OpenData Wiki

Dataset documentation and review before publication

User Tools

Site Tools


datasets:bafu:041e12fb-6361-40ef-9a9f-5e383f3dae12

Disposal, ventilation system, Pflegezentrum Witikon — CH

Dataset documentation and final control (tdc-doc, imported mode)
Open this dataset in OpenData

Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Disposal, ventilation system, Pflegezentrum Witikon [CH], per 1 p. EF v3.1 climate change 1.033e+04 kg CO2 eq (Monte Carlo 95 % interval 9363–1.261e+04). Main contributors: Disposal, ventilation unit 13000 m3/h, w. circuit connected … 38 %; Disposal, thermal insulation, 30mm, 40kg/m3, reinforced alum… 7 %; Disposal, EI 30 fire insulation, 50mm, 120kg/m3, reinforced … 7 %; Disposal, ventilation duct, steel, zinc coated, s= 0.75mm 5 %; Disposal, silencer for ventilator unit 13000 m3/h, modular 5 %; Disposal, ventilation duct, steel, zinc coated, s= 0.62mm 5 %. Status: final control passed.
Item Value
Dataset name Disposal, ventilation system, Pflegezentrum Witikon
Dataset UUID / graph id 041e12fb-6361-40ef-9a9f-5e383f3dae12 / activity:disposal_ventilation_system_pflegezentrum_witikon__ch
Reference product, unit Disposal, ventilation system, Pflegezentrum Witikon, 1 p
Location CH — Specific to the technology mix encountered in sorting plants in Switzerland.
Time period 2014-01/2014-12
Category waste management / building demolition
Source database BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1
Publisher Swiss Federal Office for the Environment (FOEN/BAFU)
Background database BAFU 2026 v1 (graph bafuquery-db)
LCIA method EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix)
Status final control passed
Documented by tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17

Introduction

Disposal of a ventilation system for a residential care home with apartments, kitchen, cafe/restaurant, multi-purpose hall, laundry and car park. The inventory is based on a building with a total heated gross floor area of 11358 m2 and a total nominal air flow of 74580 m3/h, total weight of the components: 30520 kg/Unit, building with a specific air flow rate of 6.6 m3/h per m2 heated gross floor area. Data from call of bid including components for air handling units, ducts including insulation, air valves, roof-hoods, dampers, fire dampers, silencers. The data represent a ductwork mainly made of galvanized steel and includes air handling units mainly with heat recovery. System with central air handling units. Building without ground heat exchanger.; UUID: 041e12fb-6361-40ef-9a9f-5e383f3dae12

This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.

Goal and scope

Function, functional unit and reference flow

Reference flow: 1 p of Disposal, ventilation system, Pflegezentrum Witikon (CH). All results are given per unit of the reference flow.

System boundary

Transport to dismantling facilities, machines for handling in sorting plant, electricity demand for sorting plant, final disposal of waste material. Cut-off to recycling for metals.

Technology

Disposal to a sorting plant assumed. Metal pieces, copper in cables and electronic devices are recycled, plastic parts are incinerated, inert wastes (e.g. rock wool) are landfilled.

Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).

LCIA method

EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.

Life cycle inventory

Inventory table

Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).

Exchange Type Location / compartment Amount Unit Uncertainty Pedigree GWP share (%) Notes
Disposal, ventilation unit 13000 m3/h, w. circuit connected heat exchanger technosphere CH 4.635 p lognormal, GSD² 1.26 (3,4,1,1,1,5) 37.6 ████████
Disposal, thermal insulation, 30mm, 40kg/m3, reinforced alumium foil technosphere CH 4730 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 7.4 █
Disposal, EI 30 fire insulation, 50mm, 120kg/m3, reinforced alumium foil technosphere CH 2735 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 6.6 █
Disposal, ventilation duct, steel, zinc coated, s= 0.75mm technosphere CH 2870.5 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 5.1 █
Disposal, silencer for ventilator unit 13000 m3/h, modular technosphere CH 20.54 p lognormal, GSD² 1.26 (3,4,1,1,1,5) 5.0 █
Disposal, ventilation duct, steel, zinc coated, s= 0.62mm technosphere CH 2832.2 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 4.9 █
Disposal, ventilation unit 6700 m3/h, w. circuit connected heat exchanger technosphere CH 1 p lognormal, GSD² 1.26 (3,4,1,1,1,5) 4.8 █
Disposal, ventilator unit 13000 m3/h, modular, w. filter, without silencer technosphere CH 1 p lognormal, GSD² 1.26 (3,4,1,1,1,5) 3.5 █
Disposal, ventilation unit 3500 m3/h, w. cross plate heat excanger technosphere CH 0.977 p lognormal, GSD² 1.26 (3,4,1,1,1,5) 2.8 █
Disposal, spiral-seam duct, steel, zinc coated, s= 0.5mm technosphere CH 868.65 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 2.8 █
Disposal, ventilation duct, steel, zinc coated, s= 0.87mm technosphere CH 1446.4 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 2.6 █
Disposal, ventilation unit 1800 m3/h, w. cross plate heat excanger technosphere CH 1.378 p lognormal, GSD² 1.26 (3,4,1,1,1,5) 2.5 ·
Disposal, ventilation system, Pflegezentrum Witikon, various components technosphere CH 1 p lognormal, GSD² 1.24 (2,4,1,1,1,5) 2.1 ·
Disposal, ventilation unit 3500 m3/h, w. circuit connected heat exchanger technosphere CH 0.717 p lognormal, GSD² 1.26 (3,4,1,1,1,5) 2.0 ·
Disposal, ventilator unit 3500 m3/h, modular, w. filter, without silencer technosphere CH 1.694 p lognormal, GSD² 1.26 (3,4,1,1,1,5) 1.9 ·
Disposal, EI 60 fire insulation, 70mm, 120kg/m3, reinforced alumium foil technosphere CH 485 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 1.4 ·
Disposal, silencer for ventilator unit 3500 m3/h, modular technosphere CH 10.164 p lognormal, GSD² 1.26 (3,4,1,1,1,5) 1.3 ·
Disposal, ventilation duct, steel, zinc coated, s= 1.0mm technosphere CH 667.21 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 1.2 ·
Disposal, ventilation duct, steel, zinc coated, s= 1.5mm technosphere CH 379.07 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 0.8 ·
Disposal, silencer for ventilator unit 6700 m3/h, modular, Device technosphere CH 4 p lognormal, GSD² 1.26 (3,4,1,1,1,5) 0.7 ·
Disposal, ventilation duct, steel, zinc coated, s= 1.25mm technosphere CH 331.1 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 0.6 ·
Disposal, thermal insulation, 100mm, 40kg/m3, alumium cladding technosphere CH 735 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 0.6 ·
Disposal, silencer for ventilator unit 1800 m3/h, modular, Device technosphere CH 5.512 p lognormal, GSD² 1.26 (3,4,1,1,1,5) 0.5 ·
Disposal, thermal insulation, 100mm, 40kg/m3, reinforced alumium foil technosphere CH 174 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 0.4 ·
Disposal, ventilation duct, stainless steel, s= 1.25mm technosphere CH 155.14 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 0.3 ·
Disposal, ventilation duct, stainless steel, s= 1.0mm technosphere CH 119 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 0.2 ·
Disposal, ventilation system, Pflegezentrum Witikon, special components technosphere CH 1 p lognormal, GSD² 1.24 (2,4,1,1,1,5) 0.2 ·
Disposal, ventilation duct, stainless steel, s= 1.5mm technosphere CH 66.6 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 0.1 ·
Disposal, ventilation duct, stainless steel, s= 0.87mm technosphere CH 61 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 0.1 ·
Disposal, ventilation duct, stainless steel, s= 0.62mm technosphere CH 30 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 0.1 ·
Disposal, spiral-seam duct, steel, zinc coated, s= 0.6mm technosphere CH 6.0781 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 0.0 ·
Disposal, ventilation duct, stainless steel, s= 0.75mm technosphere CH 10.6 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 0.0 ·

Data quality

32 of 32 direct exchanges carry a declared pedigree, 32 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 2.34 · completeness 4.0 · temporal 1.0 · geographical 1.0 · technological 1.0 · sample size 5.0.

Field As declared by the publisher
Data generator / entry / validation data generator: Alex Primas (HSLU); data entry: Alex Primas (HSLU); validation (proof reading): Alex Primas (HSLU)
extrapolations none
sampling procedure Waste-specific calculation based on production input data
production volume na
uncertainty adjustments none
time period comment Amount of material investigated in 2013. Disposal technology mix as used in late 1990ies

Data gaps, proxies and assumptions

None recorded.

Life cycle impact assessment (EF v3.1)

Per 1 p. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.

Impact category Indicator Unit Result 2.5 % 97.5 % GSD²
Acidification Accumulated Exceedance (AE) mol H+ eq 3.287 2.975 6.68 1.51
Climate change-Biogenic Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 2.219 1.777 4.371 1.58
Climate change-Fossil Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 1.033e+04 9360 1.261e+04 1.17
Climate change-Land use and land use change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.4064 0.3552 0.6264 1.33
Climate change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 1.033e+04 9363 1.261e+04 1.17
EF-particulate Matter Impact on human health disease incidence 3.077e-04 1.960e-04 6.468e-04 1.81
Ecotoxicity, freshwater_inorganics Comparative Toxic Unit for ecosystems (CTUe) CTUe 4.263e+04 3.354e+04 6.923e+04 1.46
Ecotoxicity, freshwater_organics Comparative Toxic Unit for ecosystems (CTUe) CTUe 183.7 161.9 340.5 1.49
Ecotoxicity, freshwater Comparative Toxic Unit for ecosystems (CTUe) CTUe 4.281e+04 3.373e+04 6.946e+04 1.46
Eutrophication marine Fraction of nutrients reaching marine end compartment (N) kg N eq 3.817 3.084 8.643 1.69
Eutrophication, freshwater Fraction of nutrients reaching freshwater end compartment (P) kg P eq 2.428 0.3449 66.79 16.6
Eutrophication, terrestrial Accumulated Exceedance (AE) mol N eq 26.97 21.1 66.63 1.8
Human toxicity, cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 5.194e-07 5.198e-07 2.049e-06 2.01
Human toxicity, cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 2.674e-07 2.302e-07 4.124e-07 1.35
Human toxicity, cancer Comparative Toxic Unit for human (CTUh) CTUh 7.867e-07 8.032e-07 2.387e-06 1.73
Human toxicity, non-cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 3.165e-05 3.078e-05 1.157e-04 1.95
Human toxicity, non-cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 2.231e-06 1.761e-06 3.475e-06 1.42
Human toxicity, non-cancer Comparative Toxic Unit for human (CTUh) CTUh 3.388e-05 3.310e-05 1.184e-04 1.9
Ionising radiation, human health Human exposure efficiency relative to U235 kBq U235 eq 365.3 140.2 2227 4.14
Land use Soil quality index pt (soil quality index) 1.623e+04 -3820 4.254e+04 —
Ozone depletion Ozone Depletion Potential (ODP) kg CFC-11 eq 4.337e-05 3.968e-05 7.124e-05 1.34
Photochemical ozone formation - human health Tropospheric ozone concentration increase kg NMVOC eq 10.54 8.649 23.79 1.64
Resource use, fossils Abiotic resource depletion fossil fuels (ADP-fossil) MJ 1.98e+04 1.831e+04 3.203e+04 1.33
Resource use, minerals and metals Abiotic resource depletion (ADP ultimate reserve) kg Sb eq 0.002561 0.002201 0.005069 1.52
Water use User deprivation potential (deprivation-weighted water consumption) m3 world eq deprived 1401 -1.589e+05 8.474e+04 —

Climate change 1.033e+04 kg CO2 eq per p. Main contributors: Disposal, ventilation unit 13000 m3/h, w. circuit connected … 38 %; Disposal, thermal insulation, 30mm, 40kg/m3, reinforced alum… 7 %; Disposal, EI 30 fire insulation, 50mm, 120kg/m3, reinforced … 7 %; Disposal, ventilation duct, steel, zinc coated, s= 0.75mm 5 %; Disposal, silencer for ventilator unit 13000 m3/h, modular 5 %; Disposal, ventilation duct, steel, zinc coated, s= 0.62mm 5 %.

Interpretation

Significant issues

Direct exchanges dominating climate change: Disposal, ventilation unit 13000 m3/h, w. circuit connected … 38 %; Disposal, thermal insulation, 30mm, 40kg/m3, reinforced alum… 7 %; Disposal, EI 30 fire insulation, 50mm, 120kg/m3, reinforced … 7 %; Disposal, ventilation duct, steel, zinc coated, s= 0.75mm 5 %; Disposal, silencer for ventilator unit 13000 m3/h, modular 5 %; Disposal, ventilation duct, steel, zinc coated, s= 0.62mm 5 %. Most sensitive exchanges (Section 6.3): Disposal, ventilation unit 13000 m3/h, w. circuit connected heat exchanger [CH] (-7.6 / +9.5 %); Disposal, thermal insulation, 30mm, 40kg/m3, reinforced alumium foil [CH] (-1.4 / +1.7 %); Disposal, EI 30 fire insulation, 50mm, 120kg/m3, reinforced alumium foil [CH] (-1.3 / +1.6 %).

Independent recalculation

Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026):

Category Graph Published Graph / published
Acidification 3.287 7.074 0.465
Climate change-Biogenic 2.219 2.219 1.000
Climate change-Fossil 1.033e+04 1.033e+04 1.000
Climate change-Land use and land use change 0.4064 0.4064 1.000
Climate change 1.033e+04 1.033e+04 1.000
EF-particulate Matter 3.077e-04 3.077e-04 1.000
Ecotoxicity, freshwater_inorganics 4.263e+04 4.452e+04 0.958
Ecotoxicity, freshwater_organics 183.7 183.1 1.003
Ecotoxicity, freshwater 4.281e+04 4.47e+04 0.958
Eutrophication marine 3.817 3.817 1.000
Eutrophication, freshwater 2.428 2.428 1.000
Eutrophication, terrestrial 26.97 34.2 0.789
Human toxicity, cancer_inorganics 5.194e-07 5.177e-07 1.003
Human toxicity, cancer_organics 2.674e-07 2.674e-07 1.000
Human toxicity, cancer 7.867e-07 7.851e-07 1.002
Human toxicity, non-cancer_inorganics 3.165e-05 3.149e-05 1.005
Human toxicity, non-cancer_organics 2.231e-06 2.231e-06 1.000
Human toxicity, non-cancer 3.388e-05 3.372e-05 1.005
Ionising radiation, human health 365.3 365.3 1.000
Land use 1.623e+04 9356 1.735
Ozone depletion 4.337e-05 4.337e-05 1.000
Photochemical ozone formation - human health 10.54 10.54 1.000
Resource use, fossils 1.98e+04 1.98e+04 1.000
Resource use, minerals and metals 0.002561 0.00219 1.169
Water use 1401 1413 0.991
Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like.
Also published by BAFU for this dataset: IPCC 2021 GWP100 1.033e+04 kg CO2 eq; Ecological Scarcity
2021 total 2.215e+07 UBP.

Sensitivity check

One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.

Exchange Base Low / high Range Δ GWP100 (%) Δ other categories (max %)
Disposal, ventilation unit 13000 m3/h, w. circuit connected heat exchanger [CH] 4.635 p ×0.797 / ×1.25 lognormal, GSD² 1.26 -7.6 / +9.5 15.1 (Water use)
Disposal, thermal insulation, 30mm, 40kg/m3, reinforced alumium foil [CH] 4730 m2 ×0.81 / ×1.23 lognormal, GSD² 1.24 -1.4 / +1.7 4.0 (Eutrophication, freshwater)
Disposal, EI 30 fire insulation, 50mm, 120kg/m3, reinforced alumium foil [CH] 2735 m2 ×0.81 / ×1.23 lognormal, GSD² 1.24 -1.3 / +1.6 11.4 (Eutrophication, freshwater)
Disposal, silencer for ventilator unit 13000 m3/h, modular [CH] 20.54 p ×0.797 / ×1.25 lognormal, GSD² 1.26 -1.0 / +1.3 2.5 (Eutrophication marine)
Disposal, ventilation unit 6700 m3/h, w. circuit connected heat exchanger [CH] 1 p ×0.797 / ×1.25 lognormal, GSD² 1.26 -1.0 / +1.2 1.7 (Water use)
Disposal, ventilation duct, steel, zinc coated, s= 0.75mm [CH] 2870 m2 ×0.81 / ×1.23 lognormal, GSD² 1.24 -1.0 / +1.2 2.8 (Ionising radiation, human health)
Disposal, ventilation duct, steel, zinc coated, s= 0.62mm [CH] 2832 m2 ×0.81 / ×1.23 lognormal, GSD² 1.24 -0.9 / +1.2 2.3 (Ionising radiation, human health)
Disposal, ventilator unit 13000 m3/h, modular, w. filter, without silencer [CH] 1 p ×0.797 / ×1.25 lognormal, GSD² 1.26 -0.7 / +0.9 1.5 (Water use)
Disposal, ventilation unit 3500 m3/h, w. cross plate heat excanger [CH] 0.977 p ×0.797 / ×1.25 lognormal, GSD² 1.26 -0.6 / +0.7 0.9 (Water use)
Disposal, spiral-seam duct, steel, zinc coated, s= 0.5mm [CH] 868.6 m2 ×0.81 / ×1.23 lognormal, GSD² 1.24 -0.5 / +0.7 0.7 (Climate change-Fossil)
Disposal, ventilation unit 1800 m3/h, w. cross plate heat excanger [CH] 1.378 p ×0.797 / ×1.25 lognormal, GSD² 1.26 -0.5 / +0.6 0.7 (Human toxicity, cancer_inorganics)
Disposal, ventilation duct, steel, zinc coated, s= 0.87mm [CH] 1446 m2 ×0.81 / ×1.23 lognormal, GSD² 1.24 -0.5 / +0.6 1.6 (Ionising radiation, human health)
Disposal, ventilation unit 3500 m3/h, w. circuit connected heat exchanger [CH] 0.717 p ×0.797 / ×1.25 lognormal, GSD² 1.26 -0.4 / +0.5 0.7 (Water use)
Disposal, ventilator unit 3500 m3/h, modular, w. filter, without silencer [CH] 1.694 p ×0.797 / ×1.25 lognormal, GSD² 1.26 -0.4 / +0.5 0.7 (Water use)
Disposal, ventilation system, Pflegezentrum Witikon, various components [CH] 1 p ×0.81 / ×1.23 lognormal, GSD² 1.24 -0.4 / +0.5 0.9 (Ionising radiation, human health)

Uncertainty analysis

Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.

Comparison with other data

No other location of this dataset in the graph.

Conclusions and limitations

GWP100 1.033e+04 kg CO2 eq per p (95 % interval 9363–1.261e+04). Dominant contributors: Disposal, ventilation unit 13000 m3/h, w. circuit connected … 38 %; Disposal, thermal insulation, 30mm, 40kg/m3, reinforced alum… 7 %; Disposal, EI 30 fire insulation, 50mm, 120kg/m3, reinforced … 7 %; Disposal, ventilation duct, steel, zinc coated, s= 0.75mm 5 %; Disposal, silencer for ventilator unit 13000 m3/h, modular 5 %; Disposal, ventilation duct, steel, zinc coated, s= 0.62mm 5 %. Most sensitive: Disposal, ventilation unit 13000 m3/h, w. circuit connected heat exchanger [CH] (-7.6 / +9.5 %); Disposal, thermal insulation, 30mm, 40kg/m3, reinforced alumium foil [CH] (-1.4 / +1.7 %); Disposal, EI 30 fire insulation, 50mm, 120kg/m3, reinforced alumium foil [CH] (-1.3 / +1.6 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.

Final control

Item Status Detail
reference flow PASS production amount 1.0 p
closure: sum of direct contributions = dataset score (all 25 categories) PASS largest relative gap 5.3e-16
independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) PASS graph / published = 1; categories within ±5 %: 21/25
every technosphere input of the EcoSpold delivery is in the graph PASS all present (bafu_links_check.py)
uncertainty declared on the direct exchanges PASS 32/32 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values
Monte Carlo 95 % interval contains the deterministic score PASS 1.033e+04 in [9363, 1.261e+04]
time period declared PASS 2014-01/2014-12
geography is a known location code PASS CH
sources cited PASS 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them

References

  1. Klingler M., Kasser U., Savi D., Primas A., Stettler Y., Gujer P. (2014) Ökobilanzdaten für Lüftungs- und Wärmeanlagen. Schlussbericht, BFE. Bundesamt für Energie (BFE). Bern. Type: Separate publication Source: Report First author: Klingler M. Other authors: Kasser U., Savi D., Primas A., Stettler Y., Gujer P. Year: 2014 Title of anthology: Schlussbericht, BFE Place of publication: Bern Publisher:… — published source; as declared by BAFU (not found in OpenAlex/Crossref)
  2. Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — database; dataset citation
  3. International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva.
  4. Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. (tdc-doc method reference; title, version and year to verify against the user's copy)
  5. European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra.
  6. Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236

Annex — licence and terms of use