OpenData Wiki

Dataset documentation and review before publication

User Tools

Site Tools


datasets:bafu:aeb0fb1c-e3e4-371c-802e-7513e1b69faa

Electricity, at cogen with biogas engine, allocation exergy — CH

Dataset documentation and final control (tdc-doc, imported mode)
Open this dataset in OpenData

Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Electricity, at cogen with biogas engine, allocation exergy [CH], per 1 kWh. EF v3.1 climate change 0.1681 kg CO2 eq (Monte Carlo 95 % interval 0.1308–0.2389). Main contributors: Biogas, production mix, at storage 90 %; Nitrous Oxide 4 %; Methane (biogenic) 3 %; Cogen unit 160kWe, common components for heat+electricity 2 %. Status: final control passed.
Item Value
Dataset name Electricity, at cogen with biogas engine, allocation exergy
Dataset UUID / graph id aeb0fb1c-e3e4-371c-802e-7513e1b69faa / activity:electricity_at_cogen_with_biogas_engine_allocation_exergy__ch
Reference product, unit Electricity, at cogen with biogas engine, allocation exergy, 1 kWh
Location CH — Conditions of cogeneration in Switzerland.
Time period 2000-01/2004-12
Category electricity by fuel / biomass\cogeneration
Source database BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1
Publisher Swiss Federal Office for the Environment (FOEN/BAFU)
Background database BAFU 2026 v1 (graph bafuquery-db)
LCIA method EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix)
Status final control passed
Documented by tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17

Introduction

The multioutput process “biogas gas burned in cogen with gas engine” delivers the co-products: heat and electricity. The allocation is based on the exergy values of heat and electricity. The exergy value of electricity is 1, and the exergy value of heat is 0.17. The degrees of efficiency are as follows: electricity: 0.32 and heat: 0.55.; UUID: aeb0fb1c-e3e4-371c-802e-7513e1b69faa

This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.

Goal and scope

Function, functional unit and reference flow

Reference flow: 1 kWh of Electricity, at cogen with biogas engine, allocation exergy (CH). All results are given per unit of the reference flow.

System boundary

Use of biogas in a cogeneration unit. Included are emissions to air, biogas consumption, use and disposal of operational supplements as well as infrastructure expenditures.

Technology

Lambda 1-engine“ with a catalytic converter

Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).

LCIA method

EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.

Life cycle inventory

Inventory table

Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).

Exchange Type Location / compartment Amount Unit Uncertainty Pedigree GWP share (%) Notes
Biogas, production mix, at storage technosphere CH 0.38298 m3 lognormal, GSD² 1.26 (1,4,2,1,3,4) 90.3 ██████████████████
Cogen unit 160kWe, common components for heat+electricity technosphere RER 4.3531e-08 p lognormal, GSD² 3.07 (1,4,2,1,3,4) 1.9 ·
Disposal, used mineral oil, 10% water, to hazardous waste incineration technosphere CH 2.6118e-04 kg lognormal, GSD² 1.26 (1,4,2,1,3,4) 0.4 ·
Cogen unit 160kWe, components for electricity only technosphere RER 5.6250e-08 p lognormal, GSD² 3.07 (1,4,2,1,3,4) 0.4 ·
Lubricating oil, at plant technosphere RER 2.6118e-04 kg lognormal, GSD² 1.26 (1,4,2,1,3,4) 0.2 ·
Nitrous Oxide elementary air/Medium stack, <150 meters / Rural (<… 2.1765e-05 kg lognormal, GSD² 3.07 (1,4,2,1,3,4) 3.5 █
Methane (biogenic) elementary air/Medium stack, <150 meters / Rural (<… 2.0024e-04 kg lognormal, GSD² 3.07 (1,4,1,1,3,4) 3.2 █
Nitrogen Oxides, CH elementary air/Medium stack, <150 meters / Rural (<… 1.3059e-04 kg lognormal, GSD² 2.07 (1,4,2,1,3,4) 0.0 ·
Carbon Dioxide (biogenic) elementary air/Medium stack, <150 meters / Rural (<… 0.72698 kg lognormal, GSD² 1.26 (1,4,2,1,3,4) 0.0 ·
Platinum elementary air/Medium stack, <150 meters / Rural (<… 6.0943e-11 kg lognormal, GSD² 5.08 (1,4,2,1,3,4) 0.0 ·
Non-methane Volatile Organic Compounds elementary air/Medium stack, <150 meters / Rural (<… 1.7412e-05 kg lognormal, GSD² 3.07 (1,4,2,1,3,4) 0.0 ·
Carbon Monoxide (biogenic) elementary air/Medium stack, <150 meters / Rural (<… 4.1789e-04 kg lognormal, GSD² 2.07 (1,4,2,1,3,4) 0.0 ·
Sulfur Dioxide, CH elementary air/Medium stack, <150 meters / Rural (<… 1.8286e-04 kg lognormal, GSD² 1.26 (1,4,2,1,3,4) 0.0 ·
Waste Heat elementary air/Unknown 1.2544 MJ lognormal, GSD² 1.26 (1,4,2,1,3,4) 0.0 ·

Data quality

14 of 14 direct exchanges carry a declared pedigree, 14 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 1.0 · completeness 4.0 · temporal 1.93 · geographical 1.0 · technological 3.0 · sample size 4.0.

Field As declared by the publisher
Data generator / entry / validation data generator: Michael Spielmann; data entry: Michael Spielmann; validation (proof reading): Michael Spielmann
extrapolations none
sampling procedure Literature data
production volume In 2002 the production of electricity from biogas was 9.8 GWh/a.
uncertainty adjustments none
validation details Proof reading validation: Passed.; Other validation: none;
time period comment Time of publications.

Data gaps, proxies and assumptions

None recorded.

Life cycle impact assessment (EF v3.1)

Per 1 kWh. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.

Impact category Indicator Unit Result 2.5 % 97.5 % GSD²
Acidification Accumulated Exceedance (AE) mol H+ eq 3.132e-04 2.636e-04 4.098e-04 1.25
Climate change-Biogenic Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.09804 0.06977 0.1445 1.46
Climate change-Fossil Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.07009 0.05319 0.1055 1.43
Climate change-Land use and land use change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 2.113e-05 1.683e-05 3.253e-05 1.41
Climate change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.1681 0.1308 0.2389 1.36
EF-particulate Matter Impact on human health disease incidence 4.579e-09 3.488e-09 6.636e-09 1.39
Ecotoxicity, freshwater_inorganics Comparative Toxic Unit for ecosystems (CTUe) CTUe 0.491 0.3366 0.8947 1.65
Ecotoxicity, freshwater_organics Comparative Toxic Unit for ecosystems (CTUe) CTUe 0.00528 0.003914 0.01122 1.76
Ecotoxicity, freshwater Comparative Toxic Unit for ecosystems (CTUe) CTUe 0.4963 0.342 0.9044 1.65
Eutrophication marine Fraction of nutrients reaching marine end compartment (N) kg N eq 8.913e-05 6.428e-05 1.446e-04 1.52
Eutrophication, freshwater Fraction of nutrients reaching freshwater end compartment (P) kg P eq 8.085e-06 5.606e-06 4.593e-05 2.83
Eutrophication, terrestrial Accumulated Exceedance (AE) mol N eq 0.004354 0.003195 0.006275 1.42
Human toxicity, cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 4.674e-12 4.865e-12 1.604e-11 1.87
Human toxicity, cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 5.738e-12 4.684e-12 1.198e-11 1.62
Human toxicity, cancer Comparative Toxic Unit for human (CTUh) CTUh 1.041e-11 1.004e-11 2.612e-11 1.66
Human toxicity, non-cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 2.768e-10 2.654e-10 8.910e-10 1.85
Human toxicity, non-cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 2.110e-10 1.609e-10 3.193e-10 1.42
Human toxicity, non-cancer Comparative Toxic Unit for human (CTUh) CTUh 4.878e-10 4.659e-10 1.136e-09 1.6
Ionising radiation, human health Human exposure efficiency relative to U235 kBq U235 eq 0.02485 0.008735 0.1439 4.3
Land use Soil quality index pt (soil quality index) 0.4309 0.2814 0.9836 1.83
Ozone depletion Ozone Depletion Potential (ODP) kg CFC-11 eq 1.774e-09 1.176e-09 3.401e-09 1.77
Photochemical ozone formation - human health Tropospheric ozone concentration increase kg NMVOC eq 2.994e-04 2.331e-04 4.680e-04 1.44
Resource use, fossils Abiotic resource depletion fossil fuels (ADP-fossil) MJ 0.9308 0.6157 1.737 1.74
Resource use, minerals and metals Abiotic resource depletion (ADP ultimate reserve) kg Sb eq 1.217e-07 9.550e-08 2.841e-07 1.76
Water use User deprivation potential (deprivation-weighted water consumption) m3 world eq deprived 0.00298 -10.72 5.514 —

Climate change 0.1681 kg CO2 eq per kWh. Main contributors: Biogas, production mix, at storage 90 %; Nitrous Oxide 4 %; Methane (biogenic) 3 %; Cogen unit 160kWe, common components for heat+electricity 2 %.

Interpretation

Significant issues

Direct exchanges dominating climate change: Biogas, production mix, at storage 90 %; Nitrous Oxide 4 %; Methane (biogenic) 3 %; Cogen unit 160kWe, common components for heat+electricity 2 %. Most sensitive exchanges (Section 6.3): Biogas, production mix, at storage [CH] (-18.5 / +23.2 %); Nitrous Oxide [air/Medium stack, <150 meters / Rural (<1000 people/square mile)] (-2.4 / +7.1 %); Methane (biogenic) [air/Medium stack, <150 meters / Rural (<1000 people/square mile)] (-2.1 / +6.4 %).

Independent recalculation

Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh:

Category Graph Published Graph / published
Acidification 3.132e-04 0.001008 0.311
Climate change-Biogenic 0.09804 0.09804 1.000
Climate change-Fossil 0.07009 0.07009 1.000
Climate change-Land use and land use change 2.113e-05 2.113e-05 1.000
Climate change 0.1681 0.1681 1.000
EF-particulate Matter 4.579e-09 4.579e-09 1.000
Ecotoxicity, freshwater_inorganics 0.491 0.4923 0.998
Ecotoxicity, freshwater_organics 0.00528 0.005252 1.005
Ecotoxicity, freshwater 0.4963 0.4973 0.998
Eutrophication marine 8.913e-05 8.912e-05 1.000
Eutrophication, freshwater 8.085e-06 8.085e-06 1.000
Eutrophication, terrestrial 0.004354 0.00315 1.382
Human toxicity, cancer_inorganics 4.674e-12 4.582e-12 1.020
Human toxicity, cancer_organics 5.738e-12 5.738e-12 1.000
Human toxicity, cancer 1.041e-11 1.032e-11 1.009
Human toxicity, non-cancer_inorganics 2.768e-10 2.728e-10 1.015
Human toxicity, non-cancer_organics 2.110e-10 2.110e-10 1.000
Human toxicity, non-cancer 4.878e-10 4.838e-10 1.008
Ionising radiation, human health 0.02485 0.02485 1.000
Land use 0.4309 0.3495 1.233
Ozone depletion 1.774e-09 1.774e-09 1.000
Photochemical ozone formation - human health 2.994e-04 2.994e-04 1.000
Resource use, fossils 0.9308 0.9309 1.000
Resource use, minerals and metals 1.217e-07 1.144e-07 1.064
Water use 0.00298 0.007518 0.396
Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like.
Also published by BAFU for this dataset: IPCC 2021 GWP100 0.1681 kg CO2 eq; Ecological Scarcity
2021 total 216.8 UBP.

Sensitivity check

One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.

Exchange Base Low / high Range Δ GWP100 (%) Δ other categories (max %)
Biogas, production mix, at storage [CH] 0.383 m3 ×0.795 / ×1.26 lognormal, GSD² 1.26 -18.5 / +23.2 24.9 (Ecotoxicity, freshwater_inorganics)
Nitrous Oxide [air/Medium stack, <150 meters / Rural (<1000 people/square mile)] 2.176e-05 kg ×0.333 / ×3 lognormal, GSD² 3.07 -2.4 / +7.1 17.0 (Climate change-Fossil)
Methane (biogenic) [air/Medium stack, <150 meters / Rural (<1000 people/square mile)] 2.002e-04 kg ×0.333 / ×3 lognormal, GSD² 3.07 -2.1 / +6.4 11.0 (Climate change-Biogenic)
Cogen unit 160kWe, common components for heat+electricity [RER] 4.353e-08 p ×0.333 / ×3 lognormal, GSD² 3.07 -1.3 / +3.9 55.7 (Human toxicity, cancer_inorganics)
Cogen unit 160kWe, components for electricity only [RER] 5.625e-08 p ×0.333 / ×3 lognormal, GSD² 3.07 -0.2 / +0.7 38.3 (Resource use, minerals and metals)
Disposal, used mineral oil, 10% water, to hazardous waste incineration [CH] 2.612e-04 kg ×0.795 / ×1.26 lognormal, GSD² 1.26 -0.1 / +0.1 0.3 (Climate change-Fossil)
Lubricating oil, at plant [RER] 2.612e-04 kg ×0.795 / ×1.26 lognormal, GSD² 1.26 -0.0 / +0.1 8.3 (Climate change-Land use and land use change)
Nitrogen Oxides, CH [air/Medium stack, <150 meters / Rural (<1000 people/square mile) [CH]… 1.306e-04 kg ×0.489 / ×2.04 lognormal, GSD² 2.07 -0.0 / +0.0 59.5 (Eutrophication marine)
Non-methane Volatile Organic Compounds [air/Medium stack, <150 meters / Rural (<1000 peopl… 1.741e-05 kg ×0.333 / ×3 lognormal, GSD² 3.07 -0.0 / +0.0 11.7 (Photochemical ozone formation - human health)
Carbon Monoxide (biogenic) [air/Medium stack, <150 meters / Rural (<1000 people/square mil… 4.179e-04 kg ×0.489 / ×2.04 lognormal, GSD² 2.07 -0.0 / +0.0 0.0 (Ecotoxicity, freshwater_inorganics)
Sulfur Dioxide, CH [air/Medium stack, <150 meters / Rural (<1000 people/square mile) [CH]] 1.829e-04 kg ×0.795 / ×1.26 lognormal, GSD² 1.26 -0.0 / +0.0 7.4 (Acidification)

Uncertainty analysis

Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.

Comparison with other data

No other location of this dataset in the graph.

Conclusions and limitations

GWP100 0.1681 kg CO2 eq per kWh (95 % interval 0.1308–0.2389). Dominant contributors: Biogas, production mix, at storage 90 %; Nitrous Oxide 4 %; Methane (biogenic) 3 %; Cogen unit 160kWe, common components for heat+electricity 2 %. Most sensitive: Biogas, production mix, at storage [CH] (-18.5 / +23.2 %); Nitrous Oxide [air/Medium stack, <150 meters / Rural (<1000 people/square mile)] (-2.4 / +7.1 %); Methane (biogenic) [air/Medium stack, <150 meters / Rural (<1000 people/square mile)] (-2.1 / +6.4 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.

Final control

Item Status Detail
reference flow PASS production amount 1.0 kWh
closure: sum of direct contributions = dataset score (all 25 categories) PASS largest relative gap 3.3e-16
independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh (climate change) PASS graph / published = 1; categories within ±5 %: 20/25
every technosphere input of the EcoSpold delivery is in the graph PASS all present (bafu_links_check.py)
uncertainty declared on the direct exchanges PASS 14/14 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values
Monte Carlo 95 % interval contains the deterministic score PASS 0.1681 in [0.1308, 0.2389]
time period declared PASS 2000-01/2004-12
geography is a known location code PASS CH
sources cited PASS 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them

References

  1. Jungbluth N., Chudacoff M., Dauriat A., Dinkel F., Doka G., Faist Emmenegger M., Gnansounou E., Kljun N., Spielmann M., Stettler C., Sutter J. (2007) Life Cycle Inventories of Bioenergy. Final report ecoinvent data v2.0. Volume: 17. Swiss Centre for LCI, ESU. Duebendorf and Uster, CH. Type: Measurement on site Source: CD-ROM First author: Jungbluth N. Other authors: Chudacoff M., Dauriat A., Dinke… — published source; as declared by BAFU (not found in OpenAlex/Crossref)
  2. Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — database; dataset citation
  3. International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva.
  4. Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. (tdc-doc method reference; title, version and year to verify against the user's copy)
  5. European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra.
  6. Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236

Annex — licence and terms of use

BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.


To suggest a correction or a dataset that does not exist yet, use Propose a dataset.

datasets/bafu/aeb0fb1c-e3e4-371c-802e-7513e1b69faa.txt · Last modified: by 127.0.0.1

Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki