Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Cogen unit 200kWe diesel SCR, common components for heat+electricity [RER], per 1 p. EF v3.1 climate change 9.322e+04 kg CO2 eq (Monte Carlo 95 % interval 8.222e+04–1.238e+05). Main contributors: Maintenance, cogen unit 160kWe 30 %; Control cabinet cogen unit 160kWe 17 %; Gas motor 206kW 12 %; Planning, cogen unit 160kWe 8 %; Steel, converter, unalloyed, at plant 8 %; Assembly, module cogen unit 160kWe 4 %. Status: final control passed.
Item Value
Dataset name Cogen unit 200kWe diesel SCR, common components for heat+electricity
Dataset UUID / graph id 5e24cd07-20bf-31d2-b8f4-40bdf14cc4f9 / activity:cogen_unit_200kwe_diesel_scr_common_components_for_heat_plus_electricity__rer
Reference product, unit Cogen unit 200kWe diesel SCR, common components for heat+electricity, 1 p
Location RER — Extrapolated from data of a plant in Switzerland, assumed valid for Europe (RER).
Time period 1990-01/2000-12
Category heat / oil\cogeneration\power unit\infrastructure
Source database BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1
Publisher Swiss Federal Office for the Environment (FOEN/BAFU)
Background database BAFU 2026 v1 (graph bafuquery-db)
LCIA method EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix)
Status final control passed
Documented by tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17

Introduction

The module summarises infrastructure components of a cogeneration unit. ; Synonyms: Selective Catalytic Reduction, SCR; UUID: 5e24cd07-20bf-31d2-b8f4-40bdf14cc4f9

This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.

Goal and scope

Function, functional unit and reference flow

Reference flow: 1 p of Cogen unit 200kWe diesel SCR, common components for heat+electricity (RER). All results are given per unit of the reference flow.

System boundary

The module includes all shared components for heat and electricity production. Includes also SCR and oxidation catalytic converter.

Technology

Partly extrapolated from data of a 160kWe lambda=1 natural gas plant, adjusted to diesel cogen with SCR and oxidation catalytic converters.

Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).

LCIA method

EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.

Life cycle inventory

Inventory table

Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).

Exchange Type Location / compartment Amount Unit Uncertainty Pedigree GWP share (%) Notes
Maintenance, cogen unit 160kWe technosphere RER 1 p lognormal, GSD² 1.5 — 30.0 ██████
Control cabinet cogen unit 160kWe technosphere RER 1 p lognormal, GSD² 1.3 — 16.6 ███
Gas motor 206kW technosphere RER 2.5 p lognormal, GSD² 1.7 — 11.6 ██
Planning, cogen unit 160kWe technosphere RER 1 p lognormal, GSD² 1.3 — 8.4 ██
Steel, converter, unalloyed, at plant technosphere RER 3000 kg lognormal, GSD² 1.2 — 7.8 ██
Assembly, module cogen unit 160kWe technosphere RER 1 p lognormal, GSD² 1.3 — 4.3 █
Catalytic converter, SCR, 200 litre technosphere RER 2.5 p lognormal, GSD² 2.5 — 4.0 █
Supply air input/spent air output cogen unit 160kWe technosphere RER 1 p lognormal, GSD² 1.3 — 3.7 █
Catalytic converter, oxidation, 20 litre technosphere RER 5 p lognormal, GSD² 2 — 3.6 █
Sound insulation cogen unit 160kWe technosphere RER 1 p lognormal, GSD² 1.3 — 3.5 █
Construction work, cogen unit 160kWe technosphere RER 1 p lognormal, GSD² 1.3 — 2.6 █
Light fuel oil, burned in industrial furnace 1MW, non-modulating technosphere CH 16900 MJ lognormal, GSD² 1.6 (3,3,3,3,4,3) 1.7 ·
Natural gas, burned in industrial furnace 1MWth technosphere CH 16900 MJ lognormal, GSD² 1.6 (3,3,3,3,4,3) 1.4 ·
Concrete, normal, at plant technosphere CH 0.85 m3 lognormal, GSD² 1.2 — 0.2 ·
Polyethylene, HDPE, granulate, at plant technosphere RER 70 kg lognormal, GSD² 1.2 — 0.2 ·
Alkyd paint, white, 60% in H2O, at plant technosphere RER 40 kg lognormal, GSD² 1.2 — 0.1 ·
Electricity, medium voltage, production ENTSO-E, at grid technosphere ENTSO-E 344 kWh lognormal, GSD² 1.6 (3,3,3,3,4,3) 0.1 ·
Transport, freight, lorry, fleet average technosphere RER 300 tkm lognormal, GSD² 2.5 — 0.1 ·
Operation start, cogen unit 160kWe technosphere RER 1 p lognormal, GSD² 1.3 — 0.0 ·
Transport, freight, rail technosphere RER 600 tkm lognormal, GSD² 2.5 — 0.0 ·
Water elementary natural resource 4.5 m3 lognormal, GSD² 3 — 0.0 ·
Water elementary water/Unknown 4.275 m3 lognormal, GSD² 2.52 — 0.0 ·

Data quality

3 of 22 direct exchanges carry a declared pedigree, 22 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 3.0 · completeness 3.0 · temporal 3.0 · geographical 3.0 · technological 4.0 · sample size 3.0.

Field As declared by the publisher
Data generator / entry / validation data generator: Thomas Heck; data entry: Thomas Heck; validation (proof reading): Gerald Rebitzer
extrapolations see Geography/Text, see Technolgy Text
sampling procedure Operator and manufacturer information
production volume na
uncertainty adjustments none
validation details Proof reading validation: passed; Other validation: none;
time period comment undefined

Data gaps, proxies and assumptions

None recorded.

Life cycle impact assessment (EF v3.1)

Per 1 p. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.

Impact category Indicator Unit Result 2.5 % 97.5 % GSD²
Acidification Accumulated Exceedance (AE) mol H+ eq 197.3 173.8 306.4 1.34
Climate change-Biogenic Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 299.3 184.6 751.9 2.07
Climate change-Fossil Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 9.29e+04 8.194e+04 1.234e+05 1.23
Climate change-Land use and land use change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 21.31 18.97 34.33 1.36
Climate change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 9.322e+04 8.222e+04 1.238e+05 1.23
EF-particulate Matter Impact on human health disease incidence 0.003038 0.002631 0.005279 1.44
Ecotoxicity, freshwater_inorganics Comparative Toxic Unit for ecosystems (CTUe) CTUe 2.329e+05 1.980e+05 5.925e+05 1.78
Ecotoxicity, freshwater_organics Comparative Toxic Unit for ecosystems (CTUe) CTUe 7261 6489 1.696e+04 1.84
Ecotoxicity, freshwater Comparative Toxic Unit for ecosystems (CTUe) CTUe 2.402e+05 2.063e+05 6.033e+05 1.77
Eutrophication marine Fraction of nutrients reaching marine end compartment (N) kg N eq 44.94 41.81 66.3 1.26
Eutrophication, freshwater Fraction of nutrients reaching freshwater end compartment (P) kg P eq 29.16 19.65 115 2.51
Eutrophication, terrestrial Accumulated Exceedance (AE) mol N eq 415.9 385.4 612.9 1.28
Human toxicity, cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 3.240e-05 2.847e-05 1.096e-04 1.97
Human toxicity, cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 2.784e-05 2.372e-05 4.839e-05 1.44
Human toxicity, cancer Comparative Toxic Unit for human (CTUh) CTUh 6.024e-05 5.646e-05 1.461e-04 1.62
Human toxicity, non-cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 0.00186 0.001437 0.006967 2.2
Human toxicity, non-cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 1.322e-04 7.205e-05 4.079e-04 2.37
Human toxicity, non-cancer Comparative Toxic Unit for human (CTUh) CTUh 0.001992 0.001585 0.007094 2.13
Ionising radiation, human health Human exposure efficiency relative to U235 kBq U235 eq 2.356e+04 8684 1.575e+05 4.37
Land use Soil quality index pt (soil quality index) 2.848e+05 2.629e+05 5.124e+05 1.41
Ozone depletion Ozone Depletion Potential (ODP) kg CFC-11 eq 0.002205 0.001949 0.003593 1.37
Photochemical ozone formation - human health Tropospheric ozone concentration increase kg NMVOC eq 275.1 241.1 448.3 1.38
Resource use, fossils Abiotic resource depletion fossil fuels (ADP-fossil) MJ 1.258e+06 1.115e+06 1.805e+06 1.28
Resource use, minerals and metals Abiotic resource depletion (ADP ultimate reserve) kg Sb eq 0.6162 0.4504 1.177 1.67
Water use User deprivation potential (deprivation-weighted water consumption) m3 world eq deprived 5432 -2.503e+07 1.292e+07 —

Climate change 9.322e+04 kg CO2 eq per p. Main contributors: Maintenance, cogen unit 160kWe 30 %; Control cabinet cogen unit 160kWe 17 %; Gas motor 206kW 12 %; Planning, cogen unit 160kWe 8 %; Steel, converter, unalloyed, at plant 8 %; Assembly, module cogen unit 160kWe 4 %.

Interpretation

Significant issues

Direct exchanges dominating climate change: Maintenance, cogen unit 160kWe 30 %; Control cabinet cogen unit 160kWe 17 %; Gas motor 206kW 12 %; Planning, cogen unit 160kWe 8 %; Steel, converter, unalloyed, at plant 8 %; Assembly, module cogen unit 160kWe 4 %. Most sensitive exchanges (Section 6.3): Maintenance, cogen unit 160kWe [RER] (-9.8 / +14.6 %); Gas motor 206kW [RER] (-4.7 / +7.9 %); Control cabinet cogen unit 160kWe [RER] (-3.8 / +4.9 %).

Independent recalculation

Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026):

Category Graph Published Graph / published
Acidification 197.3 896.2 0.220
Climate change-Biogenic 299.3 299.3 1.000
Climate change-Fossil 9.29e+04 9.29e+04 1.000
Climate change-Land use and land use change 21.31 21.31 1.000
Climate change 9.322e+04 9.322e+04 1.000
EF-particulate Matter 0.003038 0.003038 1.000
Ecotoxicity, freshwater_inorganics 2.329e+05 2.376e+05 0.980
Ecotoxicity, freshwater_organics 7261 7222 1.005
Ecotoxicity, freshwater 2.402e+05 2.429e+05 0.989
Eutrophication marine 44.94 44.93 1.000
Eutrophication, freshwater 29.16 29.16 1.000
Eutrophication, terrestrial 415.9 449.7 0.925
Human toxicity, cancer_inorganics 3.240e-05 3.201e-05 1.012
Human toxicity, cancer_organics 2.784e-05 2.784e-05 1.000
Human toxicity, cancer 6.024e-05 5.984e-05 1.007
Human toxicity, non-cancer_inorganics 0.00186 0.001844 1.008
Human toxicity, non-cancer_organics 1.322e-04 1.322e-04 1.000
Human toxicity, non-cancer 0.001992 0.001977 1.008
Ionising radiation, human health 2.356e+04 2.356e+04 1.000
Land use 2.848e+05 2.376e+05 1.199
Ozone depletion 0.002205 0.002205 1.000
Photochemical ozone formation - human health 275.1 275.1 1.000
Resource use, fossils 1.258e+06 1.259e+06 1.000
Resource use, minerals and metals 0.6162 0.6123 1.006
Water use 5432 6108 0.889
Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like.
Also published by BAFU for this dataset: IPCC 2021 GWP100 9.321e+04 kg CO2 eq; Ecological Scarcity
2021 total 1.855e+08 UBP.

Sensitivity check

One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.

Exchange Base Low / high Range Δ GWP100 (%) Δ other categories (max %)
Maintenance, cogen unit 160kWe [RER] 1 p ×0.672 / ×1.49 lognormal, GSD² 1.5 -9.8 / +14.6 17.3 (Climate change-Land use and land use change)
Gas motor 206kW [RER] 2.5 p ×0.595 / ×1.68 lognormal, GSD² 1.7 -4.7 / +7.9 34.1 (Human toxicity, non-cancer_inorganics)
Control cabinet cogen unit 160kWe [RER] 1 p ×0.773 / ×1.29 lognormal, GSD² 1.3 -3.8 / +4.9 5.4 (Ozone depletion)
Catalytic converter, SCR, 200 litre [RER] 2.5 p ×0.407 / ×2.45 lognormal, GSD² 2.5 -2.4 / +5.8 15.0 (Resource use, minerals and metals)
Catalytic converter, oxidation, 20 litre [RER] 5 p ×0.507 / ×1.97 lognormal, GSD² 2 -1.8 / +3.5 73.0 (Human toxicity, non-cancer_organics)
Planning, cogen unit 160kWe [RER] 1 p ×0.773 / ×1.29 lognormal, GSD² 1.3 -1.9 / +2.5 3.6 (Climate change-Biogenic)
Steel, converter, unalloyed, at plant [RER] 3000 kg ×0.836 / ×1.2 lognormal, GSD² 1.2 -1.3 / +1.5 3.2 (EF-particulate Matter)
Assembly, module cogen unit 160kWe [RER] 1 p ×0.773 / ×1.29 lognormal, GSD² 1.3 -1.0 / +1.3 2.5 (Climate change-Biogenic)
Supply air input/spent air output cogen unit 160kWe [RER] 1 p ×0.773 / ×1.29 lognormal, GSD² 1.3 -0.8 / +1.1 2.6 (Climate change-Land use and land use change)
Sound insulation cogen unit 160kWe [RER] 1 p ×0.773 / ×1.29 lognormal, GSD² 1.3 -0.8 / +1.0 2.6 (Water use)
Light fuel oil, burned in industrial furnace 1MW, non-modulating [CH] 1.69e+04 MJ ×0.631 / ×1.59 lognormal, GSD² 1.6 -0.6 / +1.0 1.0 (Climate change-Fossil)
Construction work, cogen unit 160kWe [RER] 1 p ×0.773 / ×1.29 lognormal, GSD² 1.3 -0.6 / +0.8 1.7 (Climate change-Land use and land use change)
Natural gas, burned in industrial furnace 1MWth [CH] 1.69e+04 MJ ×0.631 / ×1.59 lognormal, GSD² 1.6 -0.5 / +0.8 1.0 (Ecotoxicity, freshwater_inorganics)
Transport, freight, lorry, fleet average [RER] 300 tkm ×0.407 / ×2.45 lognormal, GSD² 2.5 -0.0 / +0.1 1.5 (Climate change-Land use and land use change)
Electricity, medium voltage, production ENTSO-E, at grid [ENTSO-E] 344 kWh ×0.631 / ×1.59 lognormal, GSD² 1.6 -0.0 / +0.1 0.3 (Climate change-Biogenic)

Uncertainty analysis

Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.

Comparison with other data

No other location of this dataset in the graph.

Conclusions and limitations

GWP100 9.322e+04 kg CO2 eq per p (95 % interval 8.222e+04–1.238e+05). Dominant contributors: Maintenance, cogen unit 160kWe 30 %; Control cabinet cogen unit 160kWe 17 %; Gas motor 206kW 12 %; Planning, cogen unit 160kWe 8 %; Steel, converter, unalloyed, at plant 8 %; Assembly, module cogen unit 160kWe 4 %. Most sensitive: Maintenance, cogen unit 160kWe [RER] (-9.8 / +14.6 %); Gas motor 206kW [RER] (-4.7 / +7.9 %); Control cabinet cogen unit 160kWe [RER] (-3.8 / +4.9 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.

Final control

Item Status Detail
reference flow PASS production amount 1.0 p
closure: sum of direct contributions = dataset score (all 25 categories) PASS largest relative gap 7.2e-16
independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) PASS graph / published = 1; categories within ±5 %: 21/25
every technosphere input of the EcoSpold delivery is in the graph PASS all present (bafu_links_check.py)
uncertainty declared on the direct exchanges PASS 22/22 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values
Monte Carlo 95 % interval contains the deterministic score PASS 9.322e+04 in [8.222e+04, 1.238e+05]
time period declared PASS 1990-01/2000-12
geography is a known location code PASS RER
sources cited PASS 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them

References

  1. Heck, T. (2007) Wärme-Kraft-Kopplung. Sachbilanzen von Energiesystemen. Final report No. 6 ecoinvent data v2.0. Editors: Dones R.. Volume: 6. Swiss Centre for LCI, PSI. Dübendorf and Villigen, CH. Type: Measurement on site Source: CD-ROM First author: Heck, T. Year: 2007 Name of editors: Dones R. Title of anthology: Sachbilanzen von Energiesystemen. Final report No. 6 ecoinvent data v2.0 Place of … — published source; as declared by BAFU (not found in OpenAlex/Crossref)
  2. Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — database; dataset citation
  3. International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva.
  4. Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. (tdc-doc method reference; title, version and year to verify against the user's copy)
  5. European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra.
  6. Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236

Annex — licence and terms of use

BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.


To suggest a correction or a dataset that does not exist yet, use Propose a dataset.

datasets/bafu/5e24cd07-20bf-31d2-b8f4-40bdf14cc4f9.txt · Last modified: by 127.0.0.1

Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki