Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Battery cell, Li-ion, NMC111 [GLO], per 1 kg. EF v3.1 climate change 12.71 kg CO2 eq (Monte Carlo 95 % interval 11.24–18.24). Main contributors: Cathode, lithium-ion battery, NMC111 66 %; District heat, at consumer, natural gas in industrial furnac… 9 %; Electricity, medium voltage, production RAS, at grid 7 %; Anode, graphite, for Li-ion battery 5 %; Electrolyte, LiPF6, at plant 4 %; Copper collector foil production, for Li-ion battery 4 %. Status: final control passed.
Item Value
Dataset name Battery cell, Li-ion, NMC111
Dataset UUID / graph id aadedb31-43c4-379a-a0fd-fca88161a17c / activity:battery_cell_li_ion_nmc111__glo
Reference product, unit Battery cell, Li-ion, NMC111, 1 kg
Location GLO — Data for global average battery cells.
Time period 2023-01/2029-12
Category electronics / batteries
Source database BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1
Publisher Swiss Federal Office for the Environment (FOEN/BAFU)
Background database BAFU 2026 v1 (graph bafuquery-db)
LCIA method EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix)
Status final control passed
Documented by tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17

Introduction

The activity starts with the battery cells, module packaging and the materials for additional components (esternal case, tabs, etc.) entering the factory gate. The activity ends with the production of Li-ion battery pack.; UUID: aadedb31-43c4-379a-a0fd-fca88161a17c

This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.

Goal and scope

Function, functional unit and reference flow

Reference flow: 1 kg of Battery cell, Li-ion, NMC111 (GLO). All results are given per unit of the reference flow.

System boundary

This dataset represents the production of 1 kg of Li-ion battery pack used e.g. for mechanical drive of an electric vehicle or portable consumer electronics. The inventory is modelled according to the publication of Dai et al. (2019), in which a battery pack with gross pack energy of 23.5 kWh made of 140 3.6 V- 46Ah prismatic cells is presented. Cells are made of nickel-manganese-cobalt (NMC111) cathode and a graphite-based anode, liquid electrolyte and a porous plastic separator. Infrastructure is included as well in this dataset as “electronic component factory”. This dataset is a copy of the corresponding regional dataset. Production volume was adjusted.;None;

Technology

Battery cells, lithium ion battery, NMC 111

Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).

LCIA method

EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.

Life cycle inventory

Inventory table

Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).

Exchange Type Location / compartment Amount Unit Uncertainty Pedigree GWP share (%) Notes
Cathode, lithium-ion battery, NMC111 technosphere GLO 0.41 kg lognormal, GSD² 1.26 — 65.9 █████████████
District heat, at consumer, natural gas in industrial furnace 1MW technosphere CH 12.51 MJ lognormal, GSD² 1.23 — 8.8 ██
Electricity, medium voltage, production RAS, at grid technosphere RAS 1.1875 kWh lognormal, GSD² 1.23 — 6.8 █
Anode, graphite, for Li-ion battery technosphere GLO 0.2 kg lognormal, GSD² 1.26 — 4.6 █
Electrolyte, LiPF6, at plant technosphere RAS 0.146 kg lognormal, GSD² 1.26 — 4.5 █
Copper collector foil production, for Li-ion battery technosphere GLO 0.12 kg lognormal, GSD² 1.23 — 4.2 █
Aluminium collector foil production, for Li-ion battery technosphere GLO 0.03 kg lognormal, GSD² 1.23 — 1.6 ·
Aluminium, production mix, wrought alloy, at plant technosphere RER 0.0283 kg lognormal, GSD² 1.23 — 1.1 ·
Copper, primary, at refinery technosphere GLO 0.0335 kg lognormal, GSD² 1.23 — 0.7 ·
Separator, lithium-ion battery, at plant technosphere RAS 0.02 kg lognormal, GSD² 1.26 — 0.5 ·
Transport, freight, lorry, fleet average technosphere RER 0.31 tkm lognormal, GSD² 2.06 — 0.5 ·
Chemical plant, organics technosphere RER 4.0000e-10 p lognormal, GSD² 3.06 — 0.3 ·
Sheet rolling, aluminium technosphere RER 0.0283 kg lognormal, GSD² 1.23 — 0.1 ·
Transport, freight, lorry, 3.5t gross weight, fleet average technosphere RER 0.0096 tkm lognormal, GSD² 2.06 — 0.1 ·
Transport, transoceanic container ship technosphere OCE 0.7368 tkm lognormal, GSD² 2.06 — 0.1 ·
Sheet rolling, copper technosphere RER 0.0335 kg lognormal, GSD² 1.23 — 0.1 ·
Polyethylene terephthalate, granulate, amorphous, at plant technosphere RER 0.00283 kg lognormal, GSD² 1.23 — 0.1 ·
Polypropylene, granulate, at plant technosphere RER 0.0013 kg lognormal, GSD² 1.23 — 0.0 ·
Extrusion, plastic film technosphere RER 0.0041 kg lognormal, GSD² 1.23 — 0.0 ·
Transport, freight, rail technosphere RER 0.0153 tkm lognormal, GSD² 2.06 — 0.0 ·
Waste Heat elementary air/Ground level / Urban (>1000 people/s… 100 MJ lognormal, GSD² 1.26 — 0.0 ·

Data quality

0 of 21 direct exchanges carry a declared pedigree, 21 carry a distribution.

Field As declared by the publisher
Data generator / entry / validation data generator: Lugas Raka Adrianto, Maulana Permana Ajie, Didier Beloin-Saint-Pierre (EMPA); data entry: Lugas Raka Adrianto, Maulana Permana Ajie, Didier Beloin-Saint-Pierre (EMPA); validation (proof reading): Mischa Zschokke (CARBOTECH)
sampling procedure Literature & own estimations
production volume unknown
uncertainty adjustments none
validation details Proof reading validation: Passed, Other validation: none, Validator: Mischa Zschokke, Company: Carbotech, Country: CH

Data gaps, proxies and assumptions

None recorded.

Life cycle impact assessment (EF v3.1)

Per 1 kg. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.

Impact category Indicator Unit Result 2.5 % 97.5 % GSD²
Acidification Accumulated Exceedance (AE) mol H+ eq 0.5175 0.3247 0.8533 1.65
Climate change-Biogenic Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.04093 0.02454 0.1119 2.14
Climate change-Fossil Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 12.66 11.19 18.18 1.28
Climate change-Land use and land use change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.005786 0.004762 0.009316 1.42
Climate change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 12.71 11.24 18.24 1.28
EF-particulate Matter Impact on human health disease incidence 9.667e-07 7.556e-07 1.614e-06 1.45
Ecotoxicity, freshwater_inorganics Comparative Toxic Unit for ecosystems (CTUe) CTUe 101.3 86.14 207.3 1.58
Ecotoxicity, freshwater_organics Comparative Toxic Unit for ecosystems (CTUe) CTUe 4.924 3.119 9.719 1.76
Ecotoxicity, freshwater Comparative Toxic Unit for ecosystems (CTUe) CTUe 106.2 91.16 213.8 1.56
Eutrophication marine Fraction of nutrients reaching marine end compartment (N) kg N eq 0.02208 0.01752 0.03805 1.5
Eutrophication, freshwater Fraction of nutrients reaching freshwater end compartment (P) kg P eq 0.03843 0.02294 0.2492 3.35
Eutrophication, terrestrial Accumulated Exceedance (AE) mol N eq 0.2859 0.2118 0.467 1.51
Human toxicity, cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 1.782e-08 1.278e-08 5.614e-08 2.19
Human toxicity, cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 1.038e-08 7.096e-09 1.779e-08 1.57
Human toxicity, cancer Comparative Toxic Unit for human (CTUh) CTUh 2.820e-08 2.267e-08 6.901e-08 1.77
Human toxicity, non-cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 1.536e-06 8.751e-07 5.550e-06 2.55
Human toxicity, non-cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 2.261e-07 1.485e-07 4.150e-07 1.68
Human toxicity, non-cancer Comparative Toxic Unit for human (CTUh) CTUh 1.762e-06 1.078e-06 5.770e-06 2.33
Ionising radiation, human health Human exposure efficiency relative to U235 kBq U235 eq 3.047 1.084 19.73 4.48
Land use Soil quality index pt (soil quality index) 96.1 83.56 163.8 1.4
Ozone depletion Ozone Depletion Potential (ODP) kg CFC-11 eq 3.670e-07 3.076e-07 6.249e-07 1.42
Photochemical ozone formation - human health Tropospheric ozone concentration increase kg NMVOC eq 0.0929 0.0728 0.1524 1.44
Resource use, fossils Abiotic resource depletion fossil fuels (ADP-fossil) MJ 187.8 160.5 298.3 1.37
Resource use, minerals and metals Abiotic resource depletion (ADP ultimate reserve) kg Sb eq 3.835e-04 2.817e-04 5.999e-04 1.45
Water use User deprivation potential (deprivation-weighted water consumption) m3 world eq deprived 1.404 -9984 5155 —

Climate change 12.71 kg CO2 eq per kg. Main contributors: Cathode, lithium-ion battery, NMC111 66 %; District heat, at consumer, natural gas in industrial furnac… 9 %; Electricity, medium voltage, production RAS, at grid 7 %; Anode, graphite, for Li-ion battery 5 %; Electrolyte, LiPF6, at plant 4 %; Copper collector foil production, for Li-ion battery 4 %.

Interpretation

Significant issues

Direct exchanges dominating climate change: Cathode, lithium-ion battery, NMC111 66 %; District heat, at consumer, natural gas in industrial furnac… 9 %; Electricity, medium voltage, production RAS, at grid 7 %; Anode, graphite, for Li-ion battery 5 %; Electrolyte, LiPF6, at plant 4 %; Copper collector foil production, for Li-ion battery 4 %. Most sensitive exchanges (Section 6.3): Cathode, lithium-ion battery, NMC111 [GLO] (-13.4 / +16.8 %); District heat, at consumer, natural gas in industrial furnace 1MW [CH] (-1.6 / +2.0 %); Electricity, medium voltage, production RAS, at grid [RAS] (-1.2 / +1.5 %).

Independent recalculation

Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026):

Category Graph Published Graph / published
Acidification 0.5175 0.5238 0.988
Climate change-Biogenic 0.04093 0.04093 1.000
Climate change-Fossil 12.66 12.66 1.000
Climate change-Land use and land use change 0.005786 0.005786 1.000
Climate change 12.71 12.71 1.000
EF-particulate Matter 9.667e-07 9.667e-07 1.000
Ecotoxicity, freshwater_inorganics 101.3 103.1 0.983
Ecotoxicity, freshwater_organics 4.924 4.91 1.003
Ecotoxicity, freshwater 106.2 108 0.984
Eutrophication marine 0.02208 0.02208 1.000
Eutrophication, freshwater 0.03843 0.03843 1.000
Eutrophication, terrestrial 0.2859 0.2933 0.975
Human toxicity, cancer_inorganics 1.782e-08 1.775e-08 1.004
Human toxicity, cancer_organics 1.038e-08 1.038e-08 1.000
Human toxicity, cancer 2.820e-08 2.813e-08 1.003
Human toxicity, non-cancer_inorganics 1.536e-06 1.532e-06 1.002
Human toxicity, non-cancer_organics 2.261e-07 2.261e-07 1.000
Human toxicity, non-cancer 1.762e-06 1.759e-06 1.002
Ionising radiation, human health 3.047 3.047 1.000
Land use 96.1 80.52 1.194
Ozone depletion 3.670e-07 3.670e-07 1.000
Photochemical ozone formation - human health 0.0929 0.0929 1.000
Resource use, fossils 187.8 187.8 1.000
Resource use, minerals and metals 3.835e-04 3.719e-04 1.031
Water use 1.404 1.539 0.912
Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like.
Also published by BAFU for this dataset: IPCC 2021 GWP100 12.71 kg CO2 eq; Ecological Scarcity
2021 total 4.231e+04 UBP.

Sensitivity check

One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.

Exchange Base Low / high Range Δ GWP100 (%) Δ other categories (max %)
Cathode, lithium-ion battery, NMC111 [GLO] 0.41 kg ×0.797 / ×1.25 lognormal, GSD² 1.26 -13.4 / +16.8 23.0 (Ecotoxicity, freshwater_organics)
District heat, at consumer, natural gas in industrial furnace 1MW [CH] 12.51 MJ ×0.816 / ×1.22 lognormal, GSD² 1.23 -1.6 / +2.0 2.2 (Resource use, fossils)
Electricity, medium voltage, production RAS, at grid [RAS] 1.188 kWh ×0.816 / ×1.22 lognormal, GSD² 1.23 -1.2 / +1.5 1.8 (Water use)
Anode, graphite, for Li-ion battery [GLO] 0.2 kg ×0.797 / ×1.25 lognormal, GSD² 1.26 -0.9 / +1.2 18.5 (Human toxicity, cancer_organics)
Electrolyte, LiPF6, at plant [RAS] 0.146 kg ×0.797 / ×1.25 lognormal, GSD² 1.26 -0.9 / +1.1 4.4 (Ozone depletion)
Copper collector foil production, for Li-ion battery [GLO] 0.12 kg ×0.816 / ×1.22 lognormal, GSD² 1.23 -0.8 / +0.9 15.9 (Human toxicity, non-cancer_inorganics)
Chemical plant, organics [RER] 4.000e-10 p ×0.334 / ×2.99 lognormal, GSD² 3.06 -0.2 / +0.6 2.1 (Land use)
Transport, freight, lorry, fleet average [RER] 0.31 tkm ×0.493 / ×2.03 lognormal, GSD² 2.06 -0.2 / +0.5 4.0 (Climate change-Land use and land use change)
Aluminium collector foil production, for Li-ion battery [GLO] 0.03 kg ×0.816 / ×1.22 lognormal, GSD² 1.23 -0.3 / +0.4 0.9 (Climate change-Land use and land use change)
Aluminium, production mix, wrought alloy, at plant [RER] 0.0283 kg ×0.816 / ×1.22 lognormal, GSD² 1.23 -0.2 / +0.2 0.8 (Climate change-Land use and land use change)
Copper, primary, at refinery [GLO] 0.0335 kg ×0.816 / ×1.22 lognormal, GSD² 1.23 -0.1 / +0.2 4.4 (Human toxicity, non-cancer_inorganics)
Separator, lithium-ion battery, at plant [RAS] 0.02 kg ×0.797 / ×1.25 lognormal, GSD² 1.26 -0.1 / +0.1 0.8 (Ozone depletion)
Transport, freight, lorry, 3.5t gross weight, fleet average [RER] 0.0096 tkm ×0.493 / ×2.03 lognormal, GSD² 2.06 -0.0 / +0.1 0.9 (Climate change-Land use and land use change)
Transport, transoceanic container ship [OCE] 0.7368 tkm ×0.493 / ×2.03 lognormal, GSD² 2.06 -0.0 / +0.1 0.5 (Eutrophication marine)
Sheet rolling, aluminium [RER] 0.0283 kg ×0.816 / ×1.22 lognormal, GSD² 1.23 -0.0 / +0.0 0.1 (Ionising radiation, human health)

Uncertainty analysis

Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.

Comparison with other data

No other location of this dataset in the graph.

Conclusions and limitations

GWP100 12.71 kg CO2 eq per kg (95 % interval 11.24–18.24). Dominant contributors: Cathode, lithium-ion battery, NMC111 66 %; District heat, at consumer, natural gas in industrial furnac… 9 %; Electricity, medium voltage, production RAS, at grid 7 %; Anode, graphite, for Li-ion battery 5 %; Electrolyte, LiPF6, at plant 4 %; Copper collector foil production, for Li-ion battery 4 %. Most sensitive: Cathode, lithium-ion battery, NMC111 [GLO] (-13.4 / +16.8 %); District heat, at consumer, natural gas in industrial furnace 1MW [CH] (-1.6 / +2.0 %); Electricity, medium voltage, production RAS, at grid [RAS] (-1.2 / +1.5 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.

Final control

Item Status Detail
reference flow PASS production amount 1.0 kg
closure: sum of direct contributions = dataset score (all 25 categories) PASS largest relative gap 4.2e-16
independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) PASS graph / published = 1; categories within ±5 %: 23/25
every technosphere input of the EcoSpold delivery is in the graph PASS all present (bafu_links_check.py)
uncertainty declared on the direct exchanges PASS 21/21 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values
Monte Carlo 95 % interval contains the deterministic score PASS 12.71 in [11.24, 18.24]
time period declared PASS 2023-01/2029-12
geography is a known location code PASS GLO
sources cited PASS 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them

References

  1. Raka Adrianto L. (2024) 2024 - LCI ICT sector - Raka Adrianto. Empa — source; as declared by BAFU (not found in OpenAlex/Crossref)
  2. Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — database; dataset citation
  3. International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva.
  4. Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. (tdc-doc method reference; title, version and year to verify against the user's copy)
  5. European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra.
  6. Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236

Annex — licence and terms of use

BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.


To suggest a correction or a dataset that does not exist yet, use Propose a dataset.

datasets/bafu/aadedb31-43c4-379a-a0fd-fca88161a17c.txt · Last modified: by 127.0.0.1

Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki