Table of Contents
xxx Electricity, production mix UCTE — UCTE
Dataset documentation and final control (tdc-doc, imported mode)
Open this dataset in OpenData
Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset xxx Electricity, production mix UCTE [UCTE], per 1 kWh. EF v3.1 climate change 0.4502 kg CO2 eq (Monte Carlo 95 % interval 0.4355–0.5256). Main contributors: xxx Electricity, production mix DE 29 %; xxx Electricity, production mix IT 14 %; xxx Electricity, production mix PL 12 %; xxx Electricity, production mix ES 12 %; xxx Electricity, production mix GR 5 %; xxx Electricity, production mix NL 5 %. Status: final control passed.
| Item | Value |
|---|---|
| Dataset name | xxx Electricity, production mix UCTE |
| Dataset UUID / graph id | 69d96275-7566-3a4d-a6a1-04d4faeede99 / activity:xxx_electricity_production_mix_ucte__ucte |
| Reference product, unit | xxx Electricity, production mix UCTE, 1 kWh |
| Location | UCTE |
| Time period | 9999-01/9999-12 |
| Category | energy, obsolete / electricity, obsolete\production mix, obsolete |
| Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 |
| Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) |
| Background database | BAFU 2026 v1 (graph bafuquery-db) |
| LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) |
| Status | final control passed |
| Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 |
Introduction
Electricity net production shares are based on an annual average for the year 2008 according to IEA Electricity Information.; UUID: 69d96275-7566-3a4d-a6a1-04d4faeede99
This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.
Goal and scope
Function, functional unit and reference flow
Reference flow: 1 kWh of xxx Electricity, production mix UCTE (UCTE). All results are given per unit of the reference flow.
System boundary
It includes shares of national electricity production UCTE member countries (in 2008) at the busbar. It does not include transformation, transport nor distribution losses.
Technology
No technology description is provided because the dataset just describes the power plant portfolio of the respective country using current (2004) average technology per energy carrier.
Link to the background database
Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).
LCIA method
EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.
Life cycle inventory
Inventory table
Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).
| Exchange | Type | Location / compartment | Amount | Unit | Uncertainty | Pedigree | GWP share (%) | Notes | |
|---|---|---|---|---|---|---|---|---|---|
| xxx Electricity, production mix DE | technosphere | DE | 0.22794 | kWh | lognormal, GSD² 1.05 | — | 28.5 | ██████ | |
| xxx Electricity, production mix IT | technosphere | IT | 0.11418 | kWh | lognormal, GSD² 1.05 | — | 13.7 | ███ | |
| xxx Electricity, production mix PL | technosphere | PL | 0.051314 | kWh | lognormal, GSD² 1.05 | — | 11.9 | ██ | |
| xxx Electricity, production mix ES | technosphere | ES | 0.11476 | kWh | lognormal, GSD² 1.05 | — | 11.6 | ██ | |
| xxx Electricity, production mix GR | technosphere | GR | 0.022039 | kWh | lognormal, GSD² 1.05 | — | 4.5 | █ | |
| xxx Electricity, production mix NL | technosphere | NL | 0.038199 | kWh | lognormal, GSD² 1.05 | — | 4.5 | █ | |
| xxx Electricity, production mix CZ | technosphere | CZ | 0.029412 | kWh | lognormal, GSD² 1.05 | — | 4.4 | █ | |
| xxx Electricity, production mix FR | technosphere | FR | 0.21003 | kWh | lognormal, GSD² 1.05 | — | 4.1 | █ | |
| xxx Electricity, production mix RO | technosphere | RO | 0.022484 | kWh | lognormal, GSD² 1.05 | — | 2.8 | █ | |
| xxx Electricity, production mix CS | technosphere | CS | 0.013224 | kWh | lognormal, GSD² 1.05 | — | 2.6 | █ | |
| xxx Electricity, production mix BG | technosphere | BG | 0.01568 | kWh | lognormal, GSD² 1.05 | — | 2.2 | · | |
| xxx Electricity, production mix PT | technosphere | PT | 0.01701 | kWh | lognormal, GSD² 1.05 | — | 2.0 | · | |
| xxx Electricity, production mix BE | technosphere | BE | 0.030452 | kWh | lognormal, GSD² 1.05 | — | 1.6 | · | |
| xxx Electricity, production mix HU | technosphere | HU | 0.013808 | kWh | lognormal, GSD² 1.05 | — | 1.3 | · | |
| xxx Electricity, production mix AT | technosphere | AT | 0.024611 | kWh | lognormal, GSD² 1.05 | — | 1.0 | · | |
| xxx Electricity, production mix BA | technosphere | BA | 0.0047466 | kWh | lognormal, GSD² 1.05 | — | 0.8 | · | |
| xxx Electricity, production mix SK | technosphere | SK | 0.010432 | kWh | lognormal, GSD² 1.05 | — | 0.6 | · | |
| xxx Electricity, production mix SI | technosphere | SI | 0.0060283 | kWh | lognormal, GSD² 1.05 | — | 0.5 | · | |
| xxx Electricity, production mix HR | technosphere | HR | 0.0045208 | kWh | lognormal, GSD² 1.05 | — | 0.5 | · | |
| xxx Electricity, production mix MK | technosphere | MK | 0.0022084 | kWh | lognormal, GSD² 1.05 | — | 0.5 | · | |
| Electricity, production mix CH | technosphere | CH | 0.025879 | kWh | lognormal, GSD² 1.05 | — | 0.1 | · | |
| xxx Electricity, production mix LU | technosphere | LU | 0.0010466 | kWh | lognormal, GSD² 1.05 | — | 0.1 | · |
Data quality
0 of 22 direct exchanges carry a declared pedigree, 22 carry a distribution.
| Field | As declared by the publisher |
|---|---|
| Data generator / entry / validation | data generator: René Itten (ZHAW); data entry: René Itten (ZHAW); validation (proof reading): Rolf Frischknecht (TREEZE) |
| extrapolations | none |
| sampling procedure | unknown |
| production volume | GWh |
| uncertainty adjustments | none |
| validation details | Proof reading validation: 22.06.2012; Other validation: Z:\ESU-Docs\Projekte laufend\401 Update Strommix v3.0\EcoSpold[401-electricity-mix-europe-RER-world-GLO-v1.0.xlsx]X-Process; |
| time period comment | Statistics for 2008 |
Data gaps, proxies and assumptions
None recorded.
Life cycle impact assessment (EF v3.1)
Per 1 kWh. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.
| Impact category | Indicator | Unit | Result | 2.5 % | 97.5 % | GSD² |
|---|---|---|---|---|---|---|
| Acidification | Accumulated Exceedance (AE) | mol H+ eq | 6.016e-04 | 5.918e-04 | 7.379e-04 | 1.12 |
| Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | 8.802e-04 | 7.106e-04 | 0.001393 | 1.41 |
| Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | 0.4491 | 0.4342 | 0.5243 | 1.1 |
| Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | 2.236e-04 | 1.752e-04 | 3.572e-04 | 1.44 |
| Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | 0.4502 | 0.4355 | 0.5256 | 1.1 |
| EF-particulate Matter | Impact on human health | disease incidence | 7.370e-09 | 7.044e-09 | 1.016e-08 | 1.21 |
| Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | 1.288 | 1.062 | 2.67 | 1.59 |
| Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | 0.01239 | 0.01015 | 0.03809 | 1.95 |
| Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | 1.3 | 1.08 | 2.7 | 1.59 |
| Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | 2.948e-04 | 2.848e-04 | 3.571e-04 | 1.13 |
| Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | 4.642e-04 | 1.833e-04 | 0.001608 | 2.96 |
| Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | 0.00137 | 0.001332 | 0.001932 | 1.21 |
| Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | 5.180e-11 | 5.732e-11 | 1.538e-10 | 1.64 |
| Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | 1.075e-10 | 8.666e-11 | 1.574e-10 | 1.36 |
| Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | 1.593e-10 | 1.594e-10 | 2.825e-10 | 1.33 |
| Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | 2.829e-09 | 2.936e-09 | 7.575e-09 | 1.63 |
| Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | 8.348e-11 | 7.902e-11 | 1.461e-10 | 1.36 |
| Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | 2.913e-09 | 3.030e-09 | 7.679e-09 | 1.61 |
| Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | 0.4905 | 0.1739 | 2.738 | 4.16 |
| Land use | Soil quality index | pt (soil quality index) | 1.302 | 1.013 | 2.19 | 1.49 |
| Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | 6.707e-09 | 5.699e-09 | 1.381e-08 | 1.57 |
| Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | 7.136e-04 | 6.768e-04 | 0.001131 | 1.3 |
| Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | 9.358 | 8.831 | 12.98 | 1.23 |
| Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | 8.500e-08 | 9.154e-08 | 1.875e-07 | 1.47 |
| Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | 0.07929 | -211.8 | 104.9 | — |
Climate change 0.4502 kg CO2 eq per kWh. Main contributors: xxx Electricity, production mix DE 29 %; xxx Electricity, production mix IT 14 %; xxx Electricity, production mix PL 12 %; xxx Electricity, production mix ES 12 %; xxx Electricity, production mix GR 5 %; xxx Electricity, production mix NL 5 %.
Interpretation
Significant issues
Direct exchanges dominating climate change: xxx Electricity, production mix DE 29 %; xxx Electricity, production mix IT 14 %; xxx Electricity, production mix PL 12 %; xxx Electricity, production mix ES 12 %; xxx Electricity, production mix GR 5 %; xxx Electricity, production mix NL 5 %. Most sensitive exchanges (Section 6.3): xxx Electricity, production mix DE [DE] (-1.3 / +1.4 %); xxx Electricity, production mix IT [IT] (-0.6 / +0.7 %); xxx Electricity, production mix PL [PL] (-0.6 / +0.6 %).
Independent recalculation
Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh:
| Category | Graph | Published | Graph / published |
|---|---|---|---|
| Acidification | 6.016e-04 | 0.00113 | 0.533 |
| Climate change-Biogenic | 8.802e-04 | 8.795e-04 | 1.001 |
| Climate change-Fossil | 0.4491 | 0.449 | 1.000 |
| Climate change-Land use and land use change | 2.236e-04 | 2.235e-04 | 1.000 |
| Climate change | 0.4502 | 0.4501 | 1.000 |
| EF-particulate Matter | 7.370e-09 | 7.367e-09 | 1.000 |
| Ecotoxicity, freshwater_inorganics | 1.288 | 1.336 | 0.964 |
| Ecotoxicity, freshwater_organics | 0.01239 | 0.01232 | 1.006 |
| Ecotoxicity, freshwater | 1.3 | 1.348 | 0.965 |
| Eutrophication marine | 2.948e-04 | 2.945e-04 | 1.001 |
| Eutrophication, freshwater | 4.642e-04 | 4.642e-04 | 1.000 |
| Eutrophication, terrestrial | 0.00137 | 0.002127 | 0.644 |
| Human toxicity, cancer_inorganics | 5.180e-11 | 4.040e-11 | 1.282 |
| Human toxicity, cancer_organics | 1.075e-10 | 1.075e-10 | 1.000 |
| Human toxicity, cancer | 1.593e-10 | 1.479e-10 | 1.077 |
| Human toxicity, non-cancer_inorganics | 2.829e-09 | 2.492e-09 | 1.135 |
| Human toxicity, non-cancer_organics | 8.348e-11 | 8.374e-11 | 0.997 |
| Human toxicity, non-cancer | 2.913e-09 | 2.576e-09 | 1.131 |
| Ionising radiation, human health | 0.4905 | 0.4904 | 1.000 |
| Land use | 1.302 | 1.084 | 1.201 |
| Ozone depletion | 6.707e-09 | 6.690e-09 | 1.002 |
| Photochemical ozone formation - human health | 7.136e-04 | 7.151e-04 | 0.998 |
| Resource use, fossils | 9.358 | 9.355 | 1.000 |
| Resource use, minerals and metals | 8.500e-08 | 7.621e-08 | 1.115 |
| Water use | 0.07929 | 0.09522 | 0.833 |
| Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | |||
| Also published by BAFU for this dataset: IPCC 2021 GWP100 0.4501 kg CO2 eq; Ecological Scarcity | |||
| 2021 total 789 UBP. |
Sensitivity check
One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.
| Exchange | Base | Low / high | Range | Δ GWP100 (%) | Δ other categories (max %) |
|---|---|---|---|---|---|
| xxx Electricity, production mix DE [DE] | 0.2279 kWh | ×0.953 / ×1.05 | lognormal, GSD² 1.05 | -1.3 / +1.4 | 2.5 (Climate change-Biogenic) |
| xxx Electricity, production mix IT [IT] | 0.1142 kWh | ×0.953 / ×1.05 | lognormal, GSD² 1.05 | -0.6 / +0.7 | 1.3 (Ecotoxicity, freshwater_organics) |
| xxx Electricity, production mix PL [PL] | 0.05131 kWh | ×0.953 / ×1.05 | lognormal, GSD² 1.05 | -0.6 / +0.6 | 1.4 (Human toxicity, cancer_inorganics) |
| xxx Electricity, production mix ES [ES] | 0.1148 kWh | ×0.953 / ×1.05 | lognormal, GSD² 1.05 | -0.5 / +0.6 | 1.2 (Human toxicity, cancer_organics) |
| xxx Electricity, production mix GR [GR] | 0.02204 kWh | ×0.953 / ×1.05 | lognormal, GSD² 1.05 | -0.2 / +0.2 | 0.6 (Eutrophication, freshwater) |
| xxx Electricity, production mix NL [NL] | 0.0382 kWh | ×0.953 / ×1.05 | lognormal, GSD² 1.05 | -0.2 / +0.2 | 0.4 (Land use) |
| xxx Electricity, production mix CZ [CZ] | 0.02941 kWh | ×0.953 / ×1.05 | lognormal, GSD² 1.05 | -0.2 / +0.2 | 0.4 (Acidification) |
| xxx Electricity, production mix FR [FR] | 0.21 kWh | ×0.953 / ×1.05 | lognormal, GSD² 1.05 | -0.2 / +0.2 | 2.8 (Ionising radiation, human health) |
| xxx Electricity, production mix RO [RO] | 0.02248 kWh | ×0.953 / ×1.05 | lognormal, GSD² 1.05 | -0.1 / +0.1 | 0.3 (Eutrophication, freshwater) |
| xxx Electricity, production mix CS [CS] | 0.01322 kWh | ×0.953 / ×1.05 | lognormal, GSD² 1.05 | -0.1 / +0.1 | 0.3 (Eutrophication, freshwater) |
| xxx Electricity, production mix BG [BG] | 0.01568 kWh | ×0.953 / ×1.05 | lognormal, GSD² 1.05 | -0.1 / +0.1 | 0.2 (Human toxicity, cancer_inorganics) |
| xxx Electricity, production mix PT [PT] | 0.01701 kWh | ×0.953 / ×1.05 | lognormal, GSD² 1.05 | -0.1 / +0.1 | 0.3 (Climate change-Land use and land use change) |
| xxx Electricity, production mix BE [BE] | 0.03045 kWh | ×0.953 / ×1.05 | lognormal, GSD² 1.05 | -0.1 / +0.1 | 0.3 (Ionising radiation, human health) |
| xxx Electricity, production mix HU [HU] | 0.01381 kWh | ×0.953 / ×1.05 | lognormal, GSD² 1.05 | -0.1 / +0.1 | 0.2 (Land use) |
| xxx Electricity, production mix AT [AT] | 0.02461 kWh | ×0.953 / ×1.05 | lognormal, GSD² 1.05 | -0.0 / +0.1 | 0.4 (Land use) |
Uncertainty analysis
Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.
Comparison with other data
No other location of this dataset in the graph.
Conclusions and limitations
GWP100 0.4502 kg CO2 eq per kWh (95 % interval 0.4355–0.5256). Dominant contributors: xxx Electricity, production mix DE 29 %; xxx Electricity, production mix IT 14 %; xxx Electricity, production mix PL 12 %; xxx Electricity, production mix ES 12 %; xxx Electricity, production mix GR 5 %; xxx Electricity, production mix NL 5 %. Most sensitive: xxx Electricity, production mix DE [DE] (-1.3 / +1.4 %); xxx Electricity, production mix IT [IT] (-0.6 / +0.7 %); xxx Electricity, production mix PL [PL] (-0.6 / +0.6 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.
Final control
| Item | Status | Detail |
|---|---|---|
| reference flow | PASS | production amount 1.0 kWh |
| closure: sum of direct contributions = dataset score (all 25 categories) | PASS | largest relative gap 1.8e-16 |
| independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh (climate change) | PASS | graph / published = 1; categories within ±5 %: 16/25 |
| every technosphere input of the EcoSpold delivery is in the graph | PASS | all present (bafu_links_check.py) |
| uncertainty declared on the direct exchanges | PASS | 22/22 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values |
| Monte Carlo 95 % interval contains the deterministic score | PASS | 0.4502 in [0.4355, 0.5256] |
| time period declared | PASS | 9999-01/9999-12 |
| geography is a known location code | PASS | UCTE |
| sources cited | PASS | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them |
References
- Itten, R., Frischknecht, R. (2012) Life Cycle Inventories of electricity mixes. Project reports. Volume: 401. ESU-services Ltd.. Uster, CH. Type: Separate publication First author: Itten, R. Other authors: Frischknecht, R. Year: 2012 Title of anthology: Project reports Place of publication: Uster, CH Publisher: ESU-services Ltd. Volume No: 401 — published source; as declared by BAFU (not found in OpenAlex/Crossref)
- Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — database; dataset citation
- International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva.
- Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. (tdc-doc method reference; title, version and year to verify against the user's copy)
- European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra.
- Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236
Annex — licence and terms of use
BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.
To suggest a correction or a dataset that does not exist yet, use Propose a dataset.