OpenData Wiki

Dataset documentation and review before publication

User Tools

Site Tools


datasets:bafu:ac149637-98f4-3f52-8b98-a9e168c40c40

xx Inverter, 500W, at plant — RER

Dataset documentation and final control (tdc-doc, imported mode)
Open this dataset in OpenData

Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset xx Inverter, 500W, at plant [RER], per 1 p. EF v3.1 climate change 30.86 kg CO2 eq (Monte Carlo 95 % interval 29.47–39.53). Main contributors: Printed wiring board, through-hole, at plant 15 %; Integrated circuit, IC, logic type, at plant 12 %; Capacitor, film, through-hole mounting, at plant 10 %; Aluminium, production mix, cast alloy, at plant 9 %; Inductor, ring core choke type, at plant 9 %; Capacitor, electrolyte type, > 2cm height, at plant 7 %. Status: final control passed.
Item Value
Dataset name xx Inverter, 500W, at plant
Dataset UUID / graph id ac149637-98f4-3f52-8b98-a9e168c40c40 / activity:xx_inverter_500w_at_plant__rer
Reference product, unit xx Inverter, 500W, at plant, 1 p
Location RER — Production in RER.
Time period 1992-01/2006-12
Category material, obsolete / electronics, obsolete\photovoltaic, obsolete\infrastructure, obsolete
Source database BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1
Publisher Swiss Federal Office for the Environment (FOEN/BAFU)
Background database BAFU 2026 v1 (graph bafuquery-db)
LCIA method EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix)
Status final control passed
Documented by tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17

Introduction

Production of an inverter (500W) with an efficiency of 93.5% (total efficiency factor which includes MPP-Tracking) for photovoltaic plant. Total weight about 1.6 kg.; Synonyms: inverse rectifier; UUID: ac149637-98f4-3f52-8b98-a9e168c40c40

This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.

Goal and scope

Function, functional unit and reference flow

Reference flow: 1 p of xx Inverter, 500W, at plant (RER). All results are given per unit of the reference flow.

System boundary

Materials, packaging and electricity use for the production of an inverse rectifier. Disposal of the product after use.

Technology

Inverter for a photovoltaic grid-connected system with a capacity of 500Wp.

Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).

LCIA method

EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.

Life cycle inventory

Inventory table

Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).

Exchange Type Location / compartment Amount Unit Uncertainty Pedigree GWP share (%) Notes
Printed wiring board, through-hole, at plant technosphere GLO 0.0596 m2 lognormal, GSD² 1.22 (2,3,1,1,1,5) 14.6 ███
Integrated circuit, IC, logic type, at plant technosphere GLO 0.006 kg lognormal, GSD² 1.22 (2,3,1,1,1,5) 11.7 ██
Capacitor, film, through-hole mounting, at plant technosphere GLO 0.072 kg lognormal, GSD² 1.22 (2,3,1,1,1,5) 10.0 ██
Aluminium, production mix, cast alloy, at plant technosphere RER 0.682 kg lognormal, GSD² 1.22 (2,3,1,1,1,5) 9.4 ██
Inductor, ring core choke type, at plant technosphere GLO 0.074 kg lognormal, GSD² 1.22 (2,3,1,1,1,5) 9.2 ██
Capacitor, electrolyte type, > 2cm height, at plant technosphere GLO 0.054 kg lognormal, GSD² 1.22 (2,3,1,1,1,5) 7.0 █
Diode, glass-, through-hole mounting, at plant technosphere GLO 0.01 kg lognormal, GSD² 1.22 (2,3,1,1,1,5) 6.1 █
Transformer, high voltage use, at plant technosphere GLO 0.31 kg lognormal, GSD² 1.22 (2,3,1,1,1,5) 5.2 █
Electricity, medium voltage, production ENTSO-E, at grid technosphere ENTSO-E 4.24 kWh lognormal, GSD² 1.31 (2,3,4,1,1,5) 3.8 █
Corrugated board, mixed fibre, single wall, at plant technosphere RER 1.12 kg lognormal, GSD² 1.24 (2,4,1,1,1,5) 3.3 █
Transistor, wired, small size, through-hole mounting, at plant technosphere GLO 0.008 kg lognormal, GSD² 1.22 (2,3,1,1,1,5) 2.8 █
Capacitor, Tantalum-, through-hole mounting, at plant technosphere GLO 0.0048 kg lognormal, GSD² 1.22 (2,3,1,1,1,5) 2.5 █
Disposal, plastic, industr. electronics, 15.3% water, to municipal incineration technosphere CH 0.23 kg lognormal, GSD² 1.25 (2,3,1,5,1,5) 2.3 ·
Acrylonitrile-butadiene-styrene copolymer, ABS, at plant technosphere RER 0.148 kg lognormal, GSD² 1.22 (2,3,1,1,1,5) 2.2 ·
Polycarbonate, at plant technosphere RER 0.068 kg lognormal, GSD² 1.22 (2,3,1,1,1,5) 1.8 ·
Section bar extrusion, aluminium technosphere RER 0.682 kg lognormal, GSD² 1.22 (2,3,1,1,1,5) 1.6 ·
Polystyrene foam slab, at plant technosphere RER 0.13 kg lognormal, GSD² 1.31 (2,3,4,1,1,5) 1.4 ·
Disposal, polystyrene, 0.2% water, to municipal incineration technosphere CH 0.132 kg lognormal, GSD² 1.25 (2,3,1,5,1,5) 1.4 ·
Connector, clamp connection, at plant technosphere GLO 0.05 kg lognormal, GSD² 1.22 (2,3,1,1,1,5) 1.1 ·
Steel, low-alloyed, at plant technosphere RER 0.078 kg lognormal, GSD² 1.22 (2,3,1,1,1,5) 0.5 ·
Metal working factory technosphere RER 1.0424e-09 p lognormal, GSD² 3.06 (2,4,1,1,1,5) 0.3 ·
Fleece, polyethylene, at plant technosphere RER 0.03 kg lognormal, GSD² 1.31 (2,3,4,1,1,5) 0.3 ·
Disposal, polyethylene, 0.4% water, to municipal incineration technosphere CH 0.03 kg lognormal, GSD² 1.25 (2,3,1,5,1,5) 0.3 ·
Disposal, treatment of printed wiring boards technosphere GLO 0.6898 kg lognormal, GSD² 1.25 (2,3,1,5,1,5) 0.2 ·
Transport, freight, lorry, fleet average technosphere RER 0.36556 tkm lognormal, GSD² 2.1 — 0.2 ·
Transport, transoceanic freight ship technosphere OCE 8.0897 tkm lognormal, GSD² 2.1 — 0.2 ·
Disposal, packaging cardboard, 19.6% water, to municipal incineration technosphere CH 1.12 kg lognormal, GSD² 1.25 (2,3,1,5,1,5) 0.1 ·
Polyethylene, HDPE, granulate, at plant technosphere RER 0.014 kg lognormal, GSD² 1.22 (2,3,1,1,1,5) 0.1 ·
Transport, freight, rail technosphere RER 1.8886 tkm lognormal, GSD² 2.1 — 0.1 ·
Sheet rolling, steel technosphere RER 0.078 kg lognormal, GSD² 1.22 (2,3,1,1,1,5) 0.1 ·
Resistor, metal film type, through-hole mounting, at plant technosphere GLO 0.001 kg lognormal, GSD² 1.22 (2,3,1,1,1,5) 0.1 ·
Styrene-acrylonitrile copolymer, SAN, at plant technosphere RER 0.002 kg lognormal, GSD² 1.22 (2,3,1,1,1,5) 0.0 ·
Polyvinylchloride, at regional storage technosphere RER 0.002 kg lognormal, GSD² 1.22 (2,3,1,1,1,5) 0.0 ·
Copper, at regional storage technosphere RER 0.002 kg lognormal, GSD² 1.22 (2,3,1,1,1,5) 0.0 ·
Wire drawing, copper technosphere RER 0.002 kg lognormal, GSD² 1.22 (2,3,1,1,1,5) 0.0 ·
Waste Heat elementary air/Ground level / Urban (>1000 people/s… 15.264 MJ lognormal, GSD² 1.22 (2,3,1,1,1,5) 0.0 ·

Data quality

33 of 36 direct exchanges carry a declared pedigree, 36 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 2.0 · completeness 3.06 · temporal 1.27 · geographical 1.61 · technological 1.0 · sample size 5.0.

Field As declared by the publisher
Data generator / entry / validation data generator: Matthias Tuchschmid; data entry: Matthias Tuchschmid; validation (proof reading): Christian Bauer (PSI)
extrapolations Packaging materials and energy consumption during production has been scaled down from 2500 W-Inverter.
sampling procedure Detailed analysis of materials for one product
production volume na
uncertainty adjustments none
validation details Proof reading validation: passed; Other validation: none;
time period comment undefined

Data gaps, proxies and assumptions

None recorded.

Life cycle impact assessment (EF v3.1)

Per 1 p. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.

Impact category Indicator Unit Result 2.5 % 97.5 % GSD²
Acidification Accumulated Exceedance (AE) mol H+ eq 0.162 0.1455 0.2254 1.25
Climate change-Biogenic Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.124 0.07689 0.3171 2.03
Climate change-Fossil Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 30.71 29.33 39.35 1.16
Climate change-Land use and land use change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.01902 0.0153 0.02958 1.41
Climate change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 30.86 29.47 39.53 1.16
EF-particulate Matter Impact on human health disease incidence 1.370e-06 1.359e-06 1.939e-06 1.2
Ecotoxicity, freshwater_inorganics Comparative Toxic Unit for ecosystems (CTUe) CTUe 268.3 262.1 433.2 1.3
Ecotoxicity, freshwater_organics Comparative Toxic Unit for ecosystems (CTUe) CTUe 12.09 10.37 19.11 1.37
Ecotoxicity, freshwater Comparative Toxic Unit for ecosystems (CTUe) CTUe 280.4 276 446.2 1.29
Eutrophication marine Fraction of nutrients reaching marine end compartment (N) kg N eq 0.03078 0.02946 0.04578 1.27
Eutrophication, freshwater Fraction of nutrients reaching freshwater end compartment (P) kg P eq 0.05343 0.03487 0.3363 3.13
Eutrophication, terrestrial Accumulated Exceedance (AE) mol N eq 0.2839 0.2642 0.4219 1.27
Human toxicity, cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 2.192e-08 2.080e-08 6.049e-08 1.73
Human toxicity, cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 9.208e-09 8.569e-09 1.446e-08 1.32
Human toxicity, cancer Comparative Toxic Unit for human (CTUh) CTUh 3.113e-08 3.094e-08 7.149e-08 1.55
Human toxicity, non-cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 1.630e-06 1.403e-06 4.585e-06 1.88
Human toxicity, non-cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 7.728e-08 5.444e-08 1.470e-07 1.65
Human toxicity, non-cancer Comparative Toxic Unit for human (CTUh) CTUh 1.707e-06 1.478e-06 4.670e-06 1.85
Ionising radiation, human health Human exposure efficiency relative to U235 kBq U235 eq 8.897 3.008 55.76 4.56
Land use Soil quality index pt (soil quality index) 271.9 248.1 436.2 1.34
Ozone depletion Ozone Depletion Potential (ODP) kg CFC-11 eq 1.136e-06 1.013e-06 1.710e-06 1.32
Photochemical ozone formation - human health Tropospheric ozone concentration increase kg NMVOC eq 0.1336 0.1261 0.1946 1.24
Resource use, fossils Abiotic resource depletion fossil fuels (ADP-fossil) MJ 446 426.3 635.2 1.23
Resource use, minerals and metals Abiotic resource depletion (ADP ultimate reserve) kg Sb eq 0.00821 0.006703 0.01062 1.27
Water use User deprivation potential (deprivation-weighted water consumption) m3 world eq deprived 4.364 -8350 4225 —

Climate change 30.86 kg CO2 eq per p. Main contributors: Printed wiring board, through-hole, at plant 15 %; Integrated circuit, IC, logic type, at plant 12 %; Capacitor, film, through-hole mounting, at plant 10 %; Aluminium, production mix, cast alloy, at plant 9 %; Inductor, ring core choke type, at plant 9 %; Capacitor, electrolyte type, > 2cm height, at plant 7 %.

Interpretation

Significant issues

Direct exchanges dominating climate change: Printed wiring board, through-hole, at plant 15 %; Integrated circuit, IC, logic type, at plant 12 %; Capacitor, film, through-hole mounting, at plant 10 %; Aluminium, production mix, cast alloy, at plant 9 %; Inductor, ring core choke type, at plant 9 %; Capacitor, electrolyte type, > 2cm height, at plant 7 %. Most sensitive exchanges (Section 6.3): Printed wiring board, through-hole, at plant [GLO] (-2.6 / +3.2 %); Integrated circuit, IC, logic type, at plant [GLO] (-2.1 / +2.5 %); Capacitor, film, through-hole mounting, at plant [GLO] (-1.8 / +2.2 %).

Independent recalculation

Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026):

Category Graph Published Graph / published
Acidification 0.162 0.1787 0.907
Climate change-Biogenic 0.124 0.124 1.000
Climate change-Fossil 30.71 30.71 1.000
Climate change-Land use and land use change 0.01902 0.01902 1.000
Climate change 30.86 30.86 1.000
EF-particulate Matter 1.370e-06 1.370e-06 1.000
Ecotoxicity, freshwater_inorganics 268.3 275.6 0.974
Ecotoxicity, freshwater_organics 12.09 11.09 1.091
Ecotoxicity, freshwater 280.4 285.1 0.984
Eutrophication marine 0.03078 0.03078 1.000
Eutrophication, freshwater 0.05343 0.05343 1.000
Eutrophication, terrestrial 0.2839 0.2996 0.948
Human toxicity, cancer_inorganics 2.192e-08 2.176e-08 1.007
Human toxicity, cancer_organics 9.208e-09 9.208e-09 1.000
Human toxicity, cancer 3.113e-08 3.097e-08 1.005
Human toxicity, non-cancer_inorganics 1.630e-06 1.621e-06 1.006
Human toxicity, non-cancer_organics 7.728e-08 7.723e-08 1.001
Human toxicity, non-cancer 1.707e-06 1.698e-06 1.005
Ionising radiation, human health 8.897 8.897 1.000
Land use 271.9 225.8 1.204
Ozone depletion 1.136e-06 1.136e-06 1.000
Photochemical ozone formation - human health 0.1336 0.1336 1.000
Resource use, fossils 446 446.1 1.000
Resource use, minerals and metals 0.00821 0.008156 1.007
Water use 4.364 4.583 0.952
Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like.
Also published by BAFU for this dataset: IPCC 2021 GWP100 30.85 kg CO2 eq; Ecological Scarcity
2021 total 8.578e+04 UBP.

Sensitivity check

One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.

Exchange Base Low / high Range Δ GWP100 (%) Δ other categories (max %)
Printed wiring board, through-hole, at plant [GLO] 0.0596 m2 ×0.821 / ×1.22 lognormal, GSD² 1.22 -2.6 / +3.2 7.1 (Human toxicity, non-cancer_organics)
Integrated circuit, IC, logic type, at plant [GLO] 0.006 kg ×0.821 / ×1.22 lognormal, GSD² 1.22 -2.1 / +2.5 10.2 (Resource use, minerals and metals)
Capacitor, film, through-hole mounting, at plant [GLO] 0.072 kg ×0.821 / ×1.22 lognormal, GSD² 1.22 -1.8 / +2.2 11.8 (Ecotoxicity, freshwater_organics)
Aluminium, production mix, cast alloy, at plant [RER] 0.682 kg ×0.821 / ×1.22 lognormal, GSD² 1.22 -1.7 / +2.1 4.4 (Climate change-Land use and land use change)
Inductor, ring core choke type, at plant [GLO] 0.074 kg ×0.821 / ×1.22 lognormal, GSD² 1.22 -1.6 / +2.0 3.2 (Photochemical ozone formation - human health)
Capacitor, electrolyte type, > 2cm height, at plant [GLO] 0.054 kg ×0.821 / ×1.22 lognormal, GSD² 1.22 -1.3 / +1.5 2.3 (Photochemical ozone formation - human health)
Diode, glass-, through-hole mounting, at plant [GLO] 0.01 kg ×0.821 / ×1.22 lognormal, GSD² 1.22 -1.1 / +1.3 1.7 (Climate change-Biogenic)
Transformer, high voltage use, at plant [GLO] 0.31 kg ×0.821 / ×1.22 lognormal, GSD² 1.22 -0.9 / +1.1 3.6 (EF-particulate Matter)
Electricity, medium voltage, production ENTSO-E, at grid [ENTSO-E] 4.24 kWh ×0.767 / ×1.3 lognormal, GSD² 1.31 -0.9 / +1.1 5.3 (Ionising radiation, human health)
Corrugated board, mixed fibre, single wall, at plant [RER] 1.12 kg ×0.808 / ×1.24 lognormal, GSD² 1.24 -0.6 / +0.8 5.0 (Land use)
Transistor, wired, small size, through-hole mounting, at plant [GLO] 0.008 kg ×0.821 / ×1.22 lognormal, GSD² 1.22 -0.5 / +0.6 0.9 (Climate change-Land use and land use change)
Disposal, plastic, industr. electronics, 15.3% water, to municipal incineration [CH] 0.23 kg ×0.804 / ×1.24 lognormal, GSD² 1.25 -0.4 / +0.6 0.6 (Ecotoxicity, freshwater_inorganics)
Capacitor, Tantalum-, through-hole mounting, at plant [GLO] 0.0048 kg ×0.821 / ×1.22 lognormal, GSD² 1.22 -0.4 / +0.5 2.0 (Ozone depletion)
Metal working factory [RER] 1.042e-09 p ×0.334 / ×2.99 lognormal, GSD² 3.06 -0.2 / +0.7 9.4 (Land use)
Acrylonitrile-butadiene-styrene copolymer, ABS, at plant [RER] 0.148 kg ×0.821 / ×1.22 lognormal, GSD² 1.22 -0.4 / +0.5 0.7 (Resource use, fossils)

Uncertainty analysis

Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.

Comparison with other data

No other location of this dataset in the graph.

Conclusions and limitations

GWP100 30.86 kg CO2 eq per p (95 % interval 29.47–39.53). Dominant contributors: Printed wiring board, through-hole, at plant 15 %; Integrated circuit, IC, logic type, at plant 12 %; Capacitor, film, through-hole mounting, at plant 10 %; Aluminium, production mix, cast alloy, at plant 9 %; Inductor, ring core choke type, at plant 9 %; Capacitor, electrolyte type, > 2cm height, at plant 7 %. Most sensitive: Printed wiring board, through-hole, at plant [GLO] (-2.6 / +3.2 %); Integrated circuit, IC, logic type, at plant [GLO] (-2.1 / +2.5 %); Capacitor, film, through-hole mounting, at plant [GLO] (-1.8 / +2.2 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.

Final control

Item Status Detail
reference flow PASS production amount 1.0 p
closure: sum of direct contributions = dataset score (all 25 categories) PASS largest relative gap 6.3e-16
independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) PASS graph / published = 1; categories within ±5 %: 21/25
every technosphere input of the EcoSpold delivery is in the graph PASS all present (bafu_links_check.py)
uncertainty declared on the direct exchanges PASS 36/36 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values
Monte Carlo 95 % interval contains the deterministic score PASS 30.86 in [29.47, 39.53]
time period declared PASS 1992-01/2006-12
geography is a known location code PASS RER
sources cited PASS 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them

References

  1. Jungbluth, N., Stucki, M., Frischknecht, R. (2009) Photovoltaics. Sachbilanzen von Energiesystemen. Final report No. 6 ecoinvent v2.1. Editors: Bauer C.. Volume: 6. Swiss Centre for LCI, PSI. Dübendorf and Villigen, CH. Type: Measurement on site Source: CD-ROM First author: Jungbluth, N. Other authors: Stucki, M., Frischknecht, R. Year: 2009 Name of editors: Bauer C. Title of anthology: Sachbilanz… — published source; as declared by BAFU (not found in OpenAlex/Crossref)
  2. Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — database; dataset citation
  3. International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva.
  4. Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. (tdc-doc method reference; title, version and year to verify against the user's copy)
  5. European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra.
  6. Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236

Annex — licence and terms of use

BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.


To suggest a correction or a dataset that does not exist yet, use Propose a dataset.

datasets/bafu/ac149637-98f4-3f52-8b98-a9e168c40c40.txt · Last modified: by 127.0.0.1

Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki