OpenData Wiki

Dataset documentation and review before publication

User Tools

Site Tools


datasets:bafu:1907244c-1647-4054-b5e9-429ca99b9b6a

Disposal, ventilation system, Altersheim Dorflinde — CH

Dataset documentation and final control (tdc-doc, imported mode)
Open this dataset in OpenData

Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Disposal, ventilation system, Altersheim Dorflinde [CH], per 1 p. EF v3.1 climate change 5137 kg CO2 eq (Monte Carlo 95 % interval 4782–6169). Main contributors: Disposal, ventilation unit 3500 m3/h, w. cross plate heat ex… 19 %; Disposal, ventilation unit 6700 m3/h, w. cross plate heat ex… 18 %; Disposal, ventilation unit 13000 m3/h, w. circuit connected … 12 %; Disposal, ventilation unit 6700 m3/h, w. circuit connected h… 10 %; Disposal, EI 30 fire insulation, 50mm, 120kg/m3, reinforced … 7 %; Disposal, ventilation duct, steel, zinc coated, s= 0.75mm 7 %. Status: final control passed.
Item Value
Dataset name Disposal, ventilation system, Altersheim Dorflinde
Dataset UUID / graph id 1907244c-1647-4054-b5e9-429ca99b9b6a / activity:disposal_ventilation_system_altersheim_dorflinde__ch
Reference product, unit Disposal, ventilation system, Altersheim Dorflinde, 1 p
Location CH — Specific to the technology mix encountered in sorting plants in Switzerland.
Time period 2014-01/2014-12
Category waste management / building demolition
Source database BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1
Publisher Swiss Federal Office for the Environment (FOEN/BAFU)
Background database BAFU 2026 v1 (graph bafuquery-db)
LCIA method EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix)
Status final control passed
Documented by tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17

Introduction

Disposal of a ventilation system for a residential care home with apartments, kitchen, cafe/restaurant, multi-purpose hall, wellness area and laundry. The inventory is based on a building with a total heated gross floor area of 9844 m2 and a total nominal air flow of 34460 m3/h, total weight of the components: 11910 kg/Unit, building with a specific air flow rate of 3.5 m3/h per m2 heated gross floor area. Data from call of bid including components for air handling units, ducts including insulation, air valves, roof-hoods, dampers, fire dampers, silencers. The data represent a ductwork mainly made of galvanized steel and includes air handling units mainly with heat recovery. System with central air handling units. Building without ground heat exchanger.; UUID: 1907244c-1647-4054-b5e9-429ca99b9b6a

This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.

Goal and scope

Function, functional unit and reference flow

Reference flow: 1 p of Disposal, ventilation system, Altersheim Dorflinde (CH). All results are given per unit of the reference flow.

System boundary

Transport to dismantling facilities, machines for handling in sorting plant, electricity demand for sorting plant, final disposal of waste material. Cut-off to recycling for metals.

Technology

Disposal to a sorting plant assumed. Metal pieces, copper in cables and electronic devices are recycled, plastic parts are incinerated, inert wastes (e.g. rock wool) are landfilled.

Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).

LCIA method

EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.

Life cycle inventory

Inventory table

Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).

Exchange Type Location / compartment Amount Unit Uncertainty Pedigree GWP share (%) Notes
Disposal, ventilation unit 3500 m3/h, w. cross plate heat excanger technosphere CH 3.223 p lognormal, GSD² 1.26 (3,4,1,1,1,5) 18.7 ████
Disposal, ventilation unit 6700 m3/h, w. cross plate heat excanger technosphere CH 1.775 p lognormal, GSD² 1.26 (3,4,1,1,1,5) 18.1 ████
Disposal, ventilation unit 13000 m3/h, w. circuit connected heat exchanger technosphere CH 0.751 p lognormal, GSD² 1.26 (3,4,1,1,1,5) 12.2 ██
Disposal, ventilation unit 6700 m3/h, w. circuit connected heat exchanger technosphere CH 0.996 p lognormal, GSD² 1.26 (3,4,1,1,1,5) 9.6 ██
Disposal, EI 30 fire insulation, 50mm, 120kg/m3, reinforced alumium foil technosphere CH 1463 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 7.1 █
Disposal, ventilation duct, steel, zinc coated, s= 0.75mm technosphere CH 1843.1 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 6.6 █
Disposal, ventilation system, Altersheim Dorflinde, various components technosphere CH 1 p lognormal, GSD² 1.24 (2,4,1,1,1,5) 5.9 █
Disposal, spiral-seam duct, steel, zinc coated, s= 0.5mm technosphere CH 763.94 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 4.9 █
Disposal, ventilation duct, steel, zinc coated, s= 1.0mm technosphere CH 1076.6 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 4.0 █
Disposal, ventilation duct, steel, zinc coated, s= 0.62mm technosphere CH 1085.7 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 3.8 █
Disposal, thermal insulation, 30mm, 40kg/m3, reinforced alumium foil technosphere CH 1110 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 3.5 █
Disposal, ventilation duct, steel, zinc coated, s= 0.87mm technosphere CH 794.03 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 2.9 █
Disposal, flexible duct, aluminum/PET, DN of 125 technosphere CH 242.34 m lognormal, GSD² 1.24 (2,4,1,1,1,5) 1.3 ·
Disposal, ventilation duct, steel, zinc coated, s= 1.25mm technosphere CH 158.27 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 0.6 ·
Disposal, spiral-seam duct, steel, zinc coated, s= 0.6mm technosphere CH 70.915 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 0.5 ·
Disposal, thermal insulation, 100mm, 40kg/m3, alumium cladding technosphere CH 80 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 0.1 ·
Disposal, ventilation system, Altersheim Dorflinde, special components technosphere CH 1 p lognormal, GSD² 1.24 (2,4,1,1,1,5) 0.1 ·
Disposal, spiral-seam duct, steel, zinc coated, s= 0.8mm technosphere CH 6.0319 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 0.0 ·
Disposal, ventilation duct, steel, zinc coated, s= 1.5mm technosphere CH 7.1175 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 0.0 ·
Disposal, spiral-seam duct, stainless steel, s= 0.8mm technosphere CH 1.885 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 0.0 ·

Data quality

20 of 20 direct exchanges carry a declared pedigree, 20 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 2.2 · completeness 4.0 · temporal 1.0 · geographical 1.0 · technological 1.0 · sample size 5.0.

Field As declared by the publisher
Data generator / entry / validation data generator: Alex Primas (HSLU); data entry: Alex Primas (HSLU); validation (proof reading): Alex Primas (HSLU)
extrapolations none
sampling procedure Waste-specific calculation based on production input data
production volume na
uncertainty adjustments none
time period comment Amount of material investigated in 2013. Disposal technology mix as used in late 1990ies

Data gaps, proxies and assumptions

None recorded.

Life cycle impact assessment (EF v3.1)

Per 1 p. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.

Impact category Indicator Unit Result 2.5 % 97.5 % GSD²
Acidification Accumulated Exceedance (AE) mol H+ eq 1.48 1.348 2.904 1.49
Climate change-Biogenic Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 1.085 0.874 2.075 1.56
Climate change-Fossil Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 5136 4780 6167 1.14
Climate change-Land use and land use change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.188 0.1634 0.2845 1.33
Climate change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 5137 4782 6169 1.14
EF-particulate Matter Impact on human health disease incidence 1.111e-04 7.343e-05 2.324e-04 1.79
Ecotoxicity, freshwater_inorganics Comparative Toxic Unit for ecosystems (CTUe) CTUe 2.026e+04 1.613e+04 3.188e+04 1.42
Ecotoxicity, freshwater_organics Comparative Toxic Unit for ecosystems (CTUe) CTUe 84.58 73.28 157.6 1.5
Ecotoxicity, freshwater Comparative Toxic Unit for ecosystems (CTUe) CTUe 2.035e+04 1.622e+04 3.199e+04 1.42
Eutrophication marine Fraction of nutrients reaching marine end compartment (N) kg N eq 1.699 1.393 3.652 1.66
Eutrophication, freshwater Fraction of nutrients reaching freshwater end compartment (P) kg P eq 0.8486 0.1541 25.4 14.6
Eutrophication, terrestrial Accumulated Exceedance (AE) mol N eq 12.03 9.595 27.95 1.76
Human toxicity, cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 2.406e-07 2.436e-07 9.832e-07 1.98
Human toxicity, cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 1.085e-07 9.598e-08 1.658e-07 1.33
Human toxicity, cancer Comparative Toxic Unit for human (CTUh) CTUh 3.492e-07 3.649e-07 1.103e-06 1.72
Human toxicity, non-cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 1.506e-05 1.495e-05 5.318e-05 1.92
Human toxicity, non-cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 8.565e-07 6.790e-07 1.331e-06 1.41
Human toxicity, non-cancer Comparative Toxic Unit for human (CTUh) CTUh 1.591e-05 1.570e-05 5.421e-05 1.88
Ionising radiation, human health Human exposure efficiency relative to U235 kBq U235 eq 184.4 70.96 1081 4.16
Land use Soil quality index pt (soil quality index) 7109 628.2 1.611e+04 —
Ozone depletion Ozone Depletion Potential (ODP) kg CFC-11 eq 2.011e-05 1.816e-05 3.322e-05 1.34
Photochemical ozone formation - human health Tropospheric ozone concentration increase kg NMVOC eq 4.692 3.87 9.944 1.62
Resource use, fossils Abiotic resource depletion fossil fuels (ADP-fossil) MJ 9030 8341 1.493e+04 1.32
Resource use, minerals and metals Abiotic resource depletion (ADP ultimate reserve) kg Sb eq 0.001232 0.00105 0.002433 1.53
Water use User deprivation potential (deprivation-weighted water consumption) m3 world eq deprived 671.5 -7.856e+04 4.082e+04 —

Climate change 5137 kg CO2 eq per p. Main contributors: Disposal, ventilation unit 3500 m3/h, w. cross plate heat ex… 19 %; Disposal, ventilation unit 6700 m3/h, w. cross plate heat ex… 18 %; Disposal, ventilation unit 13000 m3/h, w. circuit connected … 12 %; Disposal, ventilation unit 6700 m3/h, w. circuit connected h… 10 %; Disposal, EI 30 fire insulation, 50mm, 120kg/m3, reinforced … 7 %; Disposal, ventilation duct, steel, zinc coated, s= 0.75mm 7 %.

Interpretation

Significant issues

Direct exchanges dominating climate change: Disposal, ventilation unit 3500 m3/h, w. cross plate heat ex… 19 %; Disposal, ventilation unit 6700 m3/h, w. cross plate heat ex… 18 %; Disposal, ventilation unit 13000 m3/h, w. circuit connected … 12 %; Disposal, ventilation unit 6700 m3/h, w. circuit connected h… 10 %; Disposal, EI 30 fire insulation, 50mm, 120kg/m3, reinforced … 7 %; Disposal, ventilation duct, steel, zinc coated, s= 0.75mm 7 %. Most sensitive exchanges (Section 6.3): Disposal, ventilation unit 3500 m3/h, w. cross plate heat excanger [CH] (-3.8 / +4.8 %); Disposal, ventilation unit 6700 m3/h, w. cross plate heat excanger [CH] (-3.7 / +4.6 %); Disposal, ventilation unit 13000 m3/h, w. circuit connected heat exchanger [CH] (-2.5 / +3.1 %).

Independent recalculation

Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026):

Category Graph Published Graph / published
Acidification 1.48 3.18 0.465
Climate change-Biogenic 1.085 1.085 1.000
Climate change-Fossil 5136 5136 1.000
Climate change-Land use and land use change 0.188 0.188 1.000
Climate change 5137 5137 1.000
EF-particulate Matter 1.111e-04 1.111e-04 1.000
Ecotoxicity, freshwater_inorganics 2.026e+04 2.119e+04 0.956
Ecotoxicity, freshwater_organics 84.58 84.3 1.003
Ecotoxicity, freshwater 2.035e+04 2.127e+04 0.957
Eutrophication marine 1.699 1.699 1.000
Eutrophication, freshwater 0.8486 0.8486 1.000
Eutrophication, terrestrial 12.03 15.25 0.789
Human toxicity, cancer_inorganics 2.406e-07 2.398e-07 1.003
Human toxicity, cancer_organics 1.085e-07 1.085e-07 1.000
Human toxicity, cancer 3.492e-07 3.484e-07 1.002
Human toxicity, non-cancer_inorganics 1.506e-05 1.498e-05 1.005
Human toxicity, non-cancer_organics 8.565e-07 8.565e-07 1.000
Human toxicity, non-cancer 1.591e-05 1.583e-05 1.005
Ionising radiation, human health 184.4 184.4 1.000
Land use 7109 4209 1.689
Ozone depletion 2.011e-05 2.011e-05 1.000
Photochemical ozone formation - human health 4.692 4.692 1.000
Resource use, fossils 9030 9031 1.000
Resource use, minerals and metals 0.001232 0.001053 1.170
Water use 671.5 676.6 0.992
Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like.
Also published by BAFU for this dataset: IPCC 2021 GWP100 5137 kg CO2 eq; Ecological Scarcity
2021 total 9.335e+06 UBP.

Sensitivity check

One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.

Exchange Base Low / high Range Δ GWP100 (%) Δ other categories (max %)
Disposal, ventilation unit 3500 m3/h, w. cross plate heat excanger [CH] 3.223 p ×0.797 / ×1.25 lognormal, GSD² 1.26 -3.8 / +4.8 6.3 (Water use)
Disposal, ventilation unit 6700 m3/h, w. cross plate heat excanger [CH] 1.775 p ×0.797 / ×1.25 lognormal, GSD² 1.26 -3.7 / +4.6 6.6 (Water use)
Disposal, ventilation unit 13000 m3/h, w. circuit connected heat exchanger [CH] 0.751 p ×0.797 / ×1.25 lognormal, GSD² 1.26 -2.5 / +3.1 5.1 (Water use)
Disposal, ventilation unit 6700 m3/h, w. circuit connected heat exchanger [CH] 0.996 p ×0.797 / ×1.25 lognormal, GSD² 1.26 -1.9 / +2.4 3.6 (Water use)
Disposal, EI 30 fire insulation, 50mm, 120kg/m3, reinforced alumium foil [CH] 1463 m2 ×0.81 / ×1.23 lognormal, GSD² 1.24 -1.4 / +1.7 17.5 (Eutrophication, freshwater)
Disposal, ventilation duct, steel, zinc coated, s= 0.75mm [CH] 1843 m2 ×0.81 / ×1.23 lognormal, GSD² 1.24 -1.3 / +1.5 3.5 (Ionising radiation, human health)
Disposal, ventilation system, Altersheim Dorflinde, various components [CH] 1 p ×0.81 / ×1.23 lognormal, GSD² 1.24 -1.1 / +1.4 2.6 (Ionising radiation, human health)
Disposal, spiral-seam duct, steel, zinc coated, s= 0.5mm [CH] 763.9 m2 ×0.81 / ×1.23 lognormal, GSD² 1.24 -0.9 / +1.2 1.2 (Climate change-Fossil)
Disposal, ventilation duct, steel, zinc coated, s= 1.0mm [CH] 1077 m2 ×0.81 / ×1.23 lognormal, GSD² 1.24 -0.8 / +0.9 2.7 (Ionising radiation, human health)
Disposal, ventilation duct, steel, zinc coated, s= 0.62mm [CH] 1086 m2 ×0.81 / ×1.23 lognormal, GSD² 1.24 -0.7 / +0.9 1.7 (Ionising radiation, human health)
Disposal, thermal insulation, 30mm, 40kg/m3, reinforced alumium foil [CH] 1110 m2 ×0.81 / ×1.23 lognormal, GSD² 1.24 -0.7 / +0.8 2.7 (Eutrophication, freshwater)
Disposal, ventilation duct, steel, zinc coated, s= 0.87mm [CH] 794 m2 ×0.81 / ×1.23 lognormal, GSD² 1.24 -0.6 / +0.7 1.8 (Ionising radiation, human health)
Disposal, flexible duct, aluminum/PET, DN of 125 [CH] 242.3 m ×0.81 / ×1.23 lognormal, GSD² 1.24 -0.2 / +0.3 0.3 (Human toxicity, non-cancer_inorganics)
Disposal, ventilation duct, steel, zinc coated, s= 1.25mm [CH] 158.3 m2 ×0.81 / ×1.23 lognormal, GSD² 1.24 -0.1 / +0.1 0.5 (Ionising radiation, human health)
Disposal, spiral-seam duct, steel, zinc coated, s= 0.6mm [CH] 70.92 m2 ×0.81 / ×1.23 lognormal, GSD² 1.24 -0.1 / +0.1 0.1 (Climate change-Fossil)

Uncertainty analysis

Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.

Comparison with other data

No other location of this dataset in the graph.

Conclusions and limitations

GWP100 5137 kg CO2 eq per p (95 % interval 4782–6169). Dominant contributors: Disposal, ventilation unit 3500 m3/h, w. cross plate heat ex… 19 %; Disposal, ventilation unit 6700 m3/h, w. cross plate heat ex… 18 %; Disposal, ventilation unit 13000 m3/h, w. circuit connected … 12 %; Disposal, ventilation unit 6700 m3/h, w. circuit connected h… 10 %; Disposal, EI 30 fire insulation, 50mm, 120kg/m3, reinforced … 7 %; Disposal, ventilation duct, steel, zinc coated, s= 0.75mm 7 %. Most sensitive: Disposal, ventilation unit 3500 m3/h, w. cross plate heat excanger [CH] (-3.8 / +4.8 %); Disposal, ventilation unit 6700 m3/h, w. cross plate heat excanger [CH] (-3.7 / +4.6 %); Disposal, ventilation unit 13000 m3/h, w. circuit connected heat exchanger [CH] (-2.5 / +3.1 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.

Final control

Item Status Detail
reference flow PASS production amount 1.0 p
closure: sum of direct contributions = dataset score (all 25 categories) PASS largest relative gap 3.9e-16
independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) PASS graph / published = 1; categories within ±5 %: 21/25
every technosphere input of the EcoSpold delivery is in the graph PASS all present (bafu_links_check.py)
uncertainty declared on the direct exchanges PASS 20/20 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values
Monte Carlo 95 % interval contains the deterministic score PASS 5137 in [4782, 6169]
time period declared PASS 2014-01/2014-12
geography is a known location code PASS CH
sources cited PASS 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them

References

  1. Klingler M., Kasser U., Savi D., Primas A., Stettler Y., Gujer P. (2014) Ökobilanzdaten für Lüftungs- und Wärmeanlagen. Schlussbericht, BFE. Bundesamt für Energie (BFE). Bern. Type: Separate publication Source: Report First author: Klingler M. Other authors: Kasser U., Savi D., Primas A., Stettler Y., Gujer P. Year: 2014 Title of anthology: Schlussbericht, BFE Place of publication: Bern Publisher:… — published source; as declared by BAFU (not found in OpenAlex/Crossref)
  2. Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — database; dataset citation
  3. International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva.
  4. Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. (tdc-doc method reference; title, version and year to verify against the user's copy)
  5. European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra.
  6. Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236

Annex — licence and terms of use

BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.


To suggest a correction or a dataset that does not exist yet, use Propose a dataset.

datasets/bafu/1907244c-1647-4054-b5e9-429ca99b9b6a.txt · Last modified: by 127.0.0.1