xxx Electricity mix, low voltage, GO cancellations — MT

Dataset documentation and final control (tdc-doc, imported mode)
Open this dataset in OpenData

Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset xxx Electricity mix, low voltage, GO cancellations [MT], per 1 kWh. EF v3.1 climate change 0.01644 kg CO2 eq (Monte Carlo 95 % interval 0.01327–0.02823). Main contributors: xxx Electricity mix, medium voltage, GO cancellations 77 %; Distribution network, electricity, low voltage 14 %; Sulfur hexafluoride 9 %. Status: final control passed.
Item Value
Dataset name xxx Electricity mix, low voltage, GO cancellations
Dataset UUID / graph id 563520b5-8849-35ec-afe4-aea56111dc20 / activity:xxx_electricity_mix_low_voltage_go_cancellations__mt
Reference product, unit xxx Electricity mix, low voltage, GO cancellations, 1 kWh
Location MT — undefined
Time period 2018-01/2018-12
Category electricity / notMaintained
Source database BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1
Publisher Swiss Federal Office for the Environment (FOEN/BAFU)
Background database BAFU 2026 v1 (graph bafuquery-db)
LCIA method EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix)
Status final control passed
Documented by tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17

Introduction

This dataset describes the transformation from medium to low voltage as well as the distribution of electricity at low voltage. Time period: Time of publications. Version: 1 Energy values: Undefined Local category: Elektrizität Local subcategory: Erzeugungsmix UVEK 2022 source file:726-Strommixe-EU_v0.8._X-GO cancellations Distribution.xml UUID: 563520b5-8849-35ec-afe4-aea56111dc20

This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.

Goal and scope

Function, functional unit and reference flow

Reference flow: 1 kWh of xxx Electricity mix, low voltage, GO cancellations (MT). All results are given per unit of the reference flow.

System boundary

Included are the electricity production in MT, the transmission network as well as direct SF6-emissions to air. Electricity losses during low-voltage transmission and transformation from medium-voltage are accounted for.

Technology

undefined

Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).

LCIA method

EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.

Life cycle inventory

Inventory table

Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).

Exchange Type Location / compartment Amount Unit Uncertainty Pedigree GWP share (%) Notes
xxx Electricity mix, medium voltage, GO cancellations technosphere MT 1.0539 kWh lognormal, GSD² 1.13 — 76.8 ███████████████
Distribution network, electricity, low voltage technosphere CH 8.7405e-08 km lognormal, GSD² 3.28 — 14.2 ███
Sulphur hexafluoride, liquid, at plant technosphere RER 5.8385e-08 kg lognormal, GSD² 1.25 — 0.0 ·
Sulfur hexafluoride elementary air/Unknown 5.8385e-08 kg lognormal, GSD² 1.58 — 8.9 ██
Waste Heat elementary soil/Unknown 0.0097106 MJ lognormal, GSD² 1.24 — 0.0 ·
Waste Heat elementary air/Unknown 0.1845 MJ lognormal, GSD² 1.24 — 0.0 ·

Data quality

0 of 6 direct exchanges carry a declared pedigree, 6 carry a distribution.

Field As declared by the publisher
Data generator / entry / validation data generator: Luana Krebs (TREEZE); data entry: Luana Krebs (TREEZE); validation (proof reading): Rolf Frischknecht (TREEZE)
extrapolations
sampling procedure
production volume na
uncertainty adjustments none
validation details Proof reading validation: 10.02.2021; Other validation: G:\Projekte laufend\726 Umweltbilanz Strommix Schweiz 2018\EcoSpold[726-Strommixe-EU_v0.8.xlsx]X-Process;
time period comment Time of publications.

Data gaps, proxies and assumptions

None recorded.

Life cycle impact assessment (EF v3.1)

Per 1 kWh. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.

Impact category Indicator Unit Result 2.5 % 97.5 % GSD²
Acidification Accumulated Exceedance (AE) mol H+ eq 9.603e-05 4.801e-05 2.906e-04 2.53
Climate change-Biogenic Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 5.692e-04 3.253e-04 0.001125 1.85
Climate change-Fossil Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.0125 0.009853 0.02337 1.54
Climate change-Land use and land use change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.003379 0.001657 0.006967 2.08
Climate change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.01644 0.01327 0.02823 1.47
EF-particulate Matter Impact on human health disease incidence 6.357e-10 4.367e-10 1.683e-09 1.99
Ecotoxicity, freshwater_inorganics Comparative Toxic Unit for ecosystems (CTUe) CTUe 0.04622 0.02738 0.1654 2.49
Ecotoxicity, freshwater_organics Comparative Toxic Unit for ecosystems (CTUe) CTUe 6.688e-04 5.166e-04 0.002144 2.12
Ecotoxicity, freshwater Comparative Toxic Unit for ecosystems (CTUe) CTUe 0.04689 0.02795 0.167 2.47
Eutrophication marine Fraction of nutrients reaching marine end compartment (N) kg N eq 1.052e-05 6.575e-06 2.897e-05 2.14
Eutrophication, freshwater Fraction of nutrients reaching freshwater end compartment (P) kg P eq 2.781e-05 1.246e-05 2.085e-04 4.53
Eutrophication, terrestrial Accumulated Exceedance (AE) mol N eq 1.117e-04 6.732e-05 2.965e-04 2.12
Human toxicity, cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 1.696e-11 1.082e-11 6.152e-11 2.46
Human toxicity, cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 2.047e-12 1.472e-12 6.914e-12 2.26
Human toxicity, cancer Comparative Toxic Unit for human (CTUh) CTUh 1.900e-11 1.271e-11 6.649e-11 2.36
Human toxicity, non-cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 1.047e-09 5.951e-10 5.088e-09 3.05
Human toxicity, non-cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 8.272e-11 3.579e-11 2.799e-10 2.89
Human toxicity, non-cancer Comparative Toxic Unit for human (CTUh) CTUh 1.129e-09 6.239e-10 5.339e-09 3
Ionising radiation, human health Human exposure efficiency relative to U235 kBq U235 eq 0.001695 6.821e-04 0.01259 4.79
Land use Soil quality index pt (soil quality index) -0.1393 -0.5016 0.04266 —
Ozone depletion Ozone Depletion Potential (ODP) kg CFC-11 eq 1.750e-10 1.004e-10 5.692e-10 2.39
Photochemical ozone formation - human health Tropospheric ozone concentration increase kg NMVOC eq 3.621e-05 2.332e-05 9.307e-05 2.01
Resource use, fossils Abiotic resource depletion fossil fuels (ADP-fossil) MJ 0.07363 0.0513 0.1802 1.86
Resource use, minerals and metals Abiotic resource depletion (ADP ultimate reserve) kg Sb eq 9.121e-07 3.497e-07 3.376e-06 3.04
Water use User deprivation potential (deprivation-weighted water consumption) m3 world eq deprived 8.729e-04 -1545 795.9 —

Climate change 0.01644 kg CO2 eq per kWh. Main contributors: xxx Electricity mix, medium voltage, GO cancellations 77 %; Distribution network, electricity, low voltage 14 %; Sulfur hexafluoride 9 %.

Interpretation

Significant issues

Direct exchanges dominating climate change: xxx Electricity mix, medium voltage, GO cancellations 77 %; Distribution network, electricity, low voltage 14 %; Sulfur hexafluoride 9 %. Most sensitive exchanges (Section 6.3): Distribution network, electricity, low voltage [CH] (-9.8 / +31.3 %); xxx Electricity mix, medium voltage, GO cancellations [MT] (-8.6 / +9.7 %); Sulfur hexafluoride [air/Unknown] (-3.2 / +5.1 %).

Independent recalculation

Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh:

Category Graph Published Graph / published
Acidification 9.603e-05 9.920e-05 0.968
Climate change-Biogenic 5.692e-04 5.692e-04 1.000
Climate change-Fossil 0.0125 0.0125 1.000
Climate change-Land use and land use change 0.003379 0.003379 1.000
Climate change 0.01644 0.01644 1.000
EF-particulate Matter 6.357e-10 6.357e-10 1.000
Ecotoxicity, freshwater_inorganics 0.04622 0.04756 0.972
Ecotoxicity, freshwater_organics 6.688e-04 6.388e-04 1.047
Ecotoxicity, freshwater 0.04689 0.04818 0.973
Eutrophication marine 1.052e-05 1.052e-05 1.000
Eutrophication, freshwater 2.781e-05 2.781e-05 1.000
Eutrophication, terrestrial 1.117e-04 1.180e-04 0.947
Human toxicity, cancer_inorganics 1.696e-11 1.692e-11 1.002
Human toxicity, cancer_organics 2.047e-12 2.046e-12 1.000
Human toxicity, cancer 1.900e-11 1.896e-11 1.002
Human toxicity, non-cancer_inorganics 1.047e-09 1.045e-09 1.002
Human toxicity, non-cancer_organics 8.272e-11 8.272e-11 1.000
Human toxicity, non-cancer 1.129e-09 1.127e-09 1.002
Ionising radiation, human health 0.001695 0.001695 1.000
Land use -0.1393 -0.1603 0.869
Ozone depletion 1.750e-10 1.750e-10 1.000
Photochemical ozone formation - human health 3.621e-05 3.621e-05 1.000
Resource use, fossils 0.07363 0.07365 1.000
Resource use, minerals and metals 9.121e-07 9.096e-07 1.003
Water use 8.729e-04 0.001057 0.826
Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like.
Also published by BAFU for this dataset: IPCC 2021 GWP100 0.01633 kg CO2 eq; Ecological Scarcity
2021 total 87.59 UBP.

Sensitivity check

One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.

Exchange Base Low / high Range Δ GWP100 (%) Δ other categories (max %)
Distribution network, electricity, low voltage [CH] 8.740e-08 km ×0.312 / ×3.21 lognormal, GSD² 3.28 -9.8 / +31.3 188.7 (Resource use, minerals and metals)
xxx Electricity mix, medium voltage, GO cancellations [MT] 1.054 kWh ×0.888 / ×1.13 lognormal, GSD² 1.13 -8.6 / +9.7 15.4 (Land use)
Sulfur hexafluoride [air/Unknown] 5.839e-08 kg ×0.637 / ×1.57 lognormal, GSD² 1.58 -3.2 / +5.1 6.7 (Climate change-Fossil)
Sulphur hexafluoride, liquid, at plant [RER] 5.839e-08 kg ×0.803 / ×1.24 lognormal, GSD² 1.25 -0.0 / +0.0 0.0 (Climate change-Fossil)

Uncertainty analysis

Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.

Comparison with other data

Source Scope Value This dataset Ratio Note
bafu xxx Electricity mix, low voltage, GO cancellations [CY] 0.01644 kg CO2 eq 0.01644 1.00 same dataset name, other location
bafu xxx Electricity mix, low voltage, GO cancellations [FR] 0.01845 kg CO2 eq 0.01644 0.89 same dataset name, other location
bafu xxx Electricity mix, low voltage, GO cancellations [PT] 0.01995 kg CO2 eq 0.01644 0.82 same dataset name, other location
bafu xxx Electricity mix, low voltage, GO cancellations [GR] 0.0216 kg CO2 eq 0.01644 0.76 same dataset name, other location
bafu xxx Electricity mix, low voltage, GO cancellations [NO] 0.02176 kg CO2 eq 0.01644 0.76 same dataset name, other location
bafu xxx Electricity mix, low voltage, GO cancellations [BE] 0.1001 kg CO2 eq 0.01644 0.16 same dataset name, other location
bafu xxx Electricity mix, low voltage, GO cancellations [ES] 0.1063 kg CO2 eq 0.01644 0.15 same dataset name, other location
bafu xxx Electricity mix, low voltage, GO cancellations [AT] 0.1584 kg CO2 eq 0.01644 0.10 same dataset name, other location
bafu xxx Electricity mix, low voltage, GO cancellations [LU] 0.1737 kg CO2 eq 0.01644 0.09 same dataset name, other location
bafu xxx Electricity mix, low voltage, GO cancellations [IE] 0.2463 kg CO2 eq 0.01644 0.07 same dataset name, other location

Conclusions and limitations

GWP100 0.01644 kg CO2 eq per kWh (95 % interval 0.01327–0.02823). Dominant contributors: xxx Electricity mix, medium voltage, GO cancellations 77 %; Distribution network, electricity, low voltage 14 %; Sulfur hexafluoride 9 %. Most sensitive: Distribution network, electricity, low voltage [CH] (-9.8 / +31.3 %); xxx Electricity mix, medium voltage, GO cancellations [MT] (-8.6 / +9.7 %); Sulfur hexafluoride [air/Unknown] (-3.2 / +5.1 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.

Final control

Item Status Detail
reference flow PASS production amount 1.0 kWh
closure: sum of direct contributions = dataset score (all 25 categories) PASS largest relative gap 2.0e-16
independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh (climate change) PASS graph / published = 1; categories within ±5 %: 22/25
every technosphere input of the EcoSpold delivery is in the graph PASS all present (bafu_links_check.py)
uncertainty declared on the direct exchanges PASS 6/6 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values
Monte Carlo 95 % interval contains the deterministic score PASS 0.01644 in [0.01327, 0.02823]
time period declared PASS 2018-01/2018-12
geography is a known location code PASS MT
sources cited PASS 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them

References

  1. Krebs L., Stolz P., Frischknecht R. (2020) Umweltbilanz Strommix Schweiz 2018. Project reports. Volume: 723. treeze Ltd.. Uster, CH. Type: Separate publication First author: Krebs L. Other authors: Stolz P., Frischknecht R. Year: 2020 Title of anthology: Project reports Place of publication: Uster, CH Publisher: treeze Ltd. Volume No: 723 — published source; as declared by BAFU (not found in OpenAlex/Crossref)
  2. Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — database; dataset citation
  3. International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva.
  4. Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. (tdc-doc method reference; title, version and year to verify against the user's copy)
  5. European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra.
  6. Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236

Annex — licence and terms of use

BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.