Table of Contents
Heat pump Limmatschulhaus — CH
Dataset documentation and final control (tdc-doc, imported mode)
Open this dataset in OpenData
Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Heat pump Limmatschulhaus [CH], per 1 p. EF v3.1 climate change 1.021e+04 kg CO2 eq (Monte Carlo 95 % interval 9084–1.295e+04). Main contributors: Refrigerant R134a, at plant 32 %; Heat storage 2000l, at plant 22 %; Compressor Bitzer 15 %; Plate heat exchanger 15 %; Aluminium, primary, at plant 5 %; 1,1,1,2-Tetrafluoroethane 4 %. Status: final control passed.
| Item | Value |
|---|---|
| Dataset name | Heat pump Limmatschulhaus |
| Dataset UUID / graph id | 7bd453ee-28f2-32c2-9878-20a82ed297da / activity:heat_pump_limmatschulhaus__ch |
| Reference product, unit | Heat pump Limmatschulhaus, 1 p |
| Location | CH — This data represent the assembling in Switzerland. |
| Time period | 2004-01/2004-12 |
| Category | energy supply, kbob recommendation / heat pumps, waste water |
| Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 |
| Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) |
| Background database | BAFU 2026 v1 (graph bafuquery-db) |
| LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) |
| Status | final control passed |
| Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 |
Introduction
This data set describes . Data regarding to assembly stems from company data, requirements of working materials from literature. Transport distances are estimated.; UUID: 7bd453ee-28f2-32c2-9878-20a82ed297da
This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.
Goal and scope
Function, functional unit and reference flow
Reference flow: 1 p of Heat pump Limmatschulhaus (CH). All results are given per unit of the reference flow.
System boundary
This data set includes the assembling of the heat pump as well as the refrigerant emissions when filling the equipment and transports of components.
Technology
Data set for a brine-water heat pump.
Link to the background database
Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).
LCIA method
EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.
Life cycle inventory
Inventory table
Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).
| Exchange | Type | Location / compartment | Amount | Unit | Uncertainty | Pedigree | GWP share (%) | Notes | |
|---|---|---|---|---|---|---|---|---|---|
| Refrigerant R134a, at plant | technosphere | RER | 30 | kg | lognormal, GSD² 1.23 | (2,3,2,1,3,3) | 31.9 | ██████ | |
| Heat storage 2000l, at plant | technosphere | CH | 2.44 | p | lognormal, GSD² 1.31 | (4,3,2,1,3,3) | 21.6 | ████ | |
| Compressor Bitzer | technosphere | DE | 500 | kg | lognormal, GSD² 1.23 | (2,3,2,1,3,3) | 15.4 | ███ | |
| Plate heat exchanger | technosphere | CH | 525 | kg | lognormal, GSD² 1.23 | (2,3,2,1,3,3) | 14.7 | ███ | |
| Aluminium, primary, at plant | technosphere | RER | 54.645 | kg | lognormal, GSD² 1.23 | (1,3,2,1,3,3) | 4.8 | █ | |
| Cabinet panel | technosphere | CH | 14.044 | m2 | lognormal, GSD² 1.23 | (1,3,2,1,3,3) | 2.4 | · | |
| Transport, freight, lorry, 16t-32t gross weight, fleet average | technosphere | CH | 707.65 | tkm | lognormal, GSD² 2.06 | (1,3,2,1,3,3) | 1.2 | · | |
| Reinforcing steel, at plant | technosphere | RER | 57.377 | kg | lognormal, GSD² 1.23 | (1,3,2,1,3,3) | 0.8 | · | |
| Transport, freight, lorry, 7.5t-16t gross weight, fleet average | technosphere | CH | 234.97 | tkm | lognormal, GSD² 2.06 | (1,3,2,1,3,3) | 0.7 | · | |
| Refrigerant collector | technosphere | DE | 19.126 | kg | lognormal, GSD² 1.23 | (1,3,2,1,3,3) | 0.5 | · | |
| Disposal, plastics, mixture, 15.3% water, to municipal incineration | technosphere | CH | 19.126 | kg | lognormal, GSD² 1.23 | (1,3,2,1,3,3) | 0.4 | · | |
| Circulation pump | technosphere | RER | 12.295 | kg | lognormal, GSD² 1.23 | (1,3,2,1,3,3) | 0.4 | · | |
| Transport, freight, lorry, 3.5t gross weight, fleet average | technosphere | CH | 24 | tkm | lognormal, GSD² 2.1 | (4,3,2,1,3,3) | 0.3 | · | |
| Electricity, low voltage, at grid | technosphere | CH | 204.92 | kWh | lognormal, GSD² 1.23 | (1,3,2,1,3,3) | 0.2 | · | |
| Copper, at regional storage | technosphere | RER | 10.383 | kg | lognormal, GSD² 1.23 | (1,3,2,1,3,3) | 0.2 | · | |
| Synthetic rubber, at plant | technosphere | RER | 2.1858 | kg | lognormal, GSD² 1.23 | (1,3,2,1,3,3) | 0.1 | · | |
| Acetylene, at regional storehouse | technosphere | CH | 2.4317 | kg | lognormal, GSD² 1.23 | (1,3,2,1,3,3) | 0.0 | · | |
| Tube insulation, elastomere, at plant | technosphere | DE | 0.38251 | kg | lognormal, GSD² 1.23 | (1,3,2,1,3,3) | 0.0 | · | |
| Nitrogen, liquid, at plant | technosphere | RER | 6.8306 | kg | lognormal, GSD² 1.23 | (1,3,2,1,3,3) | 0.0 | · | |
| Brazing solder, cadmium free, at plant | technosphere | RER | 0.38251 | kg | lognormal, GSD² 1.23 | (1,3,2,1,3,3) | 0.0 | · | |
| Oxygen, liquid, at plant | technosphere | RER | 3.5519 | kg | lognormal, GSD² 1.23 | (1,3,2,1,3,3) | 0.0 | · | |
| 1,1,1,2-Tetrafluoroethane | elementary | air/Ground level / Urban (>1000 people/s… | 0.3 | kg | lognormal, GSD² 1.57 | (1,3,2,1,3,3) | 4.5 | █ | |
| Carbon Dioxide (fossil) | elementary | air/Ground level / Urban (>1000 people/s… | 4.1257 | kg | lognormal, GSD² 1.23 | (1,3,2,1,3,3) | 0.0 | · |
Data quality
23 of 23 direct exchanges carry a declared pedigree, 23 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 1.39 · completeness 3.0 · temporal 2.0 · geographical 1.0 · technological 3.0 · sample size 3.0.
| Field | As declared by the publisher |
|---|---|
| Data generator / entry / validation | data generator: Matthias Tuchschmid; data entry: Matthias Tuchschmid; validation (proof reading): Rolf Frischknecht (TREEZE) |
| extrapolations | Extrapolated from a 50 kW heat pump |
| sampling procedure | literature |
| production volume | na |
| uncertainty adjustments | none |
| validation details | Proof reading validation: automatic validation in Excel; Other validation: none; |
| time period comment | Data for refrigerant use, quantity of compressors and total material is actual data from questionnaire, rest of data is estimated from literature data. |
Data gaps, proxies and assumptions
None recorded.
Life cycle impact assessment (EF v3.1)
Per 1 p. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.
| Impact category | Indicator | Unit | Result | 2.5 % | 97.5 % | GSD² |
|---|---|---|---|---|---|---|
| Acidification | Accumulated Exceedance (AE) | mol H+ eq | 61.94 | 53.09 | 83.24 | 1.26 |
| Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | 18.43 | 12.76 | 40.76 | 1.78 |
| Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | 1.019e+04 | 9061 | 1.292e+04 | 1.21 |
| Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | 3.328 | 2.784 | 4.888 | 1.32 |
| Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | 1.021e+04 | 9084 | 1.295e+04 | 1.21 |
| EF-particulate Matter | Impact on human health | disease incidence | 4.975e-04 | 4.479e-04 | 7.336e-04 | 1.29 |
| Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | 3.051e+04 | 2.905e+04 | 5.996e+04 | 1.47 |
| Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | 840.7 | 780.1 | 3224 | 2.23 |
| Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | 3.135e+04 | 3.025e+04 | 6.183e+04 | 1.48 |
| Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | 7.839 | 7.091 | 11.42 | 1.3 |
| Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | 14.74 | 9.293 | 86.56 | 3.19 |
| Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | 82.24 | 72.03 | 114.3 | 1.26 |
| Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | 9.193e-06 | 8.665e-06 | 2.137e-05 | 1.6 |
| Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | 3.839e-06 | 3.435e-06 | 5.628e-06 | 1.3 |
| Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | 1.303e-05 | 1.258e-05 | 2.552e-05 | 1.45 |
| Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | 6.508e-04 | 5.409e-04 | 0.00169 | 1.77 |
| Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | 4.189e-05 | 2.603e-05 | 7.648e-05 | 1.75 |
| Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | 6.927e-04 | 5.907e-04 | 0.001733 | 1.73 |
| Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | 2403 | 889.7 | 1.363e+04 | 4.21 |
| Land use | Soil quality index | pt (soil quality index) | 6.591e+04 | 5.889e+04 | 9.506e+04 | 1.29 |
| Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | 0.2533 | 0.137 | 0.4913 | 1.96 |
| Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | 30.09 | 27.72 | 42.63 | 1.24 |
| Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | 8.541e+04 | 7.867e+04 | 1.150e+05 | 1.22 |
| Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | 0.3508 | 0.2993 | 0.443 | 1.22 |
| Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | 662.3 | -4.431e+06 | 2.245e+06 | — |
Climate change 1.021e+04 kg CO2 eq per p. Main contributors: Refrigerant R134a, at plant 32 %; Heat storage 2000l, at plant 22 %; Compressor Bitzer 15 %; Plate heat exchanger 15 %; Aluminium, primary, at plant 5 %; 1,1,1,2-Tetrafluoroethane 4 %.
Interpretation
Significant issues
Direct exchanges dominating climate change: Refrigerant R134a, at plant 32 %; Heat storage 2000l, at plant 22 %; Compressor Bitzer 15 %; Plate heat exchanger 15 %; Aluminium, primary, at plant 5 %; 1,1,1,2-Tetrafluoroethane 4 %. Most sensitive exchanges (Section 6.3): Refrigerant R134a, at plant [RER] (-5.9 / +7.2 %); Heat storage 2000l, at plant [CH] (-5.1 / +6.6 %); Compressor Bitzer [DE] (-2.8 / +3.5 %).
Independent recalculation
Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026):
| Category | Graph | Published | Graph / published |
|---|---|---|---|
| Acidification | 61.94 | 64.82 | 0.956 |
| Climate change-Biogenic | 18.43 | 18.43 | 1.000 |
| Climate change-Fossil | 1.019e+04 | 1.019e+04 | 1.000 |
| Climate change-Land use and land use change | 3.328 | 3.328 | 1.000 |
| Climate change | 1.021e+04 | 1.021e+04 | 1.000 |
| EF-particulate Matter | 4.975e-04 | 4.975e-04 | 1.000 |
| Ecotoxicity, freshwater_inorganics | 3.051e+04 | 3.169e+04 | 0.963 |
| Ecotoxicity, freshwater_organics | 840.7 | 835.6 | 1.006 |
| Ecotoxicity, freshwater | 3.135e+04 | 3.25e+04 | 0.964 |
| Eutrophication marine | 7.839 | 7.838 | 1.000 |
| Eutrophication, freshwater | 14.74 | 14.74 | 1.000 |
| Eutrophication, terrestrial | 82.24 | 85.48 | 0.962 |
| Human toxicity, cancer_inorganics | 9.193e-06 | 9.163e-06 | 1.003 |
| Human toxicity, cancer_organics | 3.839e-06 | 3.839e-06 | 1.000 |
| Human toxicity, cancer | 1.303e-05 | 1.300e-05 | 1.002 |
| Human toxicity, non-cancer_inorganics | 6.508e-04 | 6.495e-04 | 1.002 |
| Human toxicity, non-cancer_organics | 4.189e-05 | 4.189e-05 | 1.000 |
| Human toxicity, non-cancer | 6.927e-04 | 6.913e-04 | 1.002 |
| Ionising radiation, human health | 2403 | 2403 | 1.000 |
| Land use | 6.591e+04 | 4.26e+04 | 1.547 |
| Ozone depletion | 0.2533 | 0.2533 | 1.000 |
| Photochemical ozone formation - human health | 30.09 | 30.09 | 1.000 |
| Resource use, fossils | 8.541e+04 | 8.543e+04 | 1.000 |
| Resource use, minerals and metals | 0.3508 | 0.3467 | 1.012 |
| Water use | 662.3 | 725.2 | 0.913 |
| Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | |||
| Also published by BAFU for this dataset: IPCC 2021 GWP100 1.021e+04 kg CO2 eq; Ecological Scarcity | |||
| 2021 total 2.695e+07 UBP. |
Sensitivity check
One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.
| Exchange | Base | Low / high | Range | Δ GWP100 (%) | Δ other categories (max %) |
|---|---|---|---|---|---|
| Refrigerant R134a, at plant [RER] | 30 kg | ×0.815 / ×1.23 | lognormal, GSD² 1.23 | -5.9 / +7.2 | 22.7 (Ozone depletion) |
| Heat storage 2000l, at plant [CH] | 2.44 p | ×0.765 / ×1.31 | lognormal, GSD² 1.31 | -5.1 / +6.6 | 17.8 (Land use) |
| Compressor Bitzer [DE] | 500 kg | ×0.815 / ×1.23 | lognormal, GSD² 1.23 | -2.8 / +3.5 | 10.1 (Climate change-Land use and land use change) |
| Plate heat exchanger [CH] | 525 kg | ×0.815 / ×1.23 | lognormal, GSD² 1.23 | -2.7 / +3.3 | 14.4 (Human toxicity, non-cancer_organics) |
| 1,1,1,2-Tetrafluoroethane [air/Ground level / Urban (>1000 people/square mile)] | 0.3 kg | ×0.643 / ×1.56 | lognormal, GSD² 1.57 | -1.6 / +2.5 | 2.5 (Climate change-Fossil) |
| Aluminium, primary, at plant [RER] | 54.65 kg | ×0.82 / ×1.22 | lognormal, GSD² 1.23 | -0.9 / +1.1 | 4.6 (Climate change-Land use and land use change) |
| Transport, freight, lorry, 16t-32t gross weight, fleet average [CH] | 707.6 tkm | ×0.493 / ×2.03 | lognormal, GSD² 2.06 | -0.6 / +1.2 | 3.0 (Ecotoxicity, freshwater_organics) |
| Transport, freight, lorry, 7.5t-16t gross weight, fleet average [CH] | 235 tkm | ×0.493 / ×2.03 | lognormal, GSD² 2.06 | -0.3 / +0.7 | 1.5 (Ecotoxicity, freshwater_organics) |
| Cabinet panel [CH] | 14.04 m2 | ×0.82 / ×1.22 | lognormal, GSD² 1.23 | -0.4 / +0.5 | 2.2 (Ecotoxicity, freshwater_organics) |
| Transport, freight, lorry, 3.5t gross weight, fleet average [CH] | 24 tkm | ×0.483 / ×2.07 | lognormal, GSD² 2.1 | -0.1 / +0.3 | 1.0 (Ecotoxicity, freshwater_organics) |
| Reinforcing steel, at plant [RER] | 57.38 kg | ×0.82 / ×1.22 | lognormal, GSD² 1.23 | -0.1 / +0.2 | 0.4 (Water use) |
| Refrigerant collector [DE] | 19.13 kg | ×0.82 / ×1.22 | lognormal, GSD² 1.23 | -0.1 / +0.1 | 0.2 (Ionising radiation, human health) |
| Disposal, plastics, mixture, 15.3% water, to municipal incineration [CH] | 19.13 kg | ×0.82 / ×1.22 | lognormal, GSD² 1.23 | -0.1 / +0.1 | 0.1 (Water use) |
| Circulation pump [RER] | 12.29 kg | ×0.82 / ×1.22 | lognormal, GSD² 1.23 | -0.1 / +0.1 | 0.3 (Resource use, minerals and metals) |
| Electricity, low voltage, at grid [CH] | 204.9 kWh | ×0.82 / ×1.22 | lognormal, GSD² 1.23 | -0.0 / +0.0 | 1.3 (Ionising radiation, human health) |
Uncertainty analysis
Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.
Comparison with other data
No other location of this dataset in the graph.
Conclusions and limitations
GWP100 1.021e+04 kg CO2 eq per p (95 % interval 9084–1.295e+04). Dominant contributors: Refrigerant R134a, at plant 32 %; Heat storage 2000l, at plant 22 %; Compressor Bitzer 15 %; Plate heat exchanger 15 %; Aluminium, primary, at plant 5 %; 1,1,1,2-Tetrafluoroethane 4 %. Most sensitive: Refrigerant R134a, at plant [RER] (-5.9 / +7.2 %); Heat storage 2000l, at plant [CH] (-5.1 / +6.6 %); Compressor Bitzer [DE] (-2.8 / +3.5 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.
Final control
| Item | Status | Detail |
|---|---|---|
| reference flow | PASS | production amount 1.0 p |
| closure: sum of direct contributions = dataset score (all 25 categories) | PASS | largest relative gap 2.2e-16 |
| independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) | PASS | graph / published = 0.9997; categories within ±5 %: 23/25 |
| every technosphere input of the EcoSpold delivery is in the graph | PASS | all present (bafu_links_check.py) |
| uncertainty declared on the direct exchanges | PASS | 23/23 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values |
| Monte Carlo 95 % interval contains the deterministic score | PASS | 1.021e+04 in [9084, 1.295e+04] |
| time period declared | PASS | 2004-01/2004-12 |
| geography is a known location code | PASS | CH |
| sources cited | PASS | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them |
References
- Rolf Frischknecht, Mireille Faist Emmenegger (2004) Nutzwärmebereitstellung mit Wärmepumpe für Rohabwasser. Uster. Type: Separate publication Source: Interner Bericht First author: Rolf Frischknecht Other authors: Mireille Faist Emmenegger Year: 2004 Place of publication: Uster — published source; as declared by BAFU (not found in OpenAlex/Crossref)
- Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — database; dataset citation
- International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva.
- Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. (tdc-doc method reference; title, version and year to verify against the user's copy)
- European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra.
- Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236
Annex — licence and terms of use
BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.
To suggest a correction or a dataset that does not exist yet, use Propose a dataset.