Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Ventilation system, decentralized, 6 x 120 m3/h, PE ducts, without GHE [CH], per 1 p. EF v3.1 climate change 4329 kg CO2 eq (Monte Carlo 95 % interval 4217–5183). Main contributors: Ventilation equipment, decentralized, 180-250 m3/h, at plant 29 %; Silencer, steel, DN 125, at plant 16 %; Air distribution housing, steel, 120 m3/h, at plant 10 %; Ventilation duct, PE corrugated tube, DN 75, at plant 10 %; Disposal, building, polyethylene/polypropylene products, to … 9 %; Supply air inlet, steel, SS, DN 75, at plant 7 %. Status: final control passed.
Item Value
Dataset name Ventilation system, decentralized, 6 x 120 m3/h, PE ducts, without GHE
Dataset UUID / graph id 92bc39b8-4518-3faa-82b5-5b69c5838714 / activity:ventilation_system_decentralized_6_x_120_m3_h_pe_ducts_without_ghe__ch
Reference product, unit Ventilation system, decentralized, 6 x 120 m3/h, PE ducts, without GHE, 1 p
Location CH
Time period 2003-01/2003-12
Category construction / ventilation\components\infrastructure
Source database BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1
Publisher Swiss Federal Office for the Environment (FOEN/BAFU)
Background database BAFU 2026 v1 (graph bafuquery-db)
LCIA method EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix)
Status final control passed
Documented by tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17

Introduction

Ventilation system for a multi family house. The house considered in the investigation includes 6 flats with 130 m2 floor area each and a ventilation rate of 120 m3/h. The influence of a smaller concrete demand due to embedment of ventilation tubes in the concrete of the floor (-4.86 kg concrete per m2 floor area) is not included.; UUID: 92bc39b8-4518-3faa-82b5-5b69c5838714

This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.

Goal and scope

Function, functional unit and reference flow

Reference flow: 1 p of Ventilation system, decentralized, 6 x 120 m3/h, PE ducts, without GHE (CH). All results are given per unit of the reference flow.

System boundary

Materials used for the ventilation system. Transport of the components to the construction site. Disposal of the components included. Influence of ventilation ducts on building construction not included. No materials for renwal of components included. Operation of system not included.

Technology

Decentral ventilation system without ground heat exchanger. Air intake on the facade and direct to the 6 decentral ventilation units with a short galvanised steel tube (125 mm diameter). Distribution of fresh- and exhaust-air within the flat with polyethylene tubes (75 mm diameter). Exhaust air from the 6 decentral ventilation units with a short galvanised steel tube (400 mm diameter) direct to the exhaust on the facade.

Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).

LCIA method

EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.

Life cycle inventory

Inventory table

Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).

Exchange Type Location / compartment Amount Unit Uncertainty Pedigree GWP share (%) Notes
Ventilation equipment, decentralized, 180-250 m3/h, at plant technosphere RER 6 p lognormal, GSD² 1.12 — 29.1 ██████
Silencer, steel, DN 125, at plant technosphere CH 24 p lognormal, GSD² 1.12 — 15.9 ███
Air distribution housing, steel, 120 m3/h, at plant technosphere CH 12 p lognormal, GSD² 1.12 — 9.9 ██
Ventilation duct, PE corrugated tube, DN 75, at plant technosphere RER 400 m lognormal, GSD² 1.12 — 9.7 ██
Disposal, building, polyethylene/polypropylene products, to final disposal technosphere CH 132 kg lognormal, GSD² 1.12 — 9.2 ██
Supply air inlet, steel, SS, DN 75, at plant technosphere RER 30 p lognormal, GSD² 1.12 — 6.6 █
Disposal, ventilation equipment, decentralized, 180-250 m3 technosphere CH 6 p lognormal, GSD² 1.12 — 4.2 █
Exhaust air outlet, steel/aluminum, 85×365 mm, at plant technosphere CH 12 p lognormal, GSD² 1.12 — 3.0 █
Spiral-seam duct, steel, DN 125, at plant technosphere RER 12 m lognormal, GSD² 1.12 — 2.5 █
Control and wiring, decentralized unit, at plant technosphere RER 6 p lognormal, GSD² 1.12 — 2.2 ·
Overflow element, steel, approx. 40 m3/h technosphere RER 18 p lognormal, GSD² 1.12 — 2.0 ·
Transport, freight, lorry, 3.5t gross weight, fleet average technosphere CH 44.1 tkm lognormal, GSD² 2.06 — 1.1 ·
Sealing tape, aluminum/PE, 50 mm wide, at plant technosphere RER 200 m lognormal, GSD² 1.12 — 1.0 ·
Exhaust air valve, in-wall housing, plastic/steel, DN 125, at plant technosphere CH 18 p lognormal, GSD² 1.12 — 0.8 ·
Disposal, sealing tape, aluminum/PE, 50 mm wide technosphere CH 200 m lognormal, GSD² 1.12 — 0.6 ·
Transport, freight, lorry, fleet average technosphere RER 92.1 tkm lognormal, GSD² 2.02 — 0.4 ·
Disposal, overflow element, steel, approx. 40 m3/h technosphere CH 18 p lognormal, GSD² 1.12 — 0.3 ·
Disposal, control and wiring, decentralized unit technosphere CH 6 p lognormal, GSD² 1.12 — 0.3 ·
Air filter, decentralized unit, 180-250 m3/h, at plant technosphere RER 12 p lognormal, GSD² 1.12 — 0.3 ·
Flexible duct, aluminum/PET, DN of 125, at plant technosphere RER 10 m lognormal, GSD² 1.12 — 0.2 ·
Disposal, air distribution housing, steel, 120 m3/h technosphere CH 12 p lognormal, GSD² 1.12 — 0.2 ·
Air filter, in exhaust air valve, at plant technosphere RER 18 p lognormal, GSD² 1.12 — 0.1 ·
Disposal, exhaust air valve, in-wall housing, plastic/steel, DN 125 technosphere CH 18 p lognormal, GSD² 1.12 — 0.1 ·
Disposal, air filter, decentralized unit, 180-250 m3/h technosphere CH 12 p lognormal, GSD² 1.12 — 0.1 ·
Disposal, flexible duct, aluminum/PET, DN of 125 technosphere CH 10 m lognormal, GSD² 1.12 — 0.1 ·
Transport, freight, lorry, 16t-32t gross weight, fleet average technosphere CH 9.43 tkm lognormal, GSD² 2.02 — 0.0 ·
Disposal, air filter, in exhaust air valve technosphere CH 18 p lognormal, GSD² 1.12 — 0.0 ·
Disposal, silencer, steel, DN 125 technosphere CH 24 p lognormal, GSD² 1.12 — 0.0 ·
Disposal, building, bulk iron (excluding reinforcement), to sorting plant technosphere CH 119 kg lognormal, GSD² 1.12 — 0.0 ·

Data quality

0 of 29 direct exchanges carry a declared pedigree, 29 carry a distribution.

Field As declared by the publisher
Data generator / entry / validation data generator: Alex Primas (HSLU); data entry: Alex Primas (HSLU); validation (proof reading): Rolf Frischknecht (TREEZE)
extrapolations none
sampling procedure Questionnaire and assumptions. Data valid for example building used.
production volume na
uncertainty adjustments none
validation details Proof reading validation: passed; Other validation: none;
time period comment Amount of material investigated in 2003

Data gaps, proxies and assumptions

None recorded.

Life cycle impact assessment (EF v3.1)

Per 1 p. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.

Impact category Indicator Unit Result 2.5 % 97.5 % GSD²
Acidification Accumulated Exceedance (AE) mol H+ eq 52.45 34.21 100.5 1.73
Climate change-Biogenic Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 8.461 5.806 19.74 1.88
Climate change-Fossil Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 4319 4207 5171 1.11
Climate change-Land use and land use change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 1.661 1.39 2.655 1.39
Climate change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 4329 4217 5183 1.11
EF-particulate Matter Impact on human health disease incidence 5.510e-04 4.108e-04 9.489e-04 1.51
Ecotoxicity, freshwater_inorganics Comparative Toxic Unit for ecosystems (CTUe) CTUe 1.867e+04 1.792e+04 3.327e+04 1.38
Ecotoxicity, freshwater_organics Comparative Toxic Unit for ecosystems (CTUe) CTUe 404.1 395.4 704.8 1.42
Ecotoxicity, freshwater Comparative Toxic Unit for ecosystems (CTUe) CTUe 1.908e+04 1.84e+04 3.384e+04 1.37
Eutrophication marine Fraction of nutrients reaching marine end compartment (N) kg N eq 3.936 3.459 5.863 1.31
Eutrophication, freshwater Fraction of nutrients reaching freshwater end compartment (P) kg P eq 2.19 1.635 11.94 2.78
Eutrophication, terrestrial Accumulated Exceedance (AE) mol N eq 202 118.5 408.7 1.88
Human toxicity, cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 1.864e-06 1.875e-06 4.912e-06 1.62
Human toxicity, cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 1.597e-06 1.397e-06 3.033e-06 1.49
Human toxicity, cancer Comparative Toxic Unit for human (CTUh) CTUh 3.461e-06 3.527e-06 7.239e-06 1.43
Human toxicity, non-cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 1.573e-04 1.367e-04 4.332e-04 1.77
Human toxicity, non-cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 6.531e-06 4.773e-06 1.257e-05 1.66
Human toxicity, non-cancer Comparative Toxic Unit for human (CTUh) CTUh 1.638e-04 1.449e-04 4.453e-04 1.75
Ionising radiation, human health Human exposure efficiency relative to U235 kBq U235 eq 974.2 375.7 5812 4.14
Land use Soil quality index pt (soil quality index) 1.981e+04 1.847e+04 3.421e+04 1.37
Ozone depletion Ozone Depletion Potential (ODP) kg CFC-11 eq 1.447e-04 1.321e-04 2.087e-04 1.27
Photochemical ozone formation - human health Tropospheric ozone concentration increase kg NMVOC eq 11.73 11.27 17.44 1.25
Resource use, fossils Abiotic resource depletion fossil fuels (ADP-fossil) MJ 5.59e+04 5.093e+04 7.948e+04 1.25
Resource use, minerals and metals Abiotic resource depletion (ADP ultimate reserve) kg Sb eq 0.1266 -0.0955 0.5406 —
Water use User deprivation potential (deprivation-weighted water consumption) m3 world eq deprived 384.2 -5.954e+05 2.899e+05 —

Climate change 4329 kg CO2 eq per p. Main contributors: Ventilation equipment, decentralized, 180-250 m3/h, at plant 29 %; Silencer, steel, DN 125, at plant 16 %; Air distribution housing, steel, 120 m3/h, at plant 10 %; Ventilation duct, PE corrugated tube, DN 75, at plant 10 %; Disposal, building, polyethylene/polypropylene products, to … 9 %; Supply air inlet, steel, SS, DN 75, at plant 7 %.

Interpretation

Significant issues

Direct exchanges dominating climate change: Ventilation equipment, decentralized, 180-250 m3/h, at plant 29 %; Silencer, steel, DN 125, at plant 16 %; Air distribution housing, steel, 120 m3/h, at plant 10 %; Ventilation duct, PE corrugated tube, DN 75, at plant 10 %; Disposal, building, polyethylene/polypropylene products, to … 9 %; Supply air inlet, steel, SS, DN 75, at plant 7 %. Most sensitive exchanges (Section 6.3): Ventilation equipment, decentralized, 180-250 m3/h, at plant [RER] (-3.1 / +3.4 %); Silencer, steel, DN 125, at plant [CH] (-1.7 / +1.9 %); Air distribution housing, steel, 120 m3/h, at plant [CH] (-1.0 / +1.2 %).

Independent recalculation

Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026):

Category Graph Published Graph / published
Acidification 52.45 54.07 0.970
Climate change-Biogenic 8.461 8.461 1.000
Climate change-Fossil 4319 4319 1.000
Climate change-Land use and land use change 1.661 1.661 1.000
Climate change 4329 4329 1.000
EF-particulate Matter 5.510e-04 5.510e-04 1.000
Ecotoxicity, freshwater_inorganics 1.867e+04 1.877e+04 0.995
Ecotoxicity, freshwater_organics 404.1 394.7 1.024
Ecotoxicity, freshwater 1.908e+04 1.914e+04 0.997
Eutrophication marine 3.936 3.935 1.000
Eutrophication, freshwater 2.19 2.19 1.000
Eutrophication, terrestrial 202 203.1 0.995
Human toxicity, cancer_inorganics 1.864e-06 1.853e-06 1.006
Human toxicity, cancer_organics 1.597e-06 1.597e-06 1.000
Human toxicity, cancer 3.461e-06 3.450e-06 1.003
Human toxicity, non-cancer_inorganics 1.573e-04 1.568e-04 1.003
Human toxicity, non-cancer_organics 6.531e-06 6.530e-06 1.000
Human toxicity, non-cancer 1.638e-04 1.634e-04 1.003
Ionising radiation, human health 974.2 974.2 1.000
Land use 1.981e+04 1.509e+04 1.313
Ozone depletion 1.447e-04 1.447e-04 1.000
Photochemical ozone formation - human health 11.73 11.73 1.000
Resource use, fossils 5.59e+04 5.591e+04 1.000
Resource use, minerals and metals 0.1266 0.1238 1.022
Water use 384.2 393 0.977
Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like.
Also published by BAFU for this dataset: IPCC 2021 GWP100 4329 kg CO2 eq; Ecological Scarcity
2021 total 9.940e+06 UBP.

Sensitivity check

One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.

Exchange Base Low / high Range Δ GWP100 (%) Δ other categories (max %)
Ventilation equipment, decentralized, 180-250 m3/h, at plant [RER] 6 p ×0.895 / ×1.12 lognormal, GSD² 1.12 -3.1 / +3.4 4.6 (Climate change-Land use and land use change)
Silencer, steel, DN 125, at plant [CH] 24 p ×0.895 / ×1.12 lognormal, GSD² 1.12 -1.7 / +1.9 4.3 (Human toxicity, cancer_organics)
Air distribution housing, steel, 120 m3/h, at plant [CH] 12 p ×0.895 / ×1.12 lognormal, GSD² 1.12 -1.0 / +1.2 2.0 (Eutrophication, terrestrial)
Ventilation duct, PE corrugated tube, DN 75, at plant [RER] 400 m ×0.895 / ×1.12 lognormal, GSD² 1.12 -1.0 / +1.1 2.4 (Resource use, fossils)
Disposal, building, polyethylene/polypropylene products, to final disposal [CH] 132 kg ×0.895 / ×1.12 lognormal, GSD² 1.12 -1.0 / +1.1 1.1 (Climate change-Fossil)
Transport, freight, lorry, 3.5t gross weight, fleet average [CH] 44.1 tkm ×0.493 / ×2.03 lognormal, GSD² 2.06 -0.6 / +1.1 5.2 (Ozone depletion)
Supply air inlet, steel, SS, DN 75, at plant [RER] 30 p ×0.895 / ×1.12 lognormal, GSD² 1.12 -0.7 / +0.8 1.4 (Eutrophication, terrestrial)
Disposal, ventilation equipment, decentralized, 180-250 m3 [CH] 6 p ×0.895 / ×1.12 lognormal, GSD² 1.12 -0.4 / +0.5 0.5 (Climate change-Fossil)
Exhaust air outlet, steel/aluminum, 85×365 mm, at plant [CH] 12 p ×0.895 / ×1.12 lognormal, GSD² 1.12 -0.3 / +0.4 0.6 (Climate change-Land use and land use change)
Transport, freight, lorry, fleet average [RER] 92.1 tkm ×0.502 / ×1.99 lognormal, GSD² 2.02 -0.2 / +0.4 4.0 (Climate change-Land use and land use change)
Spiral-seam duct, steel, DN 125, at plant [RER] 12 m ×0.895 / ×1.12 lognormal, GSD² 1.12 -0.3 / +0.3 0.9 (Eutrophication, terrestrial)
Control and wiring, decentralized unit, at plant [RER] 6 p ×0.895 / ×1.12 lognormal, GSD² 1.12 -0.2 / +0.3 4.0 (Resource use, minerals and metals)
Overflow element, steel, approx. 40 m3/h [RER] 18 p ×0.895 / ×1.12 lognormal, GSD² 1.12 -0.2 / +0.2 0.4 (Ozone depletion)
Sealing tape, aluminum/PE, 50 mm wide, at plant [RER] 200 m ×0.895 / ×1.12 lognormal, GSD² 1.12 -0.1 / +0.1 0.3 (Ecotoxicity, freshwater_organics)
Exhaust air valve, in-wall housing, plastic/steel, DN 125, at plant [CH] 18 p ×0.895 / ×1.12 lognormal, GSD² 1.12 -0.1 / +0.1 0.3 (Ozone depletion)

Uncertainty analysis

Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.

Comparison with other data

No other location of this dataset in the graph.

Conclusions and limitations

GWP100 4329 kg CO2 eq per p (95 % interval 4217–5183). Dominant contributors: Ventilation equipment, decentralized, 180-250 m3/h, at plant 29 %; Silencer, steel, DN 125, at plant 16 %; Air distribution housing, steel, 120 m3/h, at plant 10 %; Ventilation duct, PE corrugated tube, DN 75, at plant 10 %; Disposal, building, polyethylene/polypropylene products, to … 9 %; Supply air inlet, steel, SS, DN 75, at plant 7 %. Most sensitive: Ventilation equipment, decentralized, 180-250 m3/h, at plant [RER] (-3.1 / +3.4 %); Silencer, steel, DN 125, at plant [CH] (-1.7 / +1.9 %); Air distribution housing, steel, 120 m3/h, at plant [CH] (-1.0 / +1.2 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.

Final control

Item Status Detail
reference flow PASS production amount 1.0 p
closure: sum of direct contributions = dataset score (all 25 categories) PASS largest relative gap 5.9e-16
independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) PASS graph / published = 1; categories within ±5 %: 24/25
every technosphere input of the EcoSpold delivery is in the graph PASS all present (bafu_links_check.py)
uncertainty declared on the direct exchanges PASS 29/29 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values
Monte Carlo 95 % interval contains the deterministic score PASS 4329 in [4217, 5183]
time period declared PASS 2003-01/2003-12
geography is a known location code PASS CH
sources cited PASS 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them

References

  1. Hässig, W., Primas, A. (2007) Ökologische Aspekte der Komfortlüftungen im Wohnbereich. Final report ecoinvent Data v2.0. Volume: 25. Swiss Centre for LCI, B+H. Dübendorf and Zürich, CH. Type: Measurement on site Source: CD-ROM First author: Hässig, W. Other authors: Primas, A. Year: 2007 Title of anthology: Final report ecoinvent Data v2.0 Place of publication: Dübendorf and Zürich, CH Publisher: … — published source; as declared by BAFU (not found in OpenAlex/Crossref)
  2. Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — database; dataset citation
  3. International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva.
  4. Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. (tdc-doc method reference; title, version and year to verify against the user's copy)
  5. European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra.
  6. Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236

Annex — licence and terms of use