Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset 3kWp facade installation, single-Si, panel, mounted, at building [APAC], per 1 p. EF v3.1 climate change 2873 kg CO2 eq (Monte Carlo 95 % interval 1865–8650). Main contributors: Photovoltaic panel, single-Si, at regional storage 60 %; Inverter, 2.5 kW, average, at plant 22 %; Facade construction, mounted, at building 11 %; Electric installation, photovoltaic plant, at plant 4 %; Treatment, c-Si PV module 2 %. Status: final control passed.
Item Value
Dataset name 3kWp facade installation, single-Si, panel, mounted, at building
Dataset UUID / graph id 3a39e02f-f7db-4ff8-bf59-cf40f7967bc5 / activity:3kwp_facade_installation_single_si_panel_mounted_at_building__apac
Reference product, unit 3kWp facade installation, single-Si, panel, mounted, at building, 1 p
Location APAC — Installation in Asia and Pacific.
Time period 2000-01/2000-12
Category photovoltaic / production of components
Source database BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1
Publisher Swiss Federal Office for the Environment (FOEN/BAFU)
Background database BAFU 2026 v1 (graph bafuquery-db)
LCIA method EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix)
Status final control passed
Documented by tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17

Introduction

Photovoltaic installation with a capacity of 3kWp and a life time of 30 years installed in Asia and Pacific. The efficiency of single-Si PV modules is 17.9% (Fraunhofer ISE Photovoltaics Report 2019). The share of rejected or replaced PV modules is estimated at 3%. The inverter is assumed to be replaced once during the service life of the PV system.; Synonyms: monocrystalline, single crystalline, silicon; UUID: 3a39e02f-f7db-4ff8-bf59-cf40f7967bc5

This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.

Goal and scope

Function, functional unit and reference flow

Reference flow: 1 p of 3kWp facade installation, single-Si, panel, mounted, at building (APAC). All results are given per unit of the reference flow.

System boundary

All components for the installation of a 3kWp photovoltaic plant, energy use for the mounting, transport of materials and persons to the construction place. Disposal of components after end of life.

Technology

Current technology for mounting of panels or laminates, electric installations and other components.

Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).

LCIA method

EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.

Life cycle inventory

Inventory table

Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).

Exchange Type Location / compartment Amount Unit Uncertainty Pedigree GWP share (%) Notes
Photovoltaic panel, single-Si, at regional storage technosphere APAC 15.846 m2 lognormal, GSD² 1.36 (3,4,3,1,1,5) 60.4 ████████████
Inverter, 2.5 kW, average, at plant technosphere RER 2.4 p lognormal, GSD² 1.24 — 22.1 ████
Facade construction, mounted, at building technosphere RER 15.385 m2 lognormal, GSD² 1.23 — 10.6 ██
Electric installation, photovoltaic plant, at plant technosphere CH 1 p lognormal, GSD² 2.09 (3,4,3,1,1,5) 4.4 █
Treatment, c-Si PV module technosphere RER 208.39 kg lognormal, GSD² 1.28 (3,4,3,1,1,5) 2.0 ·
Transport, freight, lorry, 7.5t-16t gross weight, fleet average technosphere RER 33.686 tkm lognormal, GSD² 2.09 (3,4,3,1,1,5) 0.5 ·
Electricity, low voltage, at grid technosphere JP 0.04 kWh lognormal, GSD² 1.28 (3,4,3,1,1,5) 0.0 ·
Waste Heat elementary air/Ground level / Urban (>1000 people/s… 0.144 MJ lognormal, GSD² 1.28 (3,4,3,1,1,5) 0.0 ·

Data quality

6 of 8 direct exchanges carry a declared pedigree, 8 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 3.0 · completeness 4.0 · temporal 3.0 · geographical 1.0 · technological 1.0 · sample size 5.0.

Field As declared by the publisher
Data generator / entry / validation data generator: Philippe Stolz (TREEZE); data entry: Philippe Stolz (TREEZE); validation (proof reading): Rolf Frischknecht (TREEZE)
extrapolations Estimations for lifetime of PV modules (30a) and inverters (15a) as well as for transport distances. Modules are assumed to be produced in Asia and Pacific.
sampling procedure Publication for efficiency, mounting systems and own estimations for other components.
production volume Total installed capacity in 2018: approximately 130 GWp in Asia and Pacific.
uncertainty adjustments
validation details Proof reading validation: 30.09.2020; Other validation: G:\Projekte laufend\174 Photovoltaic, IEA Task 12\2017 Global supply chain\EcoSpold[174-photovoltaics-global-supply-chain-v2.5.xlsx]X-Process;
time period comment Average module efficiency in 2018.

Data gaps, proxies and assumptions

None recorded.

Life cycle impact assessment (EF v3.1)

Per 1 p. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.

Impact category Indicator Unit Result 2.5 % 97.5 % GSD²
Acidification Accumulated Exceedance (AE) mol H+ eq 13.03 9.651 31.03 1.79
Climate change-Biogenic Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 12.05 5.469 49.57 3.03
Climate change-Fossil Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 2860 1854 8595 2.15
Climate change-Land use and land use change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 1.601 1.117 3.896 1.89
Climate change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 2873 1865 8650 2.15
EF-particulate Matter Impact on human health disease incidence 1.032e-04 7.617e-05 5.882e-04 2.72
Ecotoxicity, freshwater_inorganics Comparative Toxic Unit for ecosystems (CTUe) CTUe 1.974e+04 1.34e+04 7.898e+04 2.45
Ecotoxicity, freshwater_organics Comparative Toxic Unit for ecosystems (CTUe) CTUe 376 292.9 1053 2.01
Ecotoxicity, freshwater Comparative Toxic Unit for ecosystems (CTUe) CTUe 2.012e+04 1.37e+04 7.981e+04 2.43
Eutrophication marine Fraction of nutrients reaching marine end compartment (N) kg N eq 4.006 2.477 14.34 2.41
Eutrophication, freshwater Fraction of nutrients reaching freshwater end compartment (P) kg P eq 4.286 2.652 26.02 3.25
Eutrophication, terrestrial Accumulated Exceedance (AE) mol N eq 26.09 18.85 76.46 2.04
Human toxicity, cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 1.676e-06 1.491e-06 5.743e-06 1.98
Human toxicity, cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 8.075e-07 5.251e-07 2.540e-06 2.3
Human toxicity, cancer Comparative Toxic Unit for human (CTUh) CTUh 2.483e-06 2.142e-06 8.062e-06 1.95
Human toxicity, non-cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 1.117e-04 9.777e-05 3.636e-04 1.94
Human toxicity, non-cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 5.220e-06 3.671e-06 1.060e-05 1.75
Human toxicity, non-cancer Comparative Toxic Unit for human (CTUh) CTUh 1.170e-04 1.029e-04 3.698e-04 1.91
Ionising radiation, human health Human exposure efficiency relative to U235 kBq U235 eq 843.7 218.7 6772 5.81
Land use Soil quality index pt (soil quality index) 2.089e+04 1.4e+04 6.826e+04 2.2
Ozone depletion Ozone Depletion Potential (ODP) kg CFC-11 eq 1.098e-04 7.618e-05 3.156e-04 2.07
Photochemical ozone formation - human health Tropospheric ozone concentration increase kg NMVOC eq 9.239 6.981 25.83 1.95
Resource use, fossils Abiotic resource depletion fossil fuels (ADP-fossil) MJ 3.997e+04 2.606e+04 1.276e+05 2.21
Resource use, minerals and metals Abiotic resource depletion (ADP ultimate reserve) kg Sb eq 0.4857 0.3675 0.7511 1.46
Water use User deprivation potential (deprivation-weighted water consumption) m3 world eq deprived 2372 -6.868e+05 4.363e+05 —

Climate change 2873 kg CO2 eq per p. Main contributors: Photovoltaic panel, single-Si, at regional storage 60 %; Inverter, 2.5 kW, average, at plant 22 %; Facade construction, mounted, at building 11 %; Electric installation, photovoltaic plant, at plant 4 %; Treatment, c-Si PV module 2 %.

Interpretation

Significant issues

Direct exchanges dominating climate change: Photovoltaic panel, single-Si, at regional storage 60 %; Inverter, 2.5 kW, average, at plant 22 %; Facade construction, mounted, at building 11 %; Electric installation, photovoltaic plant, at plant 4 %; Treatment, c-Si PV module 2 %. Most sensitive exchanges (Section 6.3): Photovoltaic panel, single-Si, at regional storage [APAC] (-15.6 / +21.1 %); Inverter, 2.5 kW, average, at plant [RER] (-4.1 / +5.1 %); Electric installation, photovoltaic plant, at plant [CH] (-2.2 / +4.6 %).

Independent recalculation

Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026):

Category Graph Published Graph / published
Acidification 13.03 13.93 0.936
Climate change-Biogenic 12.05 12.05 1.000
Climate change-Fossil 2860 2860 1.000
Climate change-Land use and land use change 1.601 1.601 1.000
Climate change 2873 2873 1.000
EF-particulate Matter 1.032e-04 1.032e-04 1.000
Ecotoxicity, freshwater_inorganics 1.974e+04 2.032e+04 0.972
Ecotoxicity, freshwater_organics 376 318.9 1.179
Ecotoxicity, freshwater 2.012e+04 2.05e+04 0.981
Eutrophication marine 4.006 4.006 1.000
Eutrophication, freshwater 4.286 4.286 1.000
Eutrophication, terrestrial 26.09 27.04 0.965
Human toxicity, cancer_inorganics 1.676e-06 1.667e-06 1.005
Human toxicity, cancer_organics 8.075e-07 8.074e-07 1.000
Human toxicity, cancer 2.483e-06 2.474e-06 1.004
Human toxicity, non-cancer_inorganics 1.117e-04 1.111e-04 1.006
Human toxicity, non-cancer_organics 5.220e-06 5.218e-06 1.000
Human toxicity, non-cancer 1.170e-04 1.163e-04 1.005
Ionising radiation, human health 843.7 843.7 1.000
Land use 2.089e+04 1.715e+04 1.218
Ozone depletion 1.098e-04 1.098e-04 1.000
Photochemical ozone formation - human health 9.239 9.239 1.000
Resource use, fossils 3.997e+04 3.998e+04 1.000
Resource use, minerals and metals 0.4857 0.4841 1.003
Water use 2372 2176 1.090
Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like.
Also published by BAFU for this dataset: IPCC 2021 GWP100 2870 kg CO2 eq; Ecological Scarcity
2021 total 7.494e+06 UBP.

Sensitivity check

One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.

Exchange Base Low / high Range Δ GWP100 (%) Δ other categories (max %)
Photovoltaic panel, single-Si, at regional storage [APAC] 15.85 m2 ×0.741 / ×1.35 lognormal, GSD² 1.36 -15.6 / +21.1 32.8 (Water use)
Inverter, 2.5 kW, average, at plant [RER] 2.4 p ×0.813 / ×1.23 lognormal, GSD² 1.24 -4.1 / +5.1 18.8 (Resource use, minerals and metals)
Electric installation, photovoltaic plant, at plant [CH] 1 p ×0.486 / ×2.06 lognormal, GSD² 2.09 -2.2 / +4.6 49.4 (Human toxicity, non-cancer_organics)
Facade construction, mounted, at building [RER] 15.38 m2 ×0.817 / ×1.22 lognormal, GSD² 1.23 -1.9 / +2.4 5.1 (Climate change-Land use and land use change)
Treatment, c-Si PV module [RER] 208.4 kg ×0.782 / ×1.28 lognormal, GSD² 1.28 -0.4 / +0.6 1.2 (Climate change-Land use and land use change)
Transport, freight, lorry, 7.5t-16t gross weight, fleet average [RER] 33.69 tkm ×0.486 / ×2.06 lognormal, GSD² 2.09 -0.3 / +0.5 3.6 (Climate change-Land use and land use change)
Electricity, low voltage, at grid [JP] 0.04 kWh ×0.782 / ×1.28 lognormal, GSD² 1.28 -0.0 / +0.0 0.0 (Human toxicity, cancer_organics)

Uncertainty analysis

Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.

Comparison with other data

Source Scope Value This dataset Ratio Note
bafu 3kWp facade installation, single-Si, panel, mounted, at building [US] 2941 kg CO2 eq 2873 0.98 same dataset name, other location
bafu 3kWp facade installation, single-Si, panel, mounted, at building [CN] 2946 kg CO2 eq 2873 0.98 same dataset name, other location
bafu 3kWp facade installation, single-Si, panel, mounted, at building [CH] 2949 kg CO2 eq 2873 0.97 same dataset name, other location
bafu 3kWp facade installation, single-Si, panel, mounted, at building [RER] 2949 kg CO2 eq 2873 0.97 same dataset name, other location

Conclusions and limitations

GWP100 2873 kg CO2 eq per p (95 % interval 1865–8650). Dominant contributors: Photovoltaic panel, single-Si, at regional storage 60 %; Inverter, 2.5 kW, average, at plant 22 %; Facade construction, mounted, at building 11 %; Electric installation, photovoltaic plant, at plant 4 %; Treatment, c-Si PV module 2 %. Most sensitive: Photovoltaic panel, single-Si, at regional storage [APAC] (-15.6 / +21.1 %); Inverter, 2.5 kW, average, at plant [RER] (-4.1 / +5.1 %); Electric installation, photovoltaic plant, at plant [CH] (-2.2 / +4.6 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.

Final control

Item Status Detail
reference flow PASS production amount 1.0 p
closure: sum of direct contributions = dataset score (all 25 categories) PASS largest relative gap 2.5e-16
independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) PASS graph / published = 1; categories within ±5 %: 21/25
every technosphere input of the EcoSpold delivery is in the graph PASS all present (bafu_links_check.py)
uncertainty declared on the direct exchanges PASS 8/8 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values
Monte Carlo 95 % interval contains the deterministic score PASS 2873 in [1865, 8650]
time period declared PASS 2000-01/2000-12
geography is a known location code PASS APAC
sources cited PASS 2 reference(s), of which 1 dataset source(s); 1 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them

References

  1. Frischknecht Rolf Stolz Philippe Krebs Luana de Wild-Scholten Mariska Sinha Parikhit (2020). Task 12 PV Sustainability - Life Cycle Inventories and Life Cycle Assessments of Photovoltaic Systems. Office of Scientific and Technical Information (OSTI). https://doi.org/10.2172/2308831 — published source; matched in Crossref (author, year ±1, title overlap)
  2. Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — database; dataset citation
  3. International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva.
  4. Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. (tdc-doc method reference; title, version and year to verify against the user's copy)
  5. European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra.
  6. Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236

Annex — licence and terms of use

BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.


To suggest a correction or a dataset that does not exist yet, use Propose a dataset.

datasets/bafu/3a39e02f-f7db-4ff8-bf59-cf40f7967bc5.txt · Last modified: by 127.0.0.1

Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki