Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Electricity mix [LU], per 1 kWh. EF v3.1 climate change 0.341 kg CO2 eq (Monte Carlo 95 % interval 0.3003–0.5108). Main contributors: Electricity imports 81 %; Electricity, hydropower, at pumped storage power plant 17 %; Electricity, from natural gas 2 %. Status: final control passed.
Item Value
Dataset name Electricity mix
Dataset UUID / graph id 0425d8d1-5c0b-374c-95c5-e8bc0f1d729d / activity:electricity_mix__lu
Reference product, unit Electricity mix, 1 kWh
Location LU — Data apply to utilities and auto-producers.
Time period 2023/2023
Category electricity / supply mix
Source database BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1
Publisher Swiss Federal Office for the Environment (FOEN/BAFU)
Background database BAFU 2026 v1 (graph bafuquery-db)
LCIA method EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix)
Status final control passed
Documented by tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17

Introduction

Electricity domestic net production and import shares are based on annual averages for the years 2021-2023. Only gross to net electicity conversion losses are included as the power plants could not be operated without these, whereas other losses (such as transmission and distribution losses) are not included. Electricity trade between countries is included. UUID: 0425d8d1-5c0b-374c-95c5-e8bc0f1d729d

This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.

Goal and scope

Function, functional unit and reference flow

Reference flow: 1 kWh of Electricity mix (LU). All results are given per unit of the reference flow.

System boundary

Included are the shares of corresponding electricity production by technology and country at the busbar. Not included are transformation, transport or distribution losses.

Technology

No technology description is provided because the dataset just describes the power plant portfolio of the respective country using current average technology per energy carrier.

Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).

LCIA method

EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.

Life cycle inventory

Inventory table

Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).

Exchange Type Location / compartment Amount Unit Uncertainty Pedigree GWP share (%) Notes
Electricity imports technosphere LU 0.75721 kWh lognormal, GSD² 1.07 — 80.5 ████████████████
Electricity, hydropower, at pumped storage power plant technosphere LU 0.11912 kWh lognormal, GSD² 1.05 — 16.7 ███
Electricity, from natural gas technosphere LU 0.010433 kWh lognormal, GSD² 1.05 — 1.8 ·
Electricity, at cogen 1MWth, wood chips, allocation exergy technosphere CH 0.014073 kWh lognormal, GSD² 1.11 — 0.3 ·
Electricity, production mix photovoltaic, at plant technosphere LU 0.027785 kWh lognormal, GSD² 1.05 — 0.3 ·
Electricity, at cogen with biogas engine, allocation exergy technosphere CH 0.0046633 kWh lognormal, GSD² 1.11 — 0.2 ·
Electricity, at wind farm technosphere RER 0.047517 kWh lognormal, GSD² 1.05 — 0.2 ·
Electricity, hydropower, at run-of-river power plant technosphere RER 0.0078166 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, hydropower, at reservoir power plant technosphere CH 0.0019852 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity from waste, at municipal waste incineration plant technosphere CH 0.0093991 kWh lognormal, GSD² 1.11 — -0.0 ·

Data quality

0 of 10 direct exchanges carry a declared pedigree, 10 carry a distribution.

Field As declared by the publisher
Data generator / entry / validation data generator: Christopher Oberschelp (ETH); data entry: Christopher Oberschelp (ETH); validation (proof reading): René Itten (ZHAW)
sampling procedure Statistical data
uncertainty adjustments none
validation details manual review of spold files and documentation
time period comment Time period of statistics used.

Data gaps, proxies and assumptions

None recorded.

Life cycle impact assessment (EF v3.1)

Per 1 kWh. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.

Impact category Indicator Unit Result 2.5 % 97.5 % GSD²
Acidification Accumulated Exceedance (AE) mol H+ eq 5.323e-04 4.867e-04 8.574e-04 1.35
Climate change-Biogenic Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.004989 0.003564 0.008513 1.54
Climate change-Fossil Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.3343 0.2951 0.5 1.33
Climate change-Land use and land use change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.001688 8.649e-04 0.003791 2.15
Climate change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.341 0.3003 0.5108 1.33
EF-particulate Matter Impact on human health disease incidence 4.010e-09 3.685e-09 7.705e-09 1.45
Ecotoxicity, freshwater_inorganics Comparative Toxic Unit for ecosystems (CTUe) CTUe 0.8788 0.7051 2.038 1.73
Ecotoxicity, freshwater_organics Comparative Toxic Unit for ecosystems (CTUe) CTUe 0.009341 0.008021 0.03208 2.03
Ecotoxicity, freshwater Comparative Toxic Unit for ecosystems (CTUe) CTUe 0.8881 0.7156 2.061 1.72
Eutrophication marine Fraction of nutrients reaching marine end compartment (N) kg N eq 2.076e-04 1.889e-04 3.347e-04 1.36
Eutrophication, freshwater Fraction of nutrients reaching freshwater end compartment (P) kg P eq 3.334e-04 1.391e-04 0.001218 3.07
Eutrophication, terrestrial Accumulated Exceedance (AE) mol N eq 0.001409 0.001285 0.002369 1.38
Human toxicity, cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 2.356e-11 2.304e-11 9.437e-11 2.04
Human toxicity, cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 3.281e-10 2.294e-10 5.624e-10 1.6
Human toxicity, cancer Comparative Toxic Unit for human (CTUh) CTUh 3.517e-10 2.656e-10 6.133e-10 1.56
Human toxicity, non-cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 1.553e-09 1.431e-09 5.904e-09 2.03
Human toxicity, non-cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 7.141e-11 6.830e-11 1.425e-10 1.46
Human toxicity, non-cancer Comparative Toxic Unit for human (CTUh) CTUh 1.625e-09 1.515e-09 5.999e-09 1.99
Ionising radiation, human health Human exposure efficiency relative to U235 kBq U235 eq 0.2031 0.06897 1.259 4.5
Land use Soil quality index pt (soil quality index) 3.276 2.218 6.067 1.7
Ozone depletion Ozone Depletion Potential (ODP) kg CFC-11 eq 6.810e-09 4.809e-09 2.067e-08 2.12
Photochemical ozone formation - human health Tropospheric ozone concentration increase kg NMVOC eq 5.536e-04 4.922e-04 0.001221 1.58
Resource use, fossils Abiotic resource depletion fossil fuels (ADP-fossil) MJ 5.352 4.599 10.97 1.56
Resource use, minerals and metals Abiotic resource depletion (ADP ultimate reserve) kg Sb eq 3.913e-07 3.713e-07 8.172e-07 1.51
Water use User deprivation potential (deprivation-weighted water consumption) m3 world eq deprived 0.03549 -137.7 73.18 —

Climate change 0.341 kg CO2 eq per kWh. Main contributors: Electricity imports 81 %; Electricity, hydropower, at pumped storage power plant 17 %; Electricity, from natural gas 2 %.

Interpretation

Significant issues

Direct exchanges dominating climate change: Electricity imports 81 %; Electricity, hydropower, at pumped storage power plant 17 %; Electricity, from natural gas 2 %. Most sensitive exchanges (Section 6.3): Electricity imports [LU] (-5.3 / +5.6 %); Electricity, hydropower, at pumped storage power plant [LU] (-0.8 / +0.8 %); Electricity, from natural gas [LU] (-0.1 / +0.1 %).

Independent recalculation

Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh:

Category Graph Published Graph / published
Acidification 5.323e-04 5.258e-04 1.012
Climate change-Biogenic 0.004989 0.004989 1.000
Climate change-Fossil 0.3343 0.3343 1.000
Climate change-Land use and land use change 0.001688 0.001688 1.000
Climate change 0.341 0.341 1.000
EF-particulate Matter 4.010e-09 4.010e-09 1.000
Ecotoxicity, freshwater_inorganics 0.8788 0.9081 0.968
Ecotoxicity, freshwater_organics 0.009341 0.009182 1.017
Ecotoxicity, freshwater 0.8881 0.9171 0.968
Eutrophication marine 2.076e-04 2.075e-04 1.000
Eutrophication, freshwater 3.334e-04 3.334e-04 1.000
Eutrophication, terrestrial 0.001409 0.001614 0.873
Human toxicity, cancer_inorganics 2.356e-11 1.961e-11 1.201
Human toxicity, cancer_organics 3.281e-10 3.281e-10 1.000
Human toxicity, cancer 3.517e-10 3.478e-10 1.011
Human toxicity, non-cancer_inorganics 1.553e-09 1.404e-09 1.107
Human toxicity, non-cancer_organics 7.141e-11 7.140e-11 1.000
Human toxicity, non-cancer 1.625e-09 1.475e-09 1.101
Ionising radiation, human health 0.2031 0.2031 1.000
Land use 3.276 2.692 1.217
Ozone depletion 6.810e-09 6.810e-09 1.000
Photochemical ozone formation - human health 5.536e-04 5.536e-04 1.000
Resource use, fossils 5.352 5.352 1.000
Resource use, minerals and metals 3.913e-07 3.768e-07 1.039
Water use 0.03549 0.04945 0.718
Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like.
Also published by BAFU for this dataset: IPCC 2021 GWP100 0.341 kg CO2 eq; Ecological Scarcity
2021 total 587.1 UBP.

Sensitivity check

One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.

Exchange Base Low / high Range Δ GWP100 (%) Δ other categories (max %)
Electricity imports [LU] 0.7572 kWh ×0.935 / ×1.07 lognormal, GSD² 1.07 -5.3 / +5.6 5.8 (Ionising radiation, human health)
Electricity, hydropower, at pumped storage power plant [LU] 0.1191 kWh ×0.953 / ×1.05 lognormal, GSD² 1.05 -0.8 / +0.8 4.5 (Climate change-Land use and land use change)
Electricity, from natural gas [LU] 0.01043 kWh ×0.953 / ×1.05 lognormal, GSD² 1.05 -0.1 / +0.1 0.1 (Ecotoxicity, freshwater_organics)
Electricity, at cogen 1MWth, wood chips, allocation exergy [CH] 0.01407 kWh ×0.9 / ×1.11 lognormal, GSD² 1.11 -0.0 / +0.0 3.8 (Land use)
Electricity, at cogen with biogas engine, allocation exergy [CH] 0.004663 kWh ×0.9 / ×1.11 lognormal, GSD² 1.11 -0.0 / +0.0 1.0 (Climate change-Biogenic)
Electricity, production mix photovoltaic, at plant [LU] 0.02779 kWh ×0.953 / ×1.05 lognormal, GSD² 1.05 -0.0 / +0.0 0.7 (Resource use, minerals and metals)
Electricity, at wind farm [RER] 0.04752 kWh ×0.952 / ×1.05 lognormal, GSD² 1.05 -0.0 / +0.0 0.2 (Resource use, minerals and metals)
Electricity, hydropower, at reservoir power plant [CH] 0.001985 kWh ×0.9 / ×1.11 lognormal, GSD² 1.11 -0.0 / +0.0 0.0 (Climate change-Land use and land use change)
Electricity, hydropower, at run-of-river power plant [RER] 0.007817 kWh ×0.952 / ×1.05 lognormal, GSD² 1.05 -0.0 / +0.0 0.0 (Climate change-Biogenic)
Electricity from waste, at municipal waste incineration plant [CH] 0.009399 kWh ×0.9 / ×1.11 lognormal, GSD² 1.11 +0.0 / -0.0 0.0 (Resource use, minerals and metals)

Uncertainty analysis

Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.

Comparison with other data

Source Scope Value This dataset Ratio Note
bafu Electricity mix [ET] 0.006645 kg CO2 eq 0.341 51.31 same dataset name, other location
bafu Electricity mix [IS] 0.02727 kg CO2 eq 0.341 12.50 same dataset name, other location
bafu Electricity mix [SE] 0.03344 kg CO2 eq 0.341 10.20 same dataset name, other location
bafu Electricity mix [NO] 0.04653 kg CO2 eq 0.341 7.33 same dataset name, other location
bafu Electricity mix [FR] 0.0644 kg CO2 eq 0.341 5.29 same dataset name, other location
bafu Electricity mix [GLO] 0.5483 kg CO2 eq 0.341 0.62 same dataset name, other location
bafu Electricity mix [BA] 0.8037 kg CO2 eq 0.341 0.42 same dataset name, other location
bafu Electricity mix [KZ] 0.8184 kg CO2 eq 0.341 0.42 same dataset name, other location
bafu Electricity mix [ID] 0.8232 kg CO2 eq 0.341 0.41 same dataset name, other location
bafu Electricity mix [IN] 0.9109 kg CO2 eq 0.341 0.37 same dataset name, other location
bafu Electricity mix [ZA] 0.9667 kg CO2 eq 0.341 0.35 same dataset name, other location

Conclusions and limitations

GWP100 0.341 kg CO2 eq per kWh (95 % interval 0.3003–0.5108). Dominant contributors: Electricity imports 81 %; Electricity, hydropower, at pumped storage power plant 17 %; Electricity, from natural gas 2 %. Most sensitive: Electricity imports [LU] (-5.3 / +5.6 %); Electricity, hydropower, at pumped storage power plant [LU] (-0.8 / +0.8 %); Electricity, from natural gas [LU] (-0.1 / +0.1 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.

Final control

Item Status Detail
reference flow PASS production amount 1.0 kWh
closure: sum of direct contributions = dataset score (all 25 categories) PASS largest relative gap 2.1e-16
independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh (climate change) PASS graph / published = 1; categories within ±5 %: 19/25
every technosphere input of the EcoSpold delivery is in the graph PASS all present (bafu_links_check.py)
uncertainty declared on the direct exchanges PASS 10/10 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values
Monte Carlo 95 % interval contains the deterministic score PASS 0.341 in [0.3003, 0.5108]
time period declared PASS 2023/2023
geography is a known location code PASS LU
sources cited PASS 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them

References

  1. Oberschelp C. (2025) 2025 - Electricity mixes in UVEK database - Oberschelp. Oberschelp Consulting — published source; as declared by BAFU (not found in OpenAlex/Crossref)
  2. Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — database; dataset citation
  3. International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva.
  4. Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. (tdc-doc method reference; title, version and year to verify against the user's copy)
  5. European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra.
  6. Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236

Annex — licence and terms of use

BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.


To suggest a correction or a dataset that does not exist yet, use Propose a dataset.

datasets/bafu/0425d8d1-5c0b-374c-95c5-e8bc0f1d729d.txt · Last modified: by 127.0.0.1