OpenData Wiki

Dataset documentation and review before publication

User Tools

Site Tools


datasets:bafu:2b7260d3-e923-3aa4-a3c1-d44f247af817

xxx Electricity, high voltage, residual mix — IT

Dataset documentation and final control (tdc-doc, imported mode)
Open this dataset in OpenData

Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset xxx Electricity, high voltage, residual mix [IT], per 1 kWh. EF v3.1 climate change 0.565 kg CO2 eq (Monte Carlo 95 % interval 0.5384–0.7445). Main contributors: xxx Electricity, residual mix 100 %. Status: final control passed.
Item Value
Dataset name xxx Electricity, high voltage, residual mix
Dataset UUID / graph id 2b7260d3-e923-3aa4-a3c1-d44f247af817 / activity:xxx_electricity_high_voltage_residual_mix__it
Reference product, unit xxx Electricity, high voltage, residual mix, 1 kWh
Location IT — undefined
Time period 2018-01/2018-12
Category electricity / notMaintained
Source database BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1
Publisher Swiss Federal Office for the Environment (FOEN/BAFU)
Background database BAFU 2026 v1 (graph bafuquery-db)
LCIA method EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix)
Status final control passed
Documented by tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17

Introduction

This dataset describes the transmission of high voltage electricity. Time period: Time of publications. Version: 1 Energy values: Undefined Local category: Elektrizität Local subcategory: Erzeugungsmix UVEK 2022 source file:726-Strommixe-EU_v0.8._X-Residual Mix Distribution.xml UUID: 2b7260d3-e923-3aa4-a3c1-d44f247af817

This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.

Goal and scope

Function, functional unit and reference flow

Reference flow: 1 kWh of xxx Electricity, high voltage, residual mix (IT). All results are given per unit of the reference flow.

System boundary

Included are the electricity production in IT, the transmission network and direct emissions to air (ozone and N2O). Electricity losses are accounted for.

Technology

undefined

Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).

LCIA method

EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.

Life cycle inventory

Inventory table

Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).

Exchange Type Location / compartment Amount Unit Uncertainty Pedigree GWP share (%) Notes
xxx Electricity, residual mix technosphere IT 1.024 kWh none declared: tdc-doc default ±50 % — 99.6 ████████████████████
Transmission network, electricity, high voltage technosphere CH 6.8199e-09 km lognormal, GSD² 3.28 — 0.2 ·
Nitrous Oxide elementary air/Unknown 5.0000e-06 kg lognormal, GSD² 1.85 — 0.2 ·
Waste Heat elementary air/Unknown 0.082069 MJ lognormal, GSD² 1.24 — 0.0 ·
Waste Heat elementary soil/Unknown 0.0043194 MJ lognormal, GSD² 1.24 — 0.0 ·
Ozone elementary air/Unknown 4.5000e-06 kg lognormal, GSD² 1.85 — 0.0 ·

Data quality

0 of 6 direct exchanges carry a declared pedigree, 5 carry a distribution.

Field As declared by the publisher
Data generator / entry / validation data generator: Luana Krebs (TREEZE); data entry: Luana Krebs (TREEZE); validation (proof reading): Rolf Frischknecht (TREEZE)
extrapolations
sampling procedure
production volume na
uncertainty adjustments none
validation details Proof reading validation: 10.02.2021; Other validation: G:\Projekte laufend\726 Umweltbilanz Strommix Schweiz 2018\EcoSpold[726-Strommixe-EU_v0.8.xlsx]X-Process;
time period comment Time of publications.

Data gaps, proxies and assumptions

Item Class Value used Reason Effect
1 exchange(s) without declared uncertainty uncertainty fixed in the Monte Carlo the publisher declares no distribution ±50 % in the sensitivity check (Section 6.3)

Life cycle impact assessment (EF v3.1)

Per 1 kWh. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.

Impact category Indicator Unit Result 2.5 % 97.5 % GSD²
Acidification Accumulated Exceedance (AE) mol H+ eq 5.751e-04 5.746e-04 8.591e-04 1.23
Climate change-Biogenic Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 2.523e-04 1.846e-04 9.423e-04 2.28
Climate change-Fossil Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.5646 0.538 0.7439 1.18
Climate change-Land use and land use change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 1.089e-04 7.948e-05 2.194e-04 1.66
Climate change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.565 0.5384 0.7445 1.18
EF-particulate Matter Impact on human health disease incidence 5.796e-09 5.883e-09 8.899e-09 1.24
Ecotoxicity, freshwater_inorganics Comparative Toxic Unit for ecosystems (CTUe) CTUe 1.533 1.321 4.282 1.84
Ecotoxicity, freshwater_organics Comparative Toxic Unit for ecosystems (CTUe) CTUe 0.02382 0.01921 0.08331 2.14
Ecotoxicity, freshwater Comparative Toxic Unit for ecosystems (CTUe) CTUe 1.556 1.345 4.35 1.84
Eutrophication marine Fraction of nutrients reaching marine end compartment (N) kg N eq 2.844e-04 2.838e-04 4.174e-04 1.23
Eutrophication, freshwater Fraction of nutrients reaching freshwater end compartment (P) kg P eq 2.834e-04 1.311e-04 9.266e-04 2.72
Eutrophication, terrestrial Accumulated Exceedance (AE) mol N eq 0.001445 0.001431 0.002539 1.35
Human toxicity, cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 4.588e-11 5.253e-11 1.450e-10 1.72
Human toxicity, cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 1.958e-11 1.944e-11 4.603e-11 1.56
Human toxicity, cancer Comparative Toxic Unit for human (CTUh) CTUh 6.546e-11 7.690e-11 1.747e-10 1.56
Human toxicity, non-cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 2.758e-09 2.811e-09 8.469e-09 1.76
Human toxicity, non-cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 1.143e-10 1.087e-10 2.458e-10 1.53
Human toxicity, non-cancer Comparative Toxic Unit for human (CTUh) CTUh 2.873e-09 2.931e-09 8.728e-09 1.74
Ionising radiation, human health Human exposure efficiency relative to U235 kBq U235 eq 0.1932 0.06761 1.156 4.28
Land use Soil quality index pt (soil quality index) 0.6545 0.6481 1.322 1.45
Ozone depletion Ozone Depletion Potential (ODP) kg CFC-11 eq 1.118e-08 9.375e-09 3.002e-08 1.81
Photochemical ozone formation - human health Tropospheric ozone concentration increase kg NMVOC eq 9.075e-04 8.544e-04 0.001759 1.47
Resource use, fossils Abiotic resource depletion fossil fuels (ADP-fossil) MJ 9.09 8.168 18.21 1.51
Resource use, minerals and metals Abiotic resource depletion (ADP ultimate reserve) kg Sb eq 2.208e-07 2.251e-07 5.184e-07 1.55
Water use User deprivation potential (deprivation-weighted water consumption) m3 world eq deprived 0.04863 -52.89 26.72 —

Climate change 0.565 kg CO2 eq per kWh. Main contributors: xxx Electricity, residual mix 100 %.

Interpretation

Significant issues

Direct exchanges dominating climate change: xxx Electricity, residual mix 100 %. Most sensitive exchanges (Section 6.3): xxx Electricity, residual mix [IT] (-49.8 / +49.8 %); Transmission network, electricity, high voltage [CH] (-0.1 / +0.4 %); Nitrous Oxide [air/Unknown] (-0.1 / +0.2 %).

Independent recalculation

Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh:

Category Graph Published Graph / published
Acidification 5.751e-04 0.001207 0.476
Climate change-Biogenic 2.523e-04 2.490e-04 1.013
Climate change-Fossil 0.5646 0.5637 1.002
Climate change-Land use and land use change 1.089e-04 1.086e-04 1.003
Climate change 0.565 0.5641 1.002
EF-particulate Matter 5.796e-09 5.772e-09 1.004
Ecotoxicity, freshwater_inorganics 1.533 1.557 0.984
Ecotoxicity, freshwater_organics 0.02382 0.02384 0.999
Ecotoxicity, freshwater 1.556 1.581 0.985
Eutrophication marine 2.844e-04 2.832e-04 1.004
Eutrophication, freshwater 2.834e-04 2.833e-04 1.000
Eutrophication, terrestrial 0.001445 0.002392 0.604
Human toxicity, cancer_inorganics 4.588e-11 3.837e-11 1.196
Human toxicity, cancer_organics 1.958e-11 1.944e-11 1.007
Human toxicity, cancer 6.546e-11 5.780e-11 1.132
Human toxicity, non-cancer_inorganics 2.758e-09 2.528e-09 1.091
Human toxicity, non-cancer_organics 1.143e-10 1.152e-10 0.992
Human toxicity, non-cancer 2.873e-09 2.643e-09 1.087
Ionising radiation, human health 0.1932 0.193 1.001
Land use 0.6545 0.6343 1.032
Ozone depletion 1.118e-08 1.111e-08 1.007
Photochemical ozone formation - human health 9.075e-04 9.132e-04 0.994
Resource use, fossils 9.09 9.071 1.002
Resource use, minerals and metals 2.208e-07 2.029e-07 1.088
Water use 0.04863 0.06102 0.797
Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like.
Also published by BAFU for this dataset: IPCC 2021 GWP100 0.564 kg CO2 eq; Ecological Scarcity
2021 total 784.7 UBP.

Sensitivity check

One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.

Exchange Base Low / high Range Δ GWP100 (%) Δ other categories (max %)
xxx Electricity, residual mix [IT] 1.024 kWh ×0.5 / ×1.5 none declared: tdc-doc default ±50 % -49.8 / +49.8 49.9 (Ozone depletion)
Transmission network, electricity, high voltage [CH] 6.820e-09 km ×0.312 / ×3.21 lognormal, GSD² 3.28 -0.1 / +0.4 36.1 (Resource use, minerals and metals)
Nitrous Oxide [air/Unknown] 5.000e-06 kg ×0.546 / ×1.83 lognormal, GSD² 1.85 -0.1 / +0.2 0.2 (Climate change-Fossil)

Uncertainty analysis

Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.

Comparison with other data

Source Scope Value This dataset Ratio Note
bafu xxx Electricity, high voltage, residual mix [AT] 0.002448 kg CO2 eq 0.565 230.80 same dataset name, other location
bafu xxx Electricity, high voltage, residual mix [FR] 0.07008 kg CO2 eq 0.565 8.06 same dataset name, other location
bafu xxx Electricity, high voltage, residual mix [SE] 0.07284 kg CO2 eq 0.565 7.76 same dataset name, other location
bafu xxx Electricity, high voltage, residual mix [SK] 0.2227 kg CO2 eq 0.565 2.54 same dataset name, other location
bafu xxx Electricity, high voltage, residual mix [BE] 0.2461 kg CO2 eq 0.565 2.30 same dataset name, other location
bafu xxx Electricity, high voltage, residual mix [CZ] 0.6781 kg CO2 eq 0.565 0.83 same dataset name, other location
bafu xxx Electricity, high voltage, residual mix [MT] 0.7874 kg CO2 eq 0.565 0.72 same dataset name, other location
bafu xxx Electricity, high voltage, residual mix [DE] 0.8 kg CO2 eq 0.565 0.71 same dataset name, other location
bafu xxx Electricity, high voltage, residual mix [CY] 0.9122 kg CO2 eq 0.565 0.62 same dataset name, other location
bafu xxx Electricity, high voltage, residual mix [PL] 1.009 kg CO2 eq 0.565 0.56 same dataset name, other location

Conclusions and limitations

GWP100 0.565 kg CO2 eq per kWh (95 % interval 0.5384–0.7445). Dominant contributors: xxx Electricity, residual mix 100 %. Most sensitive: xxx Electricity, residual mix [IT] (-49.8 / +49.8 %); Transmission network, electricity, high voltage [CH] (-0.1 / +0.4 %); Nitrous Oxide [air/Unknown] (-0.1 / +0.2 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.

Final control

Item Status Detail
reference flow PASS production amount 1.0 kWh
closure: sum of direct contributions = dataset score (all 25 categories) PASS largest relative gap 3.9e-16
independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh (climate change) PASS graph / published = 1.002; categories within ±5 %: 17/25
every technosphere input of the EcoSpold delivery is in the graph PASS all present (bafu_links_check.py)
uncertainty declared on the direct exchanges PASS 5/6 exchanges carry a distribution (83 %); the others enter the Monte Carlo as fixed values
Monte Carlo 95 % interval contains the deterministic score PASS 0.565 in [0.5384, 0.7445]
time period declared PASS 2018-01/2018-12
geography is a known location code PASS IT
sources cited PASS 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them

References

  1. Krebs L., Stolz P., Frischknecht R. (2020) Umweltbilanz Strommix Schweiz 2018. Project reports. Volume: 723. treeze Ltd.. Uster, CH. Type: Separate publication First author: Krebs L. Other authors: Stolz P., Frischknecht R. Year: 2020 Title of anthology: Project reports Place of publication: Uster, CH Publisher: treeze Ltd. Volume No: 723 — published source; as declared by BAFU (not found in OpenAlex/Crossref)
  2. Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — database; dataset citation
  3. International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva.
  4. Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. (tdc-doc method reference; title, version and year to verify against the user's copy)
  5. European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra.
  6. Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236

Annex — licence and terms of use

BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.


To suggest a correction or a dataset that does not exist yet, use Propose a dataset.

datasets/bafu/2b7260d3-e923-3aa4-a3c1-d44f247af817.txt · Last modified: by 127.0.0.1