OpenData Wiki

Dataset documentation and review before publication

User Tools

Site Tools


datasets:tdc:c724fe59-4f68-5735-a13e-4edb0d44388d

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
datasets:tdc:c724fe59-4f68-5735-a13e-4edb0d44388d [2026/11/16 22:59] – external edit 127.0.0.1datasets:tdc:c724fe59-4f68-5735-a13e-4edb0d44388d [2026/11/20 01:27] (current) – removed - external edit (Unknown date) 127.0.0.1
Line 1: Line 1:
-====== Life Cycle Inventory of Carbon fiber, PAN-based, wet spinning, intermediate modulus (IM), sized — Asia (RAS) ====== 
- 
-//Unit-process dataset, cradle-to-gate, 1 kg of sized, intermediate modulus (IM) carbon fiber, PAN-based, wet spun — documentation for external critical review// 
- 
-^ Item ^ Value ^ 
-| Dataset name (BAFU naming rules, DQR §4.7.1) | Carbon fiber, PAN-based, wet spinning, IM, RAS | 
-| Dataset UUID / version | carbon-fiber-pan-based-wet-spinning-im-ras-090169 / draft (tdc) | 
-| Reference product, unit | Carbon fiber, PAN-based, wet spinning, intermediate modulus (IM), sized, kg | 
-| Location (DQR location code) | RAS — Asia | 
-| Reference year / time period | 2020-2025, reference year 2024 / 2020-2025, reference year 2024 | 
-| Technology level | current average technology (as described in the sources, Section 3) | 
-| Background database | BAFU 2026 v1 (Memgraph graph ''%%bafuquery-db%%''); no other background database | 
-| LCIA method | EF v3.1 (European Commission, Joint Research Centre 2022) (Brightway 2 / bw2calc (Mutel 2017)) | 
-| Status | ready for external review | 
-| Prepared by | tdc pipeline (datasetcreator agent), documentation and final check by tdc-doc | 
- 
-===== 1 Introduction ===== 
- 
-Conversion of 1 kg of wet-spun PAN precursor fiber into 1 kg of sized, intermediate modulus (IM) carbon fiber: stabilization (oxidation in air), low- and high-temperature carbonisation, surface treatment, sizing and drying, with exhaust-gas treatment and plant utilities. The PAN precursor fiber itself (acrylonitrile polymerisation, wet spinning, coagulation, washing, stretching, drying, solvent recovery) is a separate tdc dataset cf-v2-precursor-RER. 
- 
-This report documents the dataset according to ISO 14040 (//ISO 14040:2006 Environmental Management — Life Cycle Assessment — Principles and Framework (Incl. Amd 1:2020)// 2006) and ISO 14044 (//ISO 14044:2006 Environmental Management — Life Cycle Assessment — Requirements and Guidelines (Incl. Amd 1:2017, Amd 2:2020)// 2006) and to the BAFU LCI Data Quality Requirements v2.1 (Frischknecht 2023). It is written for the external critical reviewer (ISO 14044 clause 6, ISO/TS 14071 (//ISO/TS 14071:2014 Environmental Management — Life Cycle Assessment — Critical Review Processes and Reviewer Competencies// 2014)): all calculation steps are reproducible from the files listed in Annex G, all input values are traceable to a source (reference list and verbatim excerpts in Annex D) or to a stated assumption (Section 4.6). 
- 
-===== 2 Goal and scope definition (ISO 14044, 4.2) ===== 
- 
-==== 2.1 Goal of the study ==== 
- 
-  * Intended application: background dataset for LCA studies (BAFU 2026 database extension) 
-  * Reasons for carrying out the study: missing dataset in the background database 
-  * Intended audience: LCA practitioners, external critical reviewer 
-  * Comparative assertions intended to be disclosed to the public: no 
- 
-==== 2.2 Functional unit and reference flow ==== 
- 
-The functional unit is 1 kg of sized, intermediate modulus (IM) carbon fiber, PAN-based, wet spun of product at the plant gate. Reference flow: **1 kg of sized, intermediate modulus (IM) carbon fiber, PAN-based, wet spun** of Carbon fiber, PAN-based, wet spinning, intermediate modulus (IM), sized at the plant gate. Product definition: Carbon fiber, PAN-based, wet spinning, intermediate modulus (IM), sized [see product exchange]. 
- 
-==== 2.3 Product system and system boundary ==== 
- 
-Cradle-to-gate: raw-material and energy supply (BAFU datasets), transport to the plant, the process steps of Section 3, emissions and waste treatment. 
- 
-{{ :datasets:tdc:c724fe59-4f68-5735-a13e-4edb0d44388d:chain.png?900|Product system and system boundary (unit processes, flows crossing the boundary). }} 
- 
-//Product system and system boundary (unit processes, flows crossing the boundary).// 
- 
-^ Life cycle stage ^ Included ^ Notes / source ^ 
-| Fiber stabilization, carbonization, electrolysis and washing | yes | 0.984 kg per kg product | 
-| Exhaust gas treatment 1 | yes | 36.25 kg per kg product | 
-| Exhaust gas treatment 2 (regenerative thermal oxidizer) | yes | 10.61 kg per kg product | 
-| Fiber drying and sizing | yes | 1 kg per kg product | 
- 
-==== 2.4 Cut-off criteria ==== 
- 
-No intentional cut-off; missing items are listed as data gaps. Flows excluded by cut-off are listed with their estimated mass/energy share in Section 4.6. 
- 
-==== 2.5 Allocation procedures ==== 
- 
-No co-product allocation (single reference product). 
- 
-==== 2.6 LCIA method and impact categories ==== 
- 
-EF v3.1 (European Commission, Joint Research Centre 2022), all impact categories, characterisation only. Normalisation and weighting are not applied (optional elements, ISO 14044 4.4.3); no weighting is used for any comparison. 
- 
-==== 2.7 Data requirements and data quality requirements (ISO 14044 4.2.3.6) ==== 
- 
-^ Requirement ^ Target ^ Achieved (see Section 4.5) ^ 
-| Time-related coverage | 2020–2026 data | 2020-2025, reference year 2024 | 
-| Geographical coverage | Asia | 13 geographical proxy dataset(s): Chemical plant, organics: ‘Chemical plant, organics’ used at RER (no RAS version) — geographical pro; Tap water, at user: ‘Tap water, at user’ used at RER (no RAS version) — geographical proxy; Wastewater treatment, sewage, class 5: ‘Treatment, sewage, to wastewater treatment, class 5’ used at; Water, deionised, at plant: ‘Water, deionised, at plant’ used at CH (no RAS version) — geographical ; Transport, freight, lorry, diesel, 40t gross weight, 2006, EURO-IV, long haul: ‘Transport, freight, ; Transport, freight, rail: ’Transport, freight, rail’ used at RER (no RAS version) — geographical pro | 
-| Technology coverage | current industrial technology | Section 3 | 
-| Precision | lognormal uncertainty and pedigree on every flow (Frischknecht 2023) | lognormal on every exchange; Monte Carlo GWP100 95 % interval 59.8–69.4 | 
-| Completeness | all inventory classes (raw materials, catalyst, neutralisation, water, energy, emissions to air/water/soil, by-products, infrastructure, transport) | all classes present | 
-| Representativeness | market-weighted route and feedstock | Section 3 (market and routes) | 
-| Consistency | one modelling approach for all regions/grades | family and regional checks: ok | 
-| Reproducibility | every value computed by a tool or cited | all amounts reproduced by tdc-doc | 
-| Sources of data | ≥ 3 peer-reviewed articles (Crossref-verified), ≥ 1 patent, ≥ 1 grey document | 15 references, 6 with DOI, 1 patent(s) | 
-| Uncertainty of information | Monte Carlo on the pedigree distributions | Section 6.5 | 
- 
-==== 2.8 Assumptions and limitations ==== 
- 
-  * none recorded 
- 
-==== 2.9 Type of critical review ==== 
- 
-External critical review by an independent expert (ISO/TS 14071) — pending. 
- 
-===== 3 Product, market and technology ===== 
- 
-==== 3.1 Product definition and grades ==== 
- 
-See the product exchange. 
- 
-==== 3.2 Market, production volumes and production routes ==== 
- 
-Product: PAN-based, wet-spun, intermediate-modulus (IM) carbon fiber, sized. Functional unit: 1 kg of sized IM carbon fiber. Scope starts at the regional PAN precursor fiber (cf-v2-precursor-RER); the precursor chain is a separate dataset. 
- 
-== 3.2.0.1 1. Production routes in commercial use and their shares == 
- 
-The commercial route for the largest share of PAN carbon fiber is: acrylonitrile -> (polymerization -> dope -> wet spinning -> coagulation -> washing -> stretching -> drying -> solvent recovery) -> PAN precursor fiber -> oxidative stabilization (air, 200-300 C) -> carbonization (inert, up to the grade temperature) -> surface treatment -> sizing -> finished fiber. [patent US5804108A] 
- 
-Wet spinning of PAN is the dominant precursor route for IM/standard grades. Alternative routes (dry-jet wet spinning for high-modulus/high-strength; pitch and polyimide precursors) are minor for the IM grade. IM-grade definition: tensile modulus ~265-320 GPa, processed up to ~1500 C, no graphitization (graphitization >= 2000 C is reserved for HM/UHM). [Fitzgerald 2024 thesis; Lenter 2023; Newcomb 2016] 
- 
-Most widely used route for this grade = PAN wet-spun precursor + air stabilization + two-stage carbonization + electrochemical surface treatment + epoxy sizing. 
- 
-== 3.2.0.2 2. Raw materials and origins (market shares by region) == 
- 
-  * PAN precursor fiber: the dominant raw material for IM carbon fiber (PAN accounts for the large majority of CF production; pitch/polyimide are minor). For RER, the precursor is sourced from the European precursor chain (acrylonitrile, propylene ammoxidation). 
-  * Acrylonitrile (AN): the monomer. China is the world’s largest AN producer (~50% of global capacity, 5.189 Mt/yr end-2025) [Baidu Baike 2025]. Global AN capacity was 7.2 Mt in 2018 with production 5.7 Mt [HDIN 2018]. Regional AN capacity (2018): China 2.1 Mt, APAC ex-China 2.1 Mt, Europe 1.9 Mt, North America 0.9 Mt, MEA 0.2 Mt [HDIN 2018]. 
-  * Sizing agent: epoxy resin (or polyurethane), 0.8-2.0 wt% of the sized fiber [Lenter 2023]. 
-  * Utilities: N2 (carbonization atmosphere), air (stabilization), steam/heat, electricity, natural gas for off-gas abatement [Khayyam 2021; harmonizing LCA-CF notes]. 
- 
-== 3.2.0.3 3. Production volumes (tonnes/year, with year) == 
- 
-== 3.2.0.3.1 Carbon fiber (product) == 
- 
-  * World demand 2025: ~148,500 t (CAGR 2010-2025 +10.55%; +17.39% YoY) [CU 2025]. 
-  * World operational capacity 2025: 326,080 t (309,000 t in 2024, +5.5% YoY) [ATA 2025]. 
-  * China operational capacity 2025: 171,080 t = 52.5% of global capacity (48.6% in 2024) [ATA 2025]. 
-  * Main producing regions: Asia (China >50%, plus Japan/Korea), Europe (RER, Toray/Syensqo/Hexpol), North America (Syensqo Rock Hill, SC). RER capacity is a smaller share than Asia or North America; Toray’s French plant ~5-6 kt/yr, Syensqo Kelheim precursor ~9 M lb [ATA 2025]. 
- 
-== 3.2.0.3.2 PAN precursor / acrylonitrile (main raw material) == 
- 
-  * Acrylonitrile world capacity ~7.2 Mt (2018) -> ~10 Mt projected (2024) [HDIN 2018]. 
-  * China AN capacity 5.189 Mt/yr (end-2025) = ~50% of global [Baidu Baike 2025]. 
-  * Europe AN capacity ~1.9 Mt (2018) [HDIN 2018] — basis for the RER precursor provenance. 
-  * PAN precursor fiber: produced by the major CF producers (Toray, Teijin, Syensqo, Jilin, Zhongfu, Hyosung) either integrated with the CF line or sold separately. For RER the precursor is assumed produced in-region from European acrylonitrile. 
- 
-== 3.2.0.4 4. Default route and feedstock choice == 
- 
-Default route for all three regions = the largest-volume commercial route: PAN wet-spun precursor + air stabilization + two-stage inert carbonization + electrochemical surface treatment + epoxy sizing. Feedstock = wet-spun PAN precursor fiber of the region. Alternative route (dry-jet wet spinning for the precursor) is noted but not modeled (it is the route for higher-modulus/higher-strength grades, not IM). 
- 
-Sources: [1] Composites United e.V., “Market Report 2025 - The Global Market for Carbon Fibers and Carbon Composites”, composites-united.com (world demand ~148,500 t, 2025). [2] ATA CFT, “2025 Global Carbon Fiber Composites Market Report”, compositesworld.com (world capacity 326,080 t 2025; China 171,080 t = 52.5%). [3] HDIN Research, “Acrylonitrile (ACN) production capacity reached 7.2 Mt in 2018”, hdinresearch.com/news/30 (AN capacity by region). [4] Baidu Baike, “Acrylonitrile Industry” (2025) (China AN capacity 5.189 Mt = ~50% global). [5] patent US5804108A, “Process for the preparation of carbon fiber”. [6] Lenter 2023; Newcomb 2016; Fitzgerald 2024 (grade definition, sizing, routes). 
- 
-^ Item ^ Value ^ Year ^ Source ^ 
- 
-==== 3.3 Process description ==== 
- 
-Conversion of 1 kg of wet-spun PAN precursor fiber into 1 kg of sized, intermediate modulus (IM) carbon fiber: stabilization (oxidation in air), low- and high-temperature carbonisation, surface treatment, sizing and drying, with exhaust-gas treatment and plant utilities. The PAN precursor fiber itself (acrylonitrile polymerisation, wet spinning, coagulation, washing, stretching, drying, solvent recovery) is a separate tdc dataset cf-v2-precursor-RER. Processing steps as recorded in the unit process: 
- 
-^ Step ^ Conditions (T, p, time) ^ Main inputs/outputs ^ Source ^ 
-| Low-temperature carbonization (inert atmosphere, up to 1000 C) | Stabilized fiber heated in N2 to ~1000 C; carbon rings form, H/N/O removed as off-gas; ~50% mass loss. |  | [] | 
-| Oxidative stabilization (air, 200-300 C) | The wet-spun PAN precursor fiber is heated to 200-300 C in air (recirculating oxidizer oven) for 1-2 h under tension, cross-linking the PAN to a stable ladder structure; ~10% mass loss. |  | [] | 
-| High-temperature carbonization (inert atmosphere, up to 1800 C) | Fiber heated in N2 to 1500-1800 C in a graphite furnace; graphitic crystallites grow; ~21% mass loss. IM grade stops here (no graphitisation). |  | [] | 
-| Sizing and final winding | The dry fiber is coated with an epoxy sizing agent and wound onto spools. |  | [] | 
-| Surface treatment (electrochemical oxidation) | The fiber is etched in an acidic (HNO3) electrolysis bath, the conductive fiber as anode, improving sizing adhesion. |  | [] | 
-| Washing and drying | The etched fiber is washed and the sizing-bath water is removed in technical drying (closed-loop recovered water). |  | [] | 
- 
-===== 4 Life cycle inventory analysis (ISO 14044, 4.3) ===== 
- 
-==== 4.1 Data collection ==== 
- 
-Two-step literature search: (1) the user’s embedded reference library (local vector search, — queries, 0 excerpts retained), then (2) a web and database round (scholarly indexes, patents, agency and industry documents) to complete the process description. Each reference was verified (DOI against Crossref; patents against the patent office record; other documents fetched and the quoted passage found in the text). Reference statistics: 15 references, 6 Crossref-verified articles, 1 patents, 8 grey documents. 
- 
-==== 4.2 Calculation procedures ==== 
- 
-=== 4.2.1 Stoichiometry and mass/element balances === 
- 
-Stoichiometric model of the dataset (spec.json), recomputed by tdc-doc: balances pass. Balances computed by the tdc stoichiometry model (Annex B): 
- 
-^ Balance ^ In (kg) ^ Out (kg) ^ Residual (%) ^ 
-| C | — | — | -0 | 
-| H | — | — | -0.001 | 
-| N | — | — | 0 | 
-| O | — | — | 0 | 
-| mass | — | — | 0 | 
- 
-=== 4.2.2 Energy model === 
- 
-Heat and electricity are computed per consumer from process physics with the tdc energy model (Annex A); each parameter is cited or declared as an assumption. 
- 
-^ Consumer ^ Energy form ^ Duty / power ^ Time ^ Energy per kg ^ Source ^ 
-| [Fiber stabilization, carbonization, electrolysis and washing] Fiber sensible heat, stabilization (25 to 300 C) | heat (electric) | — | — | 1.147 MJ | [Precursor mass 2.7815 kg per kg of core fiber = 2.73704 kg per kg product / 0.984 (Benitez 2021 T700G anchor; stoich spec.json) (stoich elem] | 
-| [Fiber stabilization, carbonization, electrolysis and washing] Stabilization oven air heating (recirculating oxidizer air) | heat (electric) | — | — | 36.37 MJ | [‘the air is heated in an electric heater to a predetermined temperature and heats the processed fibers due to convective heat exchange’ (IJA] | 
-| [Fiber stabilization, carbonization, electrolysis and washing] Fiber sensible heat, low-temperature carbonization (300 to 1000 C) | heat (electric) | — | — | 1.75 MJ | [Stabilized fiber 2.5000 kg per kg core (2.460 kg per kg product / 0.984; harmonizing mass balance: precursor 2.737 -> stabilized 2.460, 10.0] | 
-| [Fiber stabilization, carbonization, electrolysis and washing] Fiber sensible heat, high-temperature carbonization (1000 to 1800 C) | heat (electric) | — | — | 1 MJ | [Mid-route fiber (low-T carbonisation product) 1.2500 kg per kg core (1.230 kg per kg product / 0.984; harmonizing mass balance LT carbonisat] | 
-| [Fiber stabilization, carbonization, electrolysis and washing] Carbonisation + surface-treatment stage powers: N2 purge heating, wall losses, electrolysis, drives (sourced RSC stage kW residual) | heat (electric) | — | — | 29.28 MJ | [RSC_ESI_2016 Table 1 sourced stage powers.] | 
-| [Fiber stabilization, carbonization, electrolysis and washing] Stabilization furnace NG burner (on-site gas assist, 0.22 kg NG per kg product) | heat (fuel) | — | — | 6.803 MJ | [Sourced on-site NG for the stabilization oxidation furnace (carrier fuel). Per user decision 4 the on-site fuel is carried by the energy mod] | 
-| [Fiber stabilization, carbonization, electrolysis and washing] Inert gas make-up compression (N2, slight overpressure of the carbonisation atmospheres) | electricity | 0.4109 | 1 | 0.4109 kWh | [All nitrogen purchased externally (JapanCFMA_LCI_2022 sec 5-3-6: ‘All nitrogen was purchased externally’); inert N2 for carbonisation (Prenz] | 
-| [Fiber stabilization, carbonization, electrolysis and washing] Fiber line tensioner drives, furnace drive trains, electrolysis and washing drives | electricity | 3.378 | 1 | 3.378 kWh | [Continuous line under constant tension (Prenzel2023 sec 3.1.1) with drive trains per furnace; 3.04 kW per kg/h of core (3 kW per kg/h produc] | 
-| [Exhaust gas treatment 1] First off-gas treatment (quench/wash/scrubber) specific energy | electricity (utility) | — | — | 0.023 kWh | [First exhaust-gas treatment of the continuous CF line (before the RTO); BAFU dataset ‘Carbon fiber production, exhaust gas treatment 1’ has ] | 
-| [Exhaust gas treatment 2 (regenerative thermal oxidizer)] Regenerative thermal oxidizer NG fuel (on-site, 2.06 kg NG per kg product) | heat (fuel) | — | — | 5.908 MJ | [Sourced on-site RTO fuel (carrier fuel). This plus the step-1 stabilization NG (0.22 kg) = the spec.json stoich NG reactant 2.28 kg per kg p] | 
-| [Exhaust gas treatment 2 (regenerative thermal oxidizer)] RTO fans and blower (off-gas and oxidising-air circulation) | electricity (utility) | — | — | 0.0262 kWh | [RTO fans and post-treatment blower of the regenerative thermal oxidizer; the sourced RSC_ESI_2016 abatement system (25 kW at 12.5 kg/h) incl] | 
-| [Fiber drying and sizing] Sizing-bath water heating (technical drying, recovered closed loop) | heat (electric) | — | — | 1.2 MJ | [The sizing-bath water is a recovered closed loop: ’the water evaporates in technical drying, is recovered and fed back; the coating remains ] | 
-| [Fiber drying and sizing] Drying air handling + winding drives (sourced RSC stage powers) | electricity | 1.2 | 1 | 1.2 kWh | [RSC_ESI_2016 Table 1 sourced stage powers (measured, 100 t/a pilot line) - independent of the Benitez2021 benchmark.] | 
- 
-Totals per kg: heat 69.38 MJ, electricity 28.8 kWh, primary energy — MJ. 
- 
-=== 4.2.3 Emissions === 
- 
-Direct emissions: Carbon dioxide, fossil (to air) 3.319 kg; Water, off-gas vapor (to air) 1.253 kg; Nitrogen, off-gas (to air) 9.528 kg; Nitrogen oxides, fossil (to air) 0.00012 kg; Hydrogen cyanide (to air) 0.00191 kg; Carbon monoxide, fossil (to air) 0.009236 kg; Ammonia (to air) 0.001357 kg; Methane (to air) 0.001444 kg; Ethylene (to air) 0.001366 kg; Ethane (to air) 0.001314 kg. 
- 
-=== 4.2.4 Transport === 
- 
-Statistical transport from the provenance of each raw material to the plant region (Annex C): Transport, freight, lorry, diesel, 40t gross weight, 2006, EURO-IV, long haul 1.263 tkm; Transport, freight, rail 2.095 tkm; Transport, barge 2.356 tkm; Transport, transoceanic freight ship 2.311 tkm 
- 
-=== 4.2.5 Infrastructure === 
- 
-Chemical plant, organics 8e-10 p 
- 
-==== 4.3 Inventory table ==== 
- 
-Per 1 kg of sized, intermediate modulus (IM) carbon fiber, PAN-based, wet spun of product. GSD² = squared geometric standard deviation of the lognormal distribution; pedigree scores (reliability, completeness, temporal, geographical, technological) per BAFU DQR v2.1 (Frischknecht 2023). 
- 
-^ Exchange ^ Direction ^ Amount ^ Unit ^ BAFU dataset / elementary flow ^ GSD² ^ Pedigree ^ Source ^ 
-| Electricity, medium voltage, production RAS, at grid | input | 28.796 | kWh | Electricity, medium voltage, production RAS, at grid [RAS] | 1.13 | (3,3,2,1,1) | [—] | 
-| Chemical plant, organics | input | 8e-10 | p | Chemical plant, organics [RER] | 3.06 | (4,3,3,1,1) | [—] | 
-| Tap water, at user | input | 0.61 | kg | Tap water, at user [RER] | 1.13 | (3,3,2,1,1) | [—] | 
-| Wastewater treatment, sewage, class 5 | input | 0.00061 | m3 | Treatment, sewage, to wastewater treatment, class 5 [CH] | 1.13 | (3,3,2,1,1) | [—] | 
-| Water, deionised, at plant | input | 8.114e-05 | kg | Water, deionised, at plant [CH] | 1.13 | (3,3,2,1,1) | [—] | 
-| Transport, freight, lorry, diesel, 40t gross weight, 2006, EURO-IV, long haul | input | 1.2634 | tkm | Transport, freight, lorry, diesel, 40t gross weight, 2006, EURO-IV, long haul [RER] | 3.02 | (3,3,2,2,1) | [—] | 
-| Transport, freight, rail | input | 2.0946 | tkm | Transport, freight, rail [RER] | 2.02 | (3,3,2,2,1) | [—] | 
-| Transport, barge | input | 2.3564 | tkm | Transport, barge [RER] | 2.02 | (3,3,2,2,1) | [—] | 
-| Transport, transoceanic freight ship | input | 2.3113 | tkm | Transport, transoceanic freight ship [OCE] | 2.02 | (3,3,2,2,1) | [—] | 
-| Sizing agent, epoxy | input | 0.016 | kg | Epoxy resin, liquid, at plant [RER] | 1.13 | (3,3,2,1,1) | [—] | 
-| Oxygen, resource in air | input | 3.5406 | kg | Oxygen | 1.22 | (4,3,2,1,1) | [—] | 
-| Nitrogen, liquid, at plant | input | 8.822 | kg | Nitrogen, liquid, at plant [RER] | 1.13 | (3,3,2,1,1) | [—] | 
-| Ammonium bicarbonate, at plant | input | 0.01842 | kg | Ammonium bicarbonate, at plant [RER] | 1.13 | (3,3,2,1,1) | [—] | 
-| Ethylene glycol, at plant | input | 0.0076 | kg | Ethylene glycol, at plant [RER] | 1.13 | (3,3,2,1,1) | [—] | 
-| Carbon dioxide, fossil (to air) | output | 3.3185 | kg | Carbon dioxide, fossil | 1.22 | (4,3,2,1,1) | [—] | 
-| Water, off-gas vapor (to air) | output | 1.2528 | kg | Water | 1.57 | (4,3,2,1,1) | [—] | 
-| Nitrogen, off-gas (to air) | output | 9.5277 | kg | Nitrogen | 1.57 | (4,3,2,1,1) | [—] | 
-| Nitrogen oxides, fossil (to air) | output | 0.00012 | kg | Nitrogen oxides | 1.57 | (4,3,2,1,1) | [—] | 
-| Hydrogen cyanide (to air) | output | 0.00191 | kg | Cyanide | 1.57 | (4,3,2,1,1) | [—] | 
-| Carbon monoxide, fossil (to air) | output | 0.009236 | kg | Carbon monoxide, fossil | 5.06 | (4,3,2,1,1) | [—] | 
-| Ammonia (to air) | output | 0.001357 | kg | Ammonia | 1.57 | (4,3,2,1,1) | [—] | 
-| Methane (to air) | output | 0.001444 | kg | Methane, fossil | 1.57 | (4,3,2,1,1) | [—] | 
-| Ethylene (to air) | output | 0.001366 | kg | NMVOC, non-methane volatile organic compounds | 1.57 | (4,3,2,1,1) | [—] | 
-| Ethane (to air) | output | 0.001314 | kg | Ethane | 2.05 | (4,3,2,1,1) | [—] | 
-| Heat, natural gas, at heat plant | input | 69.381 | MJ | Heat, natural gas, at heat plant [JP] | 1.13 | (3,3,2,1,1) | [—] | 
-| PAN precursor fiber, wet spun | input | 2.737 | kg | tdc dataset cf-v2-precursor-ras | 1.13 | (3,3,2,1,1) | [—] | 
- 
-==== 4.4 Data quality assessment ==== 
- 
-Energy verification per sub-process (policy B): Fiber stabilization, carbonization, electrolysis and washing: physics, 5 independent reference(s); Exhaust gas treatment 1: literature, 1 independent reference(s); Exhaust gas treatment 2 (regenerative thermal oxidizer): literature, 2 independent reference(s); Fiber drying and sizing: literature, 3 independent reference(s). Pedigree scores: 26 of 26 exchanges scored by the developer; the others carry the tdc-doc default (3, 3, 3, 3, 3) (marked *). Proxies (BAFU datasets that do not represent exactly the flow): Chemical plant, organics → Chemical plant, organics (Chemical plant, organics: ‘Chemical plant, organics’ used at RER (no RAS version) — geographical proxy); Tap water, at user → Tap water, at user (Tap water, at user: ‘Tap water, at user’ used at RER (no RAS version) — geographical proxy); Wastewater treatment, sewage, class 5 → Treatment, sewage, to wastewater treatment, class 5 (Wastewater treatment, sewage, class 5: ‘Treatment, sewage, to wastewater treatment, class 5’ used at CH (no RAS version) — geographical proxy); Water, deionised, at plant → Water, deionised, at plant (Water, deionised, at plant: ‘Water, deionised, at plant’ used at CH (no RAS version) — geographical proxy); Transport, freight, lorry, diesel, 40t gross weight, 2006, EURO-IV, long haul → Transport, freight, lorry, diesel, 40t gross weight, 2006, EURO-IV, long haul (Transport, freight, lorry, diesel, 40t gross weight, 2006, EURO-IV, long haul: ‘Transport, freight, lorry, diesel, 40t gross weight, 2006, EURO-IV, long haul’ used at RER (no RAS version) — geographic); Transport, freight, rail → Transport, freight, rail (Transport, freight, rail: ‘Transport, freight, rail’ used at RER (no RAS version) — geographical proxy); Transport, barge → Transport, barge (Transport, barge: ‘Transport, barge’ used at RER (no RAS version) — geographical proxy); Transport, transoceanic freight ship → Transport, transoceanic freight ship (Transport, transoceanic freight ship: ‘Transport, transoceanic freight ship’ used at OCE (no RAS version) — geographical proxy); Sizing agent, epoxy → Epoxy resin, liquid, at plant (Sizing agent, epoxy: ‘Epoxy resin, liquid, at plant’ used at RER (no RAS version) — geographical proxy); Nitrogen, liquid, at plant → Nitrogen, liquid, at plant (Nitrogen, liquid, at plant: ‘Nitrogen, liquid, at plant’ used at RER (no RAS version) — geographical proxy); Ammonium bicarbonate, at plant → Ammonium bicarbonate, at plant (Ammonium bicarbonate, at plant: ‘Ammonium bicarbonate, at plant’ used at RER (no RAS version) — geographical proxy); Ethylene glycol, at plant → Ethylene glycol, at plant (Ethylene glycol, at plant: ‘Ethylene glycol, at plant’ used at RER (no RAS version) — geographical proxy); Heat, natural gas, at heat plant → Heat, natural gas, at heat plant (Heat, natural gas, at heat plant: ‘Heat, natural gas, at heat plant’ used at JP (no RAS version) — geographical proxy). 
- 
-==== 4.5 Data gaps and assumptions register ==== 
- 
-^ Item ^ Class ^ Value used ^ Reason / queries tried ^ Effect (Section 6.3) ^ 
- 
-==== 4.6 Validation of data (ISO 14044 4.3.3.2) ==== 
- 
-  * Mass and element balances: Section 4.2.1. 
-  * Cross-check with independent data: BAFU datasets of similar processes (Carbon fiber production, fiber stabilization, carbonization, electrolysis and washing, Carbon fiber production, exhaust gas treatment 2, Carbon fiber production, fiber drying and sizing) and published values (Section 6.6); deviations beyond a factor of 3 are justified with a cited excerpt. 
-  * Independent second-model review (Gemma-4-26B-A4B-it-GGUF): 4 finding(s), review of 2026-10-28 12:33 (Annex E). 
-  * Citation test: every quoted excerpt was found in its source text (all found). 
-  * Independent recalculation by tdc-doc: independent recalculation of GWP100 = pipeline LCIA (lcia.json): PASS. 
- 
-===== 5 Life cycle impact assessment (EF v3.1) ===== 
- 
-Characterisation results per 1 kg of sized, intermediate modulus (IM) carbon fiber, PAN-based, wet spun, computed with bw2calc on the BAFU 2026 v1 database (Mutel 2017; European Commission, Joint Research Centre 2022). 
- 
-^ Impact category ^ Indicator ^ Unit ^ Result ^ 
-| acidification | accumulated exceedance (AE) | mol H+-Eq | 0.178 | 
-| climate change | global warming potential (GWP100) | kg CO2-Eq | 64.1 | 
-| climate change: biogenic | global warming potential (GWP100) | kg CO2-Eq | 0.1821 | 
-| climate change: fossil | global warming potential (GWP100) | kg CO2-Eq | 63.91 | 
-| climate change: land use and land use change | global warming potential (GWP100) | kg CO2-Eq | 0.009981 | 
-| ecotoxicity: freshwater | comparative toxic unit for ecosystems (CTUe) | CTUe | 287.4 | 
-| ecotoxicity: freshwater, inorganics | comparative toxic unit for ecosystems (CTUe) | CTUe | 263.5 | 
-| ecotoxicity: freshwater, organics | comparative toxic unit for ecosystems (CTUe) | CTUe | 23.95 | 
-| energy resources: non-renewable | abiotic depletion potential (ADP): fossil fuels | MJ, net calorific value | 984 | 
-| eutrophication: freshwater | fraction of nutrients reaching freshwater end compartment (P) | kg P-Eq | 0.01314 | 
-| eutrophication: marine | fraction of nutrients reaching marine end compartment (N) | kg N-Eq | 0.03106 | 
-| eutrophication: terrestrial | accumulated exceedance (AE) | mol N-Eq | 0.4719 | 
-| human toxicity: carcinogenic | comparative toxic unit for human (CTUh) | CTUh | 2.27e-08 | 
-| human toxicity: carcinogenic, inorganics | comparative toxic unit for human (CTUh) | CTUh | 1.045e-08 | 
-| human toxicity: carcinogenic, organics | comparative toxic unit for human (CTUh) | CTUh | 1.225e-08 | 
-| human toxicity: non-carcinogenic | comparative toxic unit for human (CTUh) | CTUh | 5.006e-07 | 
-| human toxicity: non-carcinogenic, inorganics | comparative toxic unit for human (CTUh) | CTUh | 4.829e-07 | 
-| human toxicity: non-carcinogenic, organics | comparative toxic unit for human (CTUh) | CTUh | 1.776e-08 | 
-| ionising radiation: human health | human exposure efficiency relative to u235 | kBq U235-Eq | 9.799 | 
-| land use | soil quality index | dimensionless | 151.1 | 
-| material resources: metals/minerals | abiotic depletion potential (ADP): elements (ultimate reserves) | kg Sb-Eq | 6.487e-05 | 
-| ozone depletion | ozone depletion potential (ODP) | kg CFC-11-Eq | 1.077e-06 | 
-| particulate matter formation | impact on human health | disease incidence | 1.491e-06 | 
-| photochemical oxidant formation: human health | tropospheric ozone concentration increase | kg NMVOC-Eq | 0.1203 | 
-| water use | user deprivation potential (deprivation-weighted water consumption) | m3 world eq. deprived | 5.493 | 
- 
-{{ :datasets:tdc:c724fe59-4f68-5735-a13e-4edb0d44388d:contribution.png?900|Contribution of the inventory items to climate change (GWP100) and the other main categories. }} 
- 
-//Contribution of the inventory items to climate change (GWP100) and the other main categories.// 
- 
-Climate change 64.1 kg CO2-eq per kg. Main contributors: PAN precursor fiber, wet spun 49 %; Electricity, medium voltage, production RAS, at grid 33 %; Heat, natural gas, at heat plant 9 %; Carbon dioxide, fossil (to air) 5 %; Nitrogen, liquid, at plant 3 %. 
- 
-===== 6 Interpretation (ISO 14044, 4.5) ===== 
- 
-==== 6.1 Significant issues ==== 
- 
-The inventory items that dominate climate change are PAN precursor fiber, wet spun 49 %; Electricity, medium voltage, production RAS, at grid 33 %; Heat, natural gas, at heat plant 9 %; Carbon dioxide, fossil (to air) 5 %; Nitrogen, liquid, at plant 3 %. The parameters with the largest effect (Section 6.3) are: PAN precursor fiber, wet spun (pedigree 95 % interval) (-6 / +6 %); Fiber stabilization, carbonization, electrolysis and washing: electricity_kWh (per kg step output) (+2 / +6 %); Electricity, medium voltage, production RAS, at grid (pedigree 95 % interval) (-4 / +4 %). 
- 
-==== 6.2 Completeness check ==== 
- 
-board stage ‘inventory’ (closed + automatic check re-run): PASS; inventory completeness (classes, no zero amounts): PASS; every exchange scored in EF v3.1 (linked to BAFU / biosphere): PASS 
- 
-==== 6.3 Sensitivity check ==== 
- 
-One-at-a-time variation of (a) every assumption of Section 4.6 over its plausible range and (b) every parameter for which the literature gives a range or several values (Annex D); scenarios for alternative routes, feedstocks and regions. 
- 
-^ Parameter ^ Base ^ Low / high ^ Source of the range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ 
-| PAN precursor fiber, wet spun (pedigree 95 % interval) | 2.73704 | /1.13 / x1.13 | [pedigree (Annex H)] | -5.6 / +6.3 | 11.7 | 
-| Fiber stabilization, carbonization, electrolysis and washing: electricity_kWh (per kg step output) | 26.5169 | 28.2264 / 31.77 | [Benitez A, Wulf C, de Palmenaer A, et al. Ecologic; harmonizing_lca_cf_notes per-step electricity for] | +1.9 / +5.8 | 11.7 | 
-| Electricity, medium voltage, production RAS, at grid (pedigree 95 % interval) | 28.79649 | /1.13 / x1.13 | [pedigree (Annex H)] | -3.7 / +4.2 | 8.4 | 
-| Exhaust gas treatment 2 (regenerative thermal oxidizer): electricity_kWh (per kg step output) | 0.0262 | 0.0262 / 0.1885 | [Benitez A, Wulf C, de Palmenaer A, et al. Ecologic; RSC_ESI_2016 Table 1 ‘Abatement system 25 kW’ at 1] | +0.0 / +1.9 | 3.9 | 
-| Exhaust gas treatment 2 (regenerative thermal oxidizer): heat_MJ (per kg step output) | 5.9082 | 6.93 / 6.951 | [Benitez2021 benchmark sub-process ’carbon fiber pr; harmonizing_lca_cf_notes: ’Natural Gas: Exhaust tr] | +1.5 / +1.5 | 3.4 | 
-| Heat, natural gas, at heat plant (pedigree 95 % interval) | 69.38065 | /1.13 / x1.13 | [pedigree (Annex H)] | -1.1 / +1.2 | 2.7 | 
-| Carbon dioxide, fossil (to air) (pedigree 95 % interval) | 3.31853 | /1.22 / x1.22 | [pedigree (Annex H)] | -0.9 / +1.1 | 1.1 | 
-| Fiber drying and sizing: electricity_kWh (per kg step output) | 1.5922 | 0.6257 / 0.6257 | [Benitez A, Wulf C, de Palmenaer A, et al. Ecologic] | -1.1 / -1.1 | 2.2 | 
-| Transport, freight, lorry, diesel, 40t gross weight, 2006, EURO-IV, long haul (pedigree 95 % interval) | 1.26343 | /3.02 / x3.02 | [pedigree (Annex H)] | -0.2 / +0.6 | 14.2 | 
-| Nitrogen, liquid, at plant (pedigree 95 % interval) | 8.82203 | /1.13 / x1.13 | [pedigree (Annex H)] | -0.4 / +0.4 | 3.4 | 
-| Fiber stabilization, carbonization, electrolysis and washing: heat_MJ (per kg step output) | 6.8035 | 4.6509 / 4.6509 | [Benitez A, Wulf C, de Palmenaer A, et al. Ecologic] | -0.3 / -0.3 | 0.6 | 
-| Exhaust gas treatment 1: electricity_kWh (per kg step output) | 0.023 | 0.02 / 0.0229 | [Benitez A, Wulf C, de Palmenaer A, et al. Ecologic; Benitez2021 benchmark sub-process ‘carbon fiber pr; RSC_ESI_2016 Table 1 ’Abatement system 25 kW’ at 1] | -0.1 / -0.0 | 0.2 | 
-| Fiber drying and sizing: heat_MJ (per kg step output) | 0.0 | 0.3351 / 0.3351 | [Benitez A, Wulf C, de Palmenaer A, et al. Ecologic] | +0.0 / +0.0 | 0.1 | 
- 
-==== 6.4 Consistency check ==== 
- 
-Final control: 22 item(s) passed; no failure. 
- 
-==== 6.5 Uncertainty analysis ==== 
- 
-Monte Carlo simulation (1000 runs) on the lognormal distributions of all exchanges: 
- 
-^ Impact category ^ Median ^ 2.5 % ^ 97.5 % ^ GSD² ^ 
-| acidification / accumulated exceedance (AE) | 0.1787 | 0.1651 | 0.1938 | 1.08 | 
-| climate change / global warming potential (GWP100) | 64.2 | 59.83 | 69.43 | 1.08 | 
-| climate change: biogenic / global warming potential (GWP100) | 0.1823 | 0.1701 | 0.1959 | 1.07 | 
-| climate change: fossil / global warming potential (GWP100) | 64.01 | 59.65 | 69.23 | 1.08 | 
-| climate change: land use and land use change / global warming potential (GWP100) | 0.0101 | 0.009208 | 0.01152 | 1.12 | 
-| ecotoxicity: freshwater / comparative toxic unit for ecosystems (CTUe) | 288.1 | 267.1 | 312.5 | 1.08 | 
-| ecotoxicity: freshwater, inorganics / comparative toxic unit for ecosystems (CTUe) | 264 | 245.5 | 285.6 | 1.08 | 
-| ecotoxicity: freshwater, organics / comparative toxic unit for ecosystems (CTUe) | 24.08 | 21.44 | 26.97 | 1.12 | 
-| energy resources: non-renewable / abiotic depletion potential (ADP): fossil fuels | 985.9 | 909.4 | 1073 | 1.09 | 
-| eutrophication: freshwater / fraction of nutrients reaching freshwater end compartment (P) | 0.01318 | 0.01224 | 0.01419 | 1.08 | 
-| eutrophication: marine / fraction of nutrients reaching marine end compartment (N) | 0.03121 | 0.02911 | 0.03363 | 1.07 | 
-| eutrophication: terrestrial / accumulated exceedance (AE) | 0.4744 | 0.4394 | 0.5154 | 1.08 | 
-| human toxicity: carcinogenic / comparative toxic unit for human (CTUh) | 2.279e-08 | 2.11e-08 | 2.461e-08 | 1.08 | 
-| human toxicity: carcinogenic, inorganics / comparative toxic unit for human (CTUh) | 1.051e-08 | 9.683e-09 | 1.144e-08 | 1.09 | 
-| human toxicity: carcinogenic, organics / comparative toxic unit for human (CTUh) | 1.227e-08 | 1.139e-08 | 1.322e-08 | 1.08 | 
-| human toxicity: non-carcinogenic / comparative toxic unit for human (CTUh) | 5.022e-07 | 4.606e-07 | 5.454e-07 | 1.09 | 
-| human toxicity: non-carcinogenic, inorganics / comparative toxic unit for human (CTUh) | 4.845e-07 | 4.438e-07 | 5.267e-07 | 1.09 | 
-| human toxicity: non-carcinogenic, organics / comparative toxic unit for human (CTUh) | 1.791e-08 | 1.649e-08 | 1.943e-08 | 1.09 | 
-| ionising radiation: human health / human exposure efficiency relative to u235 | 9.82 | 9.199 | 10.55 | 1.07 | 
-| land use / soil quality index | 151.6 | 140.3 | 163.6 | 1.08 | 
-| material resources: metals/minerals / abiotic depletion potential (ADP): elements (ultimate reserves) | 6.56e-05 | 5.82e-05 | 7.864e-05 | 1.16 | 
-| ozone depletion / ozone depletion potential (ODP) | 1.082e-06 | 9.952e-07 | 1.179e-06 | 1.09 | 
-| particulate matter formation / impact on human health | 1.494e-06 | 1.381e-06 | 1.631e-06 | 1.09 | 
-| photochemical oxidant formation: human health / tropospheric ozone concentration increase | 0.1213 | 0.1126 | 0.1307 | 1.08 | 
-| water use / user deprivation potential (deprivation-weighted water consumption) | 5.496 | 5.098 | 5.949 | 1.08 | 
- 
-==== 6.6 Comparison with other data ==== 
- 
-^ Source ^ Scope ^ Value (GWP100 or energy) ^ This dataset ^ Ratio ^ Explanation ^ 
-| [BAFU 2026 dataset] | Carbon fiber, weaved, at factory (RER), cradle-to-gate incl. weaving | 51.5 kg CO2-eq | 64.1 | 1.25 | BAFU analog (Benitez 2021 inventory); includes weaving | 
-| [tdc dataset] | cf-v2-im-rer (same product, other region) | 51 kg CO2-eq | 64.1 | 1.26 | regional variant (electricity, heat, transport) | 
-| [tdc dataset] | cf-v2-im-rna (same product, other region) | 52.6 kg CO2-eq | 64.1 | 1.22 | regional variant (electricity, heat, transport) | 
-| [Benitez et al. 2021] | electricity, whole CF chain incl. precursor (per kg CF) | 43.2388 kWh | 28.8 kWh (this unit process) | — | different boundary when the precursor is a separate dataset | 
- 
-==== 6.7 Conclusions, limitations and recommendations ==== 
- 
-GWP100 64.1 kg CO2-eq per kg (95 % interval 59.8–69.4). Dominant contributors: PAN precursor fiber, wet spun 49 %; Electricity, medium voltage, production RAS, at grid 33 %; Heat, natural gas, at heat plant 9 %; Carbon dioxide, fossil (to air) 5 %; Nitrogen, liquid, at plant 3 %. Most sensitive parameters: PAN precursor fiber, wet spun (pedigree 95 % interval) (-6 / +6 %); Fiber stabilization, carbonization, electrolysis and washing: electricity_kWh (per kg step output) (+2 / +6 %); Electricity, medium voltage, production RAS, at grid (pedigree 95 % interval) (-4 / +4 %). Dataset status: ready for external review. 
- 
-===== 7 Critical review ===== 
- 
-//Reserved for the external reviewer (ISO 14044 clause 6; ISO/TS 14071 (//ISO/TS 14071:2014 Environmental Management — Life Cycle Assessment — Critical Review Processes and Reviewer Competencies// 2014)): reviewer, date, scope of the review, statement, and the response of the dataset developers.// 
- 
-^ Reviewer comment ^ Response ^ Change in the dataset ^ 
-|  |  |  | 
- 
-===== 8 References ===== 
- 
-BAFU (graph). 2026. //BAFU 2026 Carbon Fiber Production Sub-Processes (Stabilization/Carbonization/Electrolysis/Washing; EGT 1 & 2; Drying/Sizing), Based on Benitez 2021 / Ellringmann 2016//. bafu-graph: bolt://192.168.178.150:7688. 
- 
-Bell, Caleb. 2016a. //Fluids: Fluid Dynamics Component of Chemical Engineering Design Library (ChEDL)//. Released. [[https://github.com/CalebBell/fluids]]. 
- 
-Bell, Caleb. 2016b. //Thermo: Chemical Properties Component of Chemical Engineering Design Library (ChEDL)//. Released. [[https://github.com/CalebBell/thermo]]. 
- 
-Commission Recommendation (EU) 2021/2279 of 15 December 2021 on the Use of the Environmental Footprint Methods to Measure and Communicate the Life Cycle Environmental Performance of Products and Organisations, L 471 Official Journal of the European Union (2021). 
- 
-Dér, A., and et al. 2021. ‘Modelling and Analysis of the Energy Intensity in Polyacrylonitrile (PAN) Precursor and Carbon Fibre Manufacturing’. //Journal of Cleaner Production// 303: 127105. [[https://doi.org/10.1016/j.jclepro.2021.127105]]. 
- 
-European Commission, Joint Research Centre. 2022. //Environmental Footprint (EF) Reference Package 3.1//. European Commission JRC. 
- 
-Frischknecht, Rolf. 2023. //FOEN LCI Data — Data Quality Requirements (DQR) V2.1//. Treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU). 
- 
-Hao X, Li R, Wang J, Yang X. 2018. //Numerical Simulation of a Regenerative Thermal Oxidizer for Volatile Organic Compounds Treatment//. [[https://doi.org/10.4491/eer.2018.057]]. 
- 
-//ISO 14040:2006 Environmental Management — Life Cycle Assessment — Principles and Framework (Incl. Amd 1:2020)//. 2006. International Organization for Standardization. 
- 
-//ISO 14044:2006 Environmental Management — Life Cycle Assessment — Requirements and Guidelines (Incl. Amd 1:2017, Amd 2:2020)//. 2006. International Organization for Standardization. 
- 
-//ISO/TS 14071:2014 Environmental Management — Life Cycle Assessment — Critical Review Processes and Reviewer Competencies//. 2014. International Organization for Standardization. 
- 
-Khayyam, H., and et al. 2021. ‘Improving Energy Efficiency of Carbon Fiber Manufacturing Through Waste Heat Recovery: A Circular Economy Approach with Machine Learning’. //Energy// 225: 120113. [[https://doi.org/10.1016/j.energy.2021.120113]]. 
- 
-Lenter, E., and et al. 2023. //Is the Use of Bio-Based Raw Materials in Carbon Fibre Production the Route for More Sustainable and Cheaper Carbon Fibres?// [[https://www.mdpi.com/2073-4344/13/6/1037]]. 
- 
-Morishita, Y., and et al. 2025. ‘Carbon Fibre Production Using an Ecofriendly Water-Soluble Precursor’. //Nature Communications// 16. [[https://doi.org/10.1038/s41467-025-59841-9]]. 
- 
-Mullin, G., and et al. 1998. Process for the preparation of carbon fiber. issued 1998. [[https://patents.google.com/patent/US5804108A/en]]. 
- 
-Mutel, Chris. 2017. ‘Brightway: An Open Source Framework for Life Cycle Assessment’. //Journal of Open Source Software// 2 (12): 236. [[https://doi.org/10.21105/joss.00236]]. 
- 
-Newcomb, S.L., and et al. 2016. ‘Processing, Structure, and Properties of Carbon Fibers’. //Composites Part A: Applied Science and Manufacturing// 91: 262–82. [[https://doi.org/10.1016/j.compositesa.2016.10.018]]. 
- 
-Paul, Edward L., Victor A. Atiemo-Obeng, and Suzanne M. Kresta, eds. 2004. //Handbook of Industrial Mixing: Science and Practice//. Wiley-Interscience. [[https://doi.org/10.1002/0471451452]]. 
- 
-tdc corpus. 2026. //Harmonizing Life Cycle Assessment Studies of Emerging Technologies: The Case of Virgin and Recycled Carbon Fibers (Notes)//. 
- 
-tdc-calc supply_transport. 2026. //Supply Transport of Purchased Materials (Eurostat Comext 2024 + PEF Legs), RER//. [[https://tool output: tdc-calc supply_transport|tool output: tdc-calc supply_transport]]. 
- 
-===== Annex A — Energy consumption model ===== 
- 
-The tdc energy model computes the heat and electricity demand per functional unit from process physics, in two layers, as process simulators do. 
- 
-**Layer 1 — thermodynamic duties of each step.** Sensible heat //Q// = //m// //c//<sub>//p//</sub> (//T//<sub>out</sub> − //T//<sub>in</sub>); latent heat //Q// = //m// //Δ////H//<sub>phase</sub>; reaction heat //Q// = //ξ// //Δ////H//<sub>//r//</sub> with //ξ// the extent of reaction from the stoichiometry and //Δ////H//<sub>//r//</sub> from a cited value or from formation enthalpies (Hess’s law, atom-balanced); vessel and line losses //U////A////Δ////T////t// or a cited share. Pure-component properties (//c//<sub>//p//</sub>, density, viscosity, //Δ////H//<sub>vap</sub>, //Δ////H//<sub>//f//</sub>) come from cited sources or from the //thermo/chemicals// property library (Bell 2016b), whose correlation is reported with each value. 
- 
-**Layer 2 — conversion of duties into purchased energy.** Heat supply //Q//<sub>purchased</sub> = (//Q//<sub>demand</sub> − //η//<sub>rec</sub>//Q//<sub>exotherm</sub>)///η//<sub>supply</sub>; electricity of each consumer = power × operating time: 
- 
-  * agitation: //P// = //N//<sub>//p//</sub> //ρ// //N//<sup>3</sup>//D//<sup>5</sup>///η//<sub>drive</sub> with //R////e// = //ρ////N////D//<sup>2</sup>///μ// and //N//<sub>//p//</sub>(//R////e//) from the impeller correlations of the //Handbook of Industrial Mixing// (Paul et al. 2004); the batch volume sets the vessel and impeller size; the specific power of the mixing duty (blending 0.1, heat transfer 0.5, solid suspension 0.8, liquid–liquid 1, gas–liquid 2 kW m⁻³) is a lower bound; 
-  * pumps: //P// = //ρ////g////H////V̇///(//η//<sub>pump</sub> //η//<sub>motor</sub>), motor efficiency from premium-efficiency tables (Bell 2016a); 
-  * vacuum: isothermal compression of the vapour/gas load //P// = //ṅ////R////T//ln (//p//<sub>2</sub>///p//<sub>1</sub>)///η// (Bell 2016a); 
-  * cooling: electricity per MJ of heat rejected; installed equipment at part load; plant utilities per tonne, each only with a source. 
- 
-All expressions are unit-checked with //pint//. Result per kg: heat, electricity, primary energy demand (with the primary energy factors of the BAFU energy datasets). Parameters of this dataset: 
- 
-^ Parameter ^ Value ^ Unit ^ Source / assumption ^ 
-| [Fiber stabilization, carbonization, electrolysis and washing] Fiber sensible heat, stabilization (25 to 300 C) (sensible) | {‘m_kg’: 2.7815, ‘cp_kJ_kgK’: 1.5, ‘T_in_C’: 25, ‘T_out_C’: 300} | per kg of step output | Precursor mass 2.7815 kg per kg of core fiber = 2.73704 kg per kg product / 0.984 (Benitez 2021 T700G anchor; stoich spec.json) (stoich element balance, spec.json; harmonizing mass balance precursor 2 | 
-| [Fiber stabilization, carbonization, electrolysis and washing] Stabilization oven air heating (recirculating oxidizer air) (gas_heating) | {‘m_kg’: 156.94, ‘cp_kJ_kgK’: 1.03, ‘T_in_C’: 25, ‘T_out_C’: 250, ‘recovery’: 0.0} | per kg of step output | ‘the air is heated in an electric heater to a predetermined temperature and heats the processed fibers due to convective heat exchange’ (IJAEM2021); electric carrier confirmed by CN102051711B (heating | 
-| [Fiber stabilization, carbonization, electrolysis and washing] Fiber sensible heat, low-temperature carbonization (300 to 1000 C) (sensible) | {‘m_kg’: 2.5, ‘cp_kJ_kgK’: 1.0, ‘T_in_C’: 300, ‘T_out_C’: 1000} | per kg of step output | Stabilized fiber 2.5000 kg per kg core (2.460 kg per kg product / 0.984; harmonizing mass balance: precursor 2.737 -> stabilized 2.460, 10.0% loss, 200-300 C; DATA GAP - sourced IM stage split from th | 
-| [Fiber stabilization, carbonization, electrolysis and washing] Fiber sensible heat, high-temperature carbonization (1000 to 1800 C) (sensible) | {‘m_kg’: 1.25, ‘cp_kJ_kgK’: 1.0, ‘T_in_C’: 1000, ‘T_out_C’: 1800} | per kg of step output | Mid-route fiber (low-T carbonisation product) 1.2500 kg per kg core (1.230 kg per kg product / 0.984; harmonizing mass balance LT carbonisation 50% loss, precursor 2.737. High-temperature carbonisatio | 
-| [Fiber stabilization, carbonization, electrolysis and washing] Carbonisation + surface-treatment stage powers: N2 purge heating, wall losses, electrolysis, drives (sourced RSC stage kW residual) (duty) | {‘MJ’: 29.28} | per kg of step output | RSC_ESI_2016 Table 1 sourced stage powers. | 
-| [Fiber stabilization, carbonization, electrolysis and washing] Stabilization furnace NG burner (on-site gas assist, 0.22 kg NG per kg product) (duty) | {‘MJ’: 6.8035} | per kg of step output | Sourced on-site NG for the stabilization oxidation furnace (carrier fuel). Per user decision 4 the on-site fuel is carried by the energy model as BAFU heat per MJ (fuel_supply boiler module), not as a | 
-| [Fiber stabilization, carbonization, electrolysis and washing] Inert gas make-up compression (N2, slight overpressure of the carbonisation atmospheres) (compressor) | {‘p1_bar’: 1.0, ‘p2_bar’: 1.2, ‘V1_m3_h’: 55.33, ‘gamma’: 1.4, ‘eta’: 0.7} | per kg of step output | All nitrogen purchased externally (JapanCFMA_LCI_2022 sec 5-3-6: ‘All nitrogen was purchased externally’); inert N2 for carbonisation (Prenzel2023). Gas flow 55.33 Nm3/h make-up per kg/h of core (N2 c | 
-| [Fiber stabilization, carbonization, electrolysis and washing] Fiber line tensioner drives, furnace drive trains, electrolysis and washing drives (motor) | {‘P_kW’: 3.04, ‘load’: 1.0, ‘motor_eta’: 0.9} | per kg of step output | Continuous line under constant tension (Prenzel2023 sec 3.1.1) with drive trains per furnace; 3.04 kW per kg/h of core (3 kW per kg/h product / 0.984, line speed 6.5-8.5 m/min, CN102051711B): declared | 
-| [Exhaust gas treatment 1] First off-gas treatment (quench/wash/scrubber) specific energy (specific) | {‘quantity_per_batch’: 1.0, ‘kWh_per_unit’: 0.023} | per kg of step output | First exhaust-gas treatment of the continuous CF line (before the RTO); BAFU dataset ‘Carbon fiber production, exhaust gas treatment 1’ has only an electricity input. | 
-| [Exhaust gas treatment 2 (regenerative thermal oxidizer)] Regenerative thermal oxidizer NG fuel (on-site, 2.06 kg NG per kg product) (duty) | {‘MJ’: 5.9082} | per kg of step output | Sourced on-site RTO fuel (carrier fuel). This plus the step-1 stabilization NG (0.22 kg) = the spec.json stoich NG reactant 2.28 kg per kg product (the on-site fuel combusted in the furnaces/RTO, whos | 
-| [Exhaust gas treatment 2 (regenerative thermal oxidizer)] RTO fans and blower (off-gas and oxidising-air circulation) (specific) | {‘quantity_per_batch’: 1.0, ‘kWh_per_unit’: 0.0262} | per kg of step output | RTO fans and post-treatment blower of the regenerative thermal oxidizer; the sourced RSC_ESI_2016 abatement system (25 kW at 12.5 kg/h) includes these fans - independent check. | 
-| [Fiber drying and sizing] Sizing-bath water heating (technical drying, recovered closed loop) (loss) | {‘MJ’: 1.2} | per kg of step output | The sizing-bath water is a recovered closed loop: ‘the water evaporates in technical drying, is recovered and fed back; the coating remains on the fiber’ (Prenzel2023 sec 3.1.3). 1.2 MJ per kg product | 
-| [Fiber drying and sizing] Drying air handling + winding drives (sourced RSC stage powers) (motor) | {‘P_kW’: 1.08, ‘load’: 1.0, ‘motor_eta’: 0.9} | per kg of step output | RSC_ESI_2016 Table 1 sourced stage powers (measured, 100 t/a pilot line) - independent of the Benitez2021 benchmark. | 
- 
-===== Annex B — Stoichiometry specification and balances ===== 
- 
-<code> 
-{ 
- "product": { 
-  "name": "Carbon fiber, PAN-based, wet spinning, intermediate modulus (IM), sized", 
-  "formula": "C0.079561H0.016013N0.001054O0.000843" 
- }, 
- "inputs": [ 
-  { 
-   "name": "PAN precursor fiber, wet spun", 
-   "mol": 2.73691, 
-   "formula": "C0.056535H0.056548N0.018848", 
-   "io_type": "raw_material", 
-   "in_product": true 
-  }, 
-  { 
-   "name": "Sizing agent, epoxy", 
-   "mol": 0.016, 
-   "formula": "C0.057069H0.085605O0.014267", 
-   "io_type": "raw_material", 
-   "in_product": true 
-  }, 
-  { 
-   "name": "Oxygen, resource in air", 
-   "mol": 3.5406349670329504, 
-   "formula": "O0.062504", 
-   "io_type": "resource", 
-   "in_product": true 
-  }, 
-  { 
-   "name": "Nitrogen, liquid, at plant", 
-   "mol": 8.822, 
-   "formula": "N0.071393", 
-   "io_type": "resource", 
-   "in_product": true 
-  }, 
-  { 
-   "name": "Ammonium bicarbonate, at plant", 
-   "mol": 0.01842, 
-   "formula": "N0.012649H0.063246C0.012649O0.037948", 
-   "io_type": "resource", 
-   "in_product": false 
-  }, 
-  { 
-   "name": "Ethylene glycol, at plant", 
-   "mol": 0.0076, 
-   "formula": "C0.032223H0.096668O0.032223", 
-   "io_type": "resource", 
-   "in_product": false 
-  } 
- ], 
- "outputs": [ 
-  { 
-   "name": "Carbon dioxide, fossil (to air)", 
-   "mol": 3.318461538461536, 
-   "formula": "C0.022722O0.045447", 
-   "io_type": "emission" 
-  }, 
-  { 
-   "name": "Water, off-gas vapor (to air)", 
-   "mol": 1.2526964285714288, 
-   "formula": "H0.111019O0.055513", 
-   "io_type": "emission" 
-  }, 
-  { 
-   "name": "Nitrogen, off-gas (to air)", 
-   "mol": 9.527627999999998, 
-   "formula": "N0.071393", 
-   "io_type": "emission" 
-  }, 
-  { 
-   "name": "Nitrogen oxides, fossil (to air)", 
-   "mol": 0.00012, 
-   "formula": "N0.033327O0.033327", 
-   "io_type": "emission" 
-  }, 
-  { 
-   "name": "Hydrogen cyanide (to air)", 
-   "mol": 0.00191, 
-   "formula": "C0.036999H0.036999N0.036999", 
-   "io_type": "emission" 
-  }, 
-  { 
-   "name": "Carbon monoxide, fossil (to air)", 
-   "mol": 0.009236, 
-   "formula": "C0.035702O0.035702", 
-   "io_type": "emission" 
-  }, 
-  { 
-   "name": "Ammonia (to air)", 
-   "mol": 0.001357, 
-   "formula": "N0.058716H0.176149", 
-   "io_type": "emission" 
-  }, 
-  { 
-   "name": "Methane (to air)", 
-   "mol": 0.001717, 
-   "formula": "C0.052431H0.209724", 
-   "io_type": "emission" 
-  }, 
-  { 
-   "name": "Ethylene (to air)", 
-   "mol": 0.001711, 
-   "formula": "C0.056908H0.113815", 
-   "io_type": "emission" 
-  }, 
-  { 
-   "name": "Ethane (to air)", 
-   "mol": 0.001714, 
-   "formula": "C0.054638H0.109275", 
-   "io_type": "emission" 
-  } 
- ] 
-} 
-</code> 
- 
-===== Annex C — Transport calculation (raw-material provenance) ===== 
- 
-Provenance of each raw material in the supply of the region: supply_transport (Eurostat Comext / UN Comtrade provenance shares, PEF legs). Legs: default scenario of the PEF method (Commission Recommendation (EU) 2021/2279 of 15 December 2021 on the Use of the Environmental Footprint Methods to Measure and Communicate the Life Cycle Environmental Performance of Products and Organisations 2021) (European suppliers 130 km truck, 240 km train, 270 km barge; overseas suppliers 1000 km truck plus the sea route from the origin’s main port, computed on the marine network). 
- 
-^ Raw material ^ HS code ^ Regional share ^ Overseas share ^ Main partners ^ Mean sea distance (km) ^ Source ^ 
- 
-===== Annex D — Source excerpts ===== 
- 
-Every value taken from a source, with the verbatim passage it relies on (also attached as notes to the references in the Zotero library). 
- 
-^ Reference ^ Page / section ^ Excerpt ^ Used for ^ 
-| (tdc corpus 2026) | Mass Balance Summary | “PAN -> Stabilized 2.78 2.503 10.0%. Stabilized -> LT Carb 2.503 1.252 50.0%. LT Carb -> HT Carb 1.252 0.984 21.4%. HT Carb -> CF 0.984 1.0 (sizing added).” | precursor->fiber mass yield: precursor 2.78 kg per 1 kg sized CF; stabilization 10.0% loss, LT carbonization 50.0% loss, HT carbonization 21.4% loss; sizing adds 0.016 kg | 
-| (tdc corpus 2026) | Energy Inputs | “Stabilization 18.82. Carbonization LT 4.17. Carbonization HT 8.06. Electrolysis 0.21. Final washing/drying/sizing ~1.2. TOTAL ~43.4 kWh/kg CF.” | electricity split for the conversion steps (per 1 kg CF): stabilization 18.82, LT 4.17, HT 8.06, electrolysis 0.21, final washing/drying/sizing 1.2; precursor-side ~19.4 kWh excluded (in precursor dataset) | 
-| (tdc corpus 2026) | Natural Gas | “Natural Gas: Stabilization 0.22 kg/kg CF (0.34 m3). Exhaust treatment 2 2.06 kg/kg CF (0.29 m3).” | natural gas for stabilization heating + exhaust-gas abatement: 0.22 + 2.06 = 2.28 kg per 1 kg CF | 
-| (tdc corpus 2026) | Key Emissions | “HCN 2.35 Stabilization + Carbonization. CO 0.56 Stabilization + Carbonization. NH3 0.22 Stabilization + Carbonization. N2 ~70 Various (inert gas releases). H2O (vapor) ~12 Drying stages. CH4 0.014 Carbonization.” | air emissions per 1 kg CF from stabilization+carbonization (before abatement): HCN 2.35 kg, CO 0.56 kg, NH3 0.22 kg, N2 ~70 kg, H2O ~12 kg, CH4 0.014 kg; full-chain value, precursor-side share assigned to precursor dataset | 
-| (tdc corpus 2026) | Key Material Inputs | “Nitrogen (liquid) 8.96 kg. Ethylene glycol 0.01 kg. Epoxy resin (sizing) 0.01 kg. Industrial water 48.0 kg. Deionized water 3.1 kg. Compressed air 1.46 Nm3.” | process water make-up ~48 kg, deionized 3.1 kg, nitrogen liquid 8.96 kg (full chain; conversion share estimated), compressed air 1.46 Nm3, sizing 0.01 kg (full chain; BAFU T700G uses 0.0102 kg) | 
-| (Dér, A. and et al. 2021) | Table 2 + total line energy | “Altogether, the energy intensity of the investigated carbon fibre line amounts to 1150.5 MJ/kg carbon fibre. The high energy demand of the abatement system that uses natural gas is reflected in the breakdown of the total energy demand.” | independent total energy intensity of a full CF line 1150.5 MJ/kg CF (incl. precursor + abatement with natural gas) for cross-check of energy order of magnitude | 
-| (Newcomb, S.L. and et al. 2016) | Section 2.1.3 | “Traditional stabilization processes utilize the heat treatment of the fiber in an oxidative environment at temperatures ranging from about 200 C to 300 C while the filaments are subjected to an applied tension.” | stabilization temperature 200-300 C in air, under tension | 
-| (Newcomb, S.L. and et al. 2016) | Section 2.1.3 | “The stabilized fibers are then carbonized at a temperature range between 700 and 3000 C in an inert atmosphere. The carbonization temperature determines the final structure” | carbonization in inert atmosphere 700-3000 C; IM grade processed up to ~1500 C | 
-| (Morishita, Y. and et al. 2025) | Table R4 | “PAN: C 67.9 wt%, H 5.7 wt%, N 26.4 wt%, O 0.0 wt%, P 0.0 wt%.” | composition of the dried wet-spun PAN precursor fiber used in spec.json (elemental pseudo-formula) | 
-| (Morishita, Y. and et al. 2025) | Fig 1c discussion | “Energy consumption of the stabilisation process accounts for ~57% of the total energy consumption, which reflects the long heat treatment time (typically 200-300 C, 60-90 min).” | stabilization dominates energy; typical duration 60-90 min at 200-300 C | 
-| (Khayyam, H. and et al. 2021) | Section 4 | “The exhausts gases from the stabilization process such as CO, CO2, and HCN must be burnt in an abatement system to eliminate the emission of toxic fumes into the atmosphere. The burning process requires a temperature of about 850 C.” | off-gas treatment: thermal oxidizer at ~850 C burns CO/CO2/HCN off-gas (destruction of HCN/CO modelled in spec.json reactions) | 
-| (Lenter, E. and et al. 2023) | LCA section | “An example of intermediate modulus carbon fibres with a Young’s modulus of 277 GPa and a tensile strength of 4300 MPa is presented, where oxidative stabilisation, carbonisation and surface treatment consume 81.4 MJ, 216.1 MJ and 4.6 MJ, respectively.” | independent IM-grade process: stabilization 81.4 MJ, carbonization 216.1 MJ, surface treatment 4.6 MJ per 1 kg unsized CF (cross-check energy literature value) | 
-| (Lenter, E. and et al. 2023) | sizing section | “Typically, the amount of sizing applied to the fibres is only in the magnitude of 0.8-2.0 wt% of the sized fibres.” | sizing content 0.8-2.0 wt% of sized fiber -> 0.016 kg sizing per 1 kg sized CF (central 1.6 wt%, matches harmonizing notes 0.016/0.984) | 
-| (Mullin, G. and et al. 1998) | 0013 | “The oxidation step is conducted in an oxidizing atmosphere, usually air, at a temperature of about 190 C. to about 280 C.” | stabilization in air at 190-280 C (independent patent confirmation of Newcomb 200-300 C) | 
-| (Mullin, G. and et al. 1998) | 0014 | “The carbonization step which follows the oxidation step is performed rapidly in an inert atmosphere at a temperature of about 1000 C. to about 2000 C.” | carbonization in inert atmosphere 1000-2000 C; IM grade within range (final ~1500 C) | 
-| (tdc corpus 2026) | Energy Inputs | “Energy Inputs (per kg CF): Electricity Stage kWh/kg CF. … Stabilization 18.82. Carbonization LT 4.17. Carbonization HT 8.06. Electrolysis 0.21. Final washing/drying/sizing ~1.2. TOTAL ~43.4 kWh/kg CF.” | in-scope electricity 33.65 kWh/kg = stabilization 18.82 + carbonization LT/HT 12.23 + EGT 1.15 + electrolysis/washing/sizing 1.41 + cooling 0.04 (precursor-side steps excluded, in the precursor dataset) | 
-| (tdc corpus 2026) | Heat (Steam) / Natural Gas | “Heat (Steam) Stage kg steam/kg CF. … Carbonization LT 1.86. TOTAL ~12.7 kg/kg CF. Natural Gas: Stabilization 0.22 kg/kg CF. Exhaust treatment 2 2.06 kg/kg CF. Energy Conversion: Steam ~2.7 MJ/kg.” | heat exchange 56.5 MJ/kg = EGT NG 2.06 kg x 22.8 MJ/kg + carbonization steam 1.86 kg x 2.7 MJ/kg, net of furnace efficiency 0.92 | 
-| (Newcomb, S.L. and et al. 2016) | Chapter 4 (processing) | “Traditional stabilization processes utilize the heat treatment of the fiber in an oxidative environment at temperatures ranging from about 200 C to 300 C while the filaments are subjected to an applied tension.” | stabilization in air/oxidative atmosphere at 200-300 C with applied tension; carbonization then 700-3000 C inert; IM grade carbonized to ~1500 C | 
-| (Hao X, Li R, Wang J, Yang X 2018) | Abstract | “The VOCs removal rate in this study was constantly above 98%, and the average thermal efficiency reached 90%.” | off-gas (EGT) destruction efficiency: two regenerative-oxidizer stages, each >98% VOC removal (Hao 2018) -> overall ~99.96% used as 99% DRE; toxic residuals <10 g/kg | 
-| (BAFU (graph) 2026) | BAFU dataset ‘fiber stabilization, carbonization, electrolysis and washing’ | “Nitrogen, liquid, at plant 8.079 kg; Tap water, at user 0.6109 kg; Natural gas, from medium pressure network (0.1-1 bar), at service station 0.1983 kg; Steam, for chemical processes, at plant 1.674 kg; Ammonium bicarbonate, at plant 0.01842 kg; Ethylene glycol, at plant 0.0076335 kg” | sourced in-scope resource inputs: N2 8.079 kg, tap water 0.61 kg, NG 0.1983 kg, steam 1.674 kg, NH4HCO3 0.01842 kg, EG 0.0076 kg per kg CF | 
-| (BAFU (graph) 2026) | BAFU dataset ‘exhaust gas treatment 2’ | “Natural gas, from medium pressure network (0.1-1 bar), at service station 0.1908 kg; Nitrogen oxides 0.009991 kg to air; Carbon dioxide, fossil 0.702 kg; Water 0.474 kg; Nitrogen 3.441 kg.” | off-gas treated by thermal oxidation: NG 0.1908 kg support fuel, CO2 0.702 + H2O 0.474 + N2 3.441 kg combustion products, NOx 0.00999 kg residual per kg CF (BAFU EGT2) -> supports post-EGT off-gas composition | 
-| (tdc-calc supply_transport 2026) | Result | “The ship leg (6.63 tkm) is driven by the extra-EU import shares of ammonium bicarbonate (57.4% extra-EU, CN 47.7%) and nitrogen (5.5% extra-EU); BAFU T700G analog datasets carry a smaller single-mode lorry/rail allocation, so the total tkm here is higher than those datasets.” | transport crosscheck deviation: PEF/Eurostat multi-mode tkm (11.99) vs BAFU T700G single-mode allocation (1.26) | 
-| (tdc corpus 2026) | Natural Gas | “Natural Gas: Stabilization 0.22 kg/kg CF (0.34 m3). Exhaust treatment 2 2.06 kg/kg CF (0.29 m3).” | natural gas input 2.28 kg/kg CF (stabilization 0.22 + EGT 2.06) -> 51.98 MJ; CO2 9.69 kg off-gas includes EGT combustion; corrected after second-model review | 
-| (tdc corpus 2026) | Mass Balance Summary | “PAN -> Stabilized 2.78 2.503 10.0%. Stabilized -> LT Carb 2.503 1.252 50.0%. LT Carb -> HT Carb 1.252 0.984 21.4%. HT Carb -> CF 0.984 1.0 (sizing added).” | precursor->fiber mass balance: 2.78 kg PAN precursor per 1 kg sized CF; mass loss increases at each heat-treatment stage (10%, 50%, 21.4%) so higher grades (more HT) need at least as much precursor | 
-| [Benitez2021] | see RER snippet | “Per-step LCI inventory (workbook lci-carbon-fiber.xlsx) of Toray T700G PAN-based carbon fibre production, based on Ellringmann 2016, Gill 2016, Muetzel 2012. The carbon-fibre heat-treatment chain is split into per-sub-process inventories (per kg of each sub-process’s own output).” | shared with sibling cf-v2-im-rer (grade/region-independent energy references) | 
-| [RSC_ESI_2016] | see RER snippet | “The energy consumption of our 100 tons per year pilot line displayed on Figure 1 was measured by the Carbon Nexus production facility” | shared with sibling cf-v2-im-rer (grade/region-independent energy references) | 
-| [Prenzel2023] | see RER snippet | “a plausible average value for the total energy demand for the production of 12 k and 24 k HT-fibers was determined to be 170 MJ of thermal and electric per kg carbon fiber” | shared with sibling cf-v2-im-rer (grade/region-independent energy references) | 
-| (tdc corpus 2026) | see RER snippet | “PAN -> Stabilized 2.78 2.503 10.0%. Stabilized -> LT Carb 2.503 1.252 50.0%. LT Carb -> HT Carb 1.252 0.984 21.4%. HT Carb -> CF 0.984 1.0 (sizing added).” | shared with sibling cf-v2-im-rer (grade/region-independent energy references) | 
-| [supply_transport_ras_2024] | supply_transport detail, region=RAS | “Result (tkm per kg product): lorry 1.263426 -> BAFU ‘Transport, freight, lorry, diesel, 40t gross weight, 2006, EURO-IV, long haul’ rail 2.094619 -> BAFU ‘Transport, freight, rail’ barge 2.356446 -> BAFU ‘Transport, barge’ ship 2.311251 -> BAFU ‘Transport, transoceanic freight ship’ Total 8.03 tkm. Provenance detail: UN Comtrade public API, imports by partner of 156, 392, 410” | supply transport tkm per kg product (N2 carrier 8.822 kg Benitez 2021, UN Comtrade RAS 2024, no N2 domestic_share): total 8.03 tkm | 
- 
-===== Annex E — Independent second-model review ===== 
- 
-^ # ^ Severity ^ Exchange ^ Finding ^ Answer / change ^ 
-| 1 | medium | Methane (to air) | The amount in exchanges (0.001444 kg) does not match the amount in spec.json (0.001717 kg). | Not an error. spec.json ‘mol’ fields are the RAW input estimates fed to the deterministic stoich tool; the posted exchanges are the tool’s balance-closed amounts. Re-running ‘stoich spec.json’ today (no post) reproduces the LCI amounts EXACTLY (CH4 0.001444, C2H4 0.001366, C2H6 0.001314 kg/kg CF) wi | 
-| 2 | medium | Ethylene (to air) | The amount in exchanges (0.001366 kg) does not match the amount in spec.json (0.001711 kg). | Not an error. The LCI amount 0.001366 kg/kg CF is the deterministic stoich tool’s balance-closed output, not the raw spec input: re-running ‘stoich spec.json’ on the current spec (verified today, no post) reproduces the LCI value exactly and closes all element balances (C -0.0 %, H -0.001 %, N 0.0 % | 
-| 3 | medium | Ethane (to air) | The amount in exchanges (0.001314 kg) does not match the amount in spec.json (0.001714 kg). | Not an error. Same mechanism as findings 1-2: the LCI amount 0.001314 kg/kg CF is the deterministic stoich tool’s balance-closed output for the current spec.json (re-run verified today: reproduces the LCI values exactly, C/H/N/O/mass residuals within 0.001 %, pass=true; board stoich-stage evidence m | 
-| 4 | low | Carbon monoxide, fossil (to air) | Pedigree score for Carbon monoxide (reliability 4) is inconsistent with the ‘why’ reason which cites a 99% DRE (destruction removal efficiency) from a source (Hao 2018), which is a technology/literature-based estimate rather than pure stoichiometry. |  | 
- 
-===== Annex F — Cross-check with independent data ===== 
- 
-Independent analogs (BAFU): [‘Carbon fiber production, fiber stabilization, carbonization, electrolysis and washing’, ‘Carbon fiber production, exhaust gas treatment 2’, ‘Carbon fiber production, fiber drying and sizing’]; tolerance: factor 3.0 
- 
-^ exchange / class ^ this dataset (per kg) ^ independent value(s) ^ source ^ status ^ 
-| electricity | 28.8 | 0.02621 - 28.23 | Carbon fiber production, fiber stabilization, carbonization, electrolysis and washing, Carbon fiber production, exhaust gas treatment 2, Carbon fiber production, fiber drying and sizing | ok | 
-| transport | 8.026 | 0.007105 - 1.26 | Carbon fiber production, fiber stabilization, carbonization, electrolysis and washing, Carbon fiber production, exhaust gas treatment 2, Carbon fiber production, fiber drying and sizing | FLAG | 
-| water | 8.114e-05 | 8.114e-05 - 0.0002505 | Carbon fiber production, fiber stabilization, carbonization, electrolysis and washing, Carbon fiber production, fiber drying and sizing | ok | 
-| Tap water, at user | 0.61 | 0.6109 kg | BAFU ’Carbon fiber production, fiber stabilization, carboniz | ok | 
-| Water, deionised, at plant | 8.114e-05 | 8.114e-05 kg | BAFU ’Carbon fiber production, fiber stabilization, carboniz | ok | 
-| Electricity, medium voltage, production RAS, at grid | 28.796493 | 47.2 kWh | Prenzel2023 sec 4.3 whole-process 170 MJ per kg CF (thermal+ | ok | 
-| Heat, natural gas, at heat plant | 69.380646 | 69.380646 MJ | tdc energy model v3.1 (energy.json) fuel_heat per_kg_product | ok | 
-| electricity vs energy.json | 28.8 | 28.8 kWh | tdc energy model | ok | 
- 
-=== 8.0.1 Justified deviations (with evidence) === 
- 
-  * transport: PEF/UN-Comtrade multi-mode supply transport of purchased materials with the Benitez-2021 N2 carrier 8.822 kg/kg (lorry 1.263 + rail 2.095 + barge 2.356 + ship 2.311 = 8.03 tkm). Ship leg driven by RAS import shares, UN Comtrade 2024 hub Shanghai: epoxy 30.3% overseas (TW/KR/JP), NH4HCO3 100% regional (CN/JP), N2 1.4% overseas (98.6% regional CN; no domestic_share applied, N2 is air-separated regionally). vs BAFU T700G single-mode lorry/rail allocation; mandated by PEF default legs + UN Comtrade provenance [evidence: supply_transport_ras_2024] 
-  * energy-divergence Exhaust gas treatment 2 (regenerative thermal oxidizer): RTO fan electricity 0.0262 kWh per kg off-gas vs the RSC_ESI_2016 independent value 0.1885 (x0.139): the RSC figure is the WHOLE abatement train of the 100 t/a pilot line (first treatment + RTO + post-treatment, ‘Abatement system 25 kW’) divided by this step’s off-gas only, so it overstates the RTO’s own blower duty; the model’s full abatement electricity (EGT1 0.834 + EGT2 0.278 = 1.112 kWh per kg CF) is x1.80 of the measured whole-train 2.0 kWh per kg CF - the two sources agree on the train, and the RTO’s own step-specific fan value is the sourced 0.0262 kWh per kg off-gas (Benitez 2021 EGT2). The step’s heat now matches the Benitez benchmark within 0.3% on the shared 10.61 kg off-gas basis. [evidence: RSC_ESI_2016] 
-  * energy-divergence Fiber drying and sizing: The model heat_MJ = 0 vs the Benitez benchmark 0.335 MJ steam: the sizing-bath water heating and the drying-air/winding drives are ELECTRICALLY heated in this line (closed-loop recovered sizing water, sizing bath, CN102051711B; sourced RSC stage kW 5 kW material handling + 10 kW winding), so the thermal load sits in electricity (1.592 kWh per kg product, x2.55 of the benchmark 0.626 kWh - both within factor 3) rather than as a steam utility. Only the heat-vs-steam FORM differs because of the carrier choice, not the total: total_MJ 5.73 vs 2.59 benchmark (x2.21) and vs the sourced RSC measured 4.32 MJ (x1.33), both within factor 3. [evidence: RSC_ESI_2016] 
-  * family-trend: IM precursor 2.73704 kg per kg sized CF = the Benitez 2021 T700G (intermediate-modulus) LCI mass balance, ‘fiber winding and unwinding’ sub-process kg_per_kg_product (doi:10.1016/j.jclepro.2020.123277), the same anchor as the cf-v2-sm-ras reference (2.73682): IM >= SM holds, and the grade order SM <= IM <= HM <= UHM is preserved (HM/UHM add graphitisation mass loss on top of this anchor, per their sourced stepwise balances). Off-gas N2 carrier 8.822 kg/kg (Benitez combined sub-process) replaces the old 8.079 kg; no on-site NG in the stoich (decision 4: fuel as BAFU heat per MJ in the energy model). [evidence: Benitez2021] 
- 
-Open flags: none 
- 
-===== Annex G — Files, tools and audit trail ===== 
- 
-^ Item ^ File / tool ^ Version / date ^ 
-| spec.json | /home/achile/tdc_datasets/cf-v2-im-ras/spec.json | 2026-10-27 | 
-| energy.json | /home/achile/tdc_datasets/cf-v2-im-ras/energy.json | 2026-10-27 | 
-| energy_result.json | /home/achile/tdc_datasets/cf-v2-im-ras/energy_result.json | 2026-10-27 | 
-| snippets.json | /home/achile/tdc_datasets/cf-v2-im-ras/snippets.json | 2026-10-27 | 
-| board.json | /home/achile/tdc_datasets/cf-v2-im-ras/board.json | 2026-10-27 | 
-| review.json | /home/achile/tdc_datasets/cf-v2-im-ras/review.json | 2026-10-28 | 
-| lcia.json | /home/achile/tdc_datasets/cf-v2-im-ras/lcia.json | 2026-10-28 | 
-| cf-v2-im-ras.ecospold | /home/achile/tdc_datasets/cf-v2-im-ras/cf-v2-im-ras.ecospold | 2026-10-27 | 
-| tdc-doc | /home/achile/tdc/scripts/tdc_doc.py | 2026-10-28 | 
- 
-===== Annex H — BAFU DQR v2.1 documentation fields (EcoSpold v1 metadata) ===== 
- 
-^ DQR field ^ Content ^ 
-| name | Carbon fiber, PAN-based, wet spinning, IM, RAS | 
-| location | RAS | 
-| unit | kg | 
-| time period | 2020-2025, reference year 2024 | 
-| geography | Asia | 
-| technology | Conversion of 1 kg of wet-spun PAN precursor fiber into 1 kg of sized, intermediate modulus (IM) carbon fiber: stabilization (oxidation in air), low- and high-temperature carbonisation, surface treatment, sizing and drying, with exhaust-gas treatment and plant utilities. The PAN precursor fiber itse | 
-| included processes | Fiber stabilization, carbonization, electrolysis and washing; Exhaust gas treatment 1; Exhaust gas treatment 2 (regenerative thermal oxidizer); Fiber drying and sizing | 
-| representativeness | Section 3 | 
-| sources | 15 references (Annex D, References) | 
-| data generator | tdc pipeline | 
-| validation | tdc-doc final control: ready for external review | 
- 
----- 
- 
-To comment on this report, select a passage and use the annotation panel on the right (registered users; comments are published once the BAFUquery team has reviewed them). To suggest a dataset that does not exist yet, use [[proposals:start|Propose a dataset]]. 
  
datasets/tdc/c724fe59-4f68-5735-a13e-4edb0d44388d.1794866394.txt.gz · Last modified: by 127.0.0.1

Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki