Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Disposal, ventilation system, Altersheim Dorflinde, various components [CH], per 1 p. EF v3.1 climate change 301.6 kg CO2 eq (Monte Carlo 95 % interval 266–356). Main contributors: Disposal, building, polyethylene/polypropylene products, to … 59 %; Disposal, rubber, unspecified, 0% water, to municipal incine… 24 %; Disposal, building, bulk iron (excluding reinforcement), to … 10 %; Disposal, building, mineral wool, to sorting plant 3 %; Disposal, building, polyvinylchloride products, to final dis… 2 %; Disposal, electronics for control units 1 %. Status: final control passed.
Item Value
Dataset name Disposal, ventilation system, Altersheim Dorflinde, various components
Dataset UUID / graph id 5bb336e1-f4a3-4371-8b86-07877070c7d6 / activity:disposal_ventilation_system_altersheim_dorflinde_various_components__ch
Reference product, unit Disposal, ventilation system, Altersheim Dorflinde, various components, 1 p
Location CH — Specific to the technology mix encountered in sorting plants in Switzerland.
Time period 2014-01/2014-12
Category waste management / building demolition
Source database BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1
Publisher Swiss Federal Office for the Environment (FOEN/BAFU)
Background database BAFU 2026 v1 (graph bafuquery-db)
LCIA method EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix)
Status final control passed
Documented by tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17

Introduction

Disposal of various components for a ventilation system for a residential care home with apartments, kitchen, cafe/restaurant, multi-purpose hall, wellness area and laundry. The inventory is based on a building with a total heated gross floor area of 34460 m2 and a total nominal air flow of m3/h, total weight of the components: 10195 kg/Unit m3/h per m2 heated gross floor area. Data from call of bid including components for air valves, air intake, roof-hoods, dampers, fire dampers, silencers and sensors.; UUID: 5bb336e1-f4a3-4371-8b86-07877070c7d6

This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.

Goal and scope

Function, functional unit and reference flow

Reference flow: 1 p of Disposal, ventilation system, Altersheim Dorflinde, various components (CH). All results are given per unit of the reference flow.

System boundary

Transport to dismantling facilities, machines for handling in sorting plant, electricity demand for sorting plant, final disposal of waste material. Cut-off to recycling for metals.

Technology

Disposal to a sorting plant assumed. Metal pieces, copper in cables and electronic devices are recycled, plastic parts are incinerated, inert wastes (e.g. rock wool) are landfilled.

Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).

LCIA method

EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.

Life cycle inventory

Inventory table

Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).

Exchange Type Location / compartment Amount Unit Uncertainty Pedigree GWP share (%) Notes
Disposal, building, polyethylene/polypropylene products, to final disposal technosphere CH 58.685 kg lognormal, GSD² 1.26 (3,4,1,1,1,5) 59.0 ████████████
Disposal, rubber, unspecified, 0% water, to municipal incineration technosphere CH 22.734 kg lognormal, GSD² 1.26 (3,4,1,1,1,5) 23.8 █████
Disposal, building, bulk iron (excluding reinforcement), to sorting plant technosphere CH 9283.5 kg lognormal, GSD² 1.26 (3,4,1,1,1,5) 10.3 ██
Disposal, building, mineral wool, to sorting plant technosphere CH 575.68 kg lognormal, GSD² 1.26 (3,4,1,1,1,5) 3.1 █
Disposal, building, polyvinylchloride products, to final disposal technosphere CH 2.442 kg lognormal, GSD² 1.26 (3,4,1,1,1,5) 1.7 ·
Disposal, electronics for control units technosphere RER 3.9309 kg lognormal, GSD² 1.34 (3,4,1,1,3,5) 1.5 ·
Disposal, building, brick, to final disposal technosphere CH 248.08 kg lognormal, GSD² 1.34 (3,4,1,1,3,5) 0.6 ·
Disposal, building, paint on metal, to sorting plant technosphere CH 0.18087 kg lognormal, GSD² 1.26 (3,4,1,1,1,5) 0.0 ·

Data quality

8 of 8 direct exchanges carry a declared pedigree, 8 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 3.0 · completeness 4.0 · temporal 1.0 · geographical 1.0 · technological 1.5 · sample size 5.0.

Field As declared by the publisher
Data generator / entry / validation data generator: Alex Primas (HSLU); data entry: Alex Primas (HSLU); validation (proof reading): Alex Primas (HSLU)
extrapolations none
sampling procedure Waste-specific calculation based on production input data
production volume na
uncertainty adjustments none
time period comment Amount of material investigated in 2013. Disposal technology mix as used in late 1990ies

Data gaps, proxies and assumptions

None recorded.

Life cycle impact assessment (EF v3.1)

Per 1 p. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.

Impact category Indicator Unit Result 2.5 % 97.5 % GSD²
Acidification Accumulated Exceedance (AE) mol H+ eq 0.1004 0.09191 0.1331 1.21
Climate change-Biogenic Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.1059 0.07955 0.1841 1.54
Climate change-Fossil Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 301.5 265.8 355.8 1.16
Climate change-Land use and land use change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.01754 0.01408 0.0255 1.36
Climate change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 301.6 266 356 1.16
EF-particulate Matter Impact on human health disease incidence 7.578e-06 5.443e-06 1.384e-05 1.59
Ecotoxicity, freshwater_inorganics Comparative Toxic Unit for ecosystems (CTUe) CTUe 573.3 493.5 918.7 1.35
Ecotoxicity, freshwater_organics Comparative Toxic Unit for ecosystems (CTUe) CTUe 7.981 6.463 15.4 1.54
Ecotoxicity, freshwater Comparative Toxic Unit for ecosystems (CTUe) CTUe 581.3 507.1 927.3 1.35
Eutrophication marine Fraction of nutrients reaching marine end compartment (N) kg N eq 0.08272 0.0722 0.108 1.23
Eutrophication, freshwater Fraction of nutrients reaching freshwater end compartment (P) kg P eq 0.04843 0.01301 1.197 11.2
Eutrophication, terrestrial Accumulated Exceedance (AE) mol N eq 0.7027 0.6162 0.9155 1.23
Human toxicity, cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 1.109e-08 1.045e-08 4.565e-08 2.16
Human toxicity, cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 7.665e-09 6.768e-09 1.121e-08 1.29
Human toxicity, cancer Comparative Toxic Unit for human (CTUh) CTUh 1.875e-08 1.876e-08 5.418e-08 1.75
Human toxicity, non-cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 6.732e-07 6.229e-07 2.713e-06 2.07
Human toxicity, non-cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 6.025e-08 4.990e-08 8.538e-08 1.32
Human toxicity, non-cancer Comparative Toxic Unit for human (CTUh) CTUh 7.334e-07 6.838e-07 2.772e-06 2
Ionising radiation, human health Human exposure efficiency relative to U235 kBq U235 eq 20.28 7.294 111.3 4.19
Land use Soil quality index pt (soil quality index) 659 345.5 1204 —
Ozone depletion Ozone Depletion Potential (ODP) kg CFC-11 eq 1.737e-06 1.444e-06 2.559e-06 1.32
Photochemical ozone formation - human health Tropospheric ozone concentration increase kg NMVOC eq 0.3052 0.2636 0.4129 1.26
Resource use, fossils Abiotic resource depletion fossil fuels (ADP-fossil) MJ 779.5 678 1024 1.23
Resource use, minerals and metals Abiotic resource depletion (ADP ultimate reserve) kg Sb eq 1.113e-04 8.542e-05 2.170e-04 1.62
Water use User deprivation potential (deprivation-weighted water consumption) m3 world eq deprived 18.6 -7836 3988 —

Climate change 301.6 kg CO2 eq per p. Main contributors: Disposal, building, polyethylene/polypropylene products, to … 59 %; Disposal, rubber, unspecified, 0% water, to municipal incine… 24 %; Disposal, building, bulk iron (excluding reinforcement), to … 10 %; Disposal, building, mineral wool, to sorting plant 3 %; Disposal, building, polyvinylchloride products, to final dis… 2 %; Disposal, electronics for control units 1 %.

Interpretation

Significant issues

Direct exchanges dominating climate change: Disposal, building, polyethylene/polypropylene products, to … 59 %; Disposal, rubber, unspecified, 0% water, to municipal incine… 24 %; Disposal, building, bulk iron (excluding reinforcement), to … 10 %; Disposal, building, mineral wool, to sorting plant 3 %; Disposal, building, polyvinylchloride products, to final dis… 2 %; Disposal, electronics for control units 1 %. Most sensitive exchanges (Section 6.3): Disposal, building, polyethylene/polypropylene products, to final disposal [CH] (-12.0 / +15.0 %); Disposal, rubber, unspecified, 0% water, to municipal incineration [CH] (-4.8 / +6.1 %); Disposal, building, bulk iron (excluding reinforcement), to sorting plant [CH] (-2.1 / +2.6 %).

Independent recalculation

Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026):

Category Graph Published Graph / published
Acidification 0.1004 0.1973 0.509
Climate change-Biogenic 0.1059 0.1059 1.000
Climate change-Fossil 301.5 301.5 1.000
Climate change-Land use and land use change 0.01754 0.01754 1.000
Climate change 301.6 301.6 1.000
EF-particulate Matter 7.578e-06 7.578e-06 1.000
Ecotoxicity, freshwater_inorganics 573.3 600.2 0.955
Ecotoxicity, freshwater_organics 7.981 7.956 1.003
Ecotoxicity, freshwater 581.3 608 0.956
Eutrophication marine 0.08272 0.08272 1.000
Eutrophication, freshwater 0.04843 0.04843 1.000
Eutrophication, terrestrial 0.7027 0.879 0.799
Human toxicity, cancer_inorganics 1.109e-08 1.102e-08 1.006
Human toxicity, cancer_organics 7.665e-09 7.665e-09 1.000
Human toxicity, cancer 1.875e-08 1.869e-08 1.004
Human toxicity, non-cancer_inorganics 6.732e-07 6.664e-07 1.010
Human toxicity, non-cancer_organics 6.025e-08 6.024e-08 1.000
Human toxicity, non-cancer 7.334e-07 7.266e-07 1.009
Ionising radiation, human health 20.28 20.28 1.000
Land use 659 398.2 1.655
Ozone depletion 1.737e-06 1.737e-06 1.000
Photochemical ozone formation - human health 0.3052 0.3052 1.000
Resource use, fossils 779.5 779.5 1.000
Resource use, minerals and metals 1.113e-04 1.040e-04 1.070
Water use 18.6 19.05 0.977
Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like.
Also published by BAFU for this dataset: IPCC 2021 GWP100 301.6 kg CO2 eq; Ecological Scarcity
2021 total 5.353e+05 UBP.

Sensitivity check

One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.

Exchange Base Low / high Range Δ GWP100 (%) Δ other categories (max %)
Disposal, building, polyethylene/polypropylene products, to final disposal [CH] 58.69 kg ×0.797 / ×1.25 lognormal, GSD² 1.26 -12.0 / +15.0 15.0 (Climate change-Fossil)
Disposal, rubber, unspecified, 0% water, to municipal incineration [CH] 22.73 kg ×0.797 / ×1.25 lognormal, GSD² 1.26 -4.8 / +6.1 6.1 (Climate change-Fossil)
Disposal, building, bulk iron (excluding reinforcement), to sorting plant [CH] 9284 kg ×0.797 / ×1.25 lognormal, GSD² 1.26 -2.1 / +2.6 22.5 (Ionising radiation, human health)
Disposal, building, mineral wool, to sorting plant [CH] 575.7 kg ×0.797 / ×1.25 lognormal, GSD² 1.26 -0.6 / +0.8 19.8 (Eutrophication, freshwater)
Disposal, electronics for control units [RER] 3.931 kg ×0.751 / ×1.33 lognormal, GSD² 1.34 -0.4 / +0.5 4.5 (Human toxicity, non-cancer_inorganics)
Disposal, building, polyvinylchloride products, to final disposal [CH] 2.442 kg ×0.797 / ×1.25 lognormal, GSD² 1.26 -0.3 / +0.4 13.3 (Water use)
Disposal, building, brick, to final disposal [CH] 248.1 kg ×0.751 / ×1.33 lognormal, GSD² 1.34 -0.2 / +0.2 8.3 (EF-particulate Matter)
Disposal, building, paint on metal, to sorting plant [CH] 0.1809 kg ×0.797 / ×1.25 lognormal, GSD² 1.26 -0.0 / +0.0 0.0 (Ionising radiation, human health)

Uncertainty analysis

Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.

Comparison with other data

No other location of this dataset in the graph.

Conclusions and limitations

GWP100 301.6 kg CO2 eq per p (95 % interval 266–356). Dominant contributors: Disposal, building, polyethylene/polypropylene products, to … 59 %; Disposal, rubber, unspecified, 0% water, to municipal incine… 24 %; Disposal, building, bulk iron (excluding reinforcement), to … 10 %; Disposal, building, mineral wool, to sorting plant 3 %; Disposal, building, polyvinylchloride products, to final dis… 2 %; Disposal, electronics for control units 1 %. Most sensitive: Disposal, building, polyethylene/polypropylene products, to final disposal [CH] (-12.0 / +15.0 %); Disposal, rubber, unspecified, 0% water, to municipal incineration [CH] (-4.8 / +6.1 %); Disposal, building, bulk iron (excluding reinforcement), to sorting plant [CH] (-2.1 / +2.6 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.

Final control

Item Status Detail
reference flow PASS production amount 1.0 p
closure: sum of direct contributions = dataset score (all 25 categories) PASS largest relative gap 3.4e-16
independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) PASS graph / published = 1; categories within ±5 %: 21/25
every technosphere input of the EcoSpold delivery is in the graph PASS all present (bafu_links_check.py)
uncertainty declared on the direct exchanges PASS 8/8 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values
Monte Carlo 95 % interval contains the deterministic score PASS 301.6 in [266, 356]
time period declared PASS 2014-01/2014-12
geography is a known location code PASS CH
sources cited PASS 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them

References

  1. Klingler M., Kasser U., Savi D., Primas A., Stettler Y., Gujer P. (2014) Ökobilanzdaten für Lüftungs- und Wärmeanlagen. Schlussbericht, BFE. Bundesamt für Energie (BFE). Bern. Type: Separate publication Source: Report First author: Klingler M. Other authors: Kasser U., Savi D., Primas A., Stettler Y., Gujer P. Year: 2014 Title of anthology: Schlussbericht, BFE Place of publication: Bern Publisher:… — published source; as declared by BAFU (not found in OpenAlex/Crossref)
  2. Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — database; dataset citation
  3. International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva.
  4. Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. (tdc-doc method reference; title, version and year to verify against the user's copy)
  5. European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra.
  6. Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236

Annex — licence and terms of use

BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.


To suggest a correction or a dataset that does not exist yet, use Propose a dataset.

datasets/bafu/5bb336e1-f4a3-4371-8b86-07877070c7d6.txt · Last modified: by 127.0.0.1

Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki