Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Railway switch [CH], per 1 my. EF v3.1 climate change 45.65 kg CO2 eq (Monte Carlo 95 % interval 39.77–59.32). Main contributors: Steel, low-alloyed, at plant 31 %; Rail, at regional storage 30 %; Concrete sleeper, at regional storage 18 %; Track bed 9 %; Cast iron, at plant 7 %; Transport, freight, lorry, 16t-32t gross weight, fleet avera… 2 %. Status: final control passed.
Item Value
Dataset name Railway switch
Dataset UUID / graph id 5205ca40-42dd-3bef-97c6-71d1544da6de / activity:railway_switch__ch
Reference product, unit Railway switch, 1 my
Location CH — Data apply to construction in Switzerland.
Time period 2011/2024
Category transport systems / train\operations\infrastructure
Source database BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1
Publisher Swiss Federal Office for the Environment (FOEN/BAFU)
Background database BAFU 2026 v1 (graph bafuquery-db)
LCIA method EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix)
Status final control passed
Documented by tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17

Introduction

This inventory was modelled according to information in Koller, (2019). The information on the materials refers to a concrete sleeper turnout with a total length of 40 m and a branch radius of 500 m. As there are significant differences in the lengths of the turnouts, this inventory was compiled per metre and can therefore be scaled to other lengths. The inventory contains the materials for the production of the entire structure of the turnouts with main track and branch track as well as track bed and sleepers. An approximation for the turnout drive has been added. Not included are cables for the control and heating of the points. The energy required for the construction work has not been taken into account, as this is largely already covered in the sub-inventories (track bed, sleepers, rails, etc.). Offcuts and rejects are not taken into account. The ecoinvent standard values were used for transport distances for material deliveries by lorry (Frischknecht et al., 2007). The service life of a switch is approx. 25 years. Maintenance work, refurbishment and dismantling are not taken into account.; UUID:5205ca40-42dd-3bef-97c6-71d1544da6de

This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.

Goal and scope

Function, functional unit and reference flow

Reference flow: 1 my of Railway switch (CH). All results are given per unit of the reference flow.

System boundary

The inventory includes all the materials, energy and transport necessary for constructing a railway switch. Excluded are maintenance and disposal

Technology

Average technology available on the market

Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).

LCIA method

EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.

Life cycle inventory

Inventory table

Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).

Exchange Type Location / compartment Amount Unit Uncertainty Pedigree GWP share (%) Notes
Steel, low-alloyed, at plant technosphere RER 6.61 kg lognormal, GSD² 1.57 — 31.0 ██████
Rail, at regional storage technosphere CH 8.2 kg lognormal, GSD² 1.31 — 29.7 ██████
Concrete sleeper, at regional storage technosphere CH 0.183 p lognormal, GSD² 1.32 — 17.7 ████
Track bed technosphere CH 10.5 m2a lognormal, GSD² 1.32 — 9.5 ██
Cast iron, at plant technosphere RER 1.81 kg lognormal, GSD² 1.57 — 7.4 █
Transport, freight, lorry, 16t-32t gross weight, fleet average technosphere RER 3.4 tkm lognormal, GSD² 2.1 — 1.6 ·
Ethylene vinyl acetate copolymer, at plant technosphere RER 0.237 kg lognormal, GSD² 1.57 — 1.3 ·
Transport, freight, rail, electricity with shunting technosphere CH 40.82 tkm lognormal, GSD² 2.1 — 1.0 ·
Electric motor, electric vehicle, at plant technosphere RER 0.125 kg lognormal, GSD² 1.6 — 0.8 ·
Adhesive for metals, at plant technosphere DE 0.00344 kg lognormal, GSD² 1.57 — 0.0 ·

Data quality

0 of 10 direct exchanges carry a declared pedigree, 10 carry a distribution.

Field As declared by the publisher
Data generator / entry / validation data generator: Gavin Roberts (CARBOTECH); data entry: Thomas Kaegi (CARBOTECH); validation (proof reading): Thomas Kaegi (CARBOTECH)
extrapolations none
sampling procedure based on literature
uncertainty adjustments none
validation details 01.10.2024
time period comment Time of publications.

Data gaps, proxies and assumptions

None recorded.

Life cycle impact assessment (EF v3.1)

Per 1 my. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.

Impact category Indicator Unit Result 2.5 % 97.5 % GSD²
Acidification Accumulated Exceedance (AE) mol H+ eq 0.1088 0.09549 0.1501 1.26
Climate change-Biogenic Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.09989 0.06399 0.2338 1.92
Climate change-Fossil Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 45.53 39.67 59.09 1.22
Climate change-Land use and land use change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.01967 0.01608 0.0313 1.42
Climate change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 45.65 39.77 59.32 1.22
EF-particulate Matter Impact on human health disease incidence 2.525e-06 2.032e-06 4.462e-06 1.5
Ecotoxicity, freshwater_inorganics Comparative Toxic Unit for ecosystems (CTUe) CTUe 91.76 83.38 183.1 1.49
Ecotoxicity, freshwater_organics Comparative Toxic Unit for ecosystems (CTUe) CTUe 5.794 4.984 12.7 1.8
Ecotoxicity, freshwater Comparative Toxic Unit for ecosystems (CTUe) CTUe 97.56 89.65 192 1.48
Eutrophication marine Fraction of nutrients reaching marine end compartment (N) kg N eq 0.03336 0.0299 0.04661 1.25
Eutrophication, freshwater Fraction of nutrients reaching freshwater end compartment (P) kg P eq 0.01523 0.01085 0.04761 2.17
Eutrophication, terrestrial Accumulated Exceedance (AE) mol N eq 0.3381 0.3036 0.4807 1.26
Human toxicity, cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 2.724e-08 2.267e-08 7.004e-08 1.75
Human toxicity, cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 1.615e-08 1.237e-08 2.778e-08 1.5
Human toxicity, cancer Comparative Toxic Unit for human (CTUh) CTUh 4.339e-08 3.819e-08 8.655e-08 1.53
Human toxicity, non-cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 1.456e-06 1.063e-06 4.462e-06 2.02
Human toxicity, non-cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 2.693e-08 2.434e-08 4.233e-08 1.33
Human toxicity, non-cancer Comparative Toxic Unit for human (CTUh) CTUh 1.483e-06 1.090e-06 4.498e-06 2
Ionising radiation, human health Human exposure efficiency relative to U235 kBq U235 eq 9.799 3.683 63.88 4.31
Land use Soil quality index pt (soil quality index) 219.9 191.7 378.7 1.42
Ozone depletion Ozone Depletion Potential (ODP) kg CFC-11 eq 5.752e-07 5.144e-07 8.882e-07 1.34
Photochemical ozone formation - human health Tropospheric ozone concentration increase kg NMVOC eq 0.1407 0.1237 0.2331 1.38
Resource use, fossils Abiotic resource depletion fossil fuels (ADP-fossil) MJ 455.5 414.5 642.1 1.25
Resource use, minerals and metals Abiotic resource depletion (ADP ultimate reserve) kg Sb eq 2.922e-04 2.411e-04 4.000e-04 1.31
Water use User deprivation potential (deprivation-weighted water consumption) m3 world eq deprived 2.121 -1.488e+04 7777 —

Climate change 45.65 kg CO2 eq per my. Main contributors: Steel, low-alloyed, at plant 31 %; Rail, at regional storage 30 %; Concrete sleeper, at regional storage 18 %; Track bed 9 %; Cast iron, at plant 7 %; Transport, freight, lorry, 16t-32t gross weight, fleet avera… 2 %.

Interpretation

Significant issues

Direct exchanges dominating climate change: Steel, low-alloyed, at plant 31 %; Rail, at regional storage 30 %; Concrete sleeper, at regional storage 18 %; Track bed 9 %; Cast iron, at plant 7 %; Transport, freight, lorry, 16t-32t gross weight, fleet avera… 2 %. Most sensitive exchanges (Section 6.3): Steel, low-alloyed, at plant [RER] (-11.1 / +17.2 %); Rail, at regional storage [CH] (-6.9 / +9.0 %); Concrete sleeper, at regional storage [CH] (-4.3 / +5.6 %).

Independent recalculation

Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per km*a, converted ×0.001 to per my:

Category Graph Published Graph / published
Acidification 0.1088 0.1296 0.840
Climate change-Biogenic 0.09989 0.09988 1.000
Climate change-Fossil 45.53 45.53 1.000
Climate change-Land use and land use change 0.01967 0.01967 1.000
Climate change 45.65 45.65 1.000
EF-particulate Matter 2.525e-06 2.525e-06 1.000
Ecotoxicity, freshwater_inorganics 91.76 97.83 0.938
Ecotoxicity, freshwater_organics 5.794 5.174 1.120
Ecotoxicity, freshwater 97.56 102.8 0.949
Eutrophication marine 0.03336 0.03336 1.000
Eutrophication, freshwater 0.01523 0.01523 1.000
Eutrophication, terrestrial 0.3381 0.3607 0.937
Human toxicity, cancer_inorganics 2.724e-08 2.711e-08 1.005
Human toxicity, cancer_organics 1.615e-08 1.615e-08 1.000
Human toxicity, cancer 4.339e-08 4.326e-08 1.003
Human toxicity, non-cancer_inorganics 1.456e-06 1.451e-06 1.003
Human toxicity, non-cancer_organics 2.693e-08 2.691e-08 1.001
Human toxicity, non-cancer 1.483e-06 1.478e-06 1.003
Ionising radiation, human health 9.799 9.799 1.000
Land use 219.9 153.4 1.434
Ozone depletion 5.752e-07 5.752e-07 1.000
Photochemical ozone formation - human health 0.1407 0.1407 1.000
Resource use, fossils 455.5 455.6 1.000
Resource use, minerals and metals 2.922e-04 2.909e-04 1.004
Water use 2.121 3.441 0.616
Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like.
Also published by BAFU for this dataset: IPCC 2021 GWP100 45.64 kg CO2 eq; Ecological Scarcity
2021 total 1.004e+05 UBP.

Sensitivity check

One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.

Exchange Base Low / high Range Δ GWP100 (%) Δ other categories (max %)
Steel, low-alloyed, at plant [RER] 6.61 kg ×0.643 / ×1.56 lognormal, GSD² 1.57 -11.1 / +17.2 23.7 (Resource use, minerals and metals)
Rail, at regional storage [CH] 8.2 kg ×0.768 / ×1.3 lognormal, GSD² 1.31 -6.9 / +9.0 11.3 (Resource use, minerals and metals)
Concrete sleeper, at regional storage [CH] 0.183 p ×0.759 / ×1.32 lognormal, GSD² 1.32 -4.3 / +5.6 5.6 (Climate change-Fossil)
Cast iron, at plant [RER] 1.81 kg ×0.643 / ×1.56 lognormal, GSD² 1.57 -2.7 / +4.1 23.0 (Human toxicity, non-cancer_inorganics)
Track bed [CH] 10.5 m2a ×0.759 / ×1.32 lognormal, GSD² 1.32 -2.3 / +3.0 11.5 (Climate change-Land use and land use change)
Transport, freight, lorry, 16t-32t gross weight, fleet average [RER] 3.4 tkm ×0.484 / ×2.06 lognormal, GSD² 2.1 -0.8 / +1.8 15.1 (Climate change-Land use and land use change)
Transport, freight, rail, electricity with shunting [CH] 40.82 tkm ×0.484 / ×2.06 lognormal, GSD² 2.1 -0.5 / +1.0 9.9 (Land use)
Ethylene vinyl acetate copolymer, at plant [RER] 0.237 kg ×0.643 / ×1.56 lognormal, GSD² 1.57 -0.5 / +0.7 7.5 (Ecotoxicity, freshwater_organics)
Electric motor, electric vehicle, at plant [RER] 0.125 kg ×0.633 / ×1.58 lognormal, GSD² 1.6 -0.3 / +0.5 4.2 (Human toxicity, non-cancer_organics)
Adhesive for metals, at plant [DE] 0.00344 kg ×0.643 / ×1.56 lognormal, GSD² 1.57 -0.0 / +0.0 0.4 (Ecotoxicity, freshwater_inorganics)

Uncertainty analysis

Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.

Comparison with other data

No other location of this dataset in the graph.

Conclusions and limitations

GWP100 45.65 kg CO2 eq per my (95 % interval 39.77–59.32). Dominant contributors: Steel, low-alloyed, at plant 31 %; Rail, at regional storage 30 %; Concrete sleeper, at regional storage 18 %; Track bed 9 %; Cast iron, at plant 7 %; Transport, freight, lorry, 16t-32t gross weight, fleet avera… 2 %. Most sensitive: Steel, low-alloyed, at plant [RER] (-11.1 / +17.2 %); Rail, at regional storage [CH] (-6.9 / +9.0 %); Concrete sleeper, at regional storage [CH] (-4.3 / +5.6 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.

Final control

Item Status Detail
reference flow PASS production amount 1.0 my
closure: sum of direct contributions = dataset score (all 25 categories) PASS largest relative gap 3.1e-16
independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per km*a, converted ×0.001 to per my (climate change) PASS graph / published = 1; categories within ±5 %: 18/25
every technosphere input of the EcoSpold delivery is in the graph PASS all present (bafu_links_check.py)
uncertainty declared on the direct exchanges PASS 10/10 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values
Monte Carlo 95 % interval contains the deterministic score PASS 45.65 in [39.77, 59.32]
time period declared PASS 2011/2024
geography is a known location code PASS CH
sources cited PASS 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them

References

  1. Report — published source; as declared by BAFU (not found in OpenAlex/Crossref)
  2. Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — database; dataset citation
  3. International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva.
  4. Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. (tdc-doc method reference; title, version and year to verify against the user's copy)
  5. European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra.
  6. Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236

Annex — licence and terms of use

BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.


To suggest a correction or a dataset that does not exist yet, use Propose a dataset.

datasets/bafu/5205ca40-42dd-3bef-97c6-71d1544da6de.txt · Last modified: by 127.0.0.1

Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki