Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Electricity imports [LV], per 1 kWh. EF v3.1 climate change 0.2569 kg CO2 eq (Monte Carlo 95 % interval 0.2336–0.3513). Main contributors: Electricity, oil, at power plant 31 %; Electricity, from natural gas 19 %; Electricity, industrial gas, at power plant 15 %; Electricity, hard coal, at power plant 7 %; Electricity, lignite, at power plant 4 %; Electricity, hard coal, at power plant 3 %. Status: final control passed.
Item Value
Dataset name Electricity imports
Dataset UUID / graph id 1182bef7-c195-342a-999f-38685406ed74 / activity:electricity_imports__lv
Reference product, unit Electricity imports, 1 kWh
Location LV — Data apply to utilities and auto-producers.
Time period 2023/2023
Category electricity / Electricity imports
Source database BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1
Publisher Swiss Federal Office for the Environment (FOEN/BAFU)
Background database BAFU 2026 v1 (graph bafuquery-db)
LCIA method EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix)
Status final control passed
Documented by tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17

Introduction

Electricity imports in this dataset are representing physical electricity imports as far as such data is available from statistical data sources, in case of data gaps supplemented by trade flow information that also includes physical amounts. Unrealistic values were removed where present. The imported electricity is assumed to reflect the corresponding foreign consumption mix. UUID: 1182bef7-c195-342a-999f-38685406ed74

This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.

Goal and scope

Function, functional unit and reference flow

Reference flow: 1 kWh of Electricity imports (LV). All results are given per unit of the reference flow.

System boundary

Included are the shares of corresponding electricity production by technology and country at the busbar. Not included are transformation, transport or distribution losses.

Technology

No technology description is provided because the dataset just describes the power plant portfolio of the respective country using current average technology per energy carrier.

Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).

LCIA method

EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.

Life cycle inventory

Inventory table

Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).

Exchange Type Location / compartment Amount Unit Uncertainty Pedigree GWP share (%) Notes
Electricity, oil, at power plant technosphere SE 0.1187 kWh lognormal, GSD² 1.11 — 30.7 ██████
Electricity, from natural gas technosphere JP 0.084642 kWh lognormal, GSD² 1.11 — 19.1 ████
Electricity, industrial gas, at power plant technosphere DE 0.032271 kWh lognormal, GSD² 1.11 — 14.8 ███
Electricity, hard coal, at power plant technosphere RU 0.016904 kWh lognormal, GSD² 1.05 — 7.3 █
Electricity, lignite, at power plant technosphere PL 0.010353 kWh lognormal, GSD² 1.11 — 4.4 █
Electricity, hard coal, at power plant technosphere PL 0.0075438 kWh lognormal, GSD² 1.05 — 3.2 █
Electricity, hard coal, at power plant technosphere PL 0.0066793 kWh lognormal, GSD² 1.11 — 2.9 █
Electricity, peat, at power plant technosphere NORDEL 0.0056215 kWh lognormal, GSD² 1.11 — 2.5 ·
Electricity, lignite, at power plant technosphere PL 0.0039027 kWh lognormal, GSD² 1.05 — 1.7 ·
Electricity, at cogen 1MWth, wood chips, allocation exergy technosphere CH 0.067647 kWh lognormal, GSD² 1.11 — 1.6 ·
Electricity, from natural gas technosphere DE 0.0076864 kWh lognormal, GSD² 1.11 — 1.4 ·
Electricity, at cogen 1MWth, wood chips, allocation exergy technosphere CH 0.034382 kWh lognormal, GSD² 1.11 — 0.8 ·
Electricity, industrial gas, at power plant technosphere DE 0.0016475 kWh lognormal, GSD² 1.11 — 0.8 ·
Electricity, hydropower, at reservoir power plant technosphere FI 0.048577 kWh lognormal, GSD² 1.05 — 0.7 ·
Electricity, industrial gas, at power plant technosphere DE 0.0013272 kWh lognormal, GSD² 1.11 — 0.6 ·
Electricity, hydropower, at pumped storage power plant technosphere LT 0.0058422 kWh lognormal, GSD² 1.05 — 0.6 ·
Electricity, hydropower, at reservoir power plant technosphere FI 0.034547 kWh lognormal, GSD² 1.11 — 0.5 ·
Electricity, production mix photovoltaic, at plant technosphere SE 0.038381 kWh lognormal, GSD² 1.11 — 0.5 ·
Electricity, at cogen 300kWth, diesel, allocation exergy technosphere CH 0.0016047 kWh lognormal, GSD² 1.11 — 0.5 ·
Electricity, from natural gas technosphere DE 0.0025045 kWh lognormal, GSD² 1.11 — 0.5 ·
Electricity, from natural gas technosphere DE 0.0020972 kWh lognormal, GSD² 1.11 — 0.4 ·
Electricity, nuclear, at power plant boiling water reactor technosphere DE 0.090348 kWh lognormal, GSD² 1.11 — 0.4 ·
Electricity, at wind farm technosphere RER 0.0626 kWh lognormal, GSD² 1.05 — 0.3 ·
Electricity, oil, at power plant technosphere SK 7.9062e-04 kWh lognormal, GSD² 1.11 — 0.3 ·
Electricity, at cogen 300kWth, diesel, allocation exergy technosphere CH 9.2915e-04 kWh lognormal, GSD² 1.11 — 0.3 ·
Electricity, nuclear, at power plant pressure water reactor technosphere DE 0.050644 kWh lognormal, GSD² 1.11 — 0.2 ·
Electricity, at wind farm technosphere RER 0.030524 kWh lognormal, GSD² 1.05 — 0.2 ·
Electricity, production mix photovoltaic, at plant technosphere CZ 0.013947 kWh lognormal, GSD² 1.11 — 0.2 ·
Electricity, from natural gas technosphere DE 8.4987e-04 kWh lognormal, GSD² 1.11 — 0.2 ·
Electricity, at wind farm technosphere RER 0.027774 kWh lognormal, GSD² 1.05 — 0.2 ·
Electricity, hydropower, at reservoir power plant technosphere FI 0.0081657 kWh lognormal, GSD² 1.11 — 0.1 ·
Electricity, oil, at power plant technosphere FI 5.3189e-04 kWh lognormal, GSD² 1.05 — 0.1 ·
Electricity, at cogen 1MWth, wood chips, allocation exergy technosphere CH 0.0047238 kWh lognormal, GSD² 1.11 — 0.1 ·
Electricity, at cogen 300kWth, diesel, allocation exergy technosphere CH 3.8357e-04 kWh lognormal, GSD² 1.11 — 0.1 ·
Electricity, at wind farm technosphere RER 0.020087 kWh lognormal, GSD² 1.05 — 0.1 ·
Electricity, oil, at power plant technosphere SK 2.6772e-04 kWh lognormal, GSD² 1.11 — 0.1 ·
Electricity, oil, at power plant technosphere FI 4.5814e-04 kWh lognormal, GSD² 1.11 — 0.1 ·
Electricity, industrial gas, at power plant technosphere DE 2.1902e-04 kWh lognormal, GSD² 1.11 — 0.1 ·
Electricity, nuclear, at power plant pressure water reactor technosphere CN 0.025634 kWh lognormal, GSD² 1.11 — 0.1 ·
Electricity, peat, at power plant technosphere NORDEL 2.0945e-04 kWh lognormal, GSD² 1.11 — 0.1 ·
Electricity, at cogen 1MWth, wood chips, allocation exergy technosphere CH 0.0032858 kWh lognormal, GSD² 1.11 — 0.1 ·
Electricity, hydropower, at pumped storage power plant technosphere RU 3.2098e-04 kWh lognormal, GSD² 1.05 — 0.1 ·
Electricity, lignite, at power plant technosphere DE 1.7689e-04 kWh lognormal, GSD² 1.05 — 0.1 ·
Electricity, nuclear, at power plant boiling water reactor technosphere DE 0.017572 kWh lognormal, GSD² 1.11 — 0.1 ·
Electricity, industrial gas, at power plant technosphere DE 1.4027e-04 kWh lognormal, GSD² 1.05 — 0.1 ·
Electricity, hydropower, at reservoir power plant technosphere FI 0.0040625 kWh lognormal, GSD² 1.11 — 0.1 ·
Electricity, at cogen with biogas engine, allocation exergy technosphere CH 9.1771e-04 kWh lognormal, GSD² 1.11 — 0.1 ·
Electricity, at cogen with biogas engine, allocation exergy technosphere CH 8.6820e-04 kWh lognormal, GSD² 1.11 — 0.1 ·
Electricity, industrial gas, at power plant technosphere DE 1.2107e-04 kWh lognormal, GSD² 1.11 — 0.1 ·
Electricity, production mix photovoltaic, at plant technosphere FI 0.0035166 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, hydropower, at pumped storage power plant technosphere PL 1.0931e-04 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, production mix photovoltaic, at plant technosphere SE 0.0035207 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, at cogen 300kWth, diesel, allocation exergy technosphere CH 1.4440e-04 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, nuclear, at power plant boiling water reactor technosphere DE 0.010163 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, from natural gas technosphere DE 2.0920e-04 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, hydropower, at run-of-river power plant technosphere RER 0.024497 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, production mix photovoltaic, at plant technosphere CZ 0.0027143 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, hard coal, at power plant technosphere DE 7.8835e-05 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, nuclear, at power plant pressure water reactor technosphere DE 0.0083838 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, peat, at power plant technosphere NORDEL 5.5465e-05 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, hydropower, at run-of-river power plant technosphere RER 0.016131 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, hard coal, at power plant technosphere PL 4.9128e-05 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, at cogen 1MWth, wood chips, allocation exergy technosphere CH 8.5044e-04 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, peat, at power plant technosphere NORDEL 4.0915e-05 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, at wind farm technosphere RER 0.0032149 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, at cogen with biogas engine, allocation exergy technosphere CH 2.5368e-04 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, from natural gas technosphere DE 8.3280e-05 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, at cogen with biogas engine, allocation exergy technosphere CH 1.9282e-04 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, at cogen with biogas engine, allocation exergy technosphere CH 1.5864e-04 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, hard coal, at power plant technosphere NL 2.7140e-05 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, oil, at power plant technosphere SE 3.8036e-05 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, at cogen 300kWth, diesel, allocation exergy technosphere CH 3.0186e-05 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, lignite, at power plant technosphere CZ 1.8215e-05 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, at wind farm technosphere RER 0.0012614 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, from natural gas technosphere NL 3.7175e-05 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, at cogen with biogas engine, allocation exergy technosphere CH 9.3960e-05 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, production mix photovoltaic, at plant technosphere CN 4.6093e-04 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, hydropower, at run-of-river power plant technosphere RER 0.0034842 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, oil, at power plant technosphere DE 9.2246e-06 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, production mix photovoltaic, at plant technosphere DE 3.0218e-04 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, at wind farm technosphere RER 5.8540e-04 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, from natural gas technosphere NL 1.8188e-05 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, hydropower, at pumped storage power plant technosphere DE 1.1140e-05 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, at wind farm technosphere RER 4.6298e-04 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, industrial gas, at power plant technosphere NL 4.0751e-06 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, at wind farm technosphere RER 4.0802e-04 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, at cogen 300kWth, diesel, allocation exergy technosphere CH 6.1239e-06 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, from natural gas technosphere NL 1.0225e-05 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, at cogen 300kWth, diesel, allocation exergy technosphere CH 4.6761e-06 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, at cogen 1MWth, wood chips, allocation exergy technosphere CH 5.2927e-05 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, from natural gas technosphere GB 7.2207e-06 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, from natural gas technosphere AT 6.1687e-06 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, hard coal, at power plant technosphere CZ 2.2190e-06 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, production mix photovoltaic, at plant technosphere DK 9.1410e-05 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, from natural gas technosphere AT 5.2402e-06 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, hydropower, at run-of-river power plant technosphere RER 6.7907e-04 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, hard coal, at power plant technosphere NL 2.2964e-06 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, hydropower, at pumped storage power plant technosphere SE 3.0689e-05 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, hydropower, at pumped storage power plant technosphere NO 2.3955e-05 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, hard coal, at power plant technosphere SK 1.8327e-06 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, at cogen 1MWth, wood chips, allocation exergy technosphere CH 2.9651e-05 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, oil, at power plant technosphere DK 1.9988e-06 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, hydropower, at run-of-river power plant technosphere RER 4.7849e-04 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, at cogen 300kWth, diesel, allocation exergy technosphere CH 2.2853e-06 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, hard coal, at power plant technosphere PL 1.2590e-06 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, industrial gas, at power plant technosphere NL 9.6793e-07 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, production mix photovoltaic, at plant technosphere NL 3.4332e-05 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, lignite, at power plant technosphere SK 7.7300e-07 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, hydropower, at run-of-river power plant technosphere RER 2.7211e-04 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, at cogen with biogas engine, allocation exergy technosphere CH 5.5314e-06 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, from natural gas technosphere BE 1.8368e-06 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, from natural gas technosphere FR 1.6643e-06 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, at cogen 300kWth, diesel, allocation exergy technosphere CH 1.0245e-06 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, industrial gas, at power plant technosphere AT 8.3065e-07 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, at cogen 1MWth, wood chips, allocation exergy technosphere CH 1.1682e-05 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, hydropower, at pumped storage power plant technosphere CZ 9.6594e-07 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, oil, at power plant technosphere SK 5.6813e-07 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, hydropower, at pumped storage power plant technosphere LU 9.6212e-07 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, from natural gas technosphere AT 9.1788e-07 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, at cogen with biogas engine, allocation exergy technosphere CH 2.5009e-06 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, production mix photovoltaic, at plant technosphere NO 1.1861e-05 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, at wind farm technosphere RER 2.3943e-05 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, industrial gas, at power plant technosphere BE 2.3986e-07 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, nuclear, at power plant pressure water reactor technosphere DE 2.8797e-05 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, nuclear, at power plant pressure water reactor technosphere DE 2.7949e-05 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, industrial gas, at power plant technosphere AT 2.8238e-07 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, hard coal, at power plant technosphere NL 2.4804e-07 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, hydropower, at pumped storage power plant technosphere AT 8.6795e-07 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, hydropower, at run-of-river power plant technosphere RER 6.1979e-05 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, at cogen 1MWth, wood chips, allocation exergy technosphere CH 3.5455e-06 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, industrial gas, at power plant technosphere AT 2.2985e-07 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, oil, at power plant technosphere FR 2.4442e-07 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, hydropower, at reservoir power plant technosphere CH 1.8161e-05 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, nuclear, at power plant pressure water reactor technosphere FR 2.2985e-05 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, at cogen 1MWth, wood chips, allocation exergy technosphere CH 2.3446e-06 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, at wind farm technosphere RER 8.6691e-06 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, hydropower, at pumped storage power plant technosphere SK 3.5020e-07 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, at cogen 300kWth, diesel, allocation exergy technosphere CH 1.4530e-07 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, at cogen 1MWth, wood chips, allocation exergy technosphere CH 1.7429e-06 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, from natural gas technosphere AT 2.0874e-07 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, hydropower, at pumped storage power plant technosphere CH 8.4623e-07 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, at cogen with biogas engine, allocation exergy technosphere CH 5.7046e-07 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, at cogen 1MWth, wood chips, allocation exergy technosphere CH 1.4614e-06 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, at wind farm technosphere RER 6.4789e-06 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, at cogen 300kWth, diesel, allocation exergy technosphere CH 1.1650e-07 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, at cogen with biogas engine, allocation exergy technosphere CH 5.2066e-07 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, industrial gas, at power plant technosphere NL 5.8396e-08 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, at cogen with biogas engine, allocation exergy technosphere CH 4.9256e-07 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, at cogen 300kWth, diesel, allocation exergy technosphere CH 1.0574e-07 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, industrial gas, at power plant technosphere AT 8.0905e-08 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, hard coal, at power plant technosphere FR 5.8854e-08 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, production mix photovoltaic, at plant technosphere CZ 2.3380e-06 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, industrial gas, at power plant technosphere FR 4.7249e-08 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, oil, at power plant technosphere AT 7.4274e-08 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, hard coal, at power plant technosphere SK 5.5740e-08 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, lignite, at power plant technosphere SI 5.5655e-08 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, at cogen 1MWth, wood chips, allocation exergy technosphere CH 8.5785e-07 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, at wind farm technosphere RER 3.7547e-06 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, hydropower, at pumped storage power plant technosphere UA 1.2745e-07 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, hydropower, at reservoir power plant technosphere CH 5.5720e-06 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, from natural gas technosphere ES 8.3613e-08 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, nuclear, at power plant pressure water reactor technosphere DE 4.8620e-06 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, nuclear, at power plant pressure water reactor technosphere DE 4.3911e-06 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, nuclear, at power plant pressure water reactor technosphere DE 4.3680e-06 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, from natural gas technosphere IT 8.3669e-08 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, production mix photovoltaic, at plant technosphere FR 1.3050e-06 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, production mix photovoltaic, at plant technosphere HU 1.4140e-06 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, hydropower, at pumped storage power plant technosphere GB 1.4269e-07 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, hydropower, at reservoir power plant technosphere CH 4.0294e-06 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, production mix photovoltaic, at plant technosphere BE 1.1091e-06 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, production mix photovoltaic, at plant technosphere GB 1.0425e-06 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, from natural gas technosphere GB 7.7260e-08 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, at cogen with biogas engine, allocation exergy technosphere CH 2.0384e-07 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, from natural gas technosphere AT 6.2965e-08 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, hydropower, at pumped storage power plant technosphere BE 1.3289e-07 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, lignite, at power plant technosphere HU 2.4767e-08 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, at cogen 300kWth, natural gas, allocation exergy technosphere CH 4.6035e-08 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, nuclear, at power plant pressure water reactor technosphere DE 2.8651e-06 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, from natural gas technosphere LU 4.1643e-08 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, oil, at power plant technosphere GB 1.8323e-08 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, hydropower, at run-of-river power plant technosphere RER 6.0253e-06 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, at cogen 300kWth, diesel, allocation exergy technosphere CH 2.9833e-08 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, lignite, at power plant technosphere RS 1.7507e-08 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, oil, at power plant technosphere SE 3.2159e-08 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, nuclear, at power plant pressure water reactor technosphere CH 1.5325e-06 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, at cogen 1MWth, wood chips, allocation exergy technosphere CH 3.3288e-07 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, hydropower, at run-of-river power plant technosphere RER 5.3760e-06 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, hydropower, at pumped storage power plant technosphere FR 2.0928e-07 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, nuclear, at power plant pressure water reactor technosphere FR 2.9247e-06 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, hard coal, at power plant technosphere BE 1.7647e-08 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, nuclear, at power plant boiling water reactor technosphere CH 1.1166e-06 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, at cogen 1MWth, wood chips, allocation exergy technosphere CH 2.7437e-07 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, at cogen with biogas engine, allocation exergy technosphere CH 9.4683e-08 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, hard coal, at power plant technosphere IT 1.3325e-08 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, at wind farm technosphere RER 9.8314e-07 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, lignite, at power plant technosphere RS 1.1119e-08 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, lignite, at power plant technosphere BA 1.0113e-08 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, production mix photovoltaic, at plant technosphere CH 4.5861e-07 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, hydropower, at run-of-river power plant technosphere RER 3.4039e-06 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, at cogen 300kWth, diesel, allocation exergy technosphere CH 1.6006e-08 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, oil, at power plant technosphere CZ 8.2820e-09 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, at cogen 1MWth, wood chips, allocation exergy technosphere CH 1.7109e-07 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, hydropower, at reservoir power plant technosphere CH 1.2056e-06 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, hydropower, at run-of-river power plant technosphere CH 2.9022e-06 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, oil, at power plant technosphere NL 1.3423e-08 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, production mix photovoltaic, at plant technosphere HU 3.8670e-07 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, hydropower, at reservoir power plant technosphere CH 1.1413e-06 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, lignite, at power plant technosphere MK 8.1804e-09 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, at wind farm technosphere RER 6.6533e-07 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, production mix photovoltaic, at plant technosphere AT 3.3018e-07 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, at cogen with biogas engine, allocation exergy technosphere CH 5.3418e-08 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, oil, at power plant technosphere SK 8.7723e-09 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, hydropower, at reservoir power plant technosphere CH 9.7903e-07 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, at cogen with biogas engine, allocation exergy technosphere CH 4.8684e-08 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, hydropower, at reservoir power plant technosphere CH 9.0098e-07 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, hard coal, at power plant technosphere ES 5.7026e-09 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, at cogen with biogas engine, allocation exergy technosphere CH 3.5184e-08 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, production mix photovoltaic, at plant technosphere HU 2.2279e-07 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, at cogen 1MWth, wood chips, allocation exergy technosphere CH 9.1223e-08 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, oil, at power plant technosphere ES 5.1248e-09 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, at wind farm technosphere RER 3.8380e-07 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, at cogen 300kWth, diesel, allocation exergy technosphere CH 7.1870e-09 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, at cogen with biogas engine, agricultural covered, alloc. exergy technosphere CH 3.4337e-08 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, at cogen with biogas engine, allocation exergy technosphere CH 3.0228e-08 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, at cogen 300kWth, biomethane, allocation exergy technosphere CH 1.5816e-08 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, hydropower, at reservoir power plant technosphere CH 5.5602e-07 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, hard coal, at power plant technosphere AT 5.5842e-09 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, hard coal, at power plant technosphere BE 4.3186e-09 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, at cogen 1MWth, wood chips, allocation exergy technosphere CH 7.1156e-08 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, from natural gas technosphere AT 8.5463e-09 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, hard coal, at power plant technosphere HR 3.8631e-09 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, at cogen 300kWth, diesel, allocation exergy technosphere CH 4.9733e-09 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, from natural gas technosphere AT 6.9710e-09 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, production mix photovoltaic, at plant technosphere LU 1.0075e-07 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, peat, at power plant technosphere NORDEL 2.7161e-09 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, hydropower, at run-of-river power plant technosphere RER 7.7125e-07 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, from natural gas technosphere AT 5.6804e-09 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, at cogen 1MWth, wood chips, allocation exergy technosphere CH 3.8947e-08 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, hydropower, at pumped storage power plant technosphere ES 8.3762e-09 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, hard coal, at power plant technosphere AT 2.5686e-09 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, industrial gas, at power plant technosphere ES 1.5652e-09 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, at wind farm technosphere RER 1.1860e-07 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, hydropower, at run-of-river power plant technosphere RER 4.1383e-07 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, nuclear, at power plant pressure water reactor technosphere DE 1.6257e-07 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, at cogen 300kWth, diesel, allocation exergy technosphere CH 1.9088e-09 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, production mix photovoltaic, at plant technosphere ES 7.1781e-08 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, at wind farm technosphere RER 9.8970e-08 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, at wind farm technosphere RER 8.6877e-08 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, nuclear, at power plant pressure water reactor technosphere CH 8.7878e-08 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, peat, at power plant technosphere NORDEL 1.0543e-09 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, at cogen 300kWth, diesel, allocation exergy technosphere CH 1.5036e-09 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, hydropower, at run-of-river power plant technosphere RER 2.9517e-07 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, hydropower, at pumped storage power plant technosphere IT 2.4692e-09 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, oil, at power plant technosphere IT 1.1103e-09 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, at cogen 300kWth, diesel, allocation exergy technosphere CH 1.3150e-09 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, at cogen with biogas engine, allocation exergy technosphere CH 5.6542e-09 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, from natural gas technosphere IT 1.8526e-09 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, from natural gas technosphere ES 1.4984e-09 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, at cogen 300kWth, diesel, allocation exergy technosphere CH 1.0113e-09 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, at cogen 1MWth, wood chips, allocation exergy technosphere CH 1.0835e-08 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, hard coal, at power plant technosphere SK 6.3294e-10 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, hard coal, at power plant technosphere PT 5.9338e-10 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, oil, at power plant technosphere HU 6.4358e-10 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, industrial gas, at power plant technosphere AT 6.6327e-10 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, hard coal, at power plant technosphere SK 5.4425e-10 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, hydropower, at pumped storage power plant technosphere RS 4.7953e-10 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, hard coal, at power plant technosphere HR 4.8269e-10 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, oil, at power plant technosphere PT 5.1209e-10 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, nuclear, at power plant pressure water reactor technosphere FR 7.3464e-08 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, hydropower, at pumped storage power plant technosphere PT 2.0253e-09 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, at cogen with biogas engine, allocation exergy technosphere CH 2.8194e-09 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, hydropower, at pumped storage power plant technosphere IE 8.7759e-10 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, lignite, at power plant technosphere GR 3.4379e-10 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, industrial gas, at power plant technosphere IT 2.7561e-10 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, at wind farm technosphere CH 2.1380e-08 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, hydropower, at run-of-river power plant technosphere RER 9.8480e-08 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, hydropower, at run-of-river power plant technosphere RER 9.6744e-08 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, at cogen 1MWth, wood chips, allocation exergy technosphere CH 5.6525e-09 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, hydropower, at reservoir power plant technosphere CH 3.9562e-08 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, production mix photovoltaic, at plant technosphere IT 1.5056e-08 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, nuclear, at power plant pressure water reactor technosphere CH 2.1920e-08 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, from natural gas technosphere IT 6.1087e-10 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, hydropower, at pumped storage power plant technosphere SI 8.1453e-10 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, hydropower, at reservoir power plant technosphere CH 3.1407e-08 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, hard coal, at power plant technosphere SK 2.5563e-10 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, at cogen with biogas engine, allocation exergy technosphere CH 1.5354e-09 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, at cogen with biogas engine, allocation exergy technosphere CH 1.3561e-09 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, industrial gas, at power plant technosphere IT 1.5621e-10 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, at cogen with biogas engine, allocation exergy technosphere CH 1.3151e-09 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, hydropower, at run-of-river power plant technosphere RER 5.9081e-08 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, at cogen 300kWth, diesel, allocation exergy technosphere CH 2.8943e-10 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, hydropower, at pumped storage power plant technosphere RO 5.3849e-10 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, nuclear, at power plant boiling water reactor technosphere CH 1.2721e-08 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, oil, at power plant technosphere IE 2.0052e-10 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, at cogen 1MWth, wood chips, allocation exergy technosphere CH 3.0030e-09 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, at cogen 1MWth, wood chips, allocation exergy technosphere CH 2.9469e-09 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, hydropower, at run-of-river power plant technosphere RER 4.7613e-08 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, production mix photovoltaic, at plant technosphere AT 6.2136e-09 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, from natural gas technosphere IT 3.5266e-10 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, at wind farm technosphere RER 1.2288e-08 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, oil, at power plant technosphere HR 1.6314e-10 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, industrial gas, at power plant technosphere AT 1.8221e-10 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, at cogen 300kWth, diesel, allocation exergy technosphere CH 2.2110e-10 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, at wind farm technosphere RER 1.1378e-08 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, hydropower, at reservoir power plant technosphere CH 1.7099e-08 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, hydropower, at run-of-river power plant technosphere RER 3.8842e-08 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, production mix photovoltaic, at plant technosphere HU 5.4089e-09 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, hydropower, at reservoir power plant technosphere CH 1.5327e-08 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, hydropower, at pumped storage power plant technosphere BG 1.6499e-10 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, production mix photovoltaic, at plant technosphere IE 3.5051e-09 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, hydropower, at pumped storage power plant technosphere HR 2.7342e-10 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, at cogen 1MWth, wood chips, allocation exergy technosphere CH 1.9002e-09 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, nuclear, at power plant pressure water reactor technosphere DE 1.2486e-08 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, at cogen 1MWth, wood chips, allocation exergy technosphere CH 1.8803e-09 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, oil, at power plant technosphere GR 1.1593e-10 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, production mix photovoltaic, at plant technosphere GR 5.0183e-09 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, at wind farm technosphere RER 7.2874e-09 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, at wind farm technosphere RER 7.2133e-09 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, lignite, at power plant technosphere GR 7.8905e-11 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, at cogen 300kWth, diesel, allocation exergy technosphere CH 1.2044e-10 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, hydropower, at pumped storage power plant technosphere BA 6.6164e-11 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, oil, at power plant technosphere BE 8.1048e-11 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, hydropower, at run-of-river power plant technosphere RER 2.0964e-08 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, at cogen 1MWth, wood chips, allocation exergy technosphere CH 1.2367e-09 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, at wind farm technosphere RER 5.3149e-09 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, at cogen with biogas engine, allocation exergy technosphere CH 4.2372e-10 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, industrial gas, at power plant technosphere IT 4.7479e-11 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, from natural gas technosphere IT 1.3455e-10 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, hydropower, at run-of-river power plant technosphere RER 1.6764e-08 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, oil, at power plant technosphere HR 5.4592e-11 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, hydropower, at reservoir power plant technosphere CH 6.3295e-09 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, at cogen 300kWth, diesel, allocation exergy technosphere CH 7.2139e-11 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, at cogen 1MWth, wood chips, allocation exergy technosphere CH 8.5259e-10 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, hydropower, at reservoir power plant technosphere CH 5.9807e-09 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, from natural gas technosphere ES 9.3109e-11 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, hydropower, at run-of-river power plant technosphere RER 1.3846e-08 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, lignite, at power plant technosphere MK 4.1772e-11 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, at wind farm technosphere RER 3.0562e-09 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, at cogen 300kWth, diesel, allocation exergy technosphere CH 5.4257e-11 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, hydropower, at run-of-river power plant technosphere RER 1.0926e-08 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, oil, at power plant technosphere PT 3.9481e-11 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, hydropower, at reservoir power plant technosphere CH 4.1936e-09 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, oil, at power plant technosphere GR 3.4085e-11 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, at cogen with biogas engine, allocation exergy technosphere CH 1.8891e-10 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, at cogen with biogas engine, allocation exergy technosphere CH 1.8249e-10 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, oil, at power plant technosphere HU 3.2012e-11 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, from natural gas technosphere IT 6.0405e-11 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, at wind farm technosphere RER 1.8997e-09 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, hydropower, at reservoir power plant technosphere CH 2.9227e-09 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, industrial gas, at power plant technosphere IT 1.4872e-11 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, hydropower, at run-of-river power plant technosphere RER 5.6969e-09 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, at cogen 1MWth, wood chips, allocation exergy technosphere CH 3.3904e-10 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, hydropower, at run-of-river power plant technosphere RER 5.6232e-09 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, at cogen 1MWth, wood chips, allocation exergy technosphere CH 2.8685e-10 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, at cogen with biogas engine, allocation exergy technosphere CH 9.4769e-11 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, hydropower, at reservoir power plant technosphere CH 1.6986e-09 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, from natural gas technosphere IT 2.7920e-11 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, at wind farm technosphere RER 9.5764e-10 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, production mix photovoltaic, at plant technosphere HU 5.0490e-10 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, at cogen 300kWth, diesel, allocation exergy technosphere CH 1.6858e-11 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, hydropower, at run-of-river power plant technosphere RER 2.9457e-09 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, oil, at power plant technosphere GR 1.0849e-11 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, at cogen with biogas engine, allocation exergy technosphere CH 6.2122e-11 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, hydropower, at reservoir power plant technosphere CH 1.1405e-09 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, production mix photovoltaic, at plant technosphere HU 3.7626e-10 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, production mix photovoltaic, at plant technosphere PT 4.4075e-10 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, oil, at power plant technosphere HR 8.2283e-12 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, hydropower, at pumped storage power plant technosphere MA 7.8278e-12 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, at cogen with biogas engine, allocation exergy technosphere CH 3.8887e-11 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, at wind farm technosphere RER 4.4535e-10 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, hydropower, at run-of-river power plant technosphere RER 1.6521e-09 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, production mix photovoltaic, at plant technosphere GR 2.7600e-10 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, at wind farm technosphere RER 3.0683e-10 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, production mix photovoltaic, at plant technosphere TR 1.8938e-10 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, hydropower, at run-of-river power plant technosphere RER 9.3611e-10 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, at wind farm technosphere RER 2.2133e-10 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, hydropower, at pumped storage power plant technosphere GR 4.5460e-12 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, hydropower, at reservoir power plant technosphere CH 2.8177e-10 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, at wind farm technosphere RER 1.4307e-10 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, at cogen 1MWth, wood chips, allocation exergy technosphere CH 2.7847e-11 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, at wind farm technosphere RER 9.3490e-11 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, hydropower, at run-of-river power plant technosphere RER 2.8177e-10 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, production mix photovoltaic, at plant technosphere PT 4.6139e-11 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, at cogen 1MWth, wood chips, allocation exergy technosphere CH 1.3597e-11 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, at cogen with biogas engine, allocation exergy technosphere CH 4.3969e-12 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, at cogen 300kWth, diesel, allocation exergy technosphere CH 4.9483e-13 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, hydropower, at run-of-river power plant technosphere RER 9.4831e-11 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, at cogen with biogas engine, allocation exergy technosphere CH 8.7093e-13 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, production mix photovoltaic, at plant technosphere HU 5.4609e-12 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, at cogen 300kWth, diesel, allocation exergy technosphere CH 1.5286e-13 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, production mix photovoltaic, at plant technosphere GR 4.6843e-12 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, hydropower, at reservoir power plant technosphere CH 9.6463e-12 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, hydropower, at reservoir power plant technosphere CH 5.6390e-12 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, at wind farm technosphere RER 2.4053e-12 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, at cogen 1MWth, wood chips, allocation exergy technosphere CH 4.5015e-13 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, hydropower, at run-of-river power plant technosphere RER 5.6390e-12 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, oil, at power plant technosphere GR 8.5897e-15 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity, at cogen 300kWth, diesel, allocation exergy technosphere CH 3.9885e-15 kWh lognormal, GSD² 1.11 — 0.0 ·
Electricity from waste, at municipal waste incineration plant technosphere CH 0.0068179 kWh lognormal, GSD² 1.11 — -0.0 ·
Electricity from waste, at municipal waste incineration plant technosphere CH 0.0035848 kWh lognormal, GSD² 1.11 — -0.0 ·
Electricity from waste, at municipal waste incineration plant technosphere CH 0.0031577 kWh lognormal, GSD² 1.11 — -0.0 ·
Electricity from waste, at municipal waste incineration plant technosphere CH 0.0025462 kWh lognormal, GSD² 1.11 — -0.0 ·
Electricity from waste, at municipal waste incineration plant technosphere CH 6.1172e-04 kWh lognormal, GSD² 1.11 — -0.0 ·
Electricity from waste, at municipal waste incineration plant technosphere CH 9.4793e-05 kWh lognormal, GSD² 1.11 — -0.0 ·
Electricity from waste, at municipal waste incineration plant technosphere CH 3.8623e-05 kWh lognormal, GSD² 1.11 — -0.0 ·
Electricity from waste, at municipal waste incineration plant technosphere CH 2.1550e-05 kWh lognormal, GSD² 1.11 — -0.0 ·
Electricity from waste, at municipal waste incineration plant technosphere CH 1.2034e-05 kWh lognormal, GSD² 1.11 — -0.0 ·
Electricity from waste, at municipal waste incineration plant technosphere CH 2.5720e-06 kWh lognormal, GSD² 1.11 — -0.0 ·
Electricity from waste, at municipal waste incineration plant technosphere CH 6.7942e-07 kWh lognormal, GSD² 1.11 — -0.0 ·
Electricity from waste, at municipal waste incineration plant technosphere CH 3.3001e-07 kWh lognormal, GSD² 1.11 — -0.0 ·
Electricity from waste, at municipal waste incineration plant technosphere CH 3.0357e-07 kWh lognormal, GSD² 1.11 — -0.0 ·
Electricity from waste, at municipal waste incineration plant technosphere CH 2.8302e-07 kWh lognormal, GSD² 1.11 — -0.0 ·
Electricity from waste, at municipal waste incineration plant technosphere CH 2.7668e-07 kWh lognormal, GSD² 1.05 — -0.0 ·
Electricity from waste, at municipal waste incineration plant technosphere CH 2.7302e-07 kWh lognormal, GSD² 1.11 — -0.0 ·
Electricity from waste, at municipal waste incineration plant technosphere CH 1.4106e-07 kWh lognormal, GSD² 1.11 — -0.0 ·
Electricity from waste, at municipal waste incineration plant technosphere CH 9.1800e-09 kWh lognormal, GSD² 1.11 — -0.0 ·
Electricity from waste, at municipal waste incineration plant technosphere CH 5.6300e-09 kWh lognormal, GSD² 1.11 — -0.0 ·
Electricity from waste, at municipal waste incineration plant technosphere CH 5.5410e-09 kWh lognormal, GSD² 1.11 — -0.0 ·
Electricity from waste, at municipal waste incineration plant technosphere CH 2.7256e-09 kWh lognormal, GSD² 1.11 — -0.0 ·
Electricity from waste, at municipal waste incineration plant technosphere CH 2.6857e-09 kWh lognormal, GSD² 1.11 — -0.0 ·
Electricity from waste, at municipal waste incineration plant technosphere CH 1.8965e-10 kWh lognormal, GSD² 1.11 — -0.0 ·
Electricity from waste, at municipal waste incineration plant technosphere CH 1.7092e-10 kWh lognormal, GSD² 1.11 — -0.0 ·
Electricity from waste, at municipal waste incineration plant technosphere CH 1.3985e-10 kWh lognormal, GSD² 1.11 — -0.0 ·
Electricity from waste, at municipal waste incineration plant technosphere CH 5.9069e-12 kWh lognormal, GSD² 1.11 — -0.0 ·
Electricity from waste, at municipal waste incineration plant technosphere CH 5.0696e-12 kWh lognormal, GSD² 1.11 — -0.0 ·
Electricity from waste, at municipal waste incineration plant technosphere CH 4.7847e-13 kWh lognormal, GSD² 1.11 — -0.0 ·

Data quality

0 of 426 direct exchanges carry a declared pedigree, 426 carry a distribution.

Field As declared by the publisher
Data generator / entry / validation data generator: Christopher Oberschelp (ETH); data entry: Christopher Oberschelp (ETH); validation (proof reading): René Itten (ZHAW)
sampling procedure Statistical data
uncertainty adjustments none
validation details manual review of spold files and documentation
time period comment Time period of statistics used.

Data gaps, proxies and assumptions

None recorded.

Life cycle impact assessment (EF v3.1)

Per 1 kWh. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.

Impact category Indicator Unit Result 2.5 % 97.5 % GSD²
Acidification Accumulated Exceedance (AE) mol H+ eq 7.661e-04 6.950e-04 0.001363 1.38
Climate change-Biogenic Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.004221 0.001767 0.01227 2.68
Climate change-Fossil Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.2526 0.2289 0.3452 1.23
Climate change-Land use and land use change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 3.149e-05 2.791e-05 5.813e-05 1.44
Climate change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.2569 0.2336 0.3513 1.23
EF-particulate Matter Impact on human health disease incidence 1.115e-08 9.573e-09 1.798e-08 1.38
Ecotoxicity, freshwater_inorganics Comparative Toxic Unit for ecosystems (CTUe) CTUe 0.8676 0.5246 3.539 2.75
Ecotoxicity, freshwater_organics Comparative Toxic Unit for ecosystems (CTUe) CTUe 0.02289 0.0142 0.0943 2.6
Ecotoxicity, freshwater Comparative Toxic Unit for ecosystems (CTUe) CTUe 0.8905 0.5398 3.61 2.73
Eutrophication marine Fraction of nutrients reaching marine end compartment (N) kg N eq 2.385e-04 2.017e-04 5.419e-04 1.61
Eutrophication, freshwater Fraction of nutrients reaching freshwater end compartment (P) kg P eq 7.949e-05 4.503e-05 2.711e-04 2.51
Eutrophication, terrestrial Accumulated Exceedance (AE) mol N eq 0.001794 0.001449 0.004975 1.83
Human toxicity, cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 2.539e-11 2.710e-11 8.304e-11 1.78
Human toxicity, cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 3.821e-10 2.824e-10 5.668e-10 1.43
Human toxicity, cancer Comparative Toxic Unit for human (CTUh) CTUh 4.075e-10 3.222e-10 6.148e-10 1.39
Human toxicity, non-cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 1.409e-09 1.497e-09 3.800e-09 1.63
Human toxicity, non-cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 7.518e-11 6.778e-11 1.388e-10 1.44
Human toxicity, non-cancer Comparative Toxic Unit for human (CTUh) CTUh 1.484e-09 1.578e-09 3.900e-09 1.61
Ionising radiation, human health Human exposure efficiency relative to U235 kBq U235 eq 0.2712 0.07403 1.705 5.26
Land use Soil quality index pt (soil quality index) 9.084 5.617 15.91 1.68
Ozone depletion Ozone Depletion Potential (ODP) kg CFC-11 eq 1.005e-08 7.007e-09 2.224e-08 1.75
Photochemical ozone formation - human health Tropospheric ozone concentration increase kg NMVOC eq 8.654e-04 7.433e-04 0.001828 1.56
Resource use, fossils Abiotic resource depletion fossil fuels (ADP-fossil) MJ 5.569 4.807 9.601 1.42
Resource use, minerals and metals Abiotic resource depletion (ADP ultimate reserve) kg Sb eq 2.751e-07 2.631e-07 5.468e-07 1.45
Water use User deprivation potential (deprivation-weighted water consumption) m3 world eq deprived 0.04244 -136.6 71.07 —

Climate change 0.2569 kg CO2 eq per kWh. Main contributors: Electricity, oil, at power plant 31 %; Electricity, from natural gas 19 %; Electricity, industrial gas, at power plant 15 %; Electricity, hard coal, at power plant 7 %; Electricity, lignite, at power plant 4 %; Electricity, hard coal, at power plant 3 %.

Interpretation

Significant issues

Direct exchanges dominating climate change: Electricity, oil, at power plant 31 %; Electricity, from natural gas 19 %; Electricity, industrial gas, at power plant 15 %; Electricity, hard coal, at power plant 7 %; Electricity, lignite, at power plant 4 %; Electricity, hard coal, at power plant 3 %. Most sensitive exchanges (Section 6.3): Electricity, oil, at power plant [SE] (-3.1 / +3.4 %); Electricity, from natural gas [JP] (-1.9 / +2.1 %); Electricity, industrial gas, at power plant [DE] (-1.5 / +1.6 %).

Independent recalculation

Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh:

Category Graph Published Graph / published
Acidification 7.661e-04 9.593e-04 0.799
Climate change-Biogenic 0.004221 0.004221 1.000
Climate change-Fossil 0.2526 0.2526 1.000
Climate change-Land use and land use change 3.149e-05 3.149e-05 1.000
Climate change 0.2569 0.2569 1.000
EF-particulate Matter 1.115e-08 1.115e-08 1.000
Ecotoxicity, freshwater_inorganics 0.8676 0.8852 0.980
Ecotoxicity, freshwater_organics 0.02289 0.02266 1.010
Ecotoxicity, freshwater 0.8905 0.9075 0.981
Eutrophication marine 2.385e-04 2.385e-04 1.000
Eutrophication, freshwater 7.949e-05 7.949e-05 1.000
Eutrophication, terrestrial 0.001794 0.00242 0.741
Human toxicity, cancer_inorganics 2.539e-11 2.243e-11 1.132
Human toxicity, cancer_organics 3.821e-10 3.821e-10 1.000
Human toxicity, cancer 4.075e-10 4.046e-10 1.007
Human toxicity, non-cancer_inorganics 1.409e-09 1.339e-09 1.052
Human toxicity, non-cancer_organics 7.518e-11 7.515e-11 1.000
Human toxicity, non-cancer 1.484e-09 1.414e-09 1.049
Ionising radiation, human health 0.2712 0.2712 1.000
Land use 9.084 7.317 1.242
Ozone depletion 1.005e-08 1.005e-08 1.000
Photochemical ozone formation - human health 8.654e-04 8.654e-04 1.000
Resource use, fossils 5.569 5.637 0.988
Resource use, minerals and metals 2.751e-07 2.629e-07 1.046
Water use 0.04244 0.06274 0.676
Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like.
Also published by BAFU for this dataset: IPCC 2021 GWP100 0.2569 kg CO2 eq; Ecological Scarcity
2021 total 515.3 UBP.

Sensitivity check

One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.

Exchange Base Low / high Range Δ GWP100 (%) Δ other categories (max %)
Electricity, oil, at power plant [SE] 0.1187 kWh ×0.9 / ×1.11 lognormal, GSD² 1.11 -3.1 / +3.4 5.9 (Acidification)
Electricity, from natural gas [JP] 0.08464 kWh ×0.9 / ×1.11 lognormal, GSD² 1.11 -1.9 / +2.1 5.7 (Ecotoxicity, freshwater_organics)
Electricity, industrial gas, at power plant [DE] 0.03227 kWh ×0.9 / ×1.11 lognormal, GSD² 1.11 -1.5 / +1.6 4.4 (Human toxicity, cancer_organics)
Electricity, lignite, at power plant [PL] 0.01035 kWh ×0.9 / ×1.11 lognormal, GSD² 1.11 -0.4 / +0.5 4.1 (Eutrophication, freshwater)
Electricity, hard coal, at power plant [RU] 0.0169 kWh ×0.953 / ×1.05 lognormal, GSD² 1.05 -0.3 / +0.4 1.0 (EF-particulate Matter)
Electricity, hard coal, at power plant [PL] 0.006679 kWh ×0.9 / ×1.11 lognormal, GSD² 1.11 -0.3 / +0.3 0.8 (Human toxicity, non-cancer_inorganics)
Electricity, peat, at power plant [NORDEL] 0.005622 kWh ×0.9 / ×1.11 lognormal, GSD² 1.11 -0.2 / +0.3 0.3 (Acidification)
Electricity, at cogen 1MWth, wood chips, allocation exergy [CH] 0.06765 kWh ×0.9 / ×1.11 lognormal, GSD² 1.11 -0.2 / +0.2 6.5 (Land use)
Electricity, hard coal, at power plant [PL] 0.007544 kWh ×0.953 / ×1.05 lognormal, GSD² 1.05 -0.2 / +0.2 0.4 (Human toxicity, non-cancer_inorganics)
Electricity, from natural gas [DE] 0.007686 kWh ×0.9 / ×1.11 lognormal, GSD² 1.11 -0.1 / +0.2 0.2 (Ozone depletion)
Electricity, at cogen 1MWth, wood chips, allocation exergy [CH] 0.03438 kWh ×0.9 / ×1.11 lognormal, GSD² 1.11 -0.1 / +0.1 3.3 (Land use)
Electricity, industrial gas, at power plant [DE] 0.001648 kWh ×0.9 / ×1.11 lognormal, GSD² 1.11 -0.1 / +0.1 0.2 (Human toxicity, cancer_organics)
Electricity, lignite, at power plant [PL] 0.003903 kWh ×0.953 / ×1.05 lognormal, GSD² 1.05 -0.1 / +0.1 0.7 (Eutrophication, freshwater)
Electricity, industrial gas, at power plant [DE] 0.001327 kWh ×0.9 / ×1.11 lognormal, GSD² 1.11 -0.1 / +0.1 0.2 (Human toxicity, cancer_organics)
Electricity, hydropower, at reservoir power plant [FI] 0.03455 kWh ×0.9 / ×1.11 lognormal, GSD² 1.11 -0.1 / +0.1 3.5 (Climate change-Biogenic)

Uncertainty analysis

Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.

Comparison with other data

Source Scope Value This dataset Ratio Note
bafu Electricity imports [AR] 0.08781 kg CO2 eq 0.2569 2.93 same dataset name, other location
bafu Electricity imports [SE] 0.09689 kg CO2 eq 0.2569 2.65 same dataset name, other location
bafu Electricity imports [EE] 0.1084 kg CO2 eq 0.2569 2.37 same dataset name, other location
bafu Electricity imports [NO] 0.1095 kg CO2 eq 0.2569 2.35 same dataset name, other location
bafu Electricity imports [ES] 0.1131 kg CO2 eq 0.2569 2.27 same dataset name, other location
bafu Electricity imports [SK] 0.5444 kg CO2 eq 0.2569 0.47 same dataset name, other location
bafu Electricity imports [MY] 0.5889 kg CO2 eq 0.2569 0.44 same dataset name, other location
bafu Electricity imports [VN] 0.6978 kg CO2 eq 0.2569 0.37 same dataset name, other location
bafu Electricity imports [ID] 0.7298 kg CO2 eq 0.2569 0.35 same dataset name, other location
bafu Electricity imports [TH] 0.7298 kg CO2 eq 0.2569 0.35 same dataset name, other location

Conclusions and limitations

GWP100 0.2569 kg CO2 eq per kWh (95 % interval 0.2336–0.3513). Dominant contributors: Electricity, oil, at power plant 31 %; Electricity, from natural gas 19 %; Electricity, industrial gas, at power plant 15 %; Electricity, hard coal, at power plant 7 %; Electricity, lignite, at power plant 4 %; Electricity, hard coal, at power plant 3 %. Most sensitive: Electricity, oil, at power plant [SE] (-3.1 / +3.4 %); Electricity, from natural gas [JP] (-1.9 / +2.1 %); Electricity, industrial gas, at power plant [DE] (-1.5 / +1.6 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.

Final control

Item Status Detail
reference flow PASS production amount 1.0 kWh
closure: sum of direct contributions = dataset score (all 25 categories) PASS largest relative gap 1.8e-15
independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh (climate change) PASS graph / published = 1; categories within ±5 %: 19/25
every technosphere input of the EcoSpold delivery is in the graph PASS all present (bafu_links_check.py)
uncertainty declared on the direct exchanges PASS 426/426 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values
Monte Carlo 95 % interval contains the deterministic score PASS 0.2569 in [0.2336, 0.3513]
time period declared PASS 2023/2023
geography is a known location code PASS LV
sources cited PASS 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them

References

  1. Oberschelp C. (2025) 2025 - Electricity mixes in UVEK database - Oberschelp. Oberschelp Consulting — published source; as declared by BAFU (not found in OpenAlex/Crossref)
  2. Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — database; dataset citation
  3. International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva.
  4. Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. (tdc-doc method reference; title, version and year to verify against the user's copy)
  5. European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra.
  6. Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236

Annex — licence and terms of use

BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.