Table of Contents
Disposal, ventilation system, Bürogebäude Verenastrasse, Baden, special comp. — CH
Dataset documentation and final control (tdc-doc, imported mode)
Open this dataset in OpenData
Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Disposal, ventilation system, Bürogebäude Verenastrasse, Baden, special comp. [CH], per 1 p. EF v3.1 climate change 7.983 kg CO2 eq (Monte Carlo 95 % interval 6.481–10.55). Main contributors: Disposal, building, bulk iron (excluding reinforcement), to … 100 %. Status: final control passed.
| Item | Value |
|---|---|
| Dataset name | Disposal, ventilation system, Bürogebäude Verenastrasse, Baden, special comp. |
| Dataset UUID / graph id | 52074243-da42-4480-8837-45545d48da53 / activity:disposal_ventilation_system_bürogebäude_verenastrasse_baden_special_comp__ch |
| Reference product, unit | Disposal, ventilation system, Bürogebäude Verenastrasse, Baden, special comp., 1 p |
| Location | CH — Specific to the technology mix encountered in sorting plants in Switzerland. |
| Time period | 2014-01/2014-12 |
| Category | waste management / building demolition |
| Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 |
| Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) |
| Background database | BAFU 2026 v1 (graph bafuquery-db) |
| LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) |
| Status | final control passed |
| Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 |
Introduction
Disposal of special components of a ventilation system for an office building with offices, kitchen, restaurant and car park. The inventory is based on a building with a total heated gross floor area of 7492 m2 and a total nominal air flow of 42500 m3/h, total weight of the components: 2379 kg/Unit, building with a specific air flow rate of 5.7 m3/h per m2 heated gross floor area. Data from call of bid including components for commercial kitchen with exhaust and supply air ceiling system mainly made of stainless steel and aluminium. Stainless steel exhaust air hood for kitchen. No ducts included.; UUID: 52074243-da42-4480-8837-45545d48da53
This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.
Goal and scope
Function, functional unit and reference flow
Reference flow: 1 p of Disposal, ventilation system, Bürogebäude Verenastrasse, Baden, special comp. (CH). All results are given per unit of the reference flow.
System boundary
Transport to dismantling facilities, machines for handling in sorting plant, electricity demand for sorting plant, final disposal of waste material. Cut-off to recycling for metals.
Technology
Disposal to a sorting plant assumed. Metal pieces, copper in cables and electronic devices are recycled, plastic parts are incinerated, inert wastes (e.g. rock wool) are landfilled.
Link to the background database
Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).
LCIA method
EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.
Life cycle inventory
Inventory table
Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).
| Exchange | Type | Location / compartment | Amount | Unit | Uncertainty | Pedigree | GWP share (%) | Notes | |
|---|---|---|---|---|---|---|---|---|---|
| Disposal, building, bulk iron (excluding reinforcement), to sorting plant | technosphere | CH | 2379 | kg | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 100.0 | ████████████████████ |
Data quality
1 of 1 direct exchanges carry a declared pedigree, 1 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 3.0 · completeness 4.0 · temporal 1.0 · geographical 1.0 · technological 1.0 · sample size 5.0.
| Field | As declared by the publisher |
|---|---|
| Data generator / entry / validation | data generator: Alex Primas (HSLU); data entry: Alex Primas (HSLU); validation (proof reading): Alex Primas (HSLU) |
| extrapolations | none |
| sampling procedure | Waste-specific calculation based on production input data |
| production volume | na |
| uncertainty adjustments | none |
| time period comment | Amount of material investigated in 2013. Disposal technology mix as used in late 1990ies |
Data gaps, proxies and assumptions
None recorded.
Life cycle impact assessment (EF v3.1)
Per 1 p. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.
| Impact category | Indicator | Unit | Result | 2.5 % | 97.5 % | GSD² |
|---|---|---|---|---|---|---|
| Acidification | Accumulated Exceedance (AE) | mol H+ eq | 0.01608 | 0.01353 | 0.02185 | 1.3 |
| Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | 0.02245 | 0.01635 | 0.03928 | 1.56 |
| Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | 7.957 | 6.461 | 10.51 | 1.28 |
| Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | 0.003251 | 0.002497 | 0.005076 | 1.45 |
| Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | 7.983 | 6.481 | 10.55 | 1.28 |
| EF-particulate Matter | Impact on human health | disease incidence | 2.487e-07 | 2.097e-07 | 3.618e-07 | 1.31 |
| Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | 18.7 | 12.42 | 46.82 | 1.95 |
| Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | 1.548 | 1.169 | 2.977 | 1.61 |
| Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | 20.25 | 13.97 | 48.28 | 1.88 |
| Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | 0.01186 | 0.009748 | 0.01525 | 1.27 |
| Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | 0.001147 | 7.209e-04 | 0.004847 | 2.59 |
| Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | 0.102 | 0.084 | 0.1317 | 1.28 |
| Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | 8.398e-10 | 8.648e-10 | 2.026e-09 | 1.56 |
| Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | 9.954e-10 | 8.043e-10 | 1.558e-09 | 1.39 |
| Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | 1.835e-09 | 1.759e-09 | 3.431e-09 | 1.4 |
| Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | 5.667e-08 | 5.531e-08 | 1.271e-07 | 1.53 |
| Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | 6.652e-09 | 5.385e-09 | 9.975e-09 | 1.37 |
| Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | 6.332e-08 | 6.146e-08 | 1.355e-07 | 1.5 |
| Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | 4.602 | 1.665 | 27.13 | 4.21 |
| Land use | Soil quality index | pt (soil quality index) | 112.4 | 79.87 | 179.7 | 1.48 |
| Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | 3.267e-07 | 2.583e-07 | 4.975e-07 | 1.4 |
| Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | 0.04747 | 0.03804 | 0.06756 | 1.33 |
| Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | 145.5 | 119.2 | 198.8 | 1.31 |
| Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | 2.221e-05 | 1.581e-05 | 4.518e-05 | 1.72 |
| Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | 0.5802 | -1700 | 857.4 | — |
Climate change 7.983 kg CO2 eq per p. Main contributors: Disposal, building, bulk iron (excluding reinforcement), to … 100 %.
Interpretation
Significant issues
Direct exchanges dominating climate change: Disposal, building, bulk iron (excluding reinforcement), to … 100 %. Most sensitive exchanges (Section 6.3): Disposal, building, bulk iron (excluding reinforcement), to sorting plant [CH] (-20.3 / +25.4 %).
Independent recalculation
The publisher publishes no LCIA result for this dataset; the closure check of Section 7 is the recalculation test.
Sensitivity check
One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.
| Exchange | Base | Low / high | Range | Δ GWP100 (%) | Δ other categories (max %) |
|---|---|---|---|---|---|
| Disposal, building, bulk iron (excluding reinforcement), to sorting plant [CH] | 2379 kg | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -20.3 / +25.4 | 25.4 (Climate change-Land use and land use change) |
Uncertainty analysis
Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.
Comparison with other data
No other location of this dataset in the graph.
Conclusions and limitations
GWP100 7.983 kg CO2 eq per p (95 % interval 6.481–10.55). Dominant contributors: Disposal, building, bulk iron (excluding reinforcement), to … 100 %. Most sensitive: Disposal, building, bulk iron (excluding reinforcement), to sorting plant [CH] (-20.3 / +25.4 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.
Final control
| Item | Status | Detail |
|---|---|---|
| reference flow | PASS | production amount 1.0 p |
| closure: sum of direct contributions = dataset score (all 25 categories) | PASS | largest relative gap 2.2e-16 |
| every technosphere input of the EcoSpold delivery is in the graph | PASS | all present (bafu_links_check.py) |
| uncertainty declared on the direct exchanges | PASS | 1/1 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values |
| Monte Carlo 95 % interval contains the deterministic score | PASS | 7.983 in [6.481, 10.55] |
| time period declared | PASS | 2014-01/2014-12 |
| geography is a known location code | PASS | CH |
| sources cited | PASS | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them |
References
- Klingler M., Kasser U., Savi D., Primas A., Stettler Y., Gujer P. (2014) Ökobilanzdaten für Lüftungs- und Wärmeanlagen. Schlussbericht, BFE. Bundesamt für Energie (BFE). Bern. Type: Separate publication Source: Report First author: Klingler M. Other authors: Kasser U., Savi D., Primas A., Stettler Y., Gujer P. Year: 2014 Title of anthology: Schlussbericht, BFE Place of publication: Bern Publisher:… — published source; as declared by BAFU (not found in OpenAlex/Crossref)
- Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — database; dataset citation
- International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva.
- Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. (tdc-doc method reference; title, version and year to verify against the user's copy)
- European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra.
- Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236
Annex — licence and terms of use
BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.
To suggest a correction or a dataset that does not exist yet, use Propose a dataset.