Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Heat pump Limmatschulhaus [CH], per 1 p. EF v3.1 climate change 1.021e+04 kg CO2 eq (Monte Carlo 95 % interval 9084–1.295e+04). Main contributors: Refrigerant R134a, at plant 32 %; Heat storage 2000l, at plant 22 %; Compressor Bitzer 15 %; Plate heat exchanger 15 %; Aluminium, primary, at plant 5 %; 1,1,1,2-Tetrafluoroethane 4 %. Status: final control passed.
Item Value
Dataset name Heat pump Limmatschulhaus
Dataset UUID / graph id 7bd453ee-28f2-32c2-9878-20a82ed297da / activity:heat_pump_limmatschulhaus__ch
Reference product, unit Heat pump Limmatschulhaus, 1 p
Location CH — This data represent the assembling in Switzerland.
Time period 2004-01/2004-12
Category energy supply, kbob recommendation / heat pumps, waste water
Source database BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1
Publisher Swiss Federal Office for the Environment (FOEN/BAFU)
Background database BAFU 2026 v1 (graph bafuquery-db)
LCIA method EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix)
Status final control passed
Documented by tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17

Introduction

This data set describes . Data regarding to assembly stems from company data, requirements of working materials from literature. Transport distances are estimated.; UUID: 7bd453ee-28f2-32c2-9878-20a82ed297da

This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.

Goal and scope

Function, functional unit and reference flow

Reference flow: 1 p of Heat pump Limmatschulhaus (CH). All results are given per unit of the reference flow.

System boundary

This data set includes the assembling of the heat pump as well as the refrigerant emissions when filling the equipment and transports of components.

Technology

Data set for a brine-water heat pump.

Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).

LCIA method

EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.

Life cycle inventory

Inventory table

Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).

Exchange Type Location / compartment Amount Unit Uncertainty Pedigree GWP share (%) Notes
Refrigerant R134a, at plant technosphere RER 30 kg lognormal, GSD² 1.23 (2,3,2,1,3,3) 31.9 ██████
Heat storage 2000l, at plant technosphere CH 2.44 p lognormal, GSD² 1.31 (4,3,2,1,3,3) 21.6 ████
Compressor Bitzer technosphere DE 500 kg lognormal, GSD² 1.23 (2,3,2,1,3,3) 15.4 ███
Plate heat exchanger technosphere CH 525 kg lognormal, GSD² 1.23 (2,3,2,1,3,3) 14.7 ███
Aluminium, primary, at plant technosphere RER 54.645 kg lognormal, GSD² 1.23 (1,3,2,1,3,3) 4.8 █
Cabinet panel technosphere CH 14.044 m2 lognormal, GSD² 1.23 (1,3,2,1,3,3) 2.4 ·
Transport, freight, lorry, 16t-32t gross weight, fleet average technosphere CH 707.65 tkm lognormal, GSD² 2.06 (1,3,2,1,3,3) 1.2 ·
Reinforcing steel, at plant technosphere RER 57.377 kg lognormal, GSD² 1.23 (1,3,2,1,3,3) 0.8 ·
Transport, freight, lorry, 7.5t-16t gross weight, fleet average technosphere CH 234.97 tkm lognormal, GSD² 2.06 (1,3,2,1,3,3) 0.7 ·
Refrigerant collector technosphere DE 19.126 kg lognormal, GSD² 1.23 (1,3,2,1,3,3) 0.5 ·
Disposal, plastics, mixture, 15.3% water, to municipal incineration technosphere CH 19.126 kg lognormal, GSD² 1.23 (1,3,2,1,3,3) 0.4 ·
Circulation pump technosphere RER 12.295 kg lognormal, GSD² 1.23 (1,3,2,1,3,3) 0.4 ·
Transport, freight, lorry, 3.5t gross weight, fleet average technosphere CH 24 tkm lognormal, GSD² 2.1 (4,3,2,1,3,3) 0.3 ·
Electricity, low voltage, at grid technosphere CH 204.92 kWh lognormal, GSD² 1.23 (1,3,2,1,3,3) 0.2 ·
Copper, at regional storage technosphere RER 10.383 kg lognormal, GSD² 1.23 (1,3,2,1,3,3) 0.2 ·
Synthetic rubber, at plant technosphere RER 2.1858 kg lognormal, GSD² 1.23 (1,3,2,1,3,3) 0.1 ·
Acetylene, at regional storehouse technosphere CH 2.4317 kg lognormal, GSD² 1.23 (1,3,2,1,3,3) 0.0 ·
Tube insulation, elastomere, at plant technosphere DE 0.38251 kg lognormal, GSD² 1.23 (1,3,2,1,3,3) 0.0 ·
Nitrogen, liquid, at plant technosphere RER 6.8306 kg lognormal, GSD² 1.23 (1,3,2,1,3,3) 0.0 ·
Brazing solder, cadmium free, at plant technosphere RER 0.38251 kg lognormal, GSD² 1.23 (1,3,2,1,3,3) 0.0 ·
Oxygen, liquid, at plant technosphere RER 3.5519 kg lognormal, GSD² 1.23 (1,3,2,1,3,3) 0.0 ·
1,1,1,2-Tetrafluoroethane elementary air/Ground level / Urban (>1000 people/s… 0.3 kg lognormal, GSD² 1.57 (1,3,2,1,3,3) 4.5 █
Carbon Dioxide (fossil) elementary air/Ground level / Urban (>1000 people/s… 4.1257 kg lognormal, GSD² 1.23 (1,3,2,1,3,3) 0.0 ·

Data quality

23 of 23 direct exchanges carry a declared pedigree, 23 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 1.39 · completeness 3.0 · temporal 2.0 · geographical 1.0 · technological 3.0 · sample size 3.0.

Field As declared by the publisher
Data generator / entry / validation data generator: Matthias Tuchschmid; data entry: Matthias Tuchschmid; validation (proof reading): Rolf Frischknecht (TREEZE)
extrapolations Extrapolated from a 50 kW heat pump
sampling procedure literature
production volume na
uncertainty adjustments none
validation details Proof reading validation: automatic validation in Excel; Other validation: none;
time period comment Data for refrigerant use, quantity of compressors and total material is actual data from questionnaire, rest of data is estimated from literature data.

Data gaps, proxies and assumptions

None recorded.

Life cycle impact assessment (EF v3.1)

Per 1 p. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.

Impact category Indicator Unit Result 2.5 % 97.5 % GSD²
Acidification Accumulated Exceedance (AE) mol H+ eq 61.94 53.09 83.24 1.26
Climate change-Biogenic Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 18.43 12.76 40.76 1.78
Climate change-Fossil Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 1.019e+04 9061 1.292e+04 1.21
Climate change-Land use and land use change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 3.328 2.784 4.888 1.32
Climate change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 1.021e+04 9084 1.295e+04 1.21
EF-particulate Matter Impact on human health disease incidence 4.975e-04 4.479e-04 7.336e-04 1.29
Ecotoxicity, freshwater_inorganics Comparative Toxic Unit for ecosystems (CTUe) CTUe 3.051e+04 2.905e+04 5.996e+04 1.47
Ecotoxicity, freshwater_organics Comparative Toxic Unit for ecosystems (CTUe) CTUe 840.7 780.1 3224 2.23
Ecotoxicity, freshwater Comparative Toxic Unit for ecosystems (CTUe) CTUe 3.135e+04 3.025e+04 6.183e+04 1.48
Eutrophication marine Fraction of nutrients reaching marine end compartment (N) kg N eq 7.839 7.091 11.42 1.3
Eutrophication, freshwater Fraction of nutrients reaching freshwater end compartment (P) kg P eq 14.74 9.293 86.56 3.19
Eutrophication, terrestrial Accumulated Exceedance (AE) mol N eq 82.24 72.03 114.3 1.26
Human toxicity, cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 9.193e-06 8.665e-06 2.137e-05 1.6
Human toxicity, cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 3.839e-06 3.435e-06 5.628e-06 1.3
Human toxicity, cancer Comparative Toxic Unit for human (CTUh) CTUh 1.303e-05 1.258e-05 2.552e-05 1.45
Human toxicity, non-cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 6.508e-04 5.409e-04 0.00169 1.77
Human toxicity, non-cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 4.189e-05 2.603e-05 7.648e-05 1.75
Human toxicity, non-cancer Comparative Toxic Unit for human (CTUh) CTUh 6.927e-04 5.907e-04 0.001733 1.73
Ionising radiation, human health Human exposure efficiency relative to U235 kBq U235 eq 2403 889.7 1.363e+04 4.21
Land use Soil quality index pt (soil quality index) 6.591e+04 5.889e+04 9.506e+04 1.29
Ozone depletion Ozone Depletion Potential (ODP) kg CFC-11 eq 0.2533 0.137 0.4913 1.96
Photochemical ozone formation - human health Tropospheric ozone concentration increase kg NMVOC eq 30.09 27.72 42.63 1.24
Resource use, fossils Abiotic resource depletion fossil fuels (ADP-fossil) MJ 8.541e+04 7.867e+04 1.150e+05 1.22
Resource use, minerals and metals Abiotic resource depletion (ADP ultimate reserve) kg Sb eq 0.3508 0.2993 0.443 1.22
Water use User deprivation potential (deprivation-weighted water consumption) m3 world eq deprived 662.3 -4.431e+06 2.245e+06 —

Climate change 1.021e+04 kg CO2 eq per p. Main contributors: Refrigerant R134a, at plant 32 %; Heat storage 2000l, at plant 22 %; Compressor Bitzer 15 %; Plate heat exchanger 15 %; Aluminium, primary, at plant 5 %; 1,1,1,2-Tetrafluoroethane 4 %.

Interpretation

Significant issues

Direct exchanges dominating climate change: Refrigerant R134a, at plant 32 %; Heat storage 2000l, at plant 22 %; Compressor Bitzer 15 %; Plate heat exchanger 15 %; Aluminium, primary, at plant 5 %; 1,1,1,2-Tetrafluoroethane 4 %. Most sensitive exchanges (Section 6.3): Refrigerant R134a, at plant [RER] (-5.9 / +7.2 %); Heat storage 2000l, at plant [CH] (-5.1 / +6.6 %); Compressor Bitzer [DE] (-2.8 / +3.5 %).

Independent recalculation

Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026):

Category Graph Published Graph / published
Acidification 61.94 64.82 0.956
Climate change-Biogenic 18.43 18.43 1.000
Climate change-Fossil 1.019e+04 1.019e+04 1.000
Climate change-Land use and land use change 3.328 3.328 1.000
Climate change 1.021e+04 1.021e+04 1.000
EF-particulate Matter 4.975e-04 4.975e-04 1.000
Ecotoxicity, freshwater_inorganics 3.051e+04 3.169e+04 0.963
Ecotoxicity, freshwater_organics 840.7 835.6 1.006
Ecotoxicity, freshwater 3.135e+04 3.25e+04 0.964
Eutrophication marine 7.839 7.838 1.000
Eutrophication, freshwater 14.74 14.74 1.000
Eutrophication, terrestrial 82.24 85.48 0.962
Human toxicity, cancer_inorganics 9.193e-06 9.163e-06 1.003
Human toxicity, cancer_organics 3.839e-06 3.839e-06 1.000
Human toxicity, cancer 1.303e-05 1.300e-05 1.002
Human toxicity, non-cancer_inorganics 6.508e-04 6.495e-04 1.002
Human toxicity, non-cancer_organics 4.189e-05 4.189e-05 1.000
Human toxicity, non-cancer 6.927e-04 6.913e-04 1.002
Ionising radiation, human health 2403 2403 1.000
Land use 6.591e+04 4.26e+04 1.547
Ozone depletion 0.2533 0.2533 1.000
Photochemical ozone formation - human health 30.09 30.09 1.000
Resource use, fossils 8.541e+04 8.543e+04 1.000
Resource use, minerals and metals 0.3508 0.3467 1.012
Water use 662.3 725.2 0.913
Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like.
Also published by BAFU for this dataset: IPCC 2021 GWP100 1.021e+04 kg CO2 eq; Ecological Scarcity
2021 total 2.695e+07 UBP.

Sensitivity check

One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.

Exchange Base Low / high Range Δ GWP100 (%) Δ other categories (max %)
Refrigerant R134a, at plant [RER] 30 kg ×0.815 / ×1.23 lognormal, GSD² 1.23 -5.9 / +7.2 22.7 (Ozone depletion)
Heat storage 2000l, at plant [CH] 2.44 p ×0.765 / ×1.31 lognormal, GSD² 1.31 -5.1 / +6.6 17.8 (Land use)
Compressor Bitzer [DE] 500 kg ×0.815 / ×1.23 lognormal, GSD² 1.23 -2.8 / +3.5 10.1 (Climate change-Land use and land use change)
Plate heat exchanger [CH] 525 kg ×0.815 / ×1.23 lognormal, GSD² 1.23 -2.7 / +3.3 14.4 (Human toxicity, non-cancer_organics)
1,1,1,2-Tetrafluoroethane [air/Ground level / Urban (>1000 people/square mile)] 0.3 kg ×0.643 / ×1.56 lognormal, GSD² 1.57 -1.6 / +2.5 2.5 (Climate change-Fossil)
Aluminium, primary, at plant [RER] 54.65 kg ×0.82 / ×1.22 lognormal, GSD² 1.23 -0.9 / +1.1 4.6 (Climate change-Land use and land use change)
Transport, freight, lorry, 16t-32t gross weight, fleet average [CH] 707.6 tkm ×0.493 / ×2.03 lognormal, GSD² 2.06 -0.6 / +1.2 3.0 (Ecotoxicity, freshwater_organics)
Transport, freight, lorry, 7.5t-16t gross weight, fleet average [CH] 235 tkm ×0.493 / ×2.03 lognormal, GSD² 2.06 -0.3 / +0.7 1.5 (Ecotoxicity, freshwater_organics)
Cabinet panel [CH] 14.04 m2 ×0.82 / ×1.22 lognormal, GSD² 1.23 -0.4 / +0.5 2.2 (Ecotoxicity, freshwater_organics)
Transport, freight, lorry, 3.5t gross weight, fleet average [CH] 24 tkm ×0.483 / ×2.07 lognormal, GSD² 2.1 -0.1 / +0.3 1.0 (Ecotoxicity, freshwater_organics)
Reinforcing steel, at plant [RER] 57.38 kg ×0.82 / ×1.22 lognormal, GSD² 1.23 -0.1 / +0.2 0.4 (Water use)
Refrigerant collector [DE] 19.13 kg ×0.82 / ×1.22 lognormal, GSD² 1.23 -0.1 / +0.1 0.2 (Ionising radiation, human health)
Disposal, plastics, mixture, 15.3% water, to municipal incineration [CH] 19.13 kg ×0.82 / ×1.22 lognormal, GSD² 1.23 -0.1 / +0.1 0.1 (Water use)
Circulation pump [RER] 12.29 kg ×0.82 / ×1.22 lognormal, GSD² 1.23 -0.1 / +0.1 0.3 (Resource use, minerals and metals)
Electricity, low voltage, at grid [CH] 204.9 kWh ×0.82 / ×1.22 lognormal, GSD² 1.23 -0.0 / +0.0 1.3 (Ionising radiation, human health)

Uncertainty analysis

Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.

Comparison with other data

No other location of this dataset in the graph.

Conclusions and limitations

GWP100 1.021e+04 kg CO2 eq per p (95 % interval 9084–1.295e+04). Dominant contributors: Refrigerant R134a, at plant 32 %; Heat storage 2000l, at plant 22 %; Compressor Bitzer 15 %; Plate heat exchanger 15 %; Aluminium, primary, at plant 5 %; 1,1,1,2-Tetrafluoroethane 4 %. Most sensitive: Refrigerant R134a, at plant [RER] (-5.9 / +7.2 %); Heat storage 2000l, at plant [CH] (-5.1 / +6.6 %); Compressor Bitzer [DE] (-2.8 / +3.5 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.

Final control

Item Status Detail
reference flow PASS production amount 1.0 p
closure: sum of direct contributions = dataset score (all 25 categories) PASS largest relative gap 2.2e-16
independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) PASS graph / published = 0.9997; categories within ±5 %: 23/25
every technosphere input of the EcoSpold delivery is in the graph PASS all present (bafu_links_check.py)
uncertainty declared on the direct exchanges PASS 23/23 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values
Monte Carlo 95 % interval contains the deterministic score PASS 1.021e+04 in [9084, 1.295e+04]
time period declared PASS 2004-01/2004-12
geography is a known location code PASS CH
sources cited PASS 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them

References

  1. Rolf Frischknecht, Mireille Faist Emmenegger (2004) Nutzwärmebereitstellung mit Wärmepumpe für Rohabwasser. Uster. Type: Separate publication Source: Interner Bericht First author: Rolf Frischknecht Other authors: Mireille Faist Emmenegger Year: 2004 Place of publication: Uster — published source; as declared by BAFU (not found in OpenAlex/Crossref)
  2. Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — database; dataset citation
  3. International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva.
  4. Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. (tdc-doc method reference; title, version and year to verify against the user's copy)
  5. European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra.
  6. Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236

Annex — licence and terms of use

BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.


To suggest a correction or a dataset that does not exist yet, use Propose a dataset.

datasets/bafu/7bd453ee-28f2-32c2-9878-20a82ed297da.txt · Last modified: by 127.0.0.1

Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki