct exchanges carry a declared pedigree, 8 carry a distribution.

Field As declared by the publisher
Data generator / entry / validation data generator: Philippe Stolz (TREEZE); data entry: Philippe Stolz (TREEZE); validation (proof reading): Rolf Frischknecht (TREEZE)
extrapolations Electricity production from hydropower, biomass and nuclear power plants is further divided into specific technologies based on the Swiss electricity production mix in the year 2011.
sampling procedure Electricity declaration of the water utility Zug.
production volume na
uncertainty adjustments none
validation details Proof reading validation: 08.05.2015; Other validation: \SRV01\ESU-Docs\Projekte laufend\527 Bilanz Holzpur\EcoSpold[527-Ökobilanz-holzpur-v0.16.xlsx]X-Process;
time period comment Time of publications.

Data gaps, proxies and assumptions

None recorded.

Life cycle impact assessment (EF v3.1)

Per 1 kWh. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.

Impact category Indicator Unit Result 2.5 % 97.5 % GSD²
Acidification Accumulated Exceedance (AE) mol H+ eq 1.284e-05 1.034e-05 2.462e-05 1.54
Climate change-Biogenic Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 5.095e-04 4.095e-04 6.678e-04 1.29
Climate change-Fossil Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.004619 0.003182 0.009673 1.78
Climate change-Land use and land use change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 7.483e-04 5.108e-04 0.001095 1.51
Climate change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.005876 0.004432 0.01102 1.6
EF-particulate Matter Impact on human health disease incidence 5.391e-10 3.636e-10 1.185e-09 1.81
Ecotoxicity, freshwater_inorganics Comparative Toxic Unit for ecosystems (CTUe) CTUe 0.01169 0.009785 0.02743 1.68
Ecotoxicity, freshwater_organics Comparative Toxic Unit for ecosystems (CTUe) CTUe 4.397e-04 3.776e-04 0.001149 1.93
Ecotoxicity, freshwater Comparative Toxic Unit for ecosystems (CTUe) CTUe 0.01213 0.01019 0.02901 1.68
Eutrophication marine Fraction of nutrients reaching marine end compartment (N) kg N eq 6.790e-06 5.339e-06 1.134e-05 1.47
Eutrophication, freshwater Fraction of nutrients reaching freshwater end compartment (P) kg P eq 2.010e-06 1.184e-06 2.388e-05 4.49
Eutrophication, terrestrial Accumulated Exceedance (AE) mol N eq 1.006e-04 8.531e-05 1.485e-04 1.32
Human toxicity, cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 1.417e-12 1.165e-12 4.459e-12 1.98
Human toxicity, cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 1.118e-11 6.627e-12 2.072e-11 1.77
Human toxicity, cancer Comparative Toxic Unit for human (CTUh) CTUh 1.260e-11 8.657e-12 2.290e-11 1.65
Human toxicity, non-cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 9.217e-11 7.748e-11 2.955e-10 2
Human toxicity, non-cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 5.663e-12 4.012e-12 1.261e-11 1.8
Human toxicity, non-cancer Comparative Toxic Unit for human (CTUh) CTUh 9.783e-11 8.235e-11 3.071e-10 1.97
Ionising radiation, human health Human exposure efficiency relative to U235 kBq U235 eq 0.001176 4.144e-04 0.008471 4.59
Land use Soil quality index pt (soil quality index) 0.5593 0.3248 0.9905 1.76
Ozone depletion Ozone Depletion Potential (ODP) kg CFC-11 eq 6.657e-11 5.265e-11 1.440e-10 1.65
Photochemical ozone formation - human health Tropospheric ozone concentration increase kg NMVOC eq 2.293e-05 1.866e-05 4.046e-05 1.5
Resource use, fossils Abiotic resource depletion fossil fuels (ADP-fossil) MJ 0.04097 0.03105 0.0881 1.7
Resource use, minerals and metals Abiotic resource depletion (ADP ultimate reserve) kg Sb eq 3.327e-08 2.473e-08 7.152e-08 1.72
Water use User deprivation potential (deprivation-weighted water consumption) m3 world eq deprived 2.552e-04 -33.24 15.07 —

Climate change 0.005876 kg CO2 eq per kWh. Main contributors: Electricity, hydropower, net, at reservoir power plant 47 %; Electricity, hydropower, at run-of-river power plant 23 %; Electricity, hydropower, at small hydropower plant 8 %; Electricity, at cogen 300kWth, biomethane, allocation exergy 8 %; Electricity, at cogen 1MWth, wood chips, allocation exergy 8 %; Electricity, at cogen with biogas engine, agricultural cover… 5 %.

Interpretation

Significant issues

Direct exchanges dominating climate change: Electricity, hydropower, net, at reservoir power plant 47 %; Electricity, hydropower, at run-of-river power plant 23 %; Electricity, hydropower, at small hydropower plant 8 %; Electricity, at cogen 300kWth, biomethane, allocation exergy 8 %; Electricity, at cogen 1MWth, wood chips, allocation exergy 8 %; Electricity, at cogen with biogas engine, agricultural cover… 5 %. Most sensitive exchanges (Section 6.3): Electricity, hydropower, net, at reservoir power plant [CH] (-3.1 / +3.3 %); Electricity, hydropower, at run-of-river power plant [CH] (-1.5 / +1.6 %); Electricity, hydropower, at small hydropower plant [CH] (-0.5 / +0.6 %).

Independent recalculation

Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh:

Category Graph Published Graph / published
Acidification 1.284e-05 2.567e-05 0.500
Climate change-Biogenic 5.095e-04 5.095e-04 1.000
Climate change-Fossil 0.004619 0.004619 1.000
Climate change-Land use and land use change 7.483e-04 7.483e-04 1.000
Climate change 0.005876 0.005876 1.000
EF-particulate Matter 5.391e-10 5.391e-10 1.000
Ecotoxicity, freshwater_inorganics 0.01169 0.01195 0.979
Ecotoxicity, freshwater_organics 4.397e-04 4.372e-04 1.006
Ecotoxicity, freshwater 0.01213 0.01237 0.980
Eutrophication marine 6.790e-06 6.789e-06 1.000
Eutrophication, freshwater 2.010e-06 2.010e-06 1.000
Eutrophication, terrestrial 1.006e-04 9.828e-05 1.023
Human toxicity, cancer_inorganics 1.417e-12 1.408e-12 1.007
Human toxicity, cancer_organics 1.118e-11 1.118e-11 1.000
Human toxicity, cancer 1.260e-11 1.259e-11 1.001
Human toxicity, non-cancer_inorganics 9.217e-11 9.181e-11 1.004
Human toxicity, non-cancer_organics 5.663e-12 5.663e-12 1.000
Human toxicity, non-cancer 9.783e-11 9.748e-11 1.004
Ionising radiation, human health 0.001176 0.001176 1.000
Land use 0.5593 0.4322 1.294
Ozone depletion 6.657e-11 6.657e-11 1.000
Photochemical ozone formation - human health 2.293e-05 2.293e-05 1.000
Resource use, fossils 0.04097 0.04098 1.000
Resource use, minerals and metals 3.327e-08 3.306e-08 1.006
Water use 2.552e-04 4.460e-04 0.572
Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like.
Also published by BAFU for this dataset: IPCC 2021 GWP100 0.005876 kg CO2 eq; Ecological Scarcity
2021 total 22.4 UBP.

Sensitivity check

One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.

Exchange Base Low / high Range Δ GWP100 (%) Δ other categories (max %)
Electricity, hydropower, net, at reservoir power plant [CH] 0.549 kWh ×0.935 / ×1.07 lognormal, GSD² 1.07 -3.1 / +3.3 7.0 (Climate change-Land use and land use change)
Electricity, hydropower, at run-of-river power plant [CH] 0.3771 kWh ×0.935 / ×1.07 lognormal, GSD² 1.07 -1.5 / +1.6 2.4 (Human toxicity, non-cancer_organics)
Electricity, hydropower, at small hydropower plant [CH] 0.1009 kWh ×0.935 / ×1.07 lognormal, GSD² 1.07 -0.5 / +0.6 1.3 (Human toxicity, non-cancer_inorganics)
Electricity, at cogen 300kWth, biomethane, allocation exergy [CH] 0.00143 kWh ×0.935 / ×1.07 lognormal, GSD² 1.07 -0.5 / +0.5 3.7 (Climate change-Biogenic)
Electricity, at cogen 1MWth, wood chips, allocation exergy [CH] 0.007252 kWh ×0.935 / ×1.07 lognormal, GSD² 1.07 -0.5 / +0.5 7.2 (Land use)
Electricity, at cogen with biogas engine, agricultural covered, alloc. exergy [CH] 0.001759 kWh ×0.935 / ×1.07 lognormal, GSD² 1.07 -0.3 / +0.3 2.4 (Eutrophication, terrestrial)
Electricity, production mix photovoltaic, at plant [CH] 0.002498 kWh ×0.935 / ×1.07 lognormal, GSD² 1.07 -0.1 / +0.1 1.4 (Resource use, minerals and metals)
Electricity, at wind farm [CH] 9.243e-04 kWh ×0.935 / ×1.07 lognormal, GSD² 1.07 -0.0 / +0.0 0.1 (Resource use, minerals and metals)

Uncertainty analysis

Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.

Comparison with other data

No other location of this dataset in the graph.

Conclusions and limitations

GWP100 0.005876 kg CO2 eq per kWh (95 % interval 0.004432–0.01102). Dominant contributors: Electricity, hydropower, net, at reservoir power plant 47 %; Electricity, hydropower, at run-of-river power plant 23 %; Electricity, hydropower, at small hydropower plant 8 %; Electricity, at cogen 300kWth, biomethane, allocation exergy 8 %; Electricity, at cogen 1MWth, wood chips, allocation exergy 8 %; Electricity, at cogen with biogas engine, agricultural cover… 5 %. Most sensitive: Electricity, hydropower, net, at reservoir power plant [CH] (-3.1 / +3.3 %); Electricity, hydropower, at run-of-river power plant [CH] (-1.5 / +1.6 %); Electricity, hydropower, at small hydropower plant [CH] (-0.5 / +0.6 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.

Final control

Item Status Detail
reference flow PASS production amount 1.0 kWh
closure: sum of direct contributions = dataset score (all 25 categories) PASS largest relative gap 3.7e-16
independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh (climate change) PASS graph / published = 1; categories within ±5 %: 22/25
every technosphere input of the EcoSpold delivery is in the graph PASS all present (bafu_links_check.py)
uncertainty declared on the direct exchanges PASS 8/8 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values
Monte Carlo 95 % interval contains the deterministic score PASS 0.005876 in [0.004432, 0.01102]
time period declared PASS 2009-01/2013-12
geography is a known location code PASS CH
sources cited PASS 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them

References

  1. Stolz P., Frischknecht R. (2015) Ökobilanz Vollholzsystem holzpur. Project report. Volume: 527. treeze Ltd.. Uster, CH. Type: Separate publication Source: Report First author: Stolz P. Other authors: Frischknecht R. Year: 2015 Title of anthology: Project report Place of publication: Uster, CH Publisher: treeze Ltd. Volume No: 527 — published source; as declared by BAFU (not found in OpenAlex/Crossref)
  2. Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — database; dataset citation
  3. International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva.
  4. Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. (tdc-doc method reference; title, version and year to verify against the user's copy)
  5. European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra.
  6. Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236

Annex — licence and terms of use

BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.


To suggest a correction or a dataset that does not exist yet, use Propose a dataset.