OpenData Wiki

Dataset documentation and review before publication

User Tools

Site Tools


datasets:bafu:b56ab465-b4a4-3f61-9e6b-5a656327a4e6

Photovoltaic panel for PVT, single-Si, without flat glass, at regional storage — RER

Dataset documentation and final control (tdc-doc, imported mode)
Open this dataset in OpenData

Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Photovoltaic panel for PVT, single-Si, without flat glass, at regional storage [RER], per 1 m2. EF v3.1 climate change 110.9 kg CO2 eq (Monte Carlo 95 % interval 56.81–344.5). Main contributors: Photovoltaic panel for PVT, single-Si, without flat glass, a… 79 %; Photovoltaic panel for PVT, single-Si, without flat glass, a… 11 %; Photovoltaic panel for PVT, single-Si, without flat glass, a… 6 %; Transport, transoceanic freight ship 4 %. Status: final control passed.
Item Value
Dataset name Photovoltaic panel for PVT, single-Si, without flat glass, at regional storage
Dataset UUID / graph id b56ab465-b4a4-3f61-9e6b-5a656327a4e6 / activity:photovoltaic_panel_for_pvt_single_si_without_flat_glass_at_regional_storage__rer
Reference product, unit Photovoltaic panel for PVT, single-Si, without flat glass, at regional storage, 1 m2
Location RER
Time period 2015-01/2020-12
Category heat / pvt\heating systems
Source database BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1
Publisher Swiss Federal Office for the Environment (FOEN/BAFU)
Background database BAFU 2026 v1 (graph bafuquery-db)
LCIA method EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix)
Status final control passed
Documented by tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17

Introduction

Shares of production in Europe (15%) and import from APAC (6%) and China (79%). ALL WITHOUT FLAT GLASS! ONLY FOR USE IN PVT-SYSTEM!; Synonyms: Solarmodul nur für PVT-Systeme, PV-module for PVT systems only, cadmium telluride, thin film, WITHOUT FLAT GLASS; UUID: b56ab465-b4a4-3f61-9e6b-5a656327a4e6

This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.

Goal and scope

Function, functional unit and reference flow

Reference flow: 1 m2 of Photovoltaic panel for PVT, single-Si, without flat glass, at regional storage (RER). All results are given per unit of the reference flow.

System boundary

Consumption mix for use in Europe ONLY FOR PVT-SYSTEM (all the pv-modules are WITHOUT FLAT GLASS)!! Transport of modules from overseas.

Technology

Modern production plant.

Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).

LCIA method

EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.

Life cycle inventory

Inventory table

Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).

Exchange Type Location / compartment Amount Unit Uncertainty Pedigree GWP share (%) Notes
Photovoltaic panel for PVT, single-Si, without flat glass, at plant technosphere CN 0.79585 m2 lognormal, GSD² 3.27 — 79.0 ████████████████
Photovoltaic panel for PVT, single-Si, without flat glass, at plant technosphere RER 0.14536 m2 lognormal, GSD² 3.27 — 11.2 ██
Photovoltaic panel for PVT, single-Si, without flat glass, at plant technosphere APAC 0.058789 m2 lognormal, GSD² 3.27 — 5.6 █
Transport, transoceanic freight ship technosphere OCE 600.08 tkm lognormal, GSD² 3.04 — 3.7 █
Transport, freight, lorry, fleet average technosphere RER 1.7832 tkm lognormal, GSD² 3.04 — 0.3 ·
Transport, freight, rail technosphere RER 7.1327 tkm lognormal, GSD² 3.04 — 0.1 ·

Data quality

0 of 6 direct exchanges carry a declared pedigree, 6 carry a distribution.

Field As declared by the publisher
Data generator / entry / validation data generator: Livia Waldburger (CARBOTECH); data entry: Thomas Kaegi (CARBOTECH); validation (proof reading): Andy Spoerri (EBP)
extrapolations
sampling procedure Data provided by manufacturer and literature data on worldwide module production.
production volume na
uncertainty adjustments none
validation details Proof reading validation: 14.09.2020; Other validation: Z:\Schreibtisch\WinShare\BAFU Heizsysteme_A-Konvertieren\PVT[EcoSpold_photovoltaic panel for PVT, single-Si, without tempering flat glass, at regional storage_v0.1_lwa.xlsx]X-Process;
time period comment undefined

Data gaps, proxies and assumptions

None recorded.

Life cycle impact assessment (EF v3.1)

Per 1 m2. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.

Impact category Indicator Unit Result 2.5 % 97.5 % GSD²
Acidification Accumulated Exceedance (AE) mol H+ eq 0.4651 0.2855 1.289 2.16
Climate change-Biogenic Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.6334 0.2648 2.404 3.07
Climate change-Fossil Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 110.2 56.38 342.6 2.55
Climate change-Land use and land use change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.04991 0.02646 0.1543 2.53
Climate change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 110.9 56.81 344.5 2.55
EF-particulate Matter Impact on human health disease incidence 3.343e-06 1.846e-06 2.794e-05 3.88
Ecotoxicity, freshwater_inorganics Comparative Toxic Unit for ecosystems (CTUe) CTUe 758.3 393.5 2766 2.75
Ecotoxicity, freshwater_organics Comparative Toxic Unit for ecosystems (CTUe) CTUe 10.48 6.147 41.27 2.66
Ecotoxicity, freshwater Comparative Toxic Unit for ecosystems (CTUe) CTUe 768.7 400.8 2807 2.74
Eutrophication marine Fraction of nutrients reaching marine end compartment (N) kg N eq 0.1985 0.1128 0.5497 2.27
Eutrophication, freshwater Fraction of nutrients reaching freshwater end compartment (P) kg P eq 0.03697 0.02008 0.2042 3.33
Eutrophication, terrestrial Accumulated Exceedance (AE) mol N eq 1.187 0.7384 3.439 2.17
Human toxicity, cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 2.900e-08 1.709e-08 1.413e-07 3.02
Human toxicity, cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 2.908e-08 1.462e-08 9.881e-08 2.69
Human toxicity, cancer Comparative Toxic Unit for human (CTUh) CTUh 5.808e-08 3.312e-08 2.355e-07 2.76
Human toxicity, non-cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 1.547e-06 9.214e-07 7.971e-06 3.14
Human toxicity, non-cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 6.103e-08 3.270e-08 2.055e-07 2.65
Human toxicity, non-cancer Comparative Toxic Unit for human (CTUh) CTUh 1.608e-06 9.608e-07 8.158e-06 3.11
Ionising radiation, human health Human exposure efficiency relative to U235 kBq U235 eq 24.08 6.098 239.2 6.18
Land use Soil quality index pt (soil quality index) 844.3 433.1 3007 2.68
Ozone depletion Ozone Depletion Potential (ODP) kg CFC-11 eq 3.276e-06 1.728e-06 1.064e-05 2.6
Photochemical ozone formation - human health Tropospheric ozone concentration increase kg NMVOC eq 0.3782 0.2371 1.103 2.17
Resource use, fossils Abiotic resource depletion fossil fuels (ADP-fossil) MJ 1413 747.7 4481 2.54
Resource use, minerals and metals Abiotic resource depletion (ADP ultimate reserve) kg Sb eq 0.004473 0.00201 0.01335 2.6
Water use User deprivation potential (deprivation-weighted water consumption) m3 world eq deprived 130.1 -3.172e+04 1.991e+04 —

Climate change 110.9 kg CO2 eq per m2. Main contributors: Photovoltaic panel for PVT, single-Si, without flat glass, a… 79 %; Photovoltaic panel for PVT, single-Si, without flat glass, a… 11 %; Photovoltaic panel for PVT, single-Si, without flat glass, a… 6 %; Transport, transoceanic freight ship 4 %.

Interpretation

Significant issues

Direct exchanges dominating climate change: Photovoltaic panel for PVT, single-Si, without flat glass, a… 79 %; Photovoltaic panel for PVT, single-Si, without flat glass, a… 11 %; Photovoltaic panel for PVT, single-Si, without flat glass, a… 6 %; Transport, transoceanic freight ship 4 %. Most sensitive exchanges (Section 6.3): Photovoltaic panel for PVT, single-Si, without flat glass, at plant [CN] (-54.3 / +173.4 %); Photovoltaic panel for PVT, single-Si, without flat glass, at plant [RER] (-7.7 / +24.6 %); Photovoltaic panel for PVT, single-Si, without flat glass, at plant [APAC] (-3.9 / +12.4 %).

Independent recalculation

Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026):

Category Graph Published Graph / published
Acidification 0.4651 0.4856 0.958
Climate change-Biogenic 0.6334 0.6334 1.000
Climate change-Fossil 110.2 110.2 1.000
Climate change-Land use and land use change 0.04991 0.04991 1.000
Climate change 110.9 110.9 1.000
EF-particulate Matter 3.343e-06 3.343e-06 1.000
Ecotoxicity, freshwater_inorganics 758.3 763.3 0.993
Ecotoxicity, freshwater_organics 10.48 7.958 1.317
Ecotoxicity, freshwater 768.7 770.7 0.998
Eutrophication marine 0.1985 0.1985 1.000
Eutrophication, freshwater 0.03697 0.03697 1.000
Eutrophication, terrestrial 1.187 1.215 0.977
Human toxicity, cancer_inorganics 2.900e-08 2.881e-08 1.007
Human toxicity, cancer_organics 2.908e-08 2.908e-08 1.000
Human toxicity, cancer 5.808e-08 5.788e-08 1.003
Human toxicity, non-cancer_inorganics 1.547e-06 1.538e-06 1.006
Human toxicity, non-cancer_organics 6.103e-08 6.091e-08 1.002
Human toxicity, non-cancer 1.608e-06 1.599e-06 1.006
Ionising radiation, human health 24.08 24.08 1.000
Land use 844.3 675.4 1.250
Ozone depletion 3.276e-06 3.276e-06 1.000
Photochemical ozone formation - human health 0.3782 0.3782 1.000
Resource use, fossils 1413 1414 1.000
Resource use, minerals and metals 0.004473 0.004407 1.015
Water use 130.1 129.6 1.004
Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like.
Also published by BAFU for this dataset: IPCC 2021 GWP100 110.7 kg CO2 eq; Ecological Scarcity
2021 total 2.152e+05 UBP.

Sensitivity check

One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.

Exchange Base Low / high Range Δ GWP100 (%) Δ other categories (max %)
Photovoltaic panel for PVT, single-Si, without flat glass, at plant [CN] 0.7958 m2 ×0.313 / ×3.19 lognormal, GSD² 3.27 -54.3 / +173.4 195.8 (Water use)
Photovoltaic panel for PVT, single-Si, without flat glass, at plant [RER] 0.1454 m2 ×0.313 / ×3.19 lognormal, GSD² 3.27 -7.7 / +24.6 44.0 (Climate change-Biogenic)
Photovoltaic panel for PVT, single-Si, without flat glass, at plant [APAC] 0.05879 m2 ×0.313 / ×3.19 lognormal, GSD² 3.27 -3.9 / +12.4 16.2 (Ionising radiation, human health)
Transport, transoceanic freight ship [OCE] 600.1 tkm ×0.337 / ×2.97 lognormal, GSD² 3.04 -2.5 / +7.3 62.9 (Eutrophication, terrestrial)
Transport, freight, lorry, fleet average [RER] 1.783 tkm ×0.337 / ×2.97 lognormal, GSD² 3.04 -0.2 / +0.6 5.1 (Climate change-Land use and land use change)
Transport, freight, rail [RER] 7.133 tkm ×0.337 / ×2.97 lognormal, GSD² 3.04 -0.1 / +0.2 1.3 (Human toxicity, non-cancer_organics)

Uncertainty analysis

Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.

Comparison with other data

No other location of this dataset in the graph.

Conclusions and limitations

GWP100 110.9 kg CO2 eq per m2 (95 % interval 56.81–344.5). Dominant contributors: Photovoltaic panel for PVT, single-Si, without flat glass, a… 79 %; Photovoltaic panel for PVT, single-Si, without flat glass, a… 11 %; Photovoltaic panel for PVT, single-Si, without flat glass, a… 6 %; Transport, transoceanic freight ship 4 %. Most sensitive: Photovoltaic panel for PVT, single-Si, without flat glass, at plant [CN] (-54.3 / +173.4 %); Photovoltaic panel for PVT, single-Si, without flat glass, at plant [RER] (-7.7 / +24.6 %); Photovoltaic panel for PVT, single-Si, without flat glass, at plant [APAC] (-3.9 / +12.4 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.

Final control

Item Status Detail
reference flow PASS production amount 1.0 m2
closure: sum of direct contributions = dataset score (all 25 categories) PASS largest relative gap 3.8e-16
independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) PASS graph / published = 1; categories within ±5 %: 23/25
every technosphere input of the EcoSpold delivery is in the graph PASS all present (bafu_links_check.py)
uncertainty declared on the direct exchanges PASS 6/6 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values
Monte Carlo 95 % interval contains the deterministic score PASS 110.9 in [56.81, 344.5]
time period declared PASS 2015-01/2020-12
geography is a known location code PASS RER
sources cited PASS 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them

References

  1. Kägi Thomas, Livia Waldburger, Cyril Kern, Gavin Roberts, Mischa Zschokke, Flora Conte, Lea Weber (2020) LCI of heating systems. Carbotech im Auftrag des BAFU. Carbotech AG. Zürich. CH. Type: Separate publication Source: Report First author: Kägi Thomas Other authors: Livia Waldburger, Cyril Kern, Gavin Roberts, Mischa Zschokke, Flora Conte, Lea Weber Year: 2020 Title of anthology: Carbotech im Au… — published source; as declared by BAFU (not found in OpenAlex/Crossref)
  2. Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — database; dataset citation
  3. International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva.
  4. Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. (tdc-doc method reference; title, version and year to verify against the user's copy)
  5. European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra.
  6. Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236

Annex — licence and terms of use

BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.


To suggest a correction or a dataset that does not exist yet, use Propose a dataset.

datasets/bafu/b56ab465-b4a4-3f61-9e6b-5a656327a4e6.txt · Last modified: by 127.0.0.1