Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Multi-Si wafer, ribbon, at plant [RER], per 1 m2. EF v3.1 climate change 35.68 kg CO2 eq (Monte Carlo 95 % interval 30.31–51.79). Main contributors: Silicon, production mix, photovoltaics, at plant 61 %; Electricity, medium voltage, production ENTSO-E, at grid 32 %; Argon, liquid, at plant 2 %; Polystyrene, high impact, HIPS, at plant 2 %. Status: final control passed.
Item Value
Dataset name Multi-Si wafer, ribbon, at plant
Dataset UUID / graph id 1e8b3a01-f432-34b4-94dc-2414479c676a / activity:multi_si_wafer_ribbon_at_plant__rer
Reference product, unit Multi-Si wafer, ribbon, at plant, 1 m2
Location RER — Europe, Western + North America
Time period 2005-01/2006-12
Category electronics / photovoltaic
Source database BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1
Publisher Swiss Federal Office for the Environment (FOEN/BAFU)
Background database BAFU 2026 v1 (graph bafuquery-db)
LCIA method EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix)
Status final control passed
Documented by tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17

Introduction

The reference flow for the life cycle inventory is 1 square metre of wafer surface. The ribbon silicon wafers have a wafer thickness of 250 um. The wafer area is 243cm2, thickness 250 um. The weight is 583 g/m2; Synonyms: polycrystalline, multi-crystalline, silicon; UUID: 1e8b3a01-f432-34b4-94dc-2414479c676a

This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.

Goal and scope

Function, functional unit and reference flow

Reference flow: 1 m2 of Multi-Si wafer, ribbon, at plant (RER). All results are given per unit of the reference flow.

System boundary

Sawing and cleaning of wafers. The process data include electricity use, water and working material consumption (e.g. stainless steel for saw-blades, argon gas, hydrofluoric and hydrochloric acid). Production wastes to be treated and process-specific NOx- and waterborne pollutants are considered. No data on other process specific air emissions.

Technology

Average from 3 specific processes of which one in pilot phase.

Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).

LCIA method

EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.

Life cycle inventory

Inventory table

Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).

Exchange Type Location / compartment Amount Unit Uncertainty Pedigree GWP share (%) Notes
Silicon, production mix, photovoltaics, at plant technosphere GLO 0.74 kg lognormal, GSD² 1.07 (1,2,1,1,1,3) 60.7 ████████████
Electricity, medium voltage, production ENTSO-E, at grid technosphere ENTSO-E 42.3 kWh lognormal, GSD² 2.07 (3,4,1,3,1,5) 32.5 ██████
Argon, liquid, at plant technosphere RER 5.21 kg lognormal, GSD² 1.26 (3,4,2,3,1,5) 2.4 ·
Polystyrene, high impact, HIPS, at plant technosphere RER 0.2 kg lognormal, GSD² 1.34 (4,4,3,3,1,5) 2.0 ·
Wafer factory technosphere DE 4.0000e-06 p lognormal, GSD² 3 (1,2,1,1,1,3) 0.8 ·
Packaging film, LDPE, at plant technosphere RER 0.1 kg lognormal, GSD² 1.34 (4,4,3,3,1,5) 0.8 ·
Paper, woodfree, coated, at integrated mill technosphere RER 0.19 kg lognormal, GSD² 1.29 (3,4,3,3,1,5) 0.5 ·
Transport, freight, lorry, fleet average technosphere RER 0.31366 tkm lognormal, GSD² 2.1 — 0.2 ·
Transport, freight, rail technosphere RER 0.81896 tkm lognormal, GSD² 2.1 — 0.0 ·
Disposal, waste, silicon wafer production, 0% water, to underground deposit technosphere DE 0.007 kg lognormal, GSD² 1.07 (1,2,1,1,1,3) 0.0 ·
Graphite, at plant technosphere RER 0.0066 kg lognormal, GSD² 1.07 (1,2,1,1,1,3) 0.0 ·
Chromium(3+) elementary water/River 3.0254e-05 kg lognormal, GSD² 3.06 (2,4,2,3,1,5) 0.0 ·
Mercury elementary water/River 6.0508e-06 kg lognormal, GSD² 5.07 (2,4,2,3,1,5) 0.0 ·
Chemical Oxygen Demand elementary water/Surface water 0.029555 kg lognormal, GSD² 1.58 (2,4,1,3,1,5) 0.0 ·
Lead elementary water/River 3.0254e-05 kg lognormal, GSD² 5.07 (2,4,2,3,1,5) 0.0 ·
Total Organic Carbon elementary water/River 0.011083 kg lognormal, GSD² 1.59 (3,4,2,3,1,5) 0.0 ·
Biological Oxygen Demand elementary water/River 0.029555 kg lognormal, GSD² 1.59 (2,4,1,3,1,5) 0.0 ·
Dinitrogen elementary water/River 0.0099449 kg lognormal, GSD² 1.58 (2,4,1,3,1,5) 0.0 ·
DOC, Dissolved Organic Carbon elementary water/River 0.011083 kg lognormal, GSD² 1.59 (3,4,2,3,1,5) 0.0 ·
Copper, ion elementary water/River 6.0508e-05 kg lognormal, GSD² 3.06 (2,4,2,3,1,5) 0.0 ·
Nickel(2+) elementary water/River 6.0508e-05 kg lognormal, GSD² 5.07 (2,4,2,3,1,5) 0.0 ·
Phosphate elementary water/River 5.0129e-04 kg lognormal, GSD² 1.58 (2,4,1,3,1,5) 0.0 ·
Adsorbable Organic Halogen Compounds elementary water/River 5.0129e-04 kg lognormal, GSD² 1.58 (2,4,1,3,1,5) 0.0 ·
Waste Heat elementary air/Ground level / Urban (>1000 people/s… 152.28 MJ lognormal, GSD² 1.26 (3,4,1,3,1,5) 0.0 ·
Cadmium(2+) elementary water/River 6.0508e-06 kg lognormal, GSD² 3.06 (2,4,2,3,1,5) 0.0 ·

Data quality

23 of 25 direct exchanges carry a declared pedigree, 25 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 2.26 · completeness 3.65 · temporal 1.65 · geographical 2.65 · technological 1.0 · sample size 4.65.

Field As declared by the publisher
Data generator / entry / validation data generator: Mariska J. de Wild-Scholten; data entry: Niels Jungbluth (ESU); validation (proof reading): Roberto Dones
extrapolations none
sampling procedure Data collection by factory representatives. Environmental report and LCA studies.
production volume na
uncertainty adjustments none
validation details Proof reading validation: 04.04.2012; Other validation: \server\e\ESU-Docs\Projekte laufend\407 Update LCI Energiesysteme\EcoSpold\Fotovoltaik[407_photovoltaics-v1.0.xlsx]X-Process;
time period comment Use of data from an environmental report of a production plant (ca. 3 million wafers per year) and some data from older publications.

Data gaps, proxies and assumptions

None recorded.

Life cycle impact assessment (EF v3.1)

Per 1 m2. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.

Impact category Indicator Unit Result 2.5 % 97.5 % GSD²
Acidification Accumulated Exceedance (AE) mol H+ eq 0.1126 0.0979 0.1526 1.26
Climate change-Biogenic Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.9027 0.5003 2.224 2.1
Climate change-Fossil Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 34.76 29.57 50.49 1.31
Climate change-Land use and land use change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.0141 0.01117 0.02387 1.48
Climate change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 35.68 30.31 51.79 1.31
EF-particulate Matter Impact on human health disease incidence 6.072e-07 5.241e-07 1.037e-06 1.4
Ecotoxicity, freshwater_inorganics Comparative Toxic Unit for ecosystems (CTUe) CTUe 113.7 98.04 226.5 1.54
Ecotoxicity, freshwater_organics Comparative Toxic Unit for ecosystems (CTUe) CTUe 3.819 3.408 6.241 1.38
Ecotoxicity, freshwater Comparative Toxic Unit for ecosystems (CTUe) CTUe 117.6 101.9 232.3 1.52
Eutrophication marine Fraction of nutrients reaching marine end compartment (N) kg N eq 0.02561 0.02207 0.03874 1.33
Eutrophication, freshwater Fraction of nutrients reaching freshwater end compartment (P) kg P eq 0.02149 0.01054 0.07992 2.82
Eutrophication, terrestrial Accumulated Exceedance (AE) mol N eq 0.1841 0.1588 0.2836 1.35
Human toxicity, cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 4.618e-09 4.698e-09 1.213e-08 1.63
Human toxicity, cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 2.237e-08 1.642e-08 4.030e-08 1.6
Human toxicity, cancer Comparative Toxic Unit for human (CTUh) CTUh 2.699e-08 2.197e-08 5.006e-08 1.52
Human toxicity, non-cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 2.501e-07 2.501e-07 6.447e-07 1.63
Human toxicity, non-cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 1.287e-08 1.179e-08 2.287e-08 1.44
Human toxicity, non-cancer Comparative Toxic Unit for human (CTUh) CTUh 2.630e-07 2.645e-07 6.620e-07 1.61
Ionising radiation, human health Human exposure efficiency relative to U235 kBq U235 eq 19.22 6.085 127.9 4.79
Land use Soil quality index pt (soil quality index) 310.6 247.6 512.7 1.46
Ozone depletion Ozone Depletion Potential (ODP) kg CFC-11 eq 1.761e-06 1.369e-06 3.122e-06 1.51
Photochemical ozone formation - human health Tropospheric ozone concentration increase kg NMVOC eq 0.08285 0.07281 0.1347 1.36
Resource use, fossils Abiotic resource depletion fossil fuels (ADP-fossil) MJ 599.4 480.2 1014 1.46
Resource use, minerals and metals Abiotic resource depletion (ADP ultimate reserve) kg Sb eq 6.991e-05 5.742e-05 1.544e-04 1.68
Water use User deprivation potential (deprivation-weighted water consumption) m3 world eq deprived 3.395 -2.373e+04 1.289e+04 —

Climate change 35.68 kg CO2 eq per m2. Main contributors: Silicon, production mix, photovoltaics, at plant 61 %; Electricity, medium voltage, production ENTSO-E, at grid 32 %; Argon, liquid, at plant 2 %; Polystyrene, high impact, HIPS, at plant 2 %.

Interpretation

Significant issues

Direct exchanges dominating climate change: Silicon, production mix, photovoltaics, at plant 61 %; Electricity, medium voltage, production ENTSO-E, at grid 32 %; Argon, liquid, at plant 2 %; Polystyrene, high impact, HIPS, at plant 2 %. Most sensitive exchanges (Section 6.3): Electricity, medium voltage, production ENTSO-E, at grid [ENTSO-E] (-16.6 / +33.9 %); Silicon, production mix, photovoltaics, at plant [GLO] (-4.1 / +4.4 %); Wafer factory [DE] (-0.5 / +1.6 %).

Independent recalculation

Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026):

Category Graph Published Graph / published
Acidification 0.1126 0.1014 1.110
Climate change-Biogenic 0.9027 0.9027 1.000
Climate change-Fossil 34.76 34.76 1.000
Climate change-Land use and land use change 0.0141 0.0141 1.000
Climate change 35.68 35.68 1.000
EF-particulate Matter 6.072e-07 6.072e-07 1.000
Ecotoxicity, freshwater_inorganics 113.7 115.9 0.981
Ecotoxicity, freshwater_organics 3.819 3.796 1.006
Ecotoxicity, freshwater 117.6 119.7 0.982
Eutrophication marine 0.02561 0.02561 1.000
Eutrophication, freshwater 0.02149 0.02149 1.000
Eutrophication, terrestrial 0.1841 0.2378 0.774
Human toxicity, cancer_inorganics 4.618e-09 4.228e-09 1.092
Human toxicity, cancer_organics 2.237e-08 2.237e-08 1.000
Human toxicity, cancer 2.699e-08 2.660e-08 1.015
Human toxicity, non-cancer_inorganics 2.501e-07 2.376e-07 1.052
Human toxicity, non-cancer_organics 1.287e-08 1.287e-08 1.000
Human toxicity, non-cancer 2.630e-07 2.505e-07 1.050
Ionising radiation, human health 19.22 19.22 1.000
Land use 310.6 232.1 1.338
Ozone depletion 1.761e-06 1.761e-06 1.000
Photochemical ozone formation - human health 0.08285 0.08285 1.000
Resource use, fossils 599.4 599.9 0.999
Resource use, minerals and metals 6.991e-05 4.635e-05 1.508
Water use 3.395 4.211 0.806
Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like.
Also published by BAFU for this dataset: IPCC 2021 GWP100 35.67 kg CO2 eq; Ecological Scarcity
2021 total 6.288e+04 UBP.

Sensitivity check

One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.

Exchange Base Low / high Range Δ GWP100 (%) Δ other categories (max %)
Electricity, medium voltage, production ENTSO-E, at grid [ENTSO-E] 42.3 kWh ×0.489 / ×2.04 lognormal, GSD² 2.07 -16.6 / +33.9 83.2 (Ionising radiation, human health)
Silicon, production mix, photovoltaics, at plant [GLO] 0.74 kg ×0.932 / ×1.07 lognormal, GSD² 1.07 -4.1 / +4.4 5.9 (Ozone depletion)
Wafer factory [DE] 4.000e-06 p ×0.34 / ×2.94 lognormal, GSD² 3 -0.5 / +1.6 20.9 (Resource use, minerals and metals)
Polystyrene, high impact, HIPS, at plant [RER] 0.2 kg ×0.748 / ×1.34 lognormal, GSD² 1.34 -0.5 / +0.7 1.7 (EF-particulate Matter)
Argon, liquid, at plant [RER] 5.21 kg ×0.795 / ×1.26 lognormal, GSD² 1.26 -0.5 / +0.6 1.5 (Ionising radiation, human health)
Packaging film, LDPE, at plant [RER] 0.1 kg ×0.748 / ×1.34 lognormal, GSD² 1.34 -0.2 / +0.3 7.0 (Human toxicity, cancer_organics)
Paper, woodfree, coated, at integrated mill [RER] 0.19 kg ×0.782 / ×1.28 lognormal, GSD² 1.29 -0.1 / +0.2 3.7 (Land use)
Transport, freight, lorry, fleet average [RER] 0.3137 tkm ×0.484 / ×2.06 lognormal, GSD² 2.1 -0.1 / +0.2 1.7 (Climate change-Land use and land use change)
Transport, freight, rail [RER] 0.819 tkm ×0.484 / ×2.06 lognormal, GSD² 2.1 -0.0 / +0.0 0.4 (Human toxicity, non-cancer_organics)
Disposal, waste, silicon wafer production, 0% water, to underground deposit [DE] 0.007 kg ×0.932 / ×1.07 lognormal, GSD² 1.07 -0.0 / +0.0 0.0 (EF-particulate Matter)
Graphite, at plant [RER] 0.0066 kg ×0.932 / ×1.07 lognormal, GSD² 1.07 -0.0 / +0.0 0.0 (Eutrophication, terrestrial)
Chromium(3+) [water/River] 3.025e-05 kg ×0.334 / ×2.99 lognormal, GSD² 3.06 -0.0 / +0.0 0.1 (Ecotoxicity, freshwater_inorganics)
Mercury [water/River] 6.051e-06 kg ×0.204 / ×4.91 lognormal, GSD² 5.07 -0.0 / +0.0 17.0 (Human toxicity, non-cancer_inorganics)
Lead [water/River] 3.025e-05 kg ×0.204 / ×4.91 lognormal, GSD² 5.07 -0.0 / +0.0 0.2 (Human toxicity, non-cancer_inorganics)
Copper, ion [water/River] 6.051e-05 kg ×0.334 / ×2.99 lognormal, GSD² 3.06 -0.0 / +0.0 0.0 (Ecotoxicity, freshwater_inorganics)

Uncertainty analysis

Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.

Comparison with other data

No other location of this dataset in the graph.

Conclusions and limitations

GWP100 35.68 kg CO2 eq per m2 (95 % interval 30.31–51.79). Dominant contributors: Silicon, production mix, photovoltaics, at plant 61 %; Electricity, medium voltage, production ENTSO-E, at grid 32 %; Argon, liquid, at plant 2 %; Polystyrene, high impact, HIPS, at plant 2 %. Most sensitive: Electricity, medium voltage, production ENTSO-E, at grid [ENTSO-E] (-16.6 / +33.9 %); Silicon, production mix, photovoltaics, at plant [GLO] (-4.1 / +4.4 %); Wafer factory [DE] (-0.5 / +1.6 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.

Final control

Item Status Detail
reference flow PASS production amount 1.0 m2
closure: sum of direct contributions = dataset score (all 25 categories) PASS largest relative gap 3.6e-16
independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) PASS graph / published = 1; categories within ±5 %: 18/25
every technosphere input of the EcoSpold delivery is in the graph PASS all present (bafu_links_check.py)
uncertainty declared on the direct exchanges PASS 25/25 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values
Monte Carlo 95 % interval contains the deterministic score PASS 35.68 in [30.31, 51.79]
time period declared PASS 2005-01/2006-12
geography is a known location code PASS RER
sources cited PASS 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them

References

  1. Jungbluth, N., Stucki M., Fluri K., Frischknecht R., Buesser S. (2012) Life Cycle Inventories of Photovoltaics. 0. Editors: Bauer C.. Volume: 407. ESU-services ltd.. Uster, CH. Type: Separate publication Source: www.esu-services.ch First author: Jungbluth, N. Other authors: Stucki M., Fluri K., Frischknecht R., Buesser S. Year: 2012 Name of editors: Bauer C. Title of anthology: 0 Place of publicat… — published source; as declared by BAFU (not found in OpenAlex/Crossref)
  2. Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — database; dataset citation
  3. International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva.
  4. Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. (tdc-doc method reference; title, version and year to verify against the user's copy)
  5. European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra.
  6. Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236

Annex — licence and terms of use

BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.


To suggest a correction or a dataset that does not exist yet, use Propose a dataset.

datasets/bafu/1e8b3a01-f432-34b4-94dc-2414479c676a.txt · Last modified: by 127.0.0.1