xxx Electricity, production mix IS — IS

Dataset documentation and final control (tdc-doc, imported mode)
Open this dataset in OpenData

Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset xxx Electricity, production mix IS [IS], per 1 kWh. EF v3.1 climate change 0.01579 kg CO2 eq (Monte Carlo 95 % interval 0.01126–0.0315). Main contributors: Electricity, hydropower, at reservoir power plant, non alpin… 78 %; Electricity, at wind farm 21 %. Status: final control passed.
Item Value
Dataset name xxx Electricity, production mix IS
Dataset UUID / graph id 819a3b92-eeba-381d-9784-b7a0f016ed0d / activity:xxx_electricity_production_mix_is__is
Reference product, unit xxx Electricity, production mix IS, 1 kWh
Location IS — Data apply to public and self producers in Iceland.
Time period 2008-01/2008-12
Category electricity / notMaintained
Source database BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1
Publisher Swiss Federal Office for the Environment (FOEN/BAFU)
Background database BAFU 2026 v1 (graph bafuquery-db)
LCIA method EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix)
Status final control passed
Documented by tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17

Introduction

Electricity domestic net production shares are based on IEA statistics for the year 2008.; UUID: 819a3b92-eeba-381d-9784-b7a0f016ed0d

This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.

Goal and scope

Function, functional unit and reference flow

Reference flow: 1 kWh of xxx Electricity, production mix IS (IS). All results are given per unit of the reference flow.

System boundary

It includes the shares of domestic electricity production by technology at the busbar. It does not include transformation, transport nor distribution losses.

Technology

No technology description is provided because the dataset just describes the power plant portfolio of the respective country using current (2004) average technology per energy carrier.

Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).

LCIA method

EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.

Life cycle inventory

Inventory table

Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).

Exchange Type Location / compartment Amount Unit Uncertainty Pedigree GWP share (%) Notes
Electricity, hydropower, at reservoir power plant, non alpine regions technosphere RER 0.76027 kWh lognormal, GSD² 1.05 (1,1,1,2,1,1) 78.0 ████████████████
Electricity, at wind farm technosphere RER 0.23955 kWh lognormal, GSD² 1.05 (1,1,1,2,1,1) 21.4 ████
Electricity, at cogen 300kWth, diesel, allocation exergy technosphere CH 1.2010e-04 kWh lognormal, GSD² 1.05 (1,1,1,3,1,1) 0.6 ·
Electricity from waste, at municipal waste incineration plant technosphere CH 6.0052e-05 kWh lognormal, GSD² 1.05 (1,1,1,3,1,1) -0.0 ·

Data quality

4 of 4 direct exchanges carry a declared pedigree, 4 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 1.0 · completeness 1.0 · temporal 1.0 · geographical 2.5 · technological 1.0 · sample size 1.0.

Field As declared by the publisher
Data generator / entry / validation data generator: René Itten (ZHAW); data entry: René Itten (ZHAW); validation (proof reading): Rolf Frischknecht (TREEZE)
extrapolations none
sampling procedure Statistical data
production volume 16 TWh
uncertainty adjustments none
validation details Proof reading validation: automatic validation in Excel; Other validation: Z:\ESU-Docs\Projekte laufend\401 Update Strommix v3.0\EcoSpold_Europa[401-electricity-mix-iceland-IS-v1.0.xlsx]X-Process;
time period comment Time period of statistics used (2008).

Data gaps, proxies and assumptions

None recorded.

Life cycle impact assessment (EF v3.1)

Per 1 kWh. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.

Impact category Indicator Unit Result 2.5 % 97.5 % GSD²
Acidification Accumulated Exceedance (AE) mol H+ eq 2.718e-05 2.342e-05 5.701e-05 1.6
Climate change-Biogenic Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 9.952e-04 4.313e-04 0.002237 2.33
Climate change-Fossil Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.006563 0.004586 0.01813 2
Climate change-Land use and land use change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.008227 0.003695 0.01862 2.23
Climate change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.01579 0.01126 0.0315 1.7
EF-particulate Matter Impact on human health disease incidence 4.543e-10 2.845e-10 1.794e-09 2.52
Ecotoxicity, freshwater_inorganics Comparative Toxic Unit for ecosystems (CTUe) CTUe 0.01565 0.01377 0.04763 1.9
Ecotoxicity, freshwater_organics Comparative Toxic Unit for ecosystems (CTUe) CTUe 5.731e-04 5.207e-04 0.002172 2.15
Ecotoxicity, freshwater Comparative Toxic Unit for ecosystems (CTUe) CTUe 0.01622 0.0144 0.04917 1.9
Eutrophication marine Fraction of nutrients reaching marine end compartment (N) kg N eq 7.092e-06 5.769e-06 1.757e-05 1.77
Eutrophication, freshwater Fraction of nutrients reaching freshwater end compartment (P) kg P eq 4.148e-06 2.544e-06 4.204e-05 4.06
Eutrophication, terrestrial Accumulated Exceedance (AE) mol N eq 7.253e-05 5.918e-05 1.763e-04 1.73
Human toxicity, cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 3.144e-12 2.864e-12 1.046e-11 1.92
Human toxicity, cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 3.001e-12 2.271e-12 5.964e-12 1.62
Human toxicity, cancer Comparative Toxic Unit for human (CTUh) CTUh 6.145e-12 5.656e-12 1.556e-11 1.68
Human toxicity, non-cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 1.883e-10 1.598e-10 7.003e-10 2.1
Human toxicity, non-cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 1.084e-11 7.708e-12 2.860e-11 1.95
Human toxicity, non-cancer Comparative Toxic Unit for human (CTUh) CTUh 1.992e-10 1.685e-10 7.179e-10 2.08
Ionising radiation, human health Human exposure efficiency relative to U235 kBq U235 eq 0.001292 4.578e-04 0.009862 5.04
Land use Soil quality index pt (soil quality index) -0.4656 -1.512 -0.08619 —
Ozone depletion Ozone Depletion Potential (ODP) kg CFC-11 eq 1.099e-10 9.175e-11 2.765e-10 1.76
Photochemical ozone formation - human health Tropospheric ozone concentration increase kg NMVOC eq 2.507e-05 2.119e-05 6.360e-05 1.75
Resource use, fossils Abiotic resource depletion fossil fuels (ADP-fossil) MJ 0.06141 0.04855 0.1595 1.82
Resource use, minerals and metals Abiotic resource depletion (ADP ultimate reserve) kg Sb eq 9.480e-08 7.250e-08 2.019e-07 1.67
Water use User deprivation potential (deprivation-weighted water consumption) m3 world eq deprived 4.049e-04 -734.4 425.7 —

Climate change 0.01579 kg CO2 eq per kWh. Main contributors: Electricity, hydropower, at reservoir power plant, non alpin… 78 %; Electricity, at wind farm 21 %.

Interpretation

Significant issues

Direct exchanges dominating climate change: Electricity, hydropower, at reservoir power plant, non alpin… 78 %; Electricity, at wind farm 21 %. Most sensitive exchanges (Section 6.3): Electricity, hydropower, at reservoir power plant, non alpine regions [RER] (-3.7 / +3.9 %); Electricity, at wind farm [RER] (-1.0 / +1.1 %); Electricity, at cogen 300kWth, diesel, allocation exergy [CH] (-0.0 / +0.0 %).

Independent recalculation

Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh:

Category Graph Published Graph / published
Acidification 2.718e-05 3.143e-05 0.865
Climate change-Biogenic 9.952e-04 9.952e-04 1.000
Climate change-Fossil 0.006563 0.006563 1.000
Climate change-Land use and land use change 0.008227 0.008227 1.000
Climate change 0.01579 0.01579 1.000
EF-particulate Matter 4.543e-10 4.543e-10 1.000
Ecotoxicity, freshwater_inorganics 0.01565 0.01618 0.967
Ecotoxicity, freshwater_organics 5.731e-04 5.321e-04 1.077
Ecotoxicity, freshwater 0.01622 0.0167 0.971
Eutrophication marine 7.092e-06 7.091e-06 1.000
Eutrophication, freshwater 4.148e-06 4.148e-06 1.000
Eutrophication, terrestrial 7.253e-05 7.636e-05 0.950
Human toxicity, cancer_inorganics 3.144e-12 3.123e-12 1.007
Human toxicity, cancer_organics 3.001e-12 3.001e-12 1.000
Human toxicity, cancer 6.145e-12 6.124e-12 1.003
Human toxicity, non-cancer_inorganics 1.883e-10 1.876e-10 1.004
Human toxicity, non-cancer_organics 1.084e-11 1.084e-11 1.000
Human toxicity, non-cancer 1.992e-10 1.984e-10 1.004
Ionising radiation, human health 0.001292 0.001292 1.000
Land use -0.4656 -0.4747 0.981
Ozone depletion 1.099e-10 1.099e-10 1.000
Photochemical ozone formation - human health 2.507e-05 2.507e-05 1.000
Resource use, fossils 0.06141 0.06144 1.000
Resource use, minerals and metals 9.480e-08 8.785e-08 1.079
Water use 4.049e-04 5.265e-04 0.769
Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like.
Also published by BAFU for this dataset: IPCC 2021 GWP100 0.01578 kg CO2 eq; Ecological Scarcity
2021 total 52.41 UBP.

Sensitivity check

One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.

Exchange Base Low / high Range Δ GWP100 (%) Δ other categories (max %)
Electricity, hydropower, at reservoir power plant, non alpine regions [RER] 0.7603 kWh ×0.952 / ×1.05 lognormal, GSD² 1.05 -3.7 / +3.9 5.2 (Land use)
Electricity, at wind farm [RER] 0.2396 kWh ×0.952 / ×1.05 lognormal, GSD² 1.05 -1.0 / +1.1 4.1 (Resource use, minerals and metals)
Electricity, at cogen 300kWth, diesel, allocation exergy [CH] 1.201e-04 kWh ×0.95 / ×1.05 lognormal, GSD² 1.05 -0.0 / +0.0 2.7 (Human toxicity, cancer_organics)
Electricity from waste, at municipal waste incineration plant [CH] 6.005e-05 kWh ×0.95 / ×1.05 lognormal, GSD² 1.05 +0.0 / -0.0 0.0 (Water use)

Uncertainty analysis

Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.

Comparison with other data

No other location of this dataset in the graph.

Conclusions and limitations

GWP100 0.01579 kg CO2 eq per kWh (95 % interval 0.01126–0.0315). Dominant contributors: Electricity, hydropower, at reservoir power plant, non alpin… 78 %; Electricity, at wind farm 21 %. Most sensitive: Electricity, hydropower, at reservoir power plant, non alpine regions [RER] (-3.7 / +3.9 %); Electricity, at wind farm [RER] (-1.0 / +1.1 %); Electricity, at cogen 300kWth, diesel, allocation exergy [CH] (-0.0 / +0.0 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.

Final control

Item Status Detail
reference flow PASS production amount 1.0 kWh
closure: sum of direct contributions = dataset score (all 25 categories) PASS largest relative gap 4.4e-16
independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh (climate change) PASS graph / published = 1; categories within ±5 %: 20/25
every technosphere input of the EcoSpold delivery is in the graph PASS all present (bafu_links_check.py)
uncertainty declared on the direct exchanges PASS 4/4 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values
Monte Carlo 95 % interval contains the deterministic score PASS 0.01579 in [0.01126, 0.0315]
time period declared PASS 2008-01/2008-12
geography is a known location code PASS IS
sources cited PASS 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them

References

  1. Itten, R., Frischknecht, R. (2012) Life Cycle Inventories of electricity mixes. Project reports. Volume: 401. ESU-services Ltd.. Uster, CH. Type: Separate publication First author: Itten, R. Other authors: Frischknecht, R. Year: 2012 Title of anthology: Project reports Place of publication: Uster, CH Publisher: ESU-services Ltd. Volume No: 401 — published source; as declared by BAFU (not found in OpenAlex/Crossref)
  2. Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — database; dataset citation
  3. International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva.
  4. Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. (tdc-doc method reference; title, version and year to verify against the user's copy)
  5. European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra.
  6. Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236

Annex — licence and terms of use

BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.


To suggest a correction or a dataset that does not exist yet, use Propose a dataset.

datasets/bafu/819a3b92-eeba-381d-9784-b7a0f016ed0d.txt · Last modified: by 127.0.0.1

Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki