Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Disposal, ventilation system, Bürohaus Fribourg [CH], per 1 p. EF v3.1 climate change 5811 kg CO2 eq (Monte Carlo 95 % interval 5364–6982). Main contributors: Disposal, ventilation unit 13000 m3/h, w. rotary heat exchan… 16 %; Disposal, ventilation unit 6700 m3/h, w. circuit connected h… 13 %; Disposal, ventilation unit 13000 m3/h, w. cross plate heat e… 8 %; Disposal, ventilation unit 6700 m3/h, w. cross plate heat ex… 8 %; Disposal, ventilation unit 3500 m3/h, w. cross plate heat ex… 8 %; Disposal, flexible duct, aluminum/PET, DN of 125 7 %. Status: final control passed.
Item Value
Dataset name Disposal, ventilation system, Bürohaus Fribourg
Dataset UUID / graph id 5f51097c-7943-4c6c-ac11-f169541964d9 / activity:disposal_ventilation_system_bürohaus_fribourg__ch
Reference product, unit Disposal, ventilation system, Bürohaus Fribourg, 1 p
Location CH — Specific to the technology mix encountered in sorting plants in Switzerland.
Time period 2014-01/2014-12
Category waste management / building demolition
Source database BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1
Publisher Swiss Federal Office for the Environment (FOEN/BAFU)
Background database BAFU 2026 v1 (graph bafuquery-db)
LCIA method EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix)
Status final control passed
Documented by tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17

Introduction

Disposal of a ventilation system for an office building with offices, common rooms, kitchen, restaurant, auditorium and car park. The inventory is based on a building with a total heated gross floor area of 10161 m2 and a total nominal air flow of 54400 m3/h, total weight of the components: 15755 kg/Unit, building with a specific air flow rate of 5.4 m3/h per m2 heated gross floor area. Data from call of bid including components for air handling units, ducts including insulation, air valves, roof-hoods, dampers, fire dampers, silencers. The data represent a ductwork mainly made of galvanized steel and includes air handling units mainly with heat recovery. System with central air handling units. Building without ground heat exchanger.; UUID: 5f51097c-7943-4c6c-ac11-f169541964d9

This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.

Goal and scope

Function, functional unit and reference flow

Reference flow: 1 p of Disposal, ventilation system, Bürohaus Fribourg (CH). All results are given per unit of the reference flow.

System boundary

Transport to dismantling facilities, machines for handling in sorting plant, electricity demand for sorting plant, final disposal of waste material. Cut-off to recycling for metals.

Technology

Disposal to a sorting plant assumed. Metal pieces, copper in cables and electronic devices are recycled, plastic parts are incinerated, inert wastes (e.g. rock wool) are landfilled.

Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).

LCIA method

EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.

Life cycle inventory

Inventory table

Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).

Exchange Type Location / compartment Amount Unit Uncertainty Pedigree GWP share (%) Notes
Disposal, ventilation unit 13000 m3/h, w. rotary heat exchanger technosphere CH 1.1 p lognormal, GSD² 1.26 (3,4,1,1,1,5) 15.8 ███
Disposal, ventilation unit 6700 m3/h, w. circuit connected heat exchanger technosphere CH 1.567 p lognormal, GSD² 1.26 (3,4,1,1,1,5) 13.4 ███
Disposal, ventilation unit 13000 m3/h, w. cross plate heat excanger technosphere CH 0.546 p lognormal, GSD² 1.26 (3,4,1,1,1,5) 8.3 ██
Disposal, ventilation unit 6700 m3/h, w. cross plate heat excanger technosphere CH 0.896 p lognormal, GSD² 1.26 (3,4,1,1,1,5) 8.1 ██
Disposal, ventilation unit 3500 m3/h, w. cross plate heat excanger technosphere CH 1.486 p lognormal, GSD² 1.26 (3,4,1,1,1,5) 7.6 ██
Disposal, flexible duct, aluminum/PET, DN of 125 technosphere CH 1434.4 m lognormal, GSD² 1.24 (2,4,1,1,1,5) 6.7 █
Disposal, ventilation system, Bürohaus Fribourg, various components technosphere CH 1 p lognormal, GSD² 1.24 (2,4,1,1,1,5) 6.0 █
Disposal, ventilator unit 13000 m3/h, modular, w. filter, without silencer technosphere CH 0.769 p lognormal, GSD² 1.26 (3,4,1,1,1,5) 4.8 █
Disposal, ventilation duct, steel, zinc coated, s= 0.75mm technosphere CH 1402.1 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 4.4 █
Disposal, ventilation duct, steel, zinc coated, s= 0.87mm technosphere CH 1102.6 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 3.6 █
Disposal, silencer for ventilator unit 13000 m3/h, modular technosphere CH 8.122 p lognormal, GSD² 1.26 (3,4,1,1,1,5) 3.5 █
Disposal, spiral-seam duct, steel, zinc coated, s= 0.5mm technosphere CH 563.78 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 3.2 █
Disposal, silencer for ventilator unit 6700 m3/h, modular, Device technosphere CH 9.852 p lognormal, GSD² 1.26 (3,4,1,1,1,5) 3.1 █
Disposal, ventilation duct, steel, zinc coated, s= 1.0mm technosphere CH 791.4 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 2.6 █
Disposal, EI 60 fire insulation, 70mm, 120kg/m3, reinforced alumium foil technosphere CH 364 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 1.8 ·
Disposal, ventilation duct, steel, zinc coated, s= 0.62mm technosphere CH 548.52 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 1.7 ·
Disposal, silencer for ventilator unit 3500 m3/h, modular technosphere CH 5.944 p lognormal, GSD² 1.26 (3,4,1,1,1,5) 1.3 ·
Disposal, thermal insulation, 30mm, 40kg/m3, reinforced alumium foil technosphere CH 374 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 1.0 ·
Disposal, spiral-seam duct, steel, zinc coated, s= 0.6mm technosphere CH 181.73 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 1.0 ·
Disposal, ventilation system, Bürohaus Fribourg, special components technosphere CH 1 p lognormal, GSD² 1.24 (2,4,1,1,1,5) 1.0 ·
Disposal, ventilation duct, steel, zinc coated, s= 1.25mm technosphere CH 210.68 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 0.7 ·
Disposal, spiral-seam duct, stainless steel, s= 0.8mm technosphere CH 32.044 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 0.2 ·
Disposal, spiral-seam duct, steel, zinc coated, s= 0.8mm technosphere CH 15.368 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 0.1 ·
Disposal, spiral-seam duct, stainless steel, s= 0.5mm technosphere CH 12.818 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 0.1 ·
Disposal, ventilation duct, stainless steel, s= 1.0mm technosphere CH 3.4234 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 0.0 ·
Disposal, ventilation duct, stainless steel, s= 0.87mm technosphere CH 1.68 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 0.0 ·
Disposal, ventilation duct, stainless steel, s= 0.62mm technosphere CH 0.175 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 0.0 ·

Data quality

27 of 27 direct exchanges carry a declared pedigree, 27 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 2.33 · completeness 4.0 · temporal 1.0 · geographical 1.0 · technological 1.0 · sample size 5.0.

Field As declared by the publisher
Data generator / entry / validation data generator: Alex Primas (HSLU); data entry: Alex Primas (HSLU); validation (proof reading): Alex Primas (HSLU)
extrapolations none
sampling procedure Waste-specific calculation based on production input data
production volume na
uncertainty adjustments none
time period comment Amount of material investigated in 2013. Disposal technology mix as used in late 1990ies

Data gaps, proxies and assumptions

None recorded.

Life cycle impact assessment (EF v3.1)

Per 1 p. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.

Impact category Indicator Unit Result 2.5 % 97.5 % GSD²
Acidification Accumulated Exceedance (AE) mol H+ eq 1.48 1.265 3.513 1.69
Climate change-Biogenic Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 1.018 0.8104 2.086 1.6
Climate change-Fossil Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 5810 5363 6980 1.15
Climate change-Land use and land use change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.1709 0.1483 0.2668 1.35
Climate change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 5811 5364 6982 1.15
EF-particulate Matter Impact on human health disease incidence 6.883e-05 5.119e-05 1.334e-04 1.62
Ecotoxicity, freshwater_inorganics Comparative Toxic Unit for ecosystems (CTUe) CTUe 2.43e+04 1.957e+04 3.869e+04 1.42
Ecotoxicity, freshwater_organics Comparative Toxic Unit for ecosystems (CTUe) CTUe 74.55 65.5 146.5 1.54
Ecotoxicity, freshwater Comparative Toxic Unit for ecosystems (CTUe) CTUe 2.437e+04 1.965e+04 3.877e+04 1.42
Eutrophication marine Fraction of nutrients reaching marine end compartment (N) kg N eq 1.899 1.448 5.088 1.86
Eutrophication, freshwater Fraction of nutrients reaching freshwater end compartment (P) kg P eq 0.4775 0.1284 12.69 11.2
Eutrophication, terrestrial Accumulated Exceedance (AE) mol N eq 12.63 9.12 37.43 2.07
Human toxicity, cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 2.933e-07 2.821e-07 1.263e-06 2.11
Human toxicity, cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 8.440e-08 8.021e-08 1.395e-07 1.32
Human toxicity, cancer Comparative Toxic Unit for human (CTUh) CTUh 3.777e-07 3.828e-07 1.368e-06 1.89
Human toxicity, non-cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 1.835e-05 1.794e-05 6.980e-05 2.03
Human toxicity, non-cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 5.837e-07 5.082e-07 8.841e-07 1.32
Human toxicity, non-cancer Comparative Toxic Unit for human (CTUh) CTUh 1.894e-05 1.852e-05 7.061e-05 2
Ionising radiation, human health Human exposure efficiency relative to U235 kBq U235 eq 170.2 64.95 1040 4.17
Land use Soil quality index pt (soil quality index) 5769 2525 1.093e+04 —
Ozone depletion Ozone Depletion Potential (ODP) kg CFC-11 eq 1.871e-05 1.704e-05 3.443e-05 1.42
Photochemical ozone formation - human health Tropospheric ozone concentration increase kg NMVOC eq 4.709 3.639 12.57 1.88
Resource use, fossils Abiotic resource depletion fossil fuels (ADP-fossil) MJ 8201 7502 1.596e+04 1.45
Resource use, minerals and metals Abiotic resource depletion (ADP ultimate reserve) kg Sb eq 0.001166 0.001017 0.002342 1.54
Water use User deprivation potential (deprivation-weighted water consumption) m3 world eq deprived 801.8 -7.109e+04 3.854e+04 —

Climate change 5811 kg CO2 eq per p. Main contributors: Disposal, ventilation unit 13000 m3/h, w. rotary heat exchan… 16 %; Disposal, ventilation unit 6700 m3/h, w. circuit connected h… 13 %; Disposal, ventilation unit 13000 m3/h, w. cross plate heat e… 8 %; Disposal, ventilation unit 6700 m3/h, w. cross plate heat ex… 8 %; Disposal, ventilation unit 3500 m3/h, w. cross plate heat ex… 8 %; Disposal, flexible duct, aluminum/PET, DN of 125 7 %.

Interpretation

Significant issues

Direct exchanges dominating climate change: Disposal, ventilation unit 13000 m3/h, w. rotary heat exchan… 16 %; Disposal, ventilation unit 6700 m3/h, w. circuit connected h… 13 %; Disposal, ventilation unit 13000 m3/h, w. cross plate heat e… 8 %; Disposal, ventilation unit 6700 m3/h, w. cross plate heat ex… 8 %; Disposal, ventilation unit 3500 m3/h, w. cross plate heat ex… 8 %; Disposal, flexible duct, aluminum/PET, DN of 125 7 %. Most sensitive exchanges (Section 6.3): Disposal, ventilation unit 13000 m3/h, w. rotary heat exchanger [CH] (-3.2 / +4.0 %); Disposal, ventilation unit 6700 m3/h, w. circuit connected heat exchanger [CH] (-2.7 / +3.4 %); Disposal, ventilation unit 13000 m3/h, w. cross plate heat excanger [CH] (-1.7 / +2.1 %).

Independent recalculation

The publisher publishes no LCIA result for this dataset; the closure check of Section 7 is the recalculation test.

Sensitivity check

One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.

Exchange Base Low / high Range Δ GWP100 (%) Δ other categories (max %)
Disposal, ventilation unit 13000 m3/h, w. rotary heat exchanger [CH] 1.1 p ×0.797 / ×1.25 lognormal, GSD² 1.26 -3.2 / +4.0 6.2 (Water use)
Disposal, ventilation unit 6700 m3/h, w. circuit connected heat exchanger [CH] 1.567 p ×0.797 / ×1.25 lognormal, GSD² 1.26 -2.7 / +3.4 4.7 (Water use)
Disposal, ventilation unit 13000 m3/h, w. cross plate heat excanger [CH] 0.546 p ×0.797 / ×1.25 lognormal, GSD² 1.26 -1.7 / +2.1 3.2 (Water use)
Disposal, ventilation unit 6700 m3/h, w. cross plate heat excanger [CH] 0.896 p ×0.797 / ×1.25 lognormal, GSD² 1.26 -1.6 / +2.1 2.8 (Water use)
Disposal, ventilation unit 3500 m3/h, w. cross plate heat excanger [CH] 1.486 p ×0.797 / ×1.25 lognormal, GSD² 1.26 -1.5 / +1.9 2.4 (Water use)
Disposal, flexible duct, aluminum/PET, DN of 125 [CH] 1434 m ×0.81 / ×1.23 lognormal, GSD² 1.24 -1.3 / +1.6 1.6 (Climate change-Fossil)
Disposal, ventilation system, Bürohaus Fribourg, various components [CH] 1 p ×0.81 / ×1.23 lognormal, GSD² 1.24 -1.1 / +1.4 5.0 (EF-particulate Matter)
Disposal, ventilator unit 13000 m3/h, modular, w. filter, without silencer [CH] 0.769 p ×0.797 / ×1.25 lognormal, GSD² 1.26 -1.0 / +1.2 2.1 (Water use)
Disposal, ventilation duct, steel, zinc coated, s= 0.75mm [CH] 1402 m2 ×0.81 / ×1.23 lognormal, GSD² 1.24 -0.8 / +1.0 2.9 (Ionising radiation, human health)
Disposal, silencer for ventilator unit 13000 m3/h, modular [CH] 8.122 p ×0.797 / ×1.25 lognormal, GSD² 1.26 -0.7 / +0.9 2.0 (Eutrophication marine)
Disposal, ventilation duct, steel, zinc coated, s= 0.87mm [CH] 1103 m2 ×0.81 / ×1.23 lognormal, GSD² 1.24 -0.7 / +0.8 2.6 (Ionising radiation, human health)
Disposal, silencer for ventilator unit 6700 m3/h, modular, Device [CH] 9.852 p ×0.797 / ×1.25 lognormal, GSD² 1.26 -0.6 / +0.8 1.7 (Eutrophication marine)
Disposal, spiral-seam duct, steel, zinc coated, s= 0.5mm [CH] 563.8 m2 ×0.81 / ×1.23 lognormal, GSD² 1.24 -0.6 / +0.8 0.8 (Climate change-Fossil)
Disposal, ventilation duct, steel, zinc coated, s= 1.0mm [CH] 791.4 m2 ×0.81 / ×1.23 lognormal, GSD² 1.24 -0.5 / +0.6 2.2 (Ionising radiation, human health)
Disposal, EI 60 fire insulation, 70mm, 120kg/m3, reinforced alumium foil [CH] 364 m2 ×0.81 / ×1.23 lognormal, GSD² 1.24 -0.3 / +0.4 10.8 (Eutrophication, freshwater)

Uncertainty analysis

Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.

Comparison with other data

No other location of this dataset in the graph.

Conclusions and limitations

GWP100 5811 kg CO2 eq per p (95 % interval 5364–6982). Dominant contributors: Disposal, ventilation unit 13000 m3/h, w. rotary heat exchan… 16 %; Disposal, ventilation unit 6700 m3/h, w. circuit connected h… 13 %; Disposal, ventilation unit 13000 m3/h, w. cross plate heat e… 8 %; Disposal, ventilation unit 6700 m3/h, w. cross plate heat ex… 8 %; Disposal, ventilation unit 3500 m3/h, w. cross plate heat ex… 8 %; Disposal, flexible duct, aluminum/PET, DN of 125 7 %. Most sensitive: Disposal, ventilation unit 13000 m3/h, w. rotary heat exchanger [CH] (-3.2 / +4.0 %); Disposal, ventilation unit 6700 m3/h, w. circuit connected heat exchanger [CH] (-2.7 / +3.4 %); Disposal, ventilation unit 13000 m3/h, w. cross plate heat excanger [CH] (-1.7 / +2.1 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.

Final control

Item Status Detail
reference flow PASS production amount 1.0 p
closure: sum of direct contributions = dataset score (all 25 categories) PASS largest relative gap 3.6e-16
every technosphere input of the EcoSpold delivery is in the graph PASS all present (bafu_links_check.py)
uncertainty declared on the direct exchanges PASS 27/27 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values
Monte Carlo 95 % interval contains the deterministic score PASS 5811 in [5364, 6982]
time period declared PASS 2014-01/2014-12
geography is a known location code PASS CH
sources cited PASS 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them

References

  1. Klingler M., Kasser U., Savi D., Primas A., Stettler Y., Gujer P. (2014) Ökobilanzdaten für Lüftungs- und Wärmeanlagen. Schlussbericht, BFE. Bundesamt für Energie (BFE). Bern. Type: Separate publication Source: Report First author: Klingler M. Other authors: Kasser U., Savi D., Primas A., Stettler Y., Gujer P. Year: 2014 Title of anthology: Schlussbericht, BFE Place of publication: Bern Publisher:… — published source; as declared by BAFU (not found in OpenAlex/Crossref)
  2. Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — database; dataset citation
  3. International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva.
  4. Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. (tdc-doc method reference; title, version and year to verify against the user's copy)
  5. European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra.
  6. Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236

Annex — licence and terms of use

BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.


To suggest a correction or a dataset that does not exist yet, use Propose a dataset.

datasets/bafu/5f51097c-7943-4c6c-ac11-f169541964d9.txt · Last modified: by 127.0.0.1

Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki