Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Energy-saving bulb, 11W, incl. integrated adapter, at plant [RER], per 1 p. EF v3.1 climate change 1.769 kg CO2 eq (Monte Carlo 95 % interval 1.608–2.103). Main contributors: Heat, light fuel oil, at industrial furnace 1MW 43 %; Heat, natural gas, at industrial furnace 1MW 34 %; Disposal, energy saving bulb, burnable, 0.6% water, to munic… 6 %; xx Samarium europium gadolinium concentrate, 94% rare earth … 5 %; Flat glass, uncoated, at plant 2 %; Electricity, medium voltage, production ENTSO-E, at grid 1 %. Status: final control passed.
Item Value
Dataset name Energy-saving bulb, 11W, incl. integrated adapter, at plant
Dataset UUID / graph id 76d3f641-3a58-3202-8cba-c5a8ba7e6dc9 / activity:energy_saving_bulb_11w_incl_integrated_adapter_at_plant__rer
Reference product, unit Energy-saving bulb, 11W, incl. integrated adapter, at plant, 1 p
Location RER — undefined
Time period 2000-01/2000-12
Category private consumption / lighting
Source database BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1
Publisher Swiss Federal Office for the Environment (FOEN/BAFU)
Background database BAFU 2026 v1 (graph bafuquery-db)
LCIA method EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix)
Status final control passed
Documented by tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17

Introduction

An energy saving lamp uses the same principle as a fluorescence or neon (TL) tube. Mercury gas in a partially vacuum tube emits UV light when electrical current is sent trough the tube. A convert on the inside the tube converts the light into the visible spectrum. Energy saving lamps need an adaptor containing the electric swtiches. Energy saving lamps have a much longer life time than normal light bulbs (6-8000 hrs compared to 1000 hrs). Note that when comparing light bulbs with energy saving lamps they should be compared on the basis of the amount of light produced, expressed in lumen. On average a lamp produces aroung 600 lumen. Inventory includes production, production waste, packaging, transport, and waste treatment of the full product. Technology: unknown Version: 1 Energy values: Undefined 0.0 Production volume: unknown Local category: Privater Konsum Local subcategory: Beleuchtung UVEK 2022 source file:198-Lamps-v0.2_X-Unit.xml UUID: 76d3f641-3a58-3202-8cba-c5a8ba7e6dc9

This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.

Goal and scope

Function, functional unit and reference flow

Reference flow: 1 p of Energy-saving bulb, 11W, incl. integrated adapter, at plant (RER). All results are given per unit of the reference flow.

System boundary

Light bulb SL11 (E-saving) ETH (11W energy saving lamp (8kh) with ARCO-Adapter (30kh), without energy use) ,

Technology

unknown

Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).

LCIA method

EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.

Life cycle inventory

Inventory table

Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).

Exchange Type Location / compartment Amount Unit Uncertainty Pedigree GWP share (%) Notes
Heat, light fuel oil, at industrial furnace 1MW technosphere RER 7.6 MJ lognormal, GSD² 1.05 — 43.0 █████████
Heat, natural gas, at industrial furnace 1MW technosphere CH 7.6 MJ lognormal, GSD² 1.05 — 34.5 ███████
Disposal, energy saving bulb, burnable, 0.6% water, to municipal incineration technosphere CH 0.056 kg lognormal, GSD² 1.05 — 6.5 █
xx Samarium europium gadolinium concentrate, 94% rare earth oxide, at plant technosphere CN 0.0017613 kg lognormal, GSD² 1.05 — 5.5 █
Flat glass, uncoated, at plant technosphere RER 0.039 kg lognormal, GSD² 1.05 — 2.2 ·
Electricity, medium voltage, production ENTSO-E, at grid technosphere ENTSO-E 0.088889 kWh lognormal, GSD² 1.05 — 1.4 ·
Aluminium, primary, at plant technosphere RER 0.002 kg lognormal, GSD² 1.05 — 1.0 ·
Transport, freight, lorry, fleet average technosphere RER 0.0704 tkm lognormal, GSD² 2 — 0.8 ·
Corrugated board, mixed fibre, single wall, at plant technosphere RER 0.013 kg lognormal, GSD² 1.05 — 0.7 ·
Polycarbonate, at plant technosphere RER 0.00141 kg lognormal, GSD² 1.05 — 0.6 ·
Steel, low-alloyed, at plant technosphere RER 0.0045 kg lognormal, GSD² 1.05 — 0.5 ·
Polyurethane, flexible foam, at plant technosphere RER 0.0018 kg lognormal, GSD² 1.05 — 0.5 ·
Copper, at regional storage technosphere RER 0.0046 kg lognormal, GSD² 1.05 — 0.4 ·
Oxygen, liquid, at plant technosphere RER 0.0325 kg lognormal, GSD² 1.05 — 0.4 ·
Epoxy resin, liquid, at plant technosphere RER 8.6370e-04 kg lognormal, GSD² 1.05 — 0.3 ·
Polyester resin, unsaturated, at plant technosphere RER 8.6370e-04 kg lognormal, GSD² 1.05 — 0.3 ·
Ferrite, at plant technosphere GLO 0.003887 kg lognormal, GSD² 1.05 — 0.3 ·
Nitrogen, liquid, at plant technosphere RER 0.0187 kg lognormal, GSD² 1.05 — 0.2 ·
Tin, at regional storage technosphere RER 2.8800e-04 kg lognormal, GSD² 1.05 — 0.2 ·
Polyvinylchloride, at regional storage technosphere RER 9.1200e-04 kg lognormal, GSD² 1.05 — 0.1 ·
Chromium, at regional storage technosphere RER 1.0000e-04 kg lognormal, GSD² 1.05 — 0.1 ·
Disposal, plastics, mixture, 15.3% water, to municipal incineration technosphere CH 7.9200e-04 kg lognormal, GSD² 1.05 — 0.1 ·
Zinc, primary, at regional storage technosphere RER 4.0000e-04 kg lognormal, GSD² 1.05 — 0.1 ·
Alkyd paint, white, 60% in H2O, at plant technosphere RER 2.4000e-04 kg lognormal, GSD² 1.05 — 0.0 ·
Cerium concentrate, 60% cerium oxide, at plant technosphere CN 6.8560e-05 kg lognormal, GSD² 1.05 — 0.0 ·
MG-silicon, at plant technosphere NO 1.0000e-04 kg lognormal, GSD² 1.05 — 0.0 ·
Disposal, energy saving bulb, inert, 0% water, to municipal incineration technosphere CH 0.0187 kg lognormal, GSD² 1.05 — 0.0 ·
Disposal, packaging cardboard, 19.6% water, to municipal incineration technosphere CH 0.013 kg lognormal, GSD² 1.05 — 0.0 ·
Paper, woodfree, coated, at regional storage technosphere RER 3.0000e-04 kg lognormal, GSD² 1.05 — 0.0 ·
Antimony, at refinery technosphere CN 3.5740e-05 kg lognormal, GSD² 1.05 — 0.0 ·
Transport, freight, rail technosphere RER 0.0186 tkm lognormal, GSD² 2 — 0.0 ·
Nickel, 99.5%, at plant technosphere GLO 3.0000e-05 kg lognormal, GSD² 1.05 — 0.0 ·
Lead, at regional storage technosphere RER 1.4400e-04 kg lognormal, GSD² 1.05 — 0.0 ·
Mercury, liquid, at plant technosphere GLO 9.5970e-06 kg lognormal, GSD² 1.05 — 0.0 ·
Ceramic tiles, at regional storage technosphere CH 1.0000e-04 kg lognormal, GSD² 1.05 — 0.0 ·
Water, decarbonised, at plant technosphere RER 6.7 kg lognormal, GSD² 1.05 — 0.0 ·
Disposal, glass, 0% water, to construction waste landfill technosphere CH 0.00161 kg lognormal, GSD² 1.05 — 0.0 ·
Hydrochloric acid, 30% in H2O, at plant technosphere RER 1.0000e-06 kg lognormal, GSD² 1.05 — 0.0 ·
Barite, at plant technosphere RER 2.0000e-06 kg lognormal, GSD² 1.05 — 0.0 ·
Argon, liquid, at plant technosphere RER 2.1900e-07 kg lognormal, GSD² 1.05 — 0.0 ·
Waste Heat elementary air/Unknown 0.32 MJ lognormal, GSD² 1.05 — 0.0 ·
Mercury elementary air/Unknown 2.0200e-07 kg lognormal, GSD² 5 — 0.0 ·
Non-methane Volatile Organic Compounds elementary air/Unknown 4.8000e-04 kg lognormal, GSD² 1.5 — 0.0 ·
Sulfur Dioxide elementary air/Unknown 2.0900e-05 kg lognormal, GSD² 1.05 — 0.0 ·

Data quality

0 of 44 direct exchanges carry a declared pedigree, 44 carry a distribution.

Field As declared by the publisher
Data generator / entry / validation data generator: Matthias Stucki (ZHAW); data entry: Matthias Stucki (ZHAW); validation (proof reading): Rolf Frischknecht (TREEZE)
extrapolations none
sampling procedure unknown
production volume na
uncertainty adjustments none
validation details Proof reading validation: 23.08.2010; Other validation: C:\Dokumente und Einstellungen\Matthias S\Eigene Dateien\1_Projekte\198 Vorträge\Pusch[198-Lamps-v0.2.xls]X-Process;
time period comment undefined

Data gaps, proxies and assumptions

None recorded.

Life cycle impact assessment (EF v3.1)

Per 1 p. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.

Impact category Indicator Unit Result 2.5 % 97.5 % GSD²
Acidification Accumulated Exceedance (AE) mol H+ eq 0.003173 0.003004 0.003981 1.16
Climate change-Biogenic Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.001778 0.001123 0.004623 2.05
Climate change-Fossil Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 1.767 1.605 2.099 1.15
Climate change-Land use and land use change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 2.799e-04 2.402e-04 4.255e-04 1.33
Climate change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 1.769 1.608 2.103 1.15
EF-particulate Matter Impact on human health disease incidence 2.290e-08 2.201e-08 9.953e-08 2.17
Ecotoxicity, freshwater_inorganics Comparative Toxic Unit for ecosystems (CTUe) CTUe 7.895 6.264 15.06 1.57
Ecotoxicity, freshwater_organics Comparative Toxic Unit for ecosystems (CTUe) CTUe 0.1835 0.1556 0.3124 1.43
Ecotoxicity, freshwater Comparative Toxic Unit for ecosystems (CTUe) CTUe 8.078 6.453 15.29 1.56
Eutrophication marine Fraction of nutrients reaching marine end compartment (N) kg N eq 6.960e-04 6.452e-04 9.644e-04 1.23
Eutrophication, freshwater Fraction of nutrients reaching freshwater end compartment (P) kg P eq 3.713e-04 2.584e-04 0.001957 2.84
Eutrophication, terrestrial Accumulated Exceedance (AE) mol N eq 0.00665 0.006097 0.009029 1.23
Human toxicity, cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 2.039e-09 7.881e-10 9.152e-09 3.49
Human toxicity, cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 1.366e-10 1.284e-10 2.171e-10 1.32
Human toxicity, cancer Comparative Toxic Unit for human (CTUh) CTUh 2.175e-09 9.531e-10 9.333e-09 3.2
Human toxicity, non-cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 2.334e-07 8.043e-08 1.066e-06 3.7
Human toxicity, non-cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 1.315e-09 1.041e-09 2.100e-09 1.43
Human toxicity, non-cancer Comparative Toxic Unit for human (CTUh) CTUh 2.348e-07 8.148e-08 1.068e-06 3.67
Ionising radiation, human health Human exposure efficiency relative to U235 kBq U235 eq 0.1274 0.0476 0.8272 4.41
Land use Soil quality index pt (soil quality index) 3.129 2.992 4.895 1.29
Ozone depletion Ozone Depletion Potential (ODP) kg CFC-11 eq 4.688e-08 3.835e-08 7.173e-08 1.38
Photochemical ozone formation - human health Tropospheric ozone concentration increase kg NMVOC eq 0.004311 0.0036 0.006423 1.35
Resource use, fossils Abiotic resource depletion fossil fuels (ADP-fossil) MJ 24.18 19.77 35.38 1.34
Resource use, minerals and metals Abiotic resource depletion (ADP ultimate reserve) kg Sb eq 4.598e-05 3.778e-05 5.754e-05 1.24
Water use User deprivation potential (deprivation-weighted water consumption) m3 world eq deprived 0.3373 -110.9 58.15 —

Climate change 1.769 kg CO2 eq per p. Main contributors: Heat, light fuel oil, at industrial furnace 1MW 43 %; Heat, natural gas, at industrial furnace 1MW 34 %; Disposal, energy saving bulb, burnable, 0.6% water, to munic… 6 %; xx Samarium europium gadolinium concentrate, 94% rare earth … 5 %; Flat glass, uncoated, at plant 2 %; Electricity, medium voltage, production ENTSO-E, at grid 1 %.

Interpretation

Significant issues

Direct exchanges dominating climate change: Heat, light fuel oil, at industrial furnace 1MW 43 %; Heat, natural gas, at industrial furnace 1MW 34 %; Disposal, energy saving bulb, burnable, 0.6% water, to munic… 6 %; xx Samarium europium gadolinium concentrate, 94% rare earth … 5 %; Flat glass, uncoated, at plant 2 %; Electricity, medium voltage, production ENTSO-E, at grid 1 %. Most sensitive exchanges (Section 6.3): Heat, light fuel oil, at industrial furnace 1MW [RER] (-2.0 / +2.1 %); Heat, natural gas, at industrial furnace 1MW [CH] (-1.6 / +1.7 %); Transport, freight, lorry, fleet average [RER] (-0.4 / +0.7 %).

Independent recalculation

Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026):

Category Graph Published Graph / published
Acidification 0.003173 0.003408 0.931
Climate change-Biogenic 0.001778 0.001778 1.000
Climate change-Fossil 1.767 1.767 1.000
Climate change-Land use and land use change 2.799e-04 2.799e-04 1.000
Climate change 1.769 1.769 1.000
EF-particulate Matter 2.290e-08 2.290e-08 1.000
Ecotoxicity, freshwater_inorganics 7.895 7.949 0.993
Ecotoxicity, freshwater_organics 0.1835 0.177 1.036
Ecotoxicity, freshwater 8.078 8.124 0.994
Eutrophication marine 6.960e-04 6.959e-04 1.000
Eutrophication, freshwater 3.713e-04 3.713e-04 1.000
Eutrophication, terrestrial 0.00665 0.007122 0.934
Human toxicity, cancer_inorganics 2.039e-09 2.037e-09 1.001
Human toxicity, cancer_organics 1.366e-10 1.366e-10 1.000
Human toxicity, cancer 2.175e-09 2.173e-09 1.001
Human toxicity, non-cancer_inorganics 2.334e-07 2.334e-07 1.000
Human toxicity, non-cancer_organics 1.315e-09 1.314e-09 1.000
Human toxicity, non-cancer 2.348e-07 2.347e-07 1.000
Ionising radiation, human health 0.1274 0.1274 1.000
Land use 3.129 2.934 1.066
Ozone depletion 4.688e-08 4.688e-08 1.000
Photochemical ozone formation - human health 0.004311 0.004311 1.000
Resource use, fossils 24.18 24.18 1.000
Resource use, minerals and metals 4.598e-05 1.238e-05 3.716
Water use 0.3373 0.3396 0.993
Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like.
Also published by BAFU for this dataset: IPCC 2021 GWP100 1.769 kg CO2 eq; Ecological Scarcity
2021 total 3689 UBP.

Sensitivity check

One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.

Exchange Base Low / high Range Δ GWP100 (%) Δ other categories (max %)
Heat, light fuel oil, at industrial furnace 1MW [RER] 7.6 MJ ×0.953 / ×1.05 lognormal, GSD² 1.05 -2.0 / +2.1 2.1 (Climate change-Fossil)
Heat, natural gas, at industrial furnace 1MW [CH] 7.6 MJ ×0.953 / ×1.05 lognormal, GSD² 1.05 -1.6 / +1.7 2.0 (Resource use, fossils)
Transport, freight, lorry, fleet average [RER] 0.0704 tkm ×0.507 / ×1.97 lognormal, GSD² 2 -0.4 / +0.7 17.8 (Climate change-Land use and land use change)
Disposal, energy saving bulb, burnable, 0.6% water, to municipal incineration [CH] 0.056 kg ×0.953 / ×1.05 lognormal, GSD² 1.05 -0.3 / +0.3 1.2 (Ecotoxicity, freshwater_inorganics)
xx Samarium europium gadolinium concentrate, 94% rare earth oxide, at plant [CN] 0.001761 kg ×0.953 / ×1.05 lognormal, GSD² 1.05 -0.3 / +0.3 0.9 (Climate change-Land use and land use change)
Flat glass, uncoated, at plant [RER] 0.039 kg ×0.953 / ×1.05 lognormal, GSD² 1.05 -0.1 / +0.1 0.8 (EF-particulate Matter)
Electricity, medium voltage, production ENTSO-E, at grid [ENTSO-E] 0.08889 kWh ×0.953 / ×1.05 lognormal, GSD² 1.05 -0.1 / +0.1 1.2 (Ionising radiation, human health)
Aluminium, primary, at plant [RER] 0.002 kg ×0.953 / ×1.05 lognormal, GSD² 1.05 -0.0 / +0.0 0.4 (Climate change-Land use and land use change)
Corrugated board, mixed fibre, single wall, at plant [RER] 0.013 kg ×0.953 / ×1.05 lognormal, GSD² 1.05 -0.0 / +0.0 1.0 (Land use)
Polycarbonate, at plant [RER] 0.00141 kg ×0.953 / ×1.05 lognormal, GSD² 1.05 -0.0 / +0.0 0.2 (EF-particulate Matter)
Steel, low-alloyed, at plant [RER] 0.0045 kg ×0.953 / ×1.05 lognormal, GSD² 1.05 -0.0 / +0.0 0.1 (Human toxicity, cancer_organics)
Polyurethane, flexible foam, at plant [RER] 0.0018 kg ×0.953 / ×1.05 lognormal, GSD² 1.05 -0.0 / +0.0 0.3 (Ecotoxicity, freshwater_inorganics)
Copper, at regional storage [RER] 0.0046 kg ×0.953 / ×1.05 lognormal, GSD² 1.05 -0.0 / +0.0 3.2 (Eutrophication, freshwater)
Oxygen, liquid, at plant [RER] 0.0325 kg ×0.953 / ×1.05 lognormal, GSD² 1.05 -0.0 / +0.0 0.3 (Ionising radiation, human health)
Epoxy resin, liquid, at plant [RER] 8.637e-04 kg ×0.953 / ×1.05 lognormal, GSD² 1.05 -0.0 / +0.0 0.3 (EF-particulate Matter)

Uncertainty analysis

Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.

Comparison with other data

No other location of this dataset in the graph.

Conclusions and limitations

GWP100 1.769 kg CO2 eq per p (95 % interval 1.608–2.103). Dominant contributors: Heat, light fuel oil, at industrial furnace 1MW 43 %; Heat, natural gas, at industrial furnace 1MW 34 %; Disposal, energy saving bulb, burnable, 0.6% water, to munic… 6 %; xx Samarium europium gadolinium concentrate, 94% rare earth … 5 %; Flat glass, uncoated, at plant 2 %; Electricity, medium voltage, production ENTSO-E, at grid 1 %. Most sensitive: Heat, light fuel oil, at industrial furnace 1MW [RER] (-2.0 / +2.1 %); Heat, natural gas, at industrial furnace 1MW [CH] (-1.6 / +1.7 %); Transport, freight, lorry, fleet average [RER] (-0.4 / +0.7 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.

Final control

Item Status Detail
reference flow PASS production amount 1.0 p
closure: sum of direct contributions = dataset score (all 25 categories) PASS largest relative gap 5.9e-16
independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) PASS graph / published = 1; categories within ±5 %: 21/25
every technosphere input of the EcoSpold delivery is in the graph PASS all present (bafu_links_check.py)
uncertainty declared on the direct exchanges PASS 44/44 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values
Monte Carlo 95 % interval contains the deterministic score PASS 1.769 in [1.608, 2.103]
time period declared PASS 2000-01/2000-12
geography is a known location code PASS RER
sources cited PASS 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them

References

  1. Ch. Bauer, Frischknecht (2012) Umweltauswirkungen Strom. Volume: 407. PSI. Uster und Villigen, CH. Type: Separate publication Source: CD-ROM First author: Ch. Bauer Other authors: Frischknecht Year: 2012 Place of publication: Uster und Villigen, CH Publisher: PSI Volume No: 407 — published source; as declared by BAFU (not found in OpenAlex/Crossref)
  2. Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — database; dataset citation
  3. International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva.
  4. Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. (tdc-doc method reference; title, version and year to verify against the user's copy)
  5. European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra.
  6. Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236

Annex — licence and terms of use

BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.


To suggest a correction or a dataset that does not exist yet, use Propose a dataset.

datasets/bafu/76d3f641-3a58-3202-8cba-c5a8ba7e6dc9.txt · Last modified: by 127.0.0.1

Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki