Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Disposal, ventilation system, Bürohaus Fribourg, various components [CH], per 1 p. EF v3.1 climate change 348 kg CO2 eq (Monte Carlo 95 % interval 306.6–415.1). Main contributors: Disposal, building, polyethylene/polypropylene products, to … 66 %; Disposal, rubber, unspecified, 0% water, to municipal incine… 15 %; Disposal, building, bulk iron (excluding reinforcement), to … 10 %; Disposal, building, mineral wool, to sorting plant 6 %; Disposal, electronics for control units 1 %; Disposal, building, polyvinylchloride products, to final dis… 1 %. Status: final control passed.
Item Value
Dataset name Disposal, ventilation system, Bürohaus Fribourg, various components
Dataset UUID / graph id 5f22b9a5-6d82-4f47-bab0-1125ba5f445c / activity:disposal_ventilation_system_bürohaus_fribourg_various_components__ch
Reference product, unit Disposal, ventilation system, Bürohaus Fribourg, various components, 1 p
Location CH — Specific to the technology mix encountered in sorting plants in Switzerland.
Time period 2014-01/2014-12
Category waste management / building demolition
Source database BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1
Publisher Swiss Federal Office for the Environment (FOEN/BAFU)
Background database BAFU 2026 v1 (graph bafuquery-db)
LCIA method EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix)
Status final control passed
Documented by tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17

Introduction

Disposal of various components for a ventilation system for an office building with offices, common rooms, kitchen, restaurant, auditorium and car park. The inventory is based on a building with a total heated gross floor area of 10161 m2 and a total nominal air flow of 54400 m3/h, total weight of the components: 11810 kg/Unit, building with a specific air flow rate of 5.4 m3/h per m2 heated gross floor area. Data from call of bid including components for air valves, air intake, roof-hoods, dampers, fire dampers, silencers and sensors.; UUID: 5f22b9a5-6d82-4f47-bab0-1125ba5f445c

This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.

Goal and scope

Function, functional unit and reference flow

Reference flow: 1 p of Disposal, ventilation system, Bürohaus Fribourg, various components (CH). All results are given per unit of the reference flow.

System boundary

Transport to dismantling facilities, machines for handling in sorting plant, electricity demand for sorting plant, final disposal of waste material. Cut-off to recycling for metals.

Technology

Disposal to a sorting plant assumed. Metal pieces, copper in cables and electronic devices are recycled, plastic parts are incinerated, inert wastes (e.g. rock wool) are landfilled.

Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).

LCIA method

EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.

Life cycle inventory

Inventory table

Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).

Exchange Type Location / compartment Amount Unit Uncertainty Pedigree GWP share (%) Notes
Disposal, building, polyethylene/polypropylene products, to final disposal technosphere CH 75.82 kg lognormal, GSD² 1.26 (3,4,1,1,1,5) 66.1 █████████████
Disposal, rubber, unspecified, 0% water, to municipal incineration technosphere CH 16.264 kg lognormal, GSD² 1.26 (3,4,1,1,1,5) 14.8 ███
Disposal, building, bulk iron (excluding reinforcement), to sorting plant technosphere CH 9999.1 kg lognormal, GSD² 1.26 (3,4,1,1,1,5) 9.6 ██
Disposal, building, mineral wool, to sorting plant technosphere CH 1242.7 kg lognormal, GSD² 1.26 (3,4,1,1,1,5) 5.9 █
Disposal, electronics for control units technosphere RER 4.4606 kg lognormal, GSD² 1.34 (3,4,1,1,3,5) 1.4 ·
Disposal, building, polyvinylchloride products, to final disposal technosphere CH 2.072 kg lognormal, GSD² 1.26 (3,4,1,1,1,5) 1.2 ·
Disposal, building, brick, to final disposal technosphere CH 469.89 kg lognormal, GSD² 1.34 (3,4,1,1,3,5) 1.0 ·
Disposal, building, paint on metal, to sorting plant technosphere CH 0.13416 kg lognormal, GSD² 1.26 (3,4,1,1,1,5) 0.0 ·

Data quality

8 of 8 direct exchanges carry a declared pedigree, 8 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 3.0 · completeness 4.0 · temporal 1.0 · geographical 1.0 · technological 1.5 · sample size 5.0.

Field As declared by the publisher
Data generator / entry / validation data generator: Alex Primas (HSLU); data entry: Alex Primas (HSLU); validation (proof reading): Alex Primas (HSLU)
extrapolations none
sampling procedure Waste-specific calculation based on production input data
production volume na
uncertainty adjustments none
time period comment Amount of material investigated in 2013. Disposal technology mix as used in late 1990ies

Data gaps, proxies and assumptions

None recorded.

Life cycle impact assessment (EF v3.1)

Per 1 p. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.

Impact category Indicator Unit Result 2.5 % 97.5 % GSD²
Acidification Accumulated Exceedance (AE) mol H+ eq 0.1317 0.1192 0.1749 1.2
Climate change-Biogenic Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.1265 0.09549 0.2247 1.54
Climate change-Fossil Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 347.9 306.5 414.9 1.17
Climate change-Land use and land use change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.02236 0.01874 0.03304 1.35
Climate change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 348 306.6 415.1 1.17
EF-particulate Matter Impact on human health disease incidence 1.463e-05 1.044e-05 2.721e-05 1.66
Ecotoxicity, freshwater_inorganics Comparative Toxic Unit for ecosystems (CTUe) CTUe 566.8 500.3 932.1 1.38
Ecotoxicity, freshwater_organics Comparative Toxic Unit for ecosystems (CTUe) CTUe 10.24 8.357 18.71 1.52
Ecotoxicity, freshwater Comparative Toxic Unit for ecosystems (CTUe) CTUe 577.1 512.2 946.6 1.37
Eutrophication marine Fraction of nutrients reaching marine end compartment (N) kg N eq 0.1099 0.09532 0.1423 1.22
Eutrophication, freshwater Fraction of nutrients reaching freshwater end compartment (P) kg P eq 0.09751 0.02013 2.691 12.9
Eutrophication, terrestrial Accumulated Exceedance (AE) mol N eq 0.9345 0.8131 1.215 1.22
Human toxicity, cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 1.392e-08 1.326e-08 6.047e-08 2.19
Human toxicity, cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 1.171e-08 1.006e-08 1.698e-08 1.31
Human toxicity, cancer Comparative Toxic Unit for human (CTUh) CTUh 2.563e-08 2.527e-08 7.430e-08 1.72
Human toxicity, non-cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 8.191e-07 7.464e-07 3.282e-06 2.12
Human toxicity, non-cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 9.930e-08 7.888e-08 1.478e-07 1.38
Human toxicity, non-cancer Comparative Toxic Unit for human (CTUh) CTUh 9.184e-07 8.578e-07 3.389e-06 2.02
Ionising radiation, human health Human exposure efficiency relative to U235 kBq U235 eq 23.68 8.652 138.9 4.16
Land use Soil quality index pt (soil quality index) 911.4 214.2 1913 —
Ozone depletion Ozone Depletion Potential (ODP) kg CFC-11 eq 2.199e-06 1.868e-06 3.143e-06 1.3
Photochemical ozone formation - human health Tropospheric ozone concentration increase kg NMVOC eq 0.4071 0.3535 0.5473 1.25
Resource use, fossils Abiotic resource depletion fossil fuels (ADP-fossil) MJ 1007 892.8 1312 1.21
Resource use, minerals and metals Abiotic resource depletion (ADP ultimate reserve) kg Sb eq 1.348e-04 1.069e-04 2.662e-04 1.61
Water use User deprivation potential (deprivation-weighted water consumption) m3 world eq deprived 17.04 -9566 4667 —

Climate change 348 kg CO2 eq per p. Main contributors: Disposal, building, polyethylene/polypropylene products, to … 66 %; Disposal, rubber, unspecified, 0% water, to municipal incine… 15 %; Disposal, building, bulk iron (excluding reinforcement), to … 10 %; Disposal, building, mineral wool, to sorting plant 6 %; Disposal, electronics for control units 1 %; Disposal, building, polyvinylchloride products, to final dis… 1 %.

Interpretation

Significant issues

Direct exchanges dominating climate change: Disposal, building, polyethylene/polypropylene products, to … 66 %; Disposal, rubber, unspecified, 0% water, to municipal incine… 15 %; Disposal, building, bulk iron (excluding reinforcement), to … 10 %; Disposal, building, mineral wool, to sorting plant 6 %; Disposal, electronics for control units 1 %; Disposal, building, polyvinylchloride products, to final dis… 1 %. Most sensitive exchanges (Section 6.3): Disposal, building, polyethylene/polypropylene products, to final disposal [CH] (-13.4 / +16.8 %); Disposal, rubber, unspecified, 0% water, to municipal incineration [CH] (-3.0 / +3.8 %); Disposal, building, bulk iron (excluding reinforcement), to sorting plant [CH] (-2.0 / +2.5 %).

Independent recalculation

The publisher publishes no LCIA result for this dataset; the closure check of Section 7 is the recalculation test.

Sensitivity check

One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.

Exchange Base Low / high Range Δ GWP100 (%) Δ other categories (max %)
Disposal, building, polyethylene/polypropylene products, to final disposal [CH] 75.82 kg ×0.797 / ×1.25 lognormal, GSD² 1.26 -13.4 / +16.8 16.8 (Climate change-Fossil)
Disposal, rubber, unspecified, 0% water, to municipal incineration [CH] 16.26 kg ×0.797 / ×1.25 lognormal, GSD² 1.26 -3.0 / +3.8 4.5 (Water use)
Disposal, building, bulk iron (excluding reinforcement), to sorting plant [CH] 9999 kg ×0.797 / ×1.25 lognormal, GSD² 1.26 -2.0 / +2.5 20.8 (Ionising radiation, human health)
Disposal, building, mineral wool, to sorting plant [CH] 1243 kg ×0.797 / ×1.25 lognormal, GSD² 1.26 -1.2 / +1.5 21.2 (Eutrophication, freshwater)
Disposal, electronics for control units [RER] 4.461 kg ×0.751 / ×1.33 lognormal, GSD² 1.34 -0.4 / +0.5 4.2 (Human toxicity, non-cancer_inorganics)
Disposal, building, brick, to final disposal [CH] 469.9 kg ×0.751 / ×1.33 lognormal, GSD² 1.34 -0.3 / +0.3 8.2 (EF-particulate Matter)
Disposal, building, polyvinylchloride products, to final disposal [CH] 2.072 kg ×0.797 / ×1.25 lognormal, GSD² 1.26 -0.2 / +0.3 12.3 (Water use)
Disposal, building, paint on metal, to sorting plant [CH] 0.1342 kg ×0.797 / ×1.25 lognormal, GSD² 1.26 -0.0 / +0.0 0.0 (Ionising radiation, human health)

Uncertainty analysis

Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.

Comparison with other data

No other location of this dataset in the graph.

Conclusions and limitations

GWP100 348 kg CO2 eq per p (95 % interval 306.6–415.1). Dominant contributors: Disposal, building, polyethylene/polypropylene products, to … 66 %; Disposal, rubber, unspecified, 0% water, to municipal incine… 15 %; Disposal, building, bulk iron (excluding reinforcement), to … 10 %; Disposal, building, mineral wool, to sorting plant 6 %; Disposal, electronics for control units 1 %; Disposal, building, polyvinylchloride products, to final dis… 1 %. Most sensitive: Disposal, building, polyethylene/polypropylene products, to final disposal [CH] (-13.4 / +16.8 %); Disposal, rubber, unspecified, 0% water, to municipal incineration [CH] (-3.0 / +3.8 %); Disposal, building, bulk iron (excluding reinforcement), to sorting plant [CH] (-2.0 / +2.5 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.

Final control

Item Status Detail
reference flow PASS production amount 1.0 p
closure: sum of direct contributions = dataset score (all 25 categories) PASS largest relative gap 2.0e-16
every technosphere input of the EcoSpold delivery is in the graph PASS all present (bafu_links_check.py)
uncertainty declared on the direct exchanges PASS 8/8 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values
Monte Carlo 95 % interval contains the deterministic score PASS 348 in [306.6, 415.1]
time period declared PASS 2014-01/2014-12
geography is a known location code PASS CH
sources cited PASS 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them

References

  1. Klingler M., Kasser U., Savi D., Primas A., Stettler Y., Gujer P. (2014) Ökobilanzdaten für Lüftungs- und Wärmeanlagen. Schlussbericht, BFE. Bundesamt für Energie (BFE). Bern. Type: Separate publication Source: Report First author: Klingler M. Other authors: Kasser U., Savi D., Primas A., Stettler Y., Gujer P. Year: 2014 Title of anthology: Schlussbericht, BFE Place of publication: Bern Publisher:… — published source; as declared by BAFU (not found in OpenAlex/Crossref)
  2. Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — database; dataset citation
  3. International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva.
  4. Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. (tdc-doc method reference; title, version and year to verify against the user's copy)
  5. European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra.
  6. Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236

Annex — licence and terms of use