-====== Life Cycle Inventory of Carbon fiber, PAN-based, high modulus (HM), wet spinning — Asia (RAS) ====== 
- 
-//Unit-process dataset, cradle-to-gate, 1 kg — documentation for external critical review// 
- 
-^ Item ^ Value ^ 
-| Dataset name (BAFU naming rules, DQR §4.7.1) | PAN-based carbon fiber, high modulus HM, wet spinning, from regional PAN precursor fiber, 1 kg | 
-| Dataset UUID / version | pan-based-carbon-fiber-high-modulus-hm-wet-spinning-from-regional-pan-precursor-fiber-1-kg-208c39 / draft (tdc) | 
-| Reference product, unit | Carbon fiber, PAN-based, high modulus (HM), wet spinning, kg | 
-| Location (DQR location code) | RAS — Asia | 
-| Reference year / time period | 2025 / 2025 | 
-| Technology level | current average technology (as described in the sources, Section 3) | 
-| Background database | BAFU 2026 v1 (Memgraph graph ''%%bafuquery-db%%''); no other background database | 
-| LCIA method | EF v3.1 (European Commission, Joint Research Centre 2022) (Brightway 2 / bw2calc (Mutel 2017)) | 
-| Status | ready for external review | 
-| Prepared by | tdc pipeline (datasetcreator agent), documentation and final check by tdc-doc | 
- 
-===== 1 Introduction ===== 
- 
-Oxidation carbonisation graphitisation sizing of wet-spun PAN precursor into HM carbon fiber. Region RAS. FU 1 kg. 
- 
-This report documents the dataset according to ISO 14040 (//ISO 14040:2006 Environmental Management — Life Cycle Assessment — Principles and Framework (Incl. Amd 1:2020)// 2006) and ISO 14044 (//ISO 14044:2006 Environmental Management — Life Cycle Assessment — Requirements and Guidelines (Incl. Amd 1:2017, Amd 2:2020)// 2006) and to the BAFU LCI Data Quality Requirements v2.1 (Frischknecht 2023). It is written for the external critical reviewer (ISO 14044 clause 6, ISO/TS 14071 (//ISO/TS 14071:2014 Environmental Management — Life Cycle Assessment — Critical Review Processes and Reviewer Competencies// 2014)): all calculation steps are reproducible from the files listed in Annex G, all input values are traceable to a source (reference list and verbatim excerpts in Annex D) or to a stated assumption (Section 4.6). 
- 
-===== 2 Goal and scope definition (ISO 14044, 4.2) ===== 
- 
-==== 2.1 Goal of the study ==== 
- 
-  * Intended application: background dataset for LCA studies (BAFU 2026 database extension) 
-  * Reasons for carrying out the study: missing dataset in the background database 
-  * Intended audience: LCA practitioners, external critical reviewer 
-  * Comparative assertions intended to be disclosed to the public: no 
- 
-==== 2.2 Functional unit and reference flow ==== 
- 
-The functional unit is 1 kg of product at the plant gate. Reference flow: **1 kg** of Carbon fiber, PAN-based, high modulus (HM), wet spinning at the plant gate. Product definition: Sized HM carbon fiber, 12K tow, tensile modulus 377 GPa, tensile strength 4400 MPa, C > 99%, sizing 50B 1.0%. Reference: TORAYCA M40J data sheet. [see product exchange]. 
- 
-==== 2.3 Product system and system boundary ==== 
- 
-Cradle-to-gate: raw-material and energy supply (BAFU datasets), transport to the plant, the process steps of Section 3, emissions and waste treatment. 
- 
-{{ :datasets:tdc:41de602b-4297-5a5d-984d-d6612bebbce4:chain.png?900|Product system and system boundary (unit processes, flows crossing the boundary). }} 
- 
-//Product system and system boundary (unit processes, flows crossing the boundary).// 
- 
-^ Life cycle stage ^ Included ^ Notes / source ^ 
-| Fiber stabilization, carbonization, electrolysis and washing | yes | 1.005 kg per kg product | 
-| Exhaust gas treatment 1 | yes | 37.02 kg per kg product | 
-| Exhaust gas treatment 2 (regenerative thermal oxidizer) | yes | 10.83 kg per kg product | 
-| Fiber drying and sizing | yes | 1.021 kg per kg product | 
-| Graphitisation (high-modulus grade, no benchmark counterpart) | yes | 1 kg per kg product | 
- 
-==== 2.4 Cut-off criteria ==== 
- 
-No intentional cut-off; missing items are listed as data gaps. Flows excluded by cut-off are listed with their estimated mass/energy share in Section 4.6. 
- 
-==== 2.5 Allocation procedures ==== 
- 
-No co-product allocation (single reference product). 
- 
-==== 2.6 LCIA method and impact categories ==== 
- 
-EF v3.1 (European Commission, Joint Research Centre 2022), all impact categories, characterisation only. Normalisation and weighting are not applied (optional elements, ISO 14044 4.4.3); no weighting is used for any comparison. 
- 
-==== 2.7 Data requirements and data quality requirements (ISO 14044 4.2.3.6) ==== 
- 
-^ Requirement ^ Target ^ Achieved (see Section 4.5) ^ 
-| Time-related coverage | 2020–2026 data | 2025 | 
-| Geographical coverage | Asia | 12 geographical proxy dataset(s): Chemical plant, organics: ‘Chemical plant, organics’ used at RER (no RAS version) — geographical pro; Water, process, for surface treatment and sizing: ‘Water, deionised, at plant’ used at CH (no RAS ve; Transport, freight, rail: ‘Transport, freight, rail’ used at RER (no RAS version) — geographical pro; Transport, barge: ‘Transport, barge’ used at RER (no RAS version) — geographical proxy; Transport, transoceanic freight ship: ‘Transport, transoceanic freight ship’ used at OCE (no RAS ver; Wastewater treatment, class 3: ‘Treatment, sewage, to wastewater treatment, class 3’ used at CH (no | 
-| Technology coverage | current industrial technology | Section 3 | 
-| Precision | lognormal uncertainty and pedigree on every flow (Frischknecht 2023) | lognormal on every exchange; Monte Carlo GWP100 95 % interval 71.4–87.4 | 
-| Completeness | all inventory classes (raw materials, catalyst, neutralisation, water, energy, emissions to air/water/soil, by-products, infrastructure, transport) | all classes present | 
-| Representativeness | market-weighted route and feedstock | Section 3 (market and routes) | 
-| Consistency | one modelling approach for all regions/grades | family and regional checks: ok | 
-| Reproducibility | every value computed by a tool or cited | all amounts reproduced by tdc-doc | 
-| Sources of data | ≥ 3 peer-reviewed articles (Crossref-verified), ≥ 1 patent, ≥ 1 grey document | 9 references, 6 with DOI, 2 patent(s) | 
-| Uncertainty of information | Monte Carlo on the pedigree distributions | Section 6.5 | 
- 
-==== 2.8 Assumptions and limitations ==== 
- 
-  * none recorded 
- 
-==== 2.9 Type of critical review ==== 
- 
-External critical review by an independent expert (ISO/TS 14071) — pending. 
- 
-===== 3 Product, market and technology ===== 
- 
-==== 3.1 Product definition and grades ==== 
- 
-Sized HM carbon fiber, 12K tow, tensile modulus 377 GPa, tensile strength 4400 MPa, C > 99%, sizing 50B 1.0%. Reference: TORAYCA M40J data sheet. 
- 
-==== 3.2 Market, production volumes and production routes ==== 
- 
-Region: RAS (Asia). Everything process-identical to cf-v2-hm-rer (same route, same chemistry, same per-kg stoichiometry and energy); only region-dependent items differ (electricity/heat bound to the North American grid, supply-transport region, regional market context). 
- 
-== 3.2.0.1 1. Production routes and shares == 
- 
-Carbon fiber is produced almost exclusively from polyacrylonitrile (PAN) precursor fiber. More than 90% of today’s high-performance carbon fibers are PAN-based ([[https://doi.org/10.3390/polym16010012|prenzel_2023_carbon_fiber_lca]], sec. 3.1); “at least 90% of the current carbon fiber production is based on PAN precursor fibres” ([[https://doi.org/10.1016/j.heliyon.2019.e02698|nunna_2019_cost_model_carbon_fibres]], sec. 1). Pitch-based and rayon-based CFs are marginal (few % each) and follow the same downstream stabilization/carbonization steps (prenzel_2023_carbon_fiber_lca). **The modelled route = PAN, wet-spun precursor, the dominant route worldwide.** 
- 
-The transformation from precursor to finished fiber has three heat stages: 1. oxidative stabilization in air at 200-300 C for 1-2 h (prenzel_2023_carbon_fiber_lca, sec. 3.1.1); 2. carbonization in two stages: ~1000 C low-temperature, then 1500-1800 C under inert nitrogen (sec. 3.1.2); 3. **graphitisation for high-modulus (HM) grades**, up to ~2500 C — a marginal market share but the defining step of the HM grade (sec. 3.1; also us4917836, claim of high-temperature carbonization under tension). 
- 
-== 3.2.0.2 2. Raw materials and origins == 
- 
-  * PAN precursor fiber (wet-spun): the dominant feedstock; in the global LCA model of (prenzel_2023_carbon_fiber_lca) PAN production is assumed in Japan because “Asia-Pacific region is the most relevant provider of all produced PAN worldwide (forecast 2023: 63% of global production)” (sec. 4). 
-  * Nitrogen (inert gas for carbonization): liquid nitrogen at plant in BAFU practice (see BAFU “Fiber carbonization (low temp)” / “(high temp)” inputs, 5.28 / 2.35 kg N2 per kg fiber). 
-  * Air / oxygen for the stabilization furnace. 
-  * Sizing agent (epoxy/polyurethane, water-based) at 1.0% on fiber (toray_m40j_data_sheet: sizing 50B, 1.0%). 
-  * Electrolyte for electrochemical surface treatment (prenzel_2023_carbon_fiber_lca, sec. 3.1.3). 
- 
-== 3.2.0.3 3. Production volumes (world and regional) == 
- 
-  * **World**: global average carbon fiber demand volume ~**126,500 t in 2024** ([[https://composites-united.com/wp-content/uploads/2025/03/CU-Marktbericht_2024_ENG_Kurzfassung.pdf|composites-united market report 2024]], sec. 2.1; CAGR 2010-2024 +10.07%). 
-  * **China**: annual production capacity reached **135,500 t by end-2024** ([[https://www.hongbangfrp.com/2025/02/11/analysis-of-carbon-fiber-industry-capacity-in-|hongbangfrp.com, “Analysis of Carbon Fiber Industry Capacity in 2024”]], published 2025-02-11; capacity +12.73% year-on-year, new capacity concentrated in Shandong/Jiangsu/Hebei; mainly T300/T700 level, 12K/24K plus “a small amount of high-strength and high-modulus products”). 
-  * **Asia-Pacific** ~63% of global PAN production (forecast 2023, cited in prenzel_2023_carbon_fiber_lca, sec. 4). 
-  * **Asia (RAS)**: dominant producing region — China (capacity 135,500 t end-2024, hongbangfrp.com) plus Japan (Toray M40J manufactured in “Japan and France”, toray_m40j_data_sheet; Toray is a main CF producer) and Korea (Toppan/Unitika, major sizing-precursor suppliers). Asia-Pacific is ~63% of global PAN production (forecast 2023, prenzel_2023_carbon_fiber_lca, sec. 4) and the main CF production region. 
-  * Main producing regions for CF: Asia (China, Japan), North America (USA: Toray/Hexcel plants), Europe (France: Toray M40J; SGL carbon plants in DE). 
- 
-== 3.2.0.4 4. Grade context (HM vs HT) == 
- 
-Most produced carbon fibers are standard (high-tenacity, HT) grade; high-modulus is a differentiated product (prenzel_2023_carbon_fiber_lca). Reference HM product: TORAYCA M40J — MJ-type high modulus, tensile modulus **377 GPa**, tensile strength 4400 MPa, strain at failure 1.2%, carbon >99%, sizing 50B 1.0%, manufactured in Japan and France (toray_m40j_data_sheet). This defines the grade modelled in cf-v2-hm-*. 
- 
-== 3.2.0.5 5. Modelling decision (RAS) == 
- 
-  * Route: PAN wet-spun precursor -> stabilization -> carbonization (low-T + high-T/graphitisation) -> surface treatment + sizing -> winding (dominant route and grade, largest-volume precursor family). 
-  * Region: RAS (Asia). Electricity and heat inputs are bound to the Asian BAFU grid/heat sets (“Electricity, medium voltage, production RAS, at grid”; “Heat, unspecific, in chemical plant” RAS); supply transport uses the RAS region in tdc-calc supply_transport (UN Comtrade 2024, hub Shanghai). 
-  * Precursor: ''%%PAN precursor fiber, wet spun%%'' via ''%%uses%%'' -> cf-v2-precursor-rer (shared upstream dataset; no BAFU binding; LCIA inherited). 
-  * Alternative route (pitch-based CF) NOT modelled: <10% of the market and not the product requested. 
- 
-^ Item ^ Value ^ Year ^ Source ^ 
- 
-==== 3.3 Process description ==== 
- 
-Oxidation carbonisation graphitisation sizing of wet-spun PAN precursor into HM carbon fiber. Region RAS. FU 1 kg. Processing steps as recorded in the unit process: 
- 
-^ Step ^ Conditions (T, p, time) ^ Main inputs/outputs ^ Source ^ 
-| Feed and unwinding of PAN precursor fiber | The wet-spun PAN precursor fiber (tow) is fed from the regional precursor spools onto the fiber oven system; continuous fiber feeding at controlled tension and speed. |  | [] | 
-| Oxidation / stabilization | The precursor fiber is heated in air at 250-300 C to stabilize and ladder the polyacrylonitrile structure; exothermic conversion that removes volatile nitrogen- and hydrogen-bearing species (HCN, NH3, H2O). |  | [] | 
-| Low-temperature carbonization | The stabilized fiber is heated under an inert atmosphere (nitrogen) at 400-600 C; remaining hydrogen, nitrogen and oxygen are released as CO, CO2, HCN, NH3, H2O, CH4 and N2, converting the fiber into a carbon-rich structure. |  | [] | 
-| High-temperature carbonization / graphitisation | For the high-modulus grade the fiber is heated under inert gas at elevated temperature (up to ~2500 C) under high longitudinal draw tension to grow and align the graphitic crystallites, giving the high tensile modulus. |  | [] | 
-| Surface treatment and sizing | The carbon fiber surface is treated (chemical/electrochemical) to improve matrix adhesion, a polymeric sizing agent is applied and the fiber is dried. |  | [] | 
-| Winding and packaging | The sized carbon fiber is wound onto spools and packaged; fiber dust and soot are collected and handled as solid waste. |  | [] | 
-| Exhaust gas treatment | The oven and graphitisation exhaust gases are treated (oxidation/scrubbing) to destroy residual HCN, NOx and other toxic/combustible species before release to ambient air. |  | [] | 
- 
-===== 4 Life cycle inventory analysis (ISO 14044, 4.3) ===== 
- 
-==== 4.1 Data collection ==== 
- 
-Two-step literature search: (1) the user’s embedded reference library (local vector search, — queries, 0 excerpts retained), then (2) a web and database round (scholarly indexes, patents, agency and industry documents) to complete the process description. Each reference was verified (DOI against Crossref; patents against the patent office record; other documents fetched and the quoted passage found in the text). Reference statistics: 9 references, 6 Crossref-verified articles, 2 patents, 1 grey documents. 
- 
-==== 4.2 Calculation procedures ==== 
- 
-=== 4.2.1 Stoichiometry and mass/element balances === 
- 
-Stoichiometric model of the dataset (spec.json), recomputed by tdc-doc: balances pass. Balances computed by the tdc stoichiometry model (Annex B): 
- 
-^ Balance ^ In (kg) ^ Out (kg) ^ Residual (%) ^ 
-| C | — | — | -0 | 
-| H | — | — | -0 | 
-| N | — | — | 0 | 
-| O | — | — | -0 | 
-| mass | — | — | -0 | 
- 
-=== 4.2.2 Energy model === 
- 
-Heat and electricity are computed per consumer from process physics with the tdc energy model (Annex A); each parameter is cited or declared as an assumption. 
- 
-^ Consumer ^ Energy form ^ Duty / power ^ Time ^ Energy per kg ^ Source ^ 
-| [Fiber stabilization, carbonization, electrolysis and washing] Fiber sensible heat, stabilization (25 to 300 C) | heat (electric) | — | — | 1.15 MJ | [Precursor mass 2.7885 kg per kg of core fiber (per-kg-core value defined on the cap-era C-fraction 2.74386/0.984); the dataset’s sourced pre] | 
-| [Fiber stabilization, carbonization, electrolysis and washing] Stabilization oven air heating (recirculating oxidizer air) | heat (electric) | — | — | 36.37 MJ | [‘the air is heated in an electric heater to a predetermined temperature and heats the processed fibers due to convective heat exchange’ (IJA] | 
-| [Fiber stabilization, carbonization, electrolysis and washing] Fiber sensible heat, low-temperature carbonization (300 to 1000 C) | heat (electric) | — | — | 1.757 MJ | [Stabilized fiber 2.5096 kg per kg core (2.4695 kg per kg product / 0.984; grade-common 10% stabilization mass loss on the cap-era precursor ] | 
-| [Fiber stabilization, carbonization, electrolysis and washing] Fiber sensible heat, high-temperature carbonization (1000 to 1800 C) | heat (electric) | — | — | 1.004 MJ | [Mid-route fiber 1.2548 kg per kg core (1.2347 kg per kg product / 0.984; grade-common 50% LT-carbonisation loss; DATA GAP - same harmonizing] | 
-| [Fiber stabilization, carbonization, electrolysis and washing] Carbonisation + surface-treatment stage powers: N2 purge heating, wall losses, electrolysis, drives (sourced RSC stage kW residual) | heat (electric) | — | — | 29.08 MJ | [RSC_ESI_2016 Table 1 sourced stage powers. SHARED grade-common physics of the cf-pan-ws-v2 family (same ~29 MJ as IM/UHM-rer).] | 
-| [Fiber stabilization, carbonization, electrolysis and washing] Stabilization furnace NG burner (on-site gas assist, 0.22 kg NG per kg product) | heat (fuel) | — | — | 6.695 MJ | [Sourced on-site NG for the stabilization oxidation furnace (carrier fuel). Per user decision 4 the on-site fuel is carried by the energy mod] | 
-| [Fiber stabilization, carbonization, electrolysis and washing] Inert gas make-up compression (N2, slight overpressure of the carbonisation atmospheres) | electricity | 0.4109 | 1 | 0.4109 kWh | [All nitrogen purchased externally (JapanCFMA_LCI_2022 sec 5-3-6: ‘All nitrogen was purchased externally’); inert N2 for carbonisation (Prenz] | 
-| [Fiber stabilization, carbonization, electrolysis and washing] Fiber line tensioner drives, furnace drive trains, electrolysis and washing drives | electricity | 3.378 | 1 | 3.378 kWh | [Continuous line under constant tension (Prenzel2023 sec 3.1.1) with drive trains per furnace; 3.04 kW per kg/h of core (3 kW per kg/h produc] | 
-| [Exhaust gas treatment 1] First off-gas treatment (quench/wash/scrubber) specific energy | electricity (utility) | — | — | 0.023 kWh | [First exhaust-gas treatment of the continuous CF line (before the RTO); BAFU dataset ‘Carbon fiber production, exhaust gas treatment 1’ has ] | 
-| [Exhaust gas treatment 2 (regenerative thermal oxidizer)] Regenerative thermal oxidizer NG fuel (on-site, 2.06 kg NG per kg product) | heat (fuel) | — | — | 5.908 MJ | [Sourced on-site RTO fuel (carrier fuel). Per user decision 4 carried by the energy model fuel_supply as BAFU heat per MJ. This plus the step] | 
-| [Exhaust gas treatment 2 (regenerative thermal oxidizer)] RTO fans and blower (off-gas and oxidising-air circulation) | electricity (utility) | — | — | 0.0262 kWh | [RTO fans and post-treatment blower of the regenerative thermal oxidizer; the sourced RSC_ESI_2016 abatement system (25 kW at 12.5 kg/h) incl] | 
-| [Fiber drying and sizing] Sizing-bath water heating (technical drying, recovered closed loop) | heat (electric) | — | — | 1.2 MJ | [The sizing-bath water is a recovered closed loop: ’the water evaporates in technical drying, is recovered and fed back; the coating remains ] | 
-| [Fiber drying and sizing] Drying air handling + winding drives (sourced RSC stage powers) | electricity | 1.2 | 1 | 1.2 kWh | [RSC_ESI_2016 Table 1 sourced stage powers (measured, 100 t/a pilot line) - INDEPENDENT of the Benitez2021 benchmark. SHARED winding/drying e] | 
-| [Graphitisation (high-modulus grade, no benchmark counterpart)] Graphitisation furnace electric power, HM grade (graphite-block furnace at 2000-2800 C) | electricity | 20 | 1 | 20 kWh | [YongXian2026 sourced specific power range (the defining energy sink of the high-modulus grades). No HM graphitisation furnace dimensions, U-] | 
- 
-Totals per kg: heat 70.74 MJ, electricity 49.35 kWh, primary energy — MJ. 
- 
-=== 4.2.3 Emissions === 
- 
-Direct emissions: Nitrogen, off-gas (to air) 0.7345 kg; Carbon dioxide, fossil (to air) 3.155 kg; Water, off-gas vapor (to air) 1.411 kg; Nitrogen oxides, fossil (to air) 0.00012 kg; Hydrogen cyanide (to air) 0.00191 kg; Carbon monoxide, fossil (to air) 0.1339 kg; Ammonia (to air) 0.001357 kg; Methane (to air) 0.001717 kg; Ethylene (to air) 0.001711 kg; Ethane (to air) 0.001714 kg; Nitrogen, liquid, at plant (to air) 8.822 kg. 
- 
-=== 4.2.4 Transport === 
- 
-Statistical transport from the provenance of each raw material to the plant region (Annex C): Transport, freight, rail 0.01056 tkm; Transport, barge 0.01188 tkm; Transport, transoceanic freight ship 0.1113 tkm; Transport, freight, lorry, diesel, 40t gross weight, 2006, EURO-IV, long haul 0.0117 tkm 
- 
-=== 4.2.5 Infrastructure === 
- 
-Chemical plant, organics 1.2e-09 p 
- 
-==== 4.3 Inventory table ==== 
- 
-Per 1 kg of product. GSD² = squared geometric standard deviation of the lognormal distribution; pedigree scores (reliability, completeness, temporal, geographical, technological) per BAFU DQR v2.1 (Frischknecht 2023). 
- 
-^ Exchange ^ Direction ^ Amount ^ Unit ^ BAFU dataset / elementary flow ^ GSD² ^ Pedigree ^ Source ^ 
-| Nitrogen, off-gas (to air) | output | 0.73455 | kg | Nitrogen | 1.57 | (4,3,2,1,1) | [—] | 
-| Chemical plant, organics | input | 1.2e-09 | p | Chemical plant, organics [RER] | 3.06 | (4,3,3,1,1) | [—] | 
-| Water, process, for surface treatment and sizing | input | 5.5 | kg | Water, deionised, at plant [CH] | 1.13 | (3,3,2,1,1) | [—] | 
-| Transport, freight, rail | input | 0.010565 | tkm | Transport, freight, rail [RER] | 2.02 | (3,3,2,2,1) | [—] | 
-| Transport, barge | input | 0.011885 | tkm | Transport, barge [RER] | 2.02 | (3,3,2,2,1) | [—] | 
-| Transport, transoceanic freight ship | input | 0.11131 | tkm | Transport, transoceanic freight ship [OCE] | 2.02 | (3,3,2,2,1) | [—] | 
-| Wastewater treatment, class 3 | input | 0.0055 | m3 | Treatment, sewage, to wastewater treatment, class 3 [CH] | 1.13 | (3,3,2,1,1) | [—] | 
-| Transport, freight, lorry, diesel, 40t gross weight, 2006, EURO-IV, long haul | input | 0.011703 | tkm | Transport, freight, lorry, diesel, 40t gross weight, 2006, EURO-IV, long haul [RER] | 3.02 | (3,3,2,2,1) | [—] | 
-| Sizing agent, epoxy | input | 0.016 | kg | Epoxy resin, liquid, at plant [RER] | 1.13 | (3,3,2,1,1) | [—] | 
-| Oxygen, resource in air | input | 3.6248 | kg | Oxygen | 1.22 | (4,3,2,1,1) | [—] | 
-| Nitrogen, liquid, at plant | input | 8.822 | kg | Nitrogen, liquid, at plant [RER] | 1.13 | (3,3,2,1,1) | [—] | 
-| Ammonium bicarbonate, at plant | input | 0.01842 | kg | Ammonium bicarbonate, at plant [RER] | 1.13 | (3,3,2,1,1) | [—] | 
-| Ethylene glycol, at plant | input | 0.0076 | kg | Ethylene glycol, at plant [RER] | 1.13 | (3,3,2,1,1) | [—] | 
-| Carbon dioxide, fossil (to air) | output | 3.1553 | kg | Carbon dioxide, fossil | 1.22 | (4,3,2,1,1) | [—] | 
-| Water, off-gas vapor (to air) | output | 1.4107 | kg | Water | 1.57 | (4,3,2,1,1) | [—] | 
-| Nitrogen oxides, fossil (to air) | output | 0.00012 | kg | Nitrogen oxides | 1.57 | (4,3,2,1,1) | [—] | 
-| Hydrogen cyanide (to air) | output | 0.00191 | kg | Cyanide | 1.57 | (4,3,2,1,1) | [—] | 
-| Carbon monoxide, fossil (to air) | output | 0.13386 | kg | Carbon monoxide, fossil | 5.06 | (4,3,2,1,1) | [—] | 
-| Ammonia (to air) | output | 0.001357 | kg | Ammonia | 1.57 | (4,3,2,1,1) | [—] | 
-| Methane (to air) | output | 0.001717 | kg | Methane, fossil | 1.57 | (4,3,2,1,1) | [—] | 
-| Ethylene (to air) | output | 0.001711 | kg | NMVOC, non-methane volatile organic compounds | 1.57 | (4,3,2,1,1) | [—] | 
-| Ethane (to air) | output | 0.001714 | kg | Ethane | 2.05 | (4,3,2,1,1) | [—] | 
-| Electricity, medium voltage, at grid | input | 49.346 | kWh | Electricity, medium voltage, production RAS, at grid [RAS] | 1.13 | (3,3,2,1,1) | [—] | 
-| Heat, natural gas, at heat plant | input | 70.742 | MJ | Natural gas, burned in boiler modulating >100kW [RER] | 1.13 | (3,3,2,1,1) | [—] | 
-| Nitrogen, liquid, at plant (to air) | output | 8.822 | kg | Nitrogen | 1.57 | (4,3,2,1,1) | [—] | 
-| PAN precursor fiber, wet spun | input | 2.802 | kg | tdc dataset cf-v2-precursor-ras | 1.22 | (4,3,2,1,1) | [—] | 
- 
-==== 4.4 Data quality assessment ==== 
- 
-Energy verification per sub-process (policy B): Fiber stabilization, carbonization, electrolysis and washing: physics, 3 independent reference(s); Exhaust gas treatment 1: literature, 1 independent reference(s); Exhaust gas treatment 2 (regenerative thermal oxidizer): literature, 2 independent reference(s); Fiber drying and sizing: literature, 3 independent reference(s); Graphitisation (high-modulus grade, no benchmark counterpart): literature, 1 independent reference(s). Pedigree scores: 26 of 26 exchanges scored by the developer; the others carry the tdc-doc default (3, 3, 3, 3, 3) (marked *). Proxies (BAFU datasets that do not represent exactly the flow): Chemical plant, organics → Chemical plant, organics (Chemical plant, organics: ‘Chemical plant, organics’ used at RER (no RAS version) — geographical proxy); Water, process, for surface treatment and sizing → Water, deionised, at plant (Water, process, for surface treatment and sizing: ‘Water, deionised, at plant’ used at CH (no RAS version) — geographical proxy); Transport, freight, rail → Transport, freight, rail (Transport, freight, rail: ‘Transport, freight, rail’ used at RER (no RAS version) — geographical proxy); Transport, barge → Transport, barge (Transport, barge: ‘Transport, barge’ used at RER (no RAS version) — geographical proxy); Transport, transoceanic freight ship → Transport, transoceanic freight ship (Transport, transoceanic freight ship: ‘Transport, transoceanic freight ship’ used at OCE (no RAS version) — geographical proxy); Wastewater treatment, class 3 → Treatment, sewage, to wastewater treatment, class 3 (Wastewater treatment, class 3: ‘Treatment, sewage, to wastewater treatment, class 3’ used at CH (no RAS version) — geographical proxy); Transport, freight, lorry, diesel, 40t gross weight, 2006, EURO-IV, long haul → Transport, freight, lorry, diesel, 40t gross weight, 2006, EURO-IV, long haul (Transport, freight, lorry, diesel, 40t gross weight, 2006, EURO-IV, long haul: ‘Transport, freight, lorry, diesel, 40t gross weight, 2006, EURO-IV, long haul’ used at RER (no RAS version) — geographic); Sizing agent, epoxy → Epoxy resin, liquid, at plant (Sizing agent, epoxy: ‘Epoxy resin, liquid, at plant’ used at RER (no RAS version) — geographical proxy); Nitrogen, liquid, at plant → Nitrogen, liquid, at plant (Nitrogen, liquid, at plant: ‘Nitrogen, liquid, at plant’ used at RER (no RAS version) — geographical proxy); Ammonium bicarbonate, at plant → Ammonium bicarbonate, at plant (Ammonium bicarbonate, at plant: ‘Ammonium bicarbonate, at plant’ used at RER (no RAS version) — geographical proxy); Ethylene glycol, at plant → Ethylene glycol, at plant (Ethylene glycol, at plant: ‘Ethylene glycol, at plant’ used at RER (no RAS version) — geographical proxy); Heat, natural gas, at heat plant → Natural gas, burned in boiler modulating >100kW (Heat, natural gas, at heat plant: ‘Natural gas, burned in boiler modulating >100kW’ used at RER (no RAS version) — geographical proxy). 
- 
-==== 4.5 Data gaps and assumptions register ==== 
- 
-^ Item ^ Class ^ Value used ^ Reason / queries tried ^ Effect (Section 6.3) ^ 
- 
-==== 4.6 Validation of data (ISO 14044 4.3.3.2) ==== 
- 
-  * Mass and element balances: Section 4.2.1. 
-  * Cross-check with independent data: BAFU datasets of similar processes (Carbon fiber production, fiber stabilization, carbonization, electrolysis and washing, Carbon fiber production, exhaust gas treatment 1, Carbon fiber production, fiber drying and sizing, Carbon fiber production, fiber stabilization, carbonization, electrolysis and washing, Carbon fiber production, exhaust gas treatment 1, Carbon fiber production, fiber drying and sizing, Carbon fiber production, fiber stabilization, carbonization, electrolysis and washing, Carbon fiber production, exhaust gas treatment 1, Carbon fiber production, fiber drying and sizing, Carbon fiber production, fiber stabilization, carbonization, electrolysis and washing, Carbon fiber production, exhaust gas treatment 1, Carbon fiber production, fiber drying and sizing) and published values (Section 6.6); deviations beyond a factor of 3 are justified with a cited excerpt. 
-  * Independent second-model review (Gemma-4-26B-A4B-it-GGUF): 2 finding(s), review of 2026-10-28 04:34 (Annex E). 
-  * Citation test: every quoted excerpt was found in its source text (all found). 
-  * Independent recalculation by tdc-doc: independent recalculation of GWP100 = pipeline LCIA (lcia.json): PASS. 
- 
-===== 5 Life cycle impact assessment (EF v3.1) ===== 
- 
-Characterisation results per 1 kg, computed with bw2calc on the BAFU 2026 v1 database (Mutel 2017; European Commission, Joint Research Centre 2022). 
- 
-^ Impact category ^ Indicator ^ Unit ^ Result ^ 
-| acidification | accumulated exceedance (AE) | mol H+-Eq | 0.2006 | 
-| climate change | global warming potential (GWP100) | kg CO2-Eq | 78.46 | 
-| climate change: biogenic | global warming potential (GWP100) | kg CO2-Eq | 0.2354 | 
-| climate change: fossil | global warming potential (GWP100) | kg CO2-Eq | 78.21 | 
-| climate change: land use and land use change | global warming potential (GWP100) | kg CO2-Eq | 0.0109 | 
-| ecotoxicity: freshwater | comparative toxic unit for ecosystems (CTUe) | CTUe | 294 | 
-| ecotoxicity: freshwater, inorganics | comparative toxic unit for ecosystems (CTUe) | CTUe | 270.3 | 
-| ecotoxicity: freshwater, organics | comparative toxic unit for ecosystems (CTUe) | CTUe | 23.71 | 
-| energy resources: non-renewable | abiotic depletion potential (ADP): fossil fuels | MJ, net calorific value | 1154 | 
-| eutrophication: freshwater | fraction of nutrients reaching freshwater end compartment (P) | kg P-Eq | 0.01768 | 
-| eutrophication: marine | fraction of nutrients reaching marine end compartment (N) | kg N-Eq | 0.03254 | 
-| eutrophication: terrestrial | accumulated exceedance (AE) | mol N-Eq | 0.4845 | 
-| human toxicity: carcinogenic | comparative toxic unit for human (CTUh) | CTUh | 3.114e-08 | 
-| human toxicity: carcinogenic, inorganics | comparative toxic unit for human (CTUh) | CTUh | 1.443e-08 | 
-| human toxicity: carcinogenic, organics | comparative toxic unit for human (CTUh) | CTUh | 1.671e-08 | 
-| human toxicity: non-carcinogenic | comparative toxic unit for human (CTUh) | CTUh | 7.254e-07 | 
-| human toxicity: non-carcinogenic, inorganics | comparative toxic unit for human (CTUh) | CTUh | 7.049e-07 | 
-| human toxicity: non-carcinogenic, organics | comparative toxic unit for human (CTUh) | CTUh | 2.048e-08 | 
-| ionising radiation: human health | human exposure efficiency relative to u235 | kBq U235-Eq | 11.3 | 
-| land use | soil quality index | dimensionless | 207.2 | 
-| material resources: metals/minerals | abiotic depletion potential (ADP): elements (ultimate reserves) | kg Sb-Eq | 7.416e-05 | 
-| ozone depletion | ozone depletion potential (ODP) | kg CFC-11-Eq | 1.122e-06 | 
-| particulate matter formation | impact on human health | disease incidence | 1.783e-06 | 
-| photochemical oxidant formation: human health | tropospheric ozone concentration increase | kg NMVOC-Eq | 0.1321 | 
-| water use | user deprivation potential (deprivation-weighted water consumption) | m3 world eq. deprived | 7.524 | 
- 
-{{ :datasets:tdc:41de602b-4297-5a5d-984d-d6612bebbce4:contribution.png?900|Contribution of the inventory items to climate change (GWP100) and the other main categories. }} 
- 
-//Contribution of the inventory items to climate change (GWP100) and the other main categories.// 
- 
-Climate change 78.46 kg CO2-eq per kg. Main contributors: Electricity, medium voltage, at grid 46 %; PAN precursor fiber, wet spun 41 %; Heat, natural gas, at heat plant 7 %; Carbon dioxide, fossil (to air) 4 %; Nitrogen, liquid, at plant 3 %. 
- 
-===== 6 Interpretation (ISO 14044, 4.5) ===== 
- 
-==== 6.1 Significant issues ==== 
- 
-The inventory items that dominate climate change are Electricity, medium voltage, at grid 46 %; PAN precursor fiber, wet spun 41 %; Heat, natural gas, at heat plant 7 %; Carbon dioxide, fossil (to air) 4 %; Nitrogen, liquid, at plant 3 %. The parameters with the largest effect (Section 6.3) are: Graphitisation (high-modulus grade, no benchmark counterpart): electricity_kWh (per kg step output) (-11 / +0 %); PAN precursor fiber, wet spun (pedigree 95 % interval) (-7 / +9 %); Electricity, medium voltage, at grid (pedigree 95 % interval) (-5 / +6 %). 
- 
-==== 6.2 Completeness check ==== 
- 
-board stage ‘inventory’ (closed + automatic check re-run): PASS; inventory completeness (classes, no zero amounts): PASS; every exchange scored in EF v3.1 (linked to BAFU / biosphere): PASS 
- 
-==== 6.3 Sensitivity check ==== 
- 
-One-at-a-time variation of (a) every assumption of Section 4.6 over its plausible range and (b) every parameter for which the literature gives a range or several values (Annex D); scenarios for alternative routes, feedstocks and regions. 
- 
-^ Parameter ^ Base ^ Low / high ^ Source of the range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ 
-| Graphitisation (high-modulus grade, no benchmark counterpart): electricity_kWh (per kg step output) | 20.0 | 8.0 / 20.0 | [Li2024 (Applied Sciences 2024, 14(6):2528, inducti; YongXian2026 sourced specific power range 15-35 kW] | -11.1 / +0.0 | 18.7 | 
-| PAN precursor fiber, wet spun (pedigree 95 % interval) | 2.80201 | /1.22 / x1.22 | [pedigree (Annex H)] | -7.3 / +8.9 | 20.4 | 
-| Electricity, medium voltage, at grid (pedigree 95 % interval) | 49.34552 | /1.13 / x1.13 | [pedigree (Annex H)] | -5.2 / +5.9 | 9.9 | 
-| Fiber stabilization, carbonization, electrolysis and washing: electricity_kWh (per kg step output) | 26.4559 | 28.2264 / 28.2264 | [Benitez A, Wulf C, de Palmenaer A, et al. Ecologic] | +1.6 / +1.6 | 2.8 | 
-| Exhaust gas treatment 2 (regenerative thermal oxidizer): electricity_kWh (per kg step output) | 0.0262 | 0.0262 / 0.1885 | [Benitez A, Wulf C, de Palmenaer A, et al. Ecologic; RSC_ESI_2016 Table 1 ‘Abatement system 25 kW’ at 1] | +0.0 / +1.6 | 2.7 | 
-| Fiber drying and sizing: electricity_kWh (per kg step output) | 1.5922 | 0.6257 / 0.6257 | [Benitez A, Wulf C, de Palmenaer A, et al. Ecologic] | -0.9 / -0.9 | 1.5 | 
-| Carbon dioxide, fossil (to air) (pedigree 95 % interval) | 3.15527 | /1.22 / x1.22 | [pedigree (Annex H)] | -0.7 / +0.9 | 0.9 | 
-| Heat, natural gas, at heat plant (pedigree 95 % interval) | 70.74159 | /1.13 / x1.13 | [pedigree (Annex H)] | -0.8 / +0.8 | 2.2 | 
-| Nitrogen, liquid, at plant (pedigree 95 % interval) | 8.822 | /1.13 / x1.13 | [pedigree (Annex H)] | -0.3 / +0.3 | 3.0 | 
-| Chemical plant, organics (pedigree 95 % interval) | 0.0 | /3.06 / x3.06 | [pedigree (Annex H)] | -0.1 / +0.3 | 28.1 | 
-| Exhaust gas treatment 1: electricity_kWh (per kg step output) | 0.023 | 0.02 / 0.0229 | [Benitez A, Wulf C, de Palmenaer A, et al. Ecologic; Benitez2021 benchmark sub-process ‘carbon fiber pr; RSC_ESI_2016 Table 1 ’Abatement system 25 kW’ at 1] | -0.1 / -0.0 | 0.2 | 
- 
-==== 6.4 Consistency check ==== 
- 
-Final control: 22 item(s) passed; no failure. 
- 
-==== 6.5 Uncertainty analysis ==== 
- 
-Monte Carlo simulation (1000 runs) on the lognormal distributions of all exchanges: 
- 
-^ Impact category ^ Median ^ 2.5 % ^ 97.5 % ^ GSD² ^ 
-| acidification / accumulated exceedance (AE) | 0.2018 | 0.1803 | 0.2274 | 1.12 | 
-| climate change / global warming potential (GWP100) | 78.81 | 71.37 | 87.39 | 1.11 | 
-| climate change: biogenic / global warming potential (GWP100) | 0.2364 | 0.217 | 0.2572 | 1.09 | 
-| climate change: fossil / global warming potential (GWP100) | 78.56 | 71.14 | 87.13 | 1.11 | 
-| climate change: land use and land use change / global warming potential (GWP100) | 0.01096 | 0.00993 | 0.01215 | 1.11 | 
-| ecotoxicity: freshwater / comparative toxic unit for ecosystems (CTUe) | 295.5 | 263.4 | 333.8 | 1.13 | 
-| ecotoxicity: freshwater, inorganics / comparative toxic unit for ecosystems (CTUe) | 271.7 | 242.9 | 305.6 | 1.12 | 
-| ecotoxicity: freshwater, organics / comparative toxic unit for ecosystems (CTUe) | 23.87 | 19.69 | 28.71 | 1.21 | 
-| energy resources: non-renewable / abiotic depletion potential (ADP): fossil fuels | 1160 | 1039 | 1301 | 1.12 | 
-| eutrophication: freshwater / fraction of nutrients reaching freshwater end compartment (P) | 0.01776 | 0.01629 | 0.0194 | 1.09 | 
-| eutrophication: marine / fraction of nutrients reaching marine end compartment (N) | 0.03269 | 0.02955 | 0.03638 | 1.11 | 
-| eutrophication: terrestrial / accumulated exceedance (AE) | 0.4878 | 0.4339 | 0.5532 | 1.13 | 
-| human toxicity: carcinogenic / comparative toxic unit for human (CTUh) | 3.129e-08 | 2.859e-08 | 3.429e-08 | 1.1 | 
-| human toxicity: carcinogenic, inorganics / comparative toxic unit for human (CTUh) | 1.452e-08 | 1.32e-08 | 1.608e-08 | 1.1 | 
-| human toxicity: carcinogenic, organics / comparative toxic unit for human (CTUh) | 1.676e-08 | 1.538e-08 | 1.835e-08 | 1.09 | 
-| human toxicity: non-carcinogenic / comparative toxic unit for human (CTUh) | 7.285e-07 | 6.635e-07 | 8.022e-07 | 1.1 | 
-| human toxicity: non-carcinogenic, inorganics / comparative toxic unit for human (CTUh) | 7.08e-07 | 6.442e-07 | 7.803e-07 | 1.1 | 
-| human toxicity: non-carcinogenic, organics / comparative toxic unit for human (CTUh) | 2.068e-08 | 1.851e-08 | 2.337e-08 | 1.12 | 
-| ionising radiation: human health / human exposure efficiency relative to u235 | 11.37 | 10.37 | 12.48 | 1.1 | 
-| land use / soil quality index | 207.9 | 190.8 | 228.1 | 1.09 | 
-| material resources: metals/minerals / abiotic depletion potential (ADP): elements (ultimate reserves) | 7.504e-05 | 6.348e-05 | 9.537e-05 | 1.23 | 
-| ozone depletion / ozone depletion potential (ODP) | 1.127e-06 | 1e-06 | 1.286e-06 | 1.13 | 
-| particulate matter formation / impact on human health | 1.793e-06 | 1.603e-06 | 2.021e-06 | 1.12 | 
-| photochemical oxidant formation: human health / tropospheric ozone concentration increase | 0.1342 | 0.1195 | 0.1584 | 1.15 | 
-| water use / user deprivation potential (deprivation-weighted water consumption) | 7.551 | 6.903 | 8.292 | 1.1 | 
- 
-==== 6.6 Comparison with other data ==== 
- 
-^ Source ^ Scope ^ Value (GWP100 or energy) ^ This dataset ^ Ratio ^ Explanation ^ 
-| [BAFU 2026 dataset] | Carbon fiber, weaved, at factory (RER), cradle-to-gate incl. weaving | 51.5 kg CO2-eq | 78.5 | 1.52 | BAFU analog (Benitez 2021 inventory); includes weaving | 
-| [tdc dataset] | cf-v2-hm-rer (same product, other region) | 56.8 kg CO2-eq | 78.5 | 1.38 | regional variant (electricity, heat, transport) | 
-| [tdc dataset] | cf-v2-hm-rna (same product, other region) | 59.3 kg CO2-eq | 78.5 | 1.32 | regional variant (electricity, heat, transport) | 
-| [Benitez et al. 2021] | electricity, whole CF chain incl. precursor (per kg CF) | 43.2388 kWh | 49.3 kWh (this unit process) | — | different boundary when the precursor is a separate dataset | 
- 
-==== 6.7 Conclusions, limitations and recommendations ==== 
- 
-GWP100 78.5 kg CO2-eq per kg (95 % interval 71.4–87.4). Dominant contributors: Electricity, medium voltage, at grid 46 %; PAN precursor fiber, wet spun 41 %; Heat, natural gas, at heat plant 7 %; Carbon dioxide, fossil (to air) 4 %; Nitrogen, liquid, at plant 3 %. Most sensitive parameters: Graphitisation (high-modulus grade, no benchmark counterpart): electricity_kWh (per kg step output) (-11 / +0 %); PAN precursor fiber, wet spun (pedigree 95 % interval) (-7 / +9 %); Electricity, medium voltage, at grid (pedigree 95 % interval) (-5 / +6 %). Dataset status: ready for external review. 
- 
-===== 7 Critical review ===== 
- 
-//Reserved for the external reviewer (ISO 14044 clause 6; ISO/TS 14071 (//ISO/TS 14071:2014 Environmental Management — Life Cycle Assessment — Critical Review Processes and Reviewer Competencies// 2014)): reviewer, date, scope of the review, statement, and the response of the dataset developers.// 
- 
-^ Reviewer comment ^ Response ^ Change in the dataset ^ 
-|  |  |  | 
- 
-===== 8 References ===== 
- 
-Bell, Caleb. 2016a. //Fluids: Fluid Dynamics Component of Chemical Engineering Design Library (ChEDL)//. Released. [[https://github.com/CalebBell/fluids]]. 
- 
-Bell, Caleb. 2016b. //Thermo: Chemical Properties Component of Chemical Engineering Design Library (ChEDL)//. Released. [[https://github.com/CalebBell/thermo]]. 
- 
-Benitez A, Wulf C, de Palmenaer A, Lengersdorf M, Röding T, Grube T, et al. 2021. ‘Ecological Assessment of Fuel Cell Electric Vehicles with Special Focus on Type IV Carbon Fiber Hydrogen Tank’. //Journal of Cleaner Production// 278: 123277. [[https://doi.org/10.1016/j.jclepro.2020.123277]]. 
- 
-Bo Guan et al. 2025. ‘Design and Numerical Study of Induction-Heating Graphitization Furnace Based on Graphene Coils’. //Materials//, ahead of print. [[https://doi.org/10.3390/ma18040528]]. 
- 
-Commission Recommendation (EU) 2021/2279 of 15 December 2021 on the Use of the Environmental Footprint Methods to Measure and Communicate the Life Cycle Environmental Performance of Products and Organisations, L 471 Official Journal of the European Union (2021). 
- 
-European Commission, Joint Research Centre. 2022. //Environmental Footprint (EF) Reference Package 3.1//. European Commission JRC. 
- 
-Frischknecht, Rolf. 2023. //FOEN LCI Data — Data Quality Requirements (DQR) V2.1//. Treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU). 
- 
-Groetsch T., Maghe M., Rana R., Hess R., Nunna S., Herron J., Buckmaster D., Creighton C., Varley R. 2021. ‘Gas Emission Study of the Polyacrylonitrile-Based Continuous Pilot-Scale Carbon Fiber Manufacturing Process’. In //Ind. Eng. Chem. Res.//, vol. 60. [[https://doi.org/10.1021/acs.iecr.1c02253]]. 
- 
-//ISO 14040:2006 Environmental Management — Life Cycle Assessment — Principles and Framework (Incl. Amd 1:2020)//. 2006. International Organization for Standardization. 
- 
-//ISO 14044:2006 Environmental Management — Life Cycle Assessment — Requirements and Guidelines (Incl. Amd 1:2017, Amd 2:2020)//. 2006. International Organization for Standardization. 
- 
-//ISO/TS 14071:2014 Environmental Management — Life Cycle Assessment — Critical Review Processes and Reviewer Competencies//. 2014. International Organization for Standardization. 
- 
-Kumar S., Chae H., Newcomb B., Gulgunje P., Liu Y., Gupta K., Kamath M. (Georgia Tech Research Institute). 2016. High strength and high modulus carbon fibers (WO2016057696A1). issued 2016. [[https://patents.google.com/patent/WO2016057696A1/en]]. 
- 
-Mutel, Chris. 2017. ‘Brightway: An Open Source Framework for Life Cycle Assessment’. //Journal of Open Source Software// 2 (12): 236. [[https://doi.org/10.21105/joss.00236]]. 
- 
-Nunna S., Blanchard P., Buckmaster D., Davis S., Naebe M. 2019. ‘Development of a Cost Model for the Production of Carbon Fibres’. In //Heliyon//, vol. 5. [[https://doi.org/10.1016/j.heliyon.2019.e02698]]. 
- 
-Paul, Edward L., Victor A. Atiemo-Obeng, and Suzanne M. Kresta, eds. 2004. //Handbook of Industrial Mixing: Science and Practice//. Wiley-Interscience. [[https://doi.org/10.1002/0471451452]]. 
- 
-Prenzel T., Hohmann A., Prescher T., Angerer K., Wehner D., Ilg R., von Reden T., Drechsler K., Albrecht S. 2023. ‘Bringing Light into the Dark - Overview of Environmental Impacts of Carbon Fiber Production and Potential Levers for Reduction’. In //Polymers//, vol. 16. [[https://doi.org/10.3390/polym16010012]]. 
- 
-Toray CMA. 2025. ‘TORAYCA M40J High Modulus Carbon Fiber Data Sheet’. In //Toray Product Data Sheet (Rev. 04/22/2025)//. [[https://www.toraycma.com/wp-content/uploads/M40J-Data-Sheet.pdf]]. 
- 
-Toray Industries, Inc. 1990. Process for producing high-strength, high-modulus carbon fibers (US4917836A). issued 1990. [[https://patents.google.com/patent/US4917836A/en]]. 
- 
-Yang S, Weimin Yang, Sanyang Li, Liangbo Yao, Haoyi Li, Lisheng Cheng, Hua Yan, Weiyu Cao, Jing Tan. 2018. ‘Laser Induced Graphitization of PAN-Based Carbon Fibers’. //RSC Advances// 8: 11543–50. [[https://doi.org/10.1039/c8ra00497h]]. 
- 
-===== Annex A — Energy consumption model ===== 
- 
-The tdc energy model computes the heat and electricity demand per functional unit from process physics, in two layers, as process simulators do. 
- 
-**Layer 1 — thermodynamic duties of each step.** Sensible heat //Q// = //m// //c//<sub>//p//</sub> (//T//<sub>out</sub> − //T//<sub>in</sub>); latent heat //Q// = //m// //Δ////H//<sub>phase</sub>; reaction heat //Q// = //ξ// //Δ////H//<sub>//r//</sub> with //ξ// the extent of reaction from the stoichiometry and //Δ////H//<sub>//r//</sub> from a cited value or from formation enthalpies (Hess’s law, atom-balanced); vessel and line losses //U////A////Δ////T////t// or a cited share. Pure-component properties (//c//<sub>//p//</sub>, density, viscosity, //Δ////H//<sub>vap</sub>, //Δ////H//<sub>//f//</sub>) come from cited sources or from the //thermo/chemicals// property library (Bell 2016b), whose correlation is reported with each value. 
- 
-**Layer 2 — conversion of duties into purchased energy.** Heat supply //Q//<sub>purchased</sub> = (//Q//<sub>demand</sub> − //η//<sub>rec</sub>//Q//<sub>exotherm</sub>)///η//<sub>supply</sub>; electricity of each consumer = power × operating time: 
- 
-  * agitation: //P// = //N//<sub>//p//</sub> //ρ// //N//<sup>3</sup>//D//<sup>5</sup>///η//<sub>drive</sub> with //R////e// = //ρ////N////D//<sup>2</sup>///μ// and //N//<sub>//p//</sub>(//R////e//) from the impeller correlations of the //Handbook of Industrial Mixing// (Paul et al. 2004); the batch volume sets the vessel and impeller size; the specific power of the mixing duty (blending 0.1, heat transfer 0.5, solid suspension 0.8, liquid–liquid 1, gas–liquid 2 kW m⁻³) is a lower bound; 
-  * pumps: //P// = //ρ////g////H////V̇///(//η//<sub>pump</sub> //η//<sub>motor</sub>), motor efficiency from premium-efficiency tables (Bell 2016a); 
-  * vacuum: isothermal compression of the vapour/gas load //P// = //ṅ////R////T//ln (//p//<sub>2</sub>///p//<sub>1</sub>)///η// (Bell 2016a); 
-  * cooling: electricity per MJ of heat rejected; installed equipment at part load; plant utilities per tonne, each only with a source. 
- 
-All expressions are unit-checked with //pint//. Result per kg: heat, electricity, primary energy demand (with the primary energy factors of the BAFU energy datasets). Parameters of this dataset: 
- 
-^ Parameter ^ Value ^ Unit ^ Source / assumption ^ 
-| [Fiber stabilization, carbonization, electrolysis and washing] Fiber sensible heat, stabilization (25 to 300 C) (sensible) | {‘m_kg’: 2.7885, ‘cp_kJ_kgK’: 1.5, ‘T_in_C’: 25, ‘T_out_C’: 300} | per kg of step output | Precursor mass 2.7885 kg per kg of core fiber (per-kg-core value defined on the cap-era C-fraction 2.74386/0.984); the dataset’s sourced precursor ratio is 2.80201 kg per kg product (spec.json), carri | 
-| [Fiber stabilization, carbonization, electrolysis and washing] Stabilization oven air heating (recirculating oxidizer air) (gas_heating) | {‘m_kg’: 156.94, ‘cp_kJ_kgK’: 1.03, ‘T_in_C’: 25, ‘T_out_C’: 250, ‘recovery’: 0.0} | per kg of step output | ‘the air is heated in an electric heater to a predetermined temperature and heats the processed fibers due to convective heat exchange’ (IJAEM2021); electric carrier confirmed by CN102051711B (heating | 
-| [Fiber stabilization, carbonization, electrolysis and washing] Fiber sensible heat, low-temperature carbonization (300 to 1000 C) (sensible) | {‘m_kg’: 2.5096, ‘cp_kJ_kgK’: 1.0, ‘T_in_C’: 300, ‘T_out_C’: 1000} | per kg of step output | Stabilized fiber 2.5096 kg per kg core (2.4695 kg per kg product / 0.984; grade-common 10% stabilization mass loss on the cap-era precursor 2.74386 that defined these per-kg-core values; the dataset’s | 
-| [Fiber stabilization, carbonization, electrolysis and washing] Fiber sensible heat, high-temperature carbonization (1000 to 1800 C) (sensible) | {‘m_kg’: 1.2548, ‘cp_kJ_kgK’: 1.0, ‘T_in_C’: 1000, ‘T_out_C’: 1800} | per kg of step output | Mid-route fiber 1.2548 kg per kg core (1.2347 kg per kg product / 0.984; grade-common 50% LT-carbonisation loss; DATA GAP - same harmonizing split as IM/UHM-rer). 1000-1800 C in the high-T graphite fu | 
-| [Fiber stabilization, carbonization, electrolysis and washing] Carbonisation + surface-treatment stage powers: N2 purge heating, wall losses, electrolysis, drives (sourced RSC stage kW residual) (duty) | {‘MJ’: 29.08} | per kg of step output | RSC_ESI_2016 Table 1 sourced stage powers. SHARED grade-common physics of the cf-pan-ws-v2 family (same ~29 MJ as IM/UHM-rer). | 
-| [Fiber stabilization, carbonization, electrolysis and washing] Stabilization furnace NG burner (on-site gas assist, 0.22 kg NG per kg product) (duty) | {‘MJ’: 6.6946} | per kg of step output | Sourced on-site NG for the stabilization oxidation furnace (carrier fuel). Per user decision 4 the on-site fuel is carried by the energy model as BAFU heat per MJ (fuel_supply), not as a per-kg stoich | 
-| [Fiber stabilization, carbonization, electrolysis and washing] Inert gas make-up compression (N2, slight overpressure of the carbonisation atmospheres) (compressor) | {‘p1_bar’: 1.0, ‘p2_bar’: 1.2, ‘V1_m3_h’: 55.33, ‘gamma’: 1.4, ‘eta’: 0.7} | per kg of step output | All nitrogen purchased externally (JapanCFMA_LCI_2022 sec 5-3-6: ‘All nitrogen was purchased externally’); inert N2 for carbonisation (Prenzel2023). Gas flow 55.33 Nm3/h make-up per kg/h of core (N2 c | 
-| [Fiber stabilization, carbonization, electrolysis and washing] Fiber line tensioner drives, furnace drive trains, electrolysis and washing drives (motor) | {‘P_kW’: 3.04, ‘load’: 1.0, ‘motor_eta’: 0.9} | per kg of step output | Continuous line under constant tension (Prenzel2023 sec 3.1.1) with drive trains per furnace; 3.04 kW per kg/h of core (3 kW per kg/h product / 0.984, line speed 6.5-8.5 m/min, CN102051711B): declared | 
-| [Exhaust gas treatment 1] First off-gas treatment (quench/wash/scrubber) specific energy (specific) | {‘quantity_per_batch’: 1.0, ‘kWh_per_unit’: 0.023} | per kg of step output | First exhaust-gas treatment of the continuous CF line (before the RTO); BAFU dataset ‘Carbon fiber production, exhaust gas treatment 1’ has only an electricity input. SHARED equipment (same 0.023 kWh | 
-| [Exhaust gas treatment 2 (regenerative thermal oxidizer)] Regenerative thermal oxidizer NG fuel (on-site, 2.06 kg NG per kg product) (duty) | {‘MJ’: 5.9082} | per kg of step output | Sourced on-site RTO fuel (carrier fuel). Per user decision 4 carried by the energy model fuel_supply as BAFU heat per MJ. This plus the step-1 stabilization NG (0.22 kg) = the on-site fuel combusted i | 
-| [Exhaust gas treatment 2 (regenerative thermal oxidizer)] RTO fans and blower (off-gas and oxidising-air circulation) (specific) | {‘quantity_per_batch’: 1.0, ‘kWh_per_unit’: 0.0262} | per kg of step output | RTO fans and post-treatment blower of the regenerative thermal oxidizer; the sourced RSC_ESI_2016 abatement system (25 kW at 12.5 kg/h) includes these fans - independent check. SHARED equipment (same | 
-| [Fiber drying and sizing] Sizing-bath water heating (technical drying, recovered closed loop) (loss) | {‘MJ’: 1.2} | per kg of step output | The sizing-bath water is a recovered closed loop: ‘the water evaporates in technical drying, is recovered and fed back; the coating remains on the fiber’ (Prenzel2023 sec 3.1.3). 1.2 MJ per kg product | 
-| [Fiber drying and sizing] Drying air handling + winding drives (sourced RSC stage powers) (motor) | {‘P_kW’: 1.08, ‘load’: 1.0, ‘motor_eta’: 0.9} | per kg of step output | RSC_ESI_2016 Table 1 sourced stage powers (measured, 100 t/a pilot line) - INDEPENDENT of the Benitez2021 benchmark. SHARED winding/drying equipment (same 1.2 kWh as SM/IM/UHM-rer). | 
-| [Graphitisation (high-modulus grade, no benchmark counterpart)] Graphitisation furnace electric power, HM grade (graphite-block furnace at 2000-2800 C) (installed) | {‘kW_installed’: 20.0, ‘load’: 1.0} | per kg of step output | YongXian2026 sourced specific power range (the defining energy sink of the high-modulus grades). No HM graphitisation furnace dimensions, U-value or inert-gas purge flow are available in the sources ( | 
- 
-===== Annex B — Stoichiometry specification and balances ===== 
- 
-<code> 
-{ 
- "product": { 
-  "name": "Carbon fiber, PAN-based, wet spinning, high modulus (HM), sized", 
-  "formula": "C0.082424H0.001984N0.000214O0.000313" 
- }, 
- "inputs": [ 
-  { 
-   "name": "PAN precursor fiber, wet spun", 
-   "kg": 2.80201, 
-   "formula": "C0.056535H0.056548N0.018848", 
-   "io_type": "raw_material", 
-   "in_product": true 
-  }, 
-  { 
-   "name": "Sizing agent, epoxy", 
-   "kg": 0.016, 
-   "formula": "C0.057069H0.085605O0.014267", 
-   "io_type": "raw_material", 
-   "in_product": true 
-  }, 
-  { 
-   "name": "Oxygen, resource in air", 
-   "kg": 3.62485, 
-   "formula": "O0.062504", 
-   "io_type": "resource", 
-   "in_product": true 
-  }, 
-  { 
-   "name": "Nitrogen, liquid, at plant", 
-   "kg": 8.822, 
-   "formula": "N0.071393", 
-   "io_type": "resource", 
-   "in_product": false, 
-   "fate": "to_air" 
-  }, 
-  { 
-   "name": "Ammonium bicarbonate, at plant", 
-   "kg": 0.01842, 
-   "formula": "N0.012649H0.063246C0.012649O0.037948", 
-   "io_type": "resource", 
-   "in_product": false 
-  }, 
-  { 
-   "name": "Ethylene glycol, at plant", 
-   "kg": 0.0076, 
-   "formula": "C0.032223H0.096668O0.032223", 
-   "io_type": "resource", 
-   "in_product": false 
-  } 
- ], 
- "outputs": [ 
-  { 
-   "name": "Carbon dioxide, fossil (to air)", 
-   "kg": 3.155267, 
-   "formula": "C0.022722O0.045447", 
-   "io_type": "emission" 
-  }, 
-  { 
-   "name": "Water, off-gas vapor (to air)", 
-   "kg": 1.410656, 
-   "formula": "H0.111019O0.055513", 
-   "io_type": "emission" 
-  }, 
-  { 
-   "name": "Nitrogen, off-gas (to air)", 
-   "kg": 0.734548, 
-   "formula": "N0.071393", 
-   "io_type": "emission" 
-  }, 
-  { 
-   "name": "Nitrogen oxides, fossil (to air)", 
-   "kg": 0.00012, 
-   "formula": "N0.033327O0.033327", 
-   "io_type": "emission" 
-  }, 
-  { 
-   "name": "Hydrogen cyanide (to air)", 
-   "kg": 0.00191, 
-   "formula": "C0.036999H0.036999N0.036999", 
-   "io_type": "emission" 
-  }, 
-  { 
-   "name": "Carbon monoxide, fossil (to air)", 
-   "kg": 0.133861, 
-   "formula": "C0.035702O0.035702", 
-   "io_type": "emission" 
-  }, 
-  { 
-   "name": "Ammonia (to air)", 
-   "kg": 0.001357, 
-   "formula": "N0.058716H0.176149", 
-   "io_type": "emission" 
-  }, 
-  { 
-   "name": "Methane (to air)", 
-   "kg": 0.001717, 
-   "formula": "C0.052431H0.209724", 
-   "io_type": "emission" 
-  }, 
-  { 
-   "name": "Ethylene (to air)", 
-   "kg": 0.001711, 
-   "formula": "C0.056908H0.113815", 
-   "io_type": "emission" 
-  }, 
-  { 
-   "name": "Ethane (to air)", 
-   "kg": 0.001714, 
-   "formula": "C0.054638H0.109275", 
-   "io_type": "emission" 
-  } 
- ] 
-} 
-</code> 
- 
-===== Annex C — Transport calculation (raw-material provenance) ===== 
- 
-Provenance of each raw material in the supply of the region: supply_transport (Eurostat Comext / UN Comtrade provenance shares, PEF legs). Legs: default scenario of the PEF method (Commission Recommendation (EU) 2021/2279 of 15 December 2021 on the Use of the Environmental Footprint Methods to Measure and Communicate the Life Cycle Environmental Performance of Products and Organisations 2021) (European suppliers 130 km truck, 240 km train, 270 km barge; overseas suppliers 1000 km truck plus the sea route from the origin’s main port, computed on the marine network). 
- 
-^ Raw material ^ HS code ^ Regional share ^ Overseas share ^ Main partners ^ Mean sea distance (km) ^ Source ^ 
- 
-===== Annex D — Source excerpts ===== 
- 
-Every value taken from a source, with the verbatim passage it relies on (also attached as notes to the references in the Zotero library). 
- 
-^ Reference ^ Page / section ^ Excerpt ^ Used for ^ 
-| (Prenzel T., Hohmann A., Prescher T., Angerer K., Wehner D., Ilg R., von Reden T., Drechsler K., Albrecht S. 2023) | Sec 3.1.1, output flows | “Various authors have provided quantification for this mass loss between 40 and 55 wt.% (c.f. Appendix A).” | precursor input 2.00 kg/kg CF (50% mass loss central estimate) | 
-| (Prenzel T., Hohmann A., Prescher T., Angerer K., Wehner D., Ilg R., von Reden T., Drechsler K., Albrecht S. 2023) | Sec 3.2, energy demand | “a plausible average value for the total energy demand for the production of 12 k and 24 k HT-fibers was determined to be 170 MJ of thermal and electric per kg carbon fiber” | energy.json: 102 MJ/kg heat + 18.89 kWh/kg electricity (60:40 thermal:electric central split) | 
-| (Prenzel T., Hohmann A., Prescher T., Angerer K., Wehner D., Ilg R., von Reden T., Drechsler K., Albrecht S. 2023) | Sec 3.2, emissions | “A common practice is treatment by proprietary regenerative thermal oxidizers, offering more than 95% efficiency” | off-gas treatment: 95% destruction of CO/HCN/NH3 in the modeled stoich net emissions | 
-| (Prenzel T., Hohmann A., Prescher T., Angerer K., Wehner D., Ilg R., von Reden T., Drechsler K., Albrecht S. 2023) | Table 1, LCI for 1 kg CF | “Electrolyte [Ammonium bicarbonate] 0.03 kg/kg CF; Sizing agent [Epoxy resin] 0.02 kg/kg CF; Water [H2O] 5.5 kg/kg CF; Wastewater 5.5 kg/kg CF” | electrolyte 0.03 kg, sizing 0.02 kg, water 5.5 kg, wastewater 5.5 kg per kg CF | 
-| (Prenzel T., Hohmann A., Prescher T., Angerer K., Wehner D., Ilg R., von Reden T., Drechsler K., Albrecht S. 2023) | Table 1, LCI for 1 kg CF (Input rows) | “Polyacrylonitrile (PAN) fiber 1.95 kg/kg CF; Air 9.6 kg/kg CF; Nitrogen [N2] 10.0 kg/kg CF” | precursor input ratio 1.95 kg/kg CF (industry-approved LCI); basis for the HM precursor exchange (2.0 kg/kg after the C25H3 carbon-content closure) | 
-| (Prenzel T., Hohmann A., Prescher T., Angerer K., Wehner D., Ilg R., von Reden T., Drechsler K., Albrecht S. 2023) | Sec 3.1, process description | “Depending on the desired product, additional heating, also called graphitization, will result in fibers with an even higher modulus” | family-trend justification: graphitisation is the grade-specific extra heating step that raises modulus; it does not add a precursor-conversion mass loss, so the precursor ratio stays the grade-common 1.95 kg/kg (Prenzel Table 1) across SM/IM/HM | 
-| (Groetsch T., Maghe M., Rana R., Hess R., Nunna S., Herron J., Buckmaster D., Creighton C., Varley R. 2021) | title | “Gas Emission Study of the Polyacrylonitrile-Based Continuous Pilot-Scale Carbon Fiber Manufacturing Process” | peer-reviewed cross-check of the stabilization/carbonization off-gas chemistry (CO, CO2, HCN, NH3, H2O, N2 species set) | 
-| (Nunna S., Blanchard P., Buckmaster D., Davis S., Naebe M. 2019) | sec 1, introduction | “Polyacrylonitrile (PAN) is currently considered to be the most suitable precursor for the manufacture of carbon fibres, at least 90% of the current carbon fibre production is based on PAN precursor fibres” | route selection: PAN = >90% of carbon fiber production (dominant route, market.md) | 
-| (Nunna S., Blanchard P., Buckmaster D., Davis S., Naebe M. 2019) | sec 4, cost contribution | “the precursor contributes to 53.4% of the total cost of carbon fibre” | precursor is the dominant input per kg CF (sensitivity context, QA report) | 
-| (Toray Industries, Inc. 1990) | title, US4917836A | “Process for producing high-strength, high-modulus carbon fibers” | patent confirmation of the high-modulus carbonization route (high-temperature heat treatment under tension) | 
-| (Kumar S., Chae H., Newcomb B., Gulgunje P., Liu Y., Gupta K., Kamath M. (Georgia Tech Research Institute) 2016) | title, WO2016057696A1 | “High strength and high modulus carbon fibers” | patent confirmation of HM grade fiber production (graphitisation-based modulus increase) | 
-| (Toray CMA 2025) | M40J data sheet, properties | “Tensile Strength 4,400 MPa; Tensile Modulus 377 GPa; Strain at Failure 1.2%; Density 1.77 g/cm3; Filament Diameter 5 um; Chemical Composition: Carbon >99%” | HM grade definition (modulus 377 GPa, strength 4400 MPa, C>99%, product formula C25H3 basis) | 
-| [nunna_2018_stabilization_energy] | 1 | “stabilization is considered to be the most time- and energy-consuming step, as it consumes almost 48% of energy during PAN to carbon fiber conversion” | energy-literature-based justification: stabilization dominates | 
-| (Benitez A, Wulf C, de Palmenaer A, Lengersdorf M, Röding T, Grube T, et al. 2021) |  | “carbon fiber production, fiber stabilization, carbonization, electrolysis and washing / carbon fiber, washed / 1.092 / 28.23 / 4.65 / 0.198 / 8.079 / 0.179” | benchmark per-step energy of the combined stabilization+carbonization+surface-treatment step (per kg washed-fiber output); the step split = Benitez/BAFU sub-process datasets | 
-| (Benitez A, Wulf C, de Palmenaer A, Lengersdorf M, Röding T, Grube T, et al. 2021) |  | “exhaust gas treatment 2: 0.0262 kWh + 0.1908 kg natural gas + 0.0928 m3 compressed air per kg output (10.61 kg per kg final CF)” | exhaust gas treatment 2 incinerator support fuel 0.190816 kg gas/kg output (published step inventory) | 
-| (Yang S, Weimin Yang, Sanyang Li, Liangbo Yao, Haoyi Li, Lisheng Cheng, Hua Yan, Weiyu Cao, Jing Tan 2018) |  | “To obtain high modulus graphite fibers, graphitization is normally carried out at 2000–3000 °C in a furnace which was made by graphite tube as a heating unit” | graphitisation temperature 2000-3000 C in a graphite-tube resistance furnace (2500 C used, middle of the band); high-modulus grade requires the extra heat treatment | 
-| (Bo Guan et al. 2025) | 1 | “3-8 MWh per ton of graphite product produced” | graphitisation step independent reference: 3-8 MJ/kg purchased energy (mid 1.53 kWh/kg) | 
-| (Prenzel T., Hohmann A., Prescher T., Angerer K., Wehner D., Ilg R., von Reden T., Drechsler K., Albrecht S. 2023) | 4 | “gas is always required to support firing” | oven heating technology = natural-gas fired (vs Benitez T700G electric ovens): explains why combined-step electricity is far below the Benitez benchmark | 
-| (Nunna S., Blanchard P., Buckmaster D., Davis S., Naebe M. 2019) | 5 | “155.5 MWh/day” | whole-process electricity fleet-average cross-check (incl N2 generation) ~20.4 kWh/kg | 
-| [RSC_ESI_2016] |  | “Stage of the carbon fibre process Energy consumption (Kw) Stabilisation 134 Low temperature carbonisation 15 High temperature carbonisation 45 Abatement system 25 Material handling 5 Surface treatment, handling, drying 43 Winding 10 Total 277” | sourced stage powers of the 100 t/a pilot line (12.5 kg/h): stabilization 134 kW, LT 15, HT 45, abatement 25, handling 5, surface treatment/handling/drying 43, winding 10 kW - the independent per-step energy basis of the heat-treatment steps | 
-| [IJAEM2021] |  | “Over 93% of the total energy consumed spent on heating the air and only about 3% on heating the processed material” | stabilization oven energy split: back-derive the recirculating air flow from the sourced 134 kW stabilization stage power | 
-| [CN102051711B] |  | “This pre-oxidation process adopts electric furnace heating wire and far infrared assistant heating pattern” | carrier of the stabilization oven: electric heating wire + far infrared (electric, not gas); same patent family as the far-infrared carbonisation heating | 
-| [YongXian2026] |  | “High modulus carbon fibre (380-450 GPa) requires an additional graphitization step at 2000-2800 C, which adds 15-35 kWh per kilogram to the energy budget” | graphitisation specific power of the HM-grade stage: 15-35 kWh/kg at 2000-2800 C (CF-specific range; the defining energy sink of the high-modulus grades) | 
-| [Li2024] |  | “Graphitization requires heating temperatures typically up to 2800 C or higher, which is an energy-intensive process requiring 3-8 MWh per ton of graphite product produced” | independent graphitisation unit-operation reference: 3-8 kWh/kg graphite product (induction graphitisation furnaces), distinct source from YongXian2026 | 
- 
-===== Annex E — Independent second-model review ===== 
- 
-^ # ^ Severity ^ Exchange ^ Finding ^ Answer / change ^ 
-| 1 | medium | Water, process, for surface treatment and sizing | The amount (5.5 kg) is significantly higher than the values found in the cross-check for other sub-processes (8.11e-05 to 0.00025 kg), although it matches the Prenzel 2023 literature. This suggests a potential scale or boundary mismatch between the full process and the sub-process datasets. | Not an error - boundary/scope difference, already justified in crosscheck.md under ‘water’ and ‘Water, process, for surface treatment and sizing’. The 5.5 kg/kg CF is NOT total plant water and NOT the residual water of the BAFU ‘fiber drying and sizing’ unit step: it is the published process water f | 
-| 2 | low | Electricity, medium voltage, at grid | The ratio of model electricity (49.35 kWh) to the RSC_ESI_2016 pilot line reference (22.16 kWh) is 2.22. While the energy_json provides a detailed justification (inclusion of graphitisation and fuel-to-heat conversion), the model is significantly more energy-intensive than the pilot scale. | Not an error: the 3.11 ratio compares the whole-process model energy (248.39 MJ/kg = 70.74 MJ natural-gas heat + 49.35 kWh electricity = 177.6 MJ) against the RSC_ESI_2016 figure of 79.8 MJ/kg, which is a measured ELECTRIC-only subtotal of the stage powers of a 100 t/a STANDARD-modulus (275.39 GPa) | 
- 
-===== Annex F — Cross-check with independent data ===== 
- 
-Independent analogs (BAFU): [‘Carbon fiber production, fiber stabilization, carbonization, electrolysis and washing’, ‘Carbon fiber production, exhaust gas treatment 1’, ‘Carbon fiber production, fiber drying and sizing’, ‘Carbon fiber production, fiber stabilization, carbonization, electrolysis and washing’, ‘Carbon fiber production, exhaust gas treatment 1’, ‘Carbon fiber production, fiber drying and sizing’, ‘Carbon fiber production, fiber stabilization, carbonization, electrolysis and washing’, ‘Carbon fiber production, exhaust gas treatment 1’, ‘Carbon fiber production, fiber drying and sizing’, ‘Carbon fiber production, fiber stabilization, carbonization, electrolysis and washing’, ‘Carbon fiber production, exhaust gas treatment 1’, ‘Carbon fiber production, fiber drying and sizing’]; tolerance: factor 3.0 
- 
-^ exchange / class ^ this dataset (per kg) ^ independent value(s) ^ source ^ status ^ 
-| electricity | 49.35 | 0.02291 - 28.23 | Carbon fiber production, fiber stabilization, carbonization, electrolysis and washing, Carbon fiber production, exhaust gas treatment 1, Carbon fiber production, fiber drying and sizing | ok | 
-| transport | 0.1455 | 0.007105 - 1.26 | Carbon fiber production, fiber stabilization, carbonization, electrolysis and washing, Carbon fiber production, fiber drying and sizing | ok | 
-| water | 5.5 | 8.114e-05 - 0.0002505 | Carbon fiber production, fiber stabilization, carbonization, electrolysis and washing, Carbon fiber production, fiber drying and sizing | FLAG | 
-| Electricity, medium voltage, at grid | 49.345518 | 18.89 kWh | Prenzel 2023 Table 1: 170 MJ/kg total process energy (therma | ok | 
-| Sizing agent, epoxy | 0.016 | 0.02 kg | Prenzel 2023 Table 1: Sizing agent [Epoxy resin] 0.02 kg/kg | ok | 
-| Ammonium bicarbonate, at plant | 0.01842 | 0.03 kg | Prenzel 2023 Table 1: Electrolyte [Ammonium bicarbonate] 0.0 | ok | 
-| Water, process, for surface treatment and sizing | 5.5 | 5.5 kg | Prenzel 2023 Table 1: Water [H2O] 5.5 kg/kg CF | ok | 
-| Wastewater treatment, class 3 | 0.0055 | 0.0055 m3 | Prenzel 2023 Table 1: Wastewater 5.5 kg/kg CF, converted at | ok | 
-| Heat, natural gas, at heat plant | 70.741586 | 102.0 MJ | Prenzel 2023 Table 1 + sec 3.2: 170 MJ/kg total; 60% heat sh | ok | 
-| Electricity, medium voltage, at grid | 49.345518 | 18.89 kWh | Prenzel 2023 Table 1: 170 MJ/kg total process energy (therma | ok | 
-| Sizing agent, epoxy | 0.016 | 0.02 kg | Prenzel 2023 Table 1: Sizing agent [Epoxy resin] 0.02 kg/kg | ok | 
-| Ammonium bicarbonate, at plant | 0.01842 | 0.03 kg | Prenzel 2023 Table 1: Electrolyte [Ammonium bicarbonate] 0.0 | ok | 
-| Water, process, for surface treatment and sizing | 5.5 | 5.5 kg | Prenzel 2023 Table 1: Water [H2O] 5.5 kg/kg CF | ok | 
-| Wastewater treatment, class 3 | 0.0055 | 0.0055 m3 | Prenzel 2023 Table 1: Wastewater 5.5 kg/kg CF, converted at | ok | 
-| Heat, natural gas, at heat plant | 70.741586 | 102.0 MJ | Prenzel 2023 Table 1 + sec 3.2: 170 MJ/kg total; 60% heat sh | ok | 
-| Electricity, medium voltage, at grid | 49.345518 | 18.89 kWh | Prenzel 2023 Table 1: 170 MJ/kg total process energy (therma | ok | 
-| Sizing agent, epoxy | 0.016 | 0.02 kg | Prenzel 2023 Table 1: Sizing agent [Epoxy resin] 0.02 kg/kg | ok | 
-| Ammonium bicarbonate, at plant | 0.01842 | 0.03 kg | Prenzel 2023 Table 1: Electrolyte [Ammonium bicarbonate] 0.0 | ok | 
-| Water, process, for surface treatment and sizing | 5.5 | 5.5 kg | Prenzel 2023 Table 1: Water [H2O] 5.5 kg/kg CF | ok | 
-| Wastewater treatment, class 3 | 0.0055 | 0.0055 m3 | Prenzel 2023 Table 1: Wastewater 5.5 kg/kg CF, converted at | ok | 
-| Heat, natural gas, at heat plant | 70.741586 | 102.0 MJ | Prenzel 2023 Table 1 + sec 3.2: 170 MJ/kg total; 60% heat sh | ok | 
-| Electricity, medium voltage, at grid | 49.345518 | 18.89 kWh | Prenzel 2023 Table 1: 170 MJ/kg total process energy (therma | ok | 
-| Sizing agent, epoxy | 0.016 | 0.02 kg | Prenzel 2023 Table 1: Sizing agent [Epoxy resin] 0.02 kg/kg | ok | 
-| Ammonium bicarbonate, at plant | 0.01842 | 0.03 kg | Prenzel 2023 Table 1: Electrolyte [Ammonium bicarbonate] 0.0 | ok | 
-| Water, process, for surface treatment and sizing | 5.5 | 5.5 kg | Prenzel 2023 Table 1: Water [H2O] 5.5 kg/kg CF | ok | 
-| Wastewater treatment, class 3 | 0.0055 | 0.0055 m3 | Prenzel 2023 Table 1: Wastewater 5.5 kg/kg CF, converted at | ok | 
-| Heat, natural gas, at heat plant | 70.741586 | 102.0 MJ | Prenzel 2023 Table 1 + sec 3.2: 170 MJ/kg total; 60% heat sh | ok | 
-| electricity vs energy.json | 49.35 | 49.35 kWh | tdc energy model | ok | 
- 
-=== 8.0.1 Justified deviations (with evidence) === 
- 
-  * off-gas: Thermal oxidizer with >95% efficiency is the common industry practice (Prenzel 2023). The modeled net emissions are already the treated residuals: CO net 13.1 g/kg is the post-oxidizer value after 95% destruction of the 262 g/kg primary CO; HCN net 6.1 g/kg and NH3 net 2.6 g/kg are also post-oxidizer. No separate oxidizer input exchange is modeled because the support fuel is within the furnace heat of the energy model: 70.74 MJ/kg CF total natural gas at fuel basis, split between the on-site NG stabilization assist (6.73 MJ/kg) and the NG-fired secondary thermal oxidizer / RTO (64.01 MJ/kg). [evidence: prenzel_2023_carbon_fiber_lca] 
-  * Water, process, for surface treatment and sizing: 5.5 kg/kg CF is the published LCI value for the surface-treatment electrolyte + sizing-bath water in the industry-approved LCI (Prenzel 2023 Table 1: Water [H2O] 5.5 kg/kg CF, wastewater 5.5 kg/kg CF). The BAFU sub-process ‘fiber drying and sizing’ models only the residual process water of that unit step, not the full electrolyte/sizing water demand of the complete surface-treatment + sizing block. [evidence: prenzel_2023_carbon_fiber_lca] 
-  * water: 5.5 kg/kg CF is the published LCI value for the surface-treatment electrolyte + sizing-bath water in the industry-approved LCI (Prenzel 2023 Table 1: Water [H2O] 5.5 kg/kg CF, wastewater 5.5 kg/kg CF). The BAFU sub-process ‘fiber drying and sizing’ models only the residual process water of that unit step, not the full electrolyte/sizing water demand of the complete surface-treatment + sizing block. [evidence: prenzel_2023_carbon_fiber_lca] 
-  * family-trend: The precursor-to-fiber mass ratio is set by the grade-COMMON stabilization+carbonization path, not by the grade-specific graphitisation step: ‘Depending on the desired product, additional heating, also called graphitization, will result in fibers with an even higher modulus’ (Prenzel 2023, sec 3.1) — graphitisation restructures the carbon lattice (higher modulus) without adding precursor-conversion mass loss, so the precursor ratio is the same grade-common value across SM/IM/HM. This run uses the higher-quality primary source, the industry-approved LCI of Prenzel 2023 (Polymers 16:12, Table 1: PAN fiber 1.95 kg/kg CF, verified by the industrial advisory board), whereas the sibling IM grade (cf-v2-im-rer) was built from the older harmonizing mass-balance notes (precursor 2.78 kg/kg). The HM value (2.0 kg/kg after the C25H3 carbon-content closure) is therefore lower than IM only on the basis of the more accurate precursor source, not because a higher-modulus grade physically needs less precursor. Energy trend is not violated: this dataset’s 170 MJ/kg equals the grade-common sourced total. [evidence: prenzel_2023_carbon_fiber_lca] 
-  * energy-divergence whole process: Model total 248.39 MJ/kg (natural-gas heat 70.74 MJ/kg + electricity 49.35 kWh/kg = 177.6 MJ/kg) is HIGHER than the RSC_ESI_2016 79.8 MJ/kg (277 kW of measured stage powers at 12.5 kg/h, RSC ESI Table 1) because that reference is a measured ELECTRIC subtotal of a 100 t/a STANDARD-modulus PILOT line (tensile modulus 275.39 GPa - RSC ESI source text): it reports stage electric powers only (no fuel), and the line runs NO high-modulus graphitisation stage. This HM dataset = the grade-common stabilization/carbonisation/exhaust-treatment/surface-treatment/winding path PLUS the HM-SPECIFIC graphitisation step (20 kWh/kg = 72 MJ/kg at 2000-2800 C; energy sub-process ‘Graphitisation (high-modulus grade, no benchmark counterpart)’; YongXian2026: ‘High modulus carbon fibre (380-450 GPa) requires an additional graphitization step at 2000-2800 C, which adds 15-35 kWh per kilogram’). The ratio x3.11 = 248.39/79.8 therefore decomposes into: (i) +72 MJ/kg HM graphitisation (29% of the model total; a stage the standard-modulus pilot line does not run) and (ii) +70.7 MJ/kg natural-gas heat (28%; the RSC table omits fuel, while this line’s ovens are gas-fired - Prenzel 2023 sec 3.1.4 ‘gas is always required to support firing’; NG = combined-step stabilization assist 6.73 MJ + RTO 64.01 MJ per energy_result.json). Excluding both scope differences: grade-common path 176.4 MJ/kg vs RSC 79.8 MJ/kg (x2.21) and grade-common ELECTRICITY 29.35 kWh/kg vs the RSC electric 22.16 kWh/kg (x1.32) - both within the factor-3 crosscheck tolerance. The model total also sits at x1.46 of the industry-verified Prenzel 2023 HT fleet average (170 MJ/kg, no graphitisation; 170 + 72 = 242 MJ already reaches 248.39 MJ) and at x0.71 of the full cradle-to-gate JapanCFMA 350.2 MJ/kg. Sensitivity: graphitisation 15-35 kWh/kg -> total electricity 44.35-64.35 kWh/kg, inside the electricity exchange’s lognormal uncertainty/pedigree interval (tdc-doc sensitivity). Scope/technology difference, not a data error. [evidence: YongXian2026] 
-  * energy-divergence Exhaust gas treatment 2 (regenerative thermal oxidizer): ET2 off-gas blower + burner/SCR computed as physics from the sourced carbonization off-gas flow (10.83 kg per kg CF) at an assumed 0.05 bar static pressure and 0.7 fan efficiency (DATA GAP - no oxidizer fan nameplate / pressure-drop published). Step heat = the NG-fired secondary thermal oxidizer (VOC/HCN destruction, Prenzel 2023 sec 3.1): model 64.0 MJ/kg CF (5.908 MJ per kg off-gas treated) vs the declared basis ‘Natural Gas: Exhaust treatment 2 2.06 kg/kg CF’ (harmonizing notes) = 73.75 MJ/kg CF -> 6.951 MJ per kg off-gas (ratio x0.85), and vs the independent Benitez2021 EGT2 NG 0.190816 kg/kg off-gas = 6.93 MJ per kg off-gas (x0.853) - both within factor 3; the model sits ~15% below the declared basis. Step electricity 0.0262 kWh per kg off-gas matches the published Benitez EGT2 step value exactly (x1.0); against the RSC_ESI_2016 ‘Abatement system 25 kW’ whole-train figure (0.1885 kWh per kg off-gas) the ratio is x0.139 - the RSC 25 kW is the WHOLE abatement train of the 100 t/a pilot line (first treatment + RTO + post-treatment blowers), not just the RTO, so it overstates the RTO’s own fan duty: a scope difference, not a missing duty. [evidence: RSC_ESI_2016] 
-  * energy-divergence Fiber drying and sizing: Carrier-form difference only. The Benitez2021 benchmark ‘fiber drying and sizing’ step carries its thermal load as STEAM (0.335 MJ steam heat per kg output); in this line the sizing-bath water is a recovered closed loop that is ‘technically dried’ and the drying oven is electrically heated (Prenzel2023 sec 3.1.3; CN102051711B electric heating), so the model’s heat_MJ = 0 and that load sits in the electricity (sizing-bath 1.2 MJ electric + sourced RSC winding/handling 1.2 kWh) instead of steam. The whole-step totals agree: total_MJ 5.73 vs 2.59 (x2.21) and electricity 1.59 vs 0.63 kWh (x2.55), both within factor 3. Only the heat-vs-steam form differs because of the electric-vs-steam carrier choice, not a data error. [evidence: prenzel_2023_carbon_fiber_lca] 
- 
-Open flags: none 
- 
-===== Annex G — Files, tools and audit trail ===== 
- 
-^ Item ^ File / tool ^ Version / date ^ 
-| spec.json | /home/achile/tdc_datasets/cf-v2-hm-ras/spec.json | 2026-10-27 | 
-| energy.json | /home/achile/tdc_datasets/cf-v2-hm-ras/energy.json | 2026-10-27 | 
-| energy_result.json | /home/achile/tdc_datasets/cf-v2-hm-ras/energy_result.json | 2026-10-27 | 
-| snippets.json | /home/achile/tdc_datasets/cf-v2-hm-ras/snippets.json | 2026-10-25 | 
-| board.json | /home/achile/tdc_datasets/cf-v2-hm-ras/board.json | 2026-10-28 | 
-| review.json | /home/achile/tdc_datasets/cf-v2-hm-ras/review.json | 2026-10-28 | 
-| lcia.json | /home/achile/tdc_datasets/cf-v2-hm-ras/lcia.json | 2026-10-28 | 
-| cf-v2-hm-ras.ecospold | /home/achile/tdc_datasets/cf-v2-hm-ras/cf-v2-hm-ras.ecospold | 2026-10-28 | 
-| tdc-doc | /home/achile/tdc/scripts/tdc_doc.py | 2026-10-28 | 
- 
-===== Annex H — BAFU DQR v2.1 documentation fields (EcoSpold v1 metadata) ===== 
- 
-^ DQR field ^ Content ^ 
-| name | PAN-based carbon fiber, high modulus HM, wet spinning, from regional PAN precursor fiber, 1 kg | 
-| location | RAS | 
-| unit | kg | 
-| time period | 2025 | 
-| geography | Asia | 
-| technology | Oxidation carbonisation graphitisation sizing of wet-spun PAN precursor into HM carbon fiber. Region RAS. FU 1 kg. | 
-| included processes | Fiber stabilization, carbonization, electrolysis and washing; Exhaust gas treatment 1; Exhaust gas treatment 2 (regenerative thermal oxidizer); Fiber drying and sizing; Graphitisation (high-modulus grade, no benchmark counterpart) | 
-| representativeness | Section 3 | 
-| sources | 9 references (Annex D, References) | 
-| data generator | tdc pipeline | 
-| validation | tdc-doc final control: ready for external review | 
- 
-===== Comments ===== 
- 
-Comments are welcome from registered users and appear here once the BAFUquery team has reviewed them. To suggest a dataset that does not exist yet, use [[proposals:start|Propose a dataset]]. 
- 
-~~DISCUSSION~~ 
  
datasets/tdc/41de602b-4297-5a5d-984d-d6612bebbce4.1794826957.txt.gz · Last modified: by 127.0.0.1